• Title/Summary/Keyword: Standby system

Search Result 214, Processing Time 0.026 seconds

Dynamic Voltage Compensator using Series and Shunt Inverters (직.병렬 인버터를 이용한 동적전압보상기)

  • Park, Deok-Hui;Lee, Jun-Gi;Han, Byeong-Mun;So, Yong-Cheol;Kim, Hyeon-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.655-662
    • /
    • 1999
  • This paper describes controller design and simulation-model development of a dynamic voltage compensator using series and shunt inverters. The control system was designed using PI controller and vector relationship between the supply voltage and load voltage. A simulation model with EMTP was developed to analyze performance of the controller and the whole system. The simulation and experiment results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system, such as single-line-ground fault, three-line-to-ground fault, and line-to-line fault.

  • PDF

Research on the Changeover Software for Duplicated Countdown Time Generating Device of the Mission Control System (발사통제시스템의 이중화된 카운트다운 타임 생성 장치간 절체 운용 소프트웨어 설계 연구)

  • Kim, Jeong-Seok;Han, Yoo-Soo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.33-36
    • /
    • 2016
  • 발사통제시스템의 주요 구성장치인 카운트다운 타임 생성 시스템은 카운트다운 신호를 생성하여 타 시스템에 제공하는 임무를 수행한다. 발사 관련 주요 장비들은 카운트다운 타임 생성 장치로부터 수신한 카운트다운 타임 정보에 따라 기능 수행을 하므로 안정적인 카운트다운 타임의 제공이 필수적이다. 따라서 카운트다운 타임 생성 시스템은 신뢰성과 고장 감내성을 보장하기 위한 설계가 요구된다. 이를 위해서는 시스템의 신뢰성을 보장하기 위한 방안으로 구성 장치들을 이중화하고 고장을 실시간 감시하여 고장 발생시 Active 장치에서 Standby 장치로의 절체 운용에 대한 설계가 필요하다. 본 논문에서는 카운트다운 타임 생성 장치의 이중화 설계에 따른 실시간 고장 감지 및 절체 운용 방법과 기능 시험 결과에 대하여 기술하였다.

  • PDF

Implementation of Inductive Wireless Power Transfer System based on LLC Converter without Wireless Communication between Tx and Rx (Tx-Rx간 무선통신이 필요 없는 LLC 컨버터 기반 유도형 무선전력전송 시스템 구현)

  • Kim, Moon-Young;Choi, Shin-Wook;Kang, Jeong-il;Han, Jonghee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.311-318
    • /
    • 2019
  • In general wireless power transfer systems (WPTSs), power transfer is controlled by the wireless communication between a transmitter (Tx) and a receiver (Rx). However, WPTS is difficult to apply in electronic products that do not have batteries, such as TVs. A WPTS with resonators based on a transformer of LLC series resonant converter is proposed in this study to eliminate wireless communication units between a Tx and an Rx. The proposed system operates at the boundary of the resonance frequency, and the required power can be stably supplied to authorized devices even though some misalignment occurs. Moreover, standby power standards for the electronic product can be satisfied.

A Context-Aware Treatment Guidance System (상황인지를 이용한 진료 안내 시스템)

  • Jung, Hwa Young;Park, Jae Wook;Lee, Yong Kyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.1
    • /
    • pp.141-148
    • /
    • 2014
  • As the quality of the medical treatment service provided by large hospitals grow, the number of patients utilizing the facilities is increasing dramatically. Various studies such as order communication system and treatment guidance system are under their process in order to shorten the waiting time for patients. However, the existing methods assign the treatments in successive order without recognizing the situation of each treatment, therefore increasing a patient's standby time at a hospital. This paper proposes a context-aware treatment guidance system, which recognizes the previously undermined estimated waiting time of each treatment for a patient and recommends a treatment with shorter estimated sojourn time first. This context-aware treatment guidance system provides detailed information of treatment services based on the recommended order of treatments to a patient's smartphone. By utilizing the context-aware treatment guidance system introduced in this paper, patients can reduce their standby time at hospitals to the minimum while hospitals can efficiently service more patients at the same amount of time. The proposed context-aware treatment guidance system proves to be outstanding in treatment order recommendation through comparisons to previously used methods.

The Design of Fault Tolerant Dual System and Real Time Fault Detection for Countdown Time Generating System

  • Kim, Jeong-Seok;Han, Yoo-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.10
    • /
    • pp.125-133
    • /
    • 2016
  • In this paper, we propose a real-time fault monitoring and dual system design of the countdown time-generating system, which is the main component of the mission control system. The countdown time-generating system produces a countdown signal that is distributed to mission control system devices. The stability of the countdown signal is essential for the main launch-related devices because they perform reserved functions based on the countdown time information received from the countdown time-generating system. Therefore, a reliable and fault-tolerant design is required for the countdown time-generating system. To ensure system reliability, component devices should be redundant and faults should be monitored in real time to manage the device changeover from Active mode to Standby mode upon fault detection. In addition, designing different methods for mode changeover based on fault classification is necessary for appropriate changeover. This study presents a real-time fault monitoring and changeover system, which is based on the dual system design of countdown time-generating devices, as well as experiment on real-time fault monitoring and changeover based on fault inputs.

Analysis on Application of Flywheel Energy Storage System for offshore plants with Dynamic Positioning System

  • Jeong, Hyun-Woo;Kim, Yoon-Sik;Kim, Chul-Ho;Choi, Sung-Hwan;Yoon, Kyoung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.7
    • /
    • pp.935-941
    • /
    • 2012
  • This paper describes a study of conventional electrical rig and simulated application of Flywheel Energy Storage system on the power system of the offshore plants with dynamic positioning system with the following aims: improve fuel consumption on engines, prevent blackout and mitigate voltage sags due to pulsed load and fault. Fuel consumption has been analyzed for the generators of the typical drilling rigs compared with the power plant with Flywheel Storage Unit which has an important aid in avoiding power interruption during DP (Dynamic Positioning) operation. The FES (Fly wheel Energy storage System) releases energy very quickly and efficiently to ensure continuity of the power supply to essential consumers such as auxiliary machinery and thrusters upon main power failure. It will run until the standby diesel generator can start and supply the electric power to the facilities to keep the vessel in correct position under DP operation. The proposed backup method to utilize the quick and large energy storage Flywheel system can be optimized in any power system design on offshore plant.

Implementation of Smart Multi-tap System based on Zigbee Communication (Zigbee 통신 기반 스마트 멀티탭 시스템 구현)

  • Lee, Jung-Hyuck;Kim, Sang-Hyun;Oh, Chang-Se;Seo, Min-Seok;Kim, Young-Don;Park, Hyun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.10
    • /
    • pp.930-936
    • /
    • 2014
  • Smart Multiple-Tap to be introduced in this paper, is an electronic device that controls the Multibple-Tap through the Smartphone. It runs on network and has an inbuilt Zigbee communication module. Thus, users can control home devices from remote through home server. Mentioned home server is operated as a gateway and is connected with smart devices on the Internet. To sum up, Users using this Smart Multiple-Tap can check the state information of the multi-tap ON/OFF and can control immediately by smartphone. also, Smart Multiple-Tap perfectly shut down the standby power. when users turn off each of the Smart Multiple-Tap's circle, It drives automatically lowest electricity-consuming mode and shut down the standby power by its own built-in SSR module. therefore, it will bring the energy saving effect on environment using Smart Multiple-Tap.

The Study on the redundancy of HVDC Control and Protection System (HVDC Control and Protection 시스템의 이중화에 대한 고찰)

  • Moon, Jun-Mo;Lee, Yil-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.175-176
    • /
    • 2014
  • 본 논문은 HVDC C&P 시스템에 적용된 이중화 기술 및 기능을 설명한다. LS산전은 2009년 HVDC 사업을 착수한 이래 HVDC Control and Protection(C&P) System을 개발해 왔으며 현재 2010년부터 한국전력공사와 협동연구로 진행하고 있는 HVDC 제주 실증단지에 적용하여 실증운전 중이다. 당사가 개발한 HVDC C&P 시스템은 시스템의 신뢰성 및 가용성을 높이기 위해 Fully Redundancy 시스템으로 구성되고 Hot Standby 방식으로 제어 및 보호 알고리즘을 수행한다. 본 논문에서는 HVDC C&P 시스템의 구성과 제어기 및 네트워크의 이중화 구조에 대해 소개 하고자 한다.

  • PDF

Analysis and Evaluation Study on Diesel Generator Engine Operation Signature (디젤발전기 엔진 운전상태 분석 및 평가방법에 대한 연구)

  • Park, J.H.;Choi, K.H.;Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.82-88
    • /
    • 2009
  • The purpose of this paper is to provide technical background, techniques and actual diesel engine signature analysis evaluation result. Engine signature analysis(ESA) is a process for monitoring the material condition of diesel engine using external sensors, eliminating the need to periodically disassemble the engine. ESA is also used to balanced the engine. Engine balancing is the process of tuning the engine so that all cylinders carry equal load. ESA is a useful tool to non-intrusively determine the operability and performance and assessment of the material condition of internal component of a diesel engine.

  • PDF

A Method of Dependability Improvement for an Intrusion Tolerance System (침입감내시스템의 신인도 향상 방안)

  • Park, Bum-Joo;Park, Kie-Jin;Kim, Sung-Soo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.971-974
    • /
    • 2005
  • 네트워크 기반 컴퓨터 시스템이 내/외부 침입에 의해 시스템 일부가 손상(Partially Compromised) 되더라도, 최소한의 필수 서비스를 지속적으로 제공할 수 있게 해주는 침입감내시스템(Intrusion Tolerance System)의 설계에 요구되는 요소 기술 중의 하나는 정량적 신인도(Dependability) 분석이라 할 수 있다. 특히, 신인도중에서 생존성(Survivability)은 침임감내의 개념을 일관되게 반영하고 있는 척도(Measure)이므로 침입감내시스템의 설계시 중요한 요소라 할 수 있다. 본 논문에서는 자가치유 (Self-healing) 메커니즘을 활용하여 주서버와 보조서버가 각 1 대인 Cold-standby 방식의 침입감내시스템의 상태천이(State Transition)를 표현한 후, 시스템의 가용도 및 생존성을 정의하였다. 또한, 시뮬레이션을 통해 두가지 취약성 공격 사례에 대한 생존성 변화추이를 분석함으로써 신인도 향상 방안을 기술하였다.

  • PDF