Soft Start-up Characteristics Analysis of Squirrel Cage Induction Generator (농형 유도 발전기의 소프트 기동 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.103-107
    • /
    • 2016
  • In general, the voltage stability of induction generator is lower than synchronous generator. Induction generator has a number of advantages over the synchronous generator on the side of price and maintenance. So Induction generator has been applied to the small hydroelectric power of low output. Induction generator usually generates a high current during grid connection. The high current that occurs during grid connection can cause a voltage drop in the system. In order to increase the supply of the induction generator, it is necessary to propose a method of reducing high current. This paper proposes some method of the soft start to reduce voltage drop caused by the large starting current. soft-start method has high voltage drop effect than direct start method, control of firing angle can be increased the voltage drop effect.

An Experimental Study on Spark Timing Effect for Fast warmup of Catalyst to Cold Start Operation of an SI Engine (가솔린기관의 냉시동시 촉매 가열 촉진을 위한 점화시기 영향에 대한 실험적 연구)

  • Kwon, Y.W.;Ham, S.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.101-108
    • /
    • 2011
  • On cold start operation of an SI engine, a catalyst shows poor performance before it reaches activation temperature. Therefore, fast warmup of the catalyst is very crucial to reduce harmful emissions. In this study, an appropriate control strategy is investigated to increase exhaust gas temperature through changes of spark timing. Combustion stability is also considered at the same time. Exhaust gas temperature and pressure of combustion chamber are measured to investigate the effects of spark timings on cold start and idle performance. Experiments showed that retarded spark timing promotes the combustion at the end of expansion stroke and increases exhaust gas temperature during cold start.

A minimum-time trajectory planning for dual robot system using running start (초기속도 부가에 의한 두 대의 로보트 시스템의 최소시간 경로계획)

  • 이지홍;문점생
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.423-427
    • /
    • 1993
  • A velocity planning method is proposed that ensures collision-free and minimal delay-time motions for two robotic manipulators and auxiliary equipments. Additional path, which makes robot start with possible largest speed, is added to the original prescribed path of one of two robots, and this running start along the additional path reduces delay time introduced to avoid collision between the robots and therefore reduces total traveling time.

  • PDF

The Effects of the "We Start" Institution Visiting Intervention Program on the Development of Young Children from Low-Income Families (위스타트(We Start) 기관방문 교육중재 프로그램이 저소득가정 유아의 발달에 미치는 영향)

  • Hwang, Hye Jung
    • Human Ecology Research
    • /
    • v.52 no.2
    • /
    • pp.189-198
    • /
    • 2014
  • The purpose of this study was to examine the effects of the We Start center visiting intervention program on the positive changes in the developmental areas and literacy interests of young children from low-income families. The subjects were 195 young children (109 in the experimental group, M=71.7 months; 86 in the control group, M=73.3 months) living in We Start areas (Ansan, Gwangmyeong, and Suwon cities) of Gyeonggi-do. The We Start center visiting intervention programs were conducted for 30-34 weeks in each city, and pre-tests and post-tests were conducted before and after the intervention programs. The instruments used were the developmental checklist and the literacy interests test The developmental checklist consisted of 7 domains (personality & sociality; language, reading, & writing; scientific thinking; mathematical thinking; arts; social learning; and physical development). The literacy interests test consisted of 2 factors (interest in literacy and interaction during activity). The scores on the developmental checklist showed positive changes in several domains (personality & social development; language, reading, & writing ability; scientific thinking; and social learning), but not in mathematical thinking, arts, and physical development. Second, the results of the literacy interests test showed positive effects on interaction during activity and the total score. In conclusion, the We Start center visiting program for young children from low-income families is an effective early intervention program to end the intergenerational transference of poverty in Korea.

Effects of Base Changes at the Transcription Start Site on Stringent Control of rnpB in Escherichia coli

  • Choi, Hyun-Sook;Park, Jeong Won;Hong, Soon Kang;Lee, Kangseok;Lee, Younghoon
    • Molecules and Cells
    • /
    • v.26 no.2
    • /
    • pp.212-215
    • /
    • 2008
  • The GC-rich discriminator sequence between the -10 region and the transcription start site of the rnpB promoter is responsible for stringent control of M1 RNA synthesis. The rnpB promoter also contains a G nucleotide at the previously identified transcription start site. In this study, we examined by mutagenesis of G to A whether this +1G nucleotide is involved in the stringent response. We found that the change did not alter the stringent response. Since the +1 mutation might alter transcription initiation, we compared the transcription start sites of the wt and mutant promoters by primer extension analysis. Surprisingly, we found that wild type rnpB transcription starts at both the +1G position (70%) and the -1C position (30%), and that the +1A mutation led to transcription initiation exclusively at the -1C position. We also generated two transversion mutations at the -1 position, both of which led to transcription starting exclusively at that position. The -1G mutant promoter gave a stringent signal similar to the wild-type, whereas the -1A mutant generated a significantly less stringent signal. Base on these results, we propose that a short sequence, up to 7 bp downstream of the -10 region, is involved in the stringent response of the rnpB promoter.

Start-up and operation of Gasoline Fuel Processor for Isolated Fuel Cell System (독립형 연료전지 시스템을 위한 가솔린 연료프로세스의 시동 및 운전)

  • Ji, Hyunjin;Bae, Joongmyeon
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.76-85
    • /
    • 2016
  • This study introduces the system layout and control strategy necessary to start and operate a fuel processor in a wide range of temperatures where a gasoline was selected as the fuel of fuel processor considering logistic support of Korea Army. The autothermal reformig(ATR) catalyst is heated to light-off temperature by combustion method in the initial stage. In order to ignite the gasoline and air mixture stably, the glow plug is installed after ATR catalyst. When the catalyst is increased to light-off temperature, the reformer is operated from initiation to steady state conditions as follows: Partial oxidation(POX) mode, partial ATR mode, full ATR mode. Finally the start-up and control strategy is validated by the operational test of gasoline fuel processor at low and room temperature. As a result the gasoline fuel processor is able to start-up within 40 min and to produce the reformate gas which has 37 ~ 42 vol.%(dry basis) of $H_2$ and 0.3 vol.% of CO.

A Study on Startup-Characteristic of Sensorless Controlled IPMSM Employing Sliding Mode Observer (슬라이딩 모드 관측기를 이용한 IPMSM의 센서리스 제어의 기동특성에 관한 연구)

  • Kim, Sang-Hun;Kwon, Soon-Jae;Kim, Marn-Go;Jung, Young-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.38-43
    • /
    • 2011
  • This paper presents the improvement of start-up characteristic of sensorless controlled IPMSM(Interior Permanent Magnet Synchronous Motor) with SMO(Sliding Mode Observer). It is difficult to utilize the rotor position information at starting point for the back EMF estimation based sensorless control. For this reason, open loop control is normally used during start-up period. However, changing from open loop to closed loop control might bring a problem on the transient characteristics for difference load conditions. To solve this problem, we add another rotor angle controller. Simulation results and experimental results are presented to verify proposed method.

Artificial Neural Network Models for Optimal Start and Stop of Chiller and AHU (인공신경망 모델을 이용한 냉동기 및 공조기 최적 기동/정지 제어)

  • Park, SungHo;Ahn, Ki Uhn;Hwang, Aaron;Choi, Sunkyu;Park, Cheol Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.2
    • /
    • pp.45-52
    • /
    • 2019
  • BEMS(Building Energy Management Systems) have been applied to office buildings and collect relevant building energy data, e.g. temperatures, mass flow rates and energy consumptions of building mechanical systems and indoor spaces. The aforementioned measured data can be beneficially utilized for developing data-driven machine learning models which can be then used as part of MPC(Model Predictive Control) and/or optimal control strategies. In this study, the authors developed ANN(Artificial Neural Network) models of an AHU (Air Handling Unit) and a chiller for a real-life office building using BEMS data. Based on the ANN models, the authors developed optimal control strategies, e.g. daily operation schedule with regard to optimal start and stop of the AHU and the chiller (500 RT). It was found that due to the optimal start and stop of the AHU and the chiller, 4.5% and 16.4% of operation hours of the AHU and the chiller could be saved, compared to an existing operation.

Black Start and Synchronization of Microgrid Considering Distributed Generation Control (분산전원의 제어 특성을 고려한 마이크로그리드의 블랙 스타트 및 계통 동기화 전략)

  • Choi, Jin-Young;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.898-904
    • /
    • 2013
  • In order to minimize the damage from power outage, power system should be restored quickly. In this paper, a procedure for the restoration of microgrid is proposed. After elimination of the causes of power outage, a black start algorithm is executed by considering the characteristics of distributed generation control. After all resources have been recovered to the normal state, a grid reconnecting algorithm for stable operation in grid-connected mode is performed. In order to verify the proposed algorithm, low voltage microgrid is simulated using PSCAD/EMTDC.

Electromyographic Study of the Sternohyoid Muscle to Control an Electrolarynx (인공후두 제어원으로서의 흉골설골근 사용의 타당성 검증)

  • 민혜정;봉정표
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.201-208
    • /
    • 1996
  • We have been studying an implant type EMG-controlled electrolarynx. First of all, we propose the sternohyoid muscle(SH) as a control source of the electrolarynx. The purpose of this study is to investigate the possibility that subjects control voluntarily the constriction of their SH, and produce the control signals of electrolarynx. For this pwnan, we carried out four experiments regarding the control of the electrolarynx. At the results, we found that subjects can control the start/stop of constriction and the amplitude of EMG of their SH. Also, we ascertained the possibility that the start/stop of contraction of SH controls OW/OFF of sound source of the electrolarynx and the amplitude of UG of SH controls the pitch frequency of the electrolarynx.

  • PDF