• Title/Summary/Keyword: Standby System

Search Result 214, Processing Time 0.026 seconds

Design and Implementation of a Wireless Sensor Network Protocol for a Smart Power Outlet System (스마트 아웃렛 시스템을 위한 무선 센서네트워크 프로토콜 설계 및 구현)

  • Chung, Han-Su;Moon, Jung-Ho;Park, Sung-Wook;Lee, Hyung-Bong;Park, Lae-Jeong;Chung, Tae-Yun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.6
    • /
    • pp.291-300
    • /
    • 2012
  • This paper deals with the design and implementation of wireless sensor network protocol for smart power outlet system capable of fire detection, power monitoring, standby power cutoff, and home automation. The proposed protocol integrates both the CSMA and the TDMA protocols for low power consumption and good scalability. A prototype smart power outlet system employing the proposed protocol and a simple home automation network including the power outlet system have been implemented for evaluating the feasibility of the proposed protocol The result shows that the proposed protocol allows the power outlet system to be scalable with high power efficiency.

Buck converter with new driving circuit in TV poer system (TV 전원장치에서 새로운 구동 회로에 의한 buck converter)

  • 정진국
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.56-61
    • /
    • 1996
  • In this paper, new buck converter of a TV power system is presented. First, we devised a revised driving circuit for an emitter-coupled type buck converter, by which it is possible to reduce the material cost of transformers and voltage stress of power device. Secondly, we adopted a hybrid oscillation technique. When TV system is in off-stage, initial standby power which is necessary for remote controllable TV system is supplied by self-oscillating mode. Main power which is necessry in TV system bing on state is provided by an externally triggered oscillating mode. The switching frequency is synchronized to the oscillating frequency of horizontal deflection in TV, by which we can reduce picture noises and the size of power transformer. Thirdly, a simple error amplifier is inserted to the feed-back loop to keep the output voltage constant which means pulse width modulatio mode is added in driving part of power device. Finally, we showed by experiments that our proposed converter performs well enough to be close to the theoretically predicted values.

  • PDF

Reliability Models for Redundant Systems Using Phase-type Distributions

  • Moon, Sinmyeong;Lie, Changhoon
    • Management Science and Financial Engineering
    • /
    • v.7 no.2
    • /
    • pp.73-90
    • /
    • 2001
  • This paper presents the reliability models for redundant systems composed of repairable components whose failure time and repair time distributions are phase-type. It is shown that the distribution of time to system failure is also phase-type. The dependency between components are considered and integrated into the model by the used of the rate adjustment factor. The phase-type representation is constructed for the system through algebraic operations on the parameters of components\` failure time and repair time distributions and the corresponding rate adjustment factors. Types of system structures considered are parallel, k-out-of-N system with load sharing scheme and standby system with operation priority.

  • PDF

CONFIDENCE LIMITS FOR STEADY STATE AVAILABILITY OF A REDUNDANT SYSTEM

  • Shin, Sang-Wook;Lim, Jae-Hak;Park, Dong-Ho
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2000.04a
    • /
    • pp.193-200
    • /
    • 2000
  • In this paper, we consider confidence limits for steady state availability of a redundant structure with the function of switchover processing. The system considered in this paper consists of three units which are an active unit, a standby unit and a switchover device. A control module does not affect the performance of the system while the active unit is operating but causes the system failure if the active unit fails at the failure of the control module. The effect of failure of control module is included in our reliability model of the simple redundant structure. The availability of the system is obtained by using the state space method. An example is given to illustrate our results.

  • PDF

Reliability Analysis of the Man-Machine System Operating under Different Weather Conditions (기후조건을 고려한 인간-기계체계의 신속도)

  • 이길노;하석태
    • Journal of the military operations research society of Korea
    • /
    • v.23 no.1
    • /
    • pp.76-87
    • /
    • 1997
  • This paper deals with reliability and MTTF analysis of a non-repairable man-machine system operating under different weather conditions. The system consists of a hardware(machine) and a two-operator standby subsystem such as the air combat maneuvering of fighters with dual seat. The failure times for the subsystems follow the exponential distribution with constant parameter. By considering not only the effect on hardware component but also the weather conditions and human performance factors such as the operator's errors, a Markov model is presented as a method for evaluating the system reliability of time continuous operation tasks. Laplace transforms of the various state probabilities have been derived and then reliability of the system, at any time t, has been computed by inversion process. MTTF has also been computed.

  • PDF

Development of Ultrasonic Sensor for Engine Condition Diagnosis of EDG (비상디젤발전기 엔진 상태진단 초음파 탐촉자 개발)

  • Lee, Sang-Guk;Choi, Kwang-Hee
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.31-35
    • /
    • 2013
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear power plant at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite standby diesel generator should be ensured by a condition monitoring system designed to maintain, monitor and forecast the reliability level of diesel generator. The purpose of this paper is to improve the existing ultrasonic sensor used for condition diagnosis of engine fuel pump and cylinder head for the accurate diagnosis in actual engine condition of emergency diesel generator(EDG). As a result of this study, we could design and develop much more reliable ultrasonic sensor than existing ones.

Day-to-Day Repeatability of the Navigation Solution and SNR from the GPS Receiver installed on KSLV-I (나로호에 탑재된 GPS 수신기의 항법해와 신호대잡음비의 일반복 특성)

  • Kwon, Byung-Moon;Moon, Ji-Hyeon;Shin, Yong-Sul;Choi, Hyung-Don;Cho, Gwang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.8
    • /
    • pp.774-787
    • /
    • 2011
  • This paper deals with quantitative analysis about the characteristics of GNSS(Global Navigation Satellite System) signals contaminated with multipath signals and day-to-day repeatability of the navigation solution and SNR(Signal to Noise Ratio) caused by multipath signals using the collected data from GPS receiver installed on KSLV-I which was on standby on the launch pad at Naro Space Center. Since the GPS antennas, surrounding environments and GPS satellite orbits were very slightly changed with respect to the day, the repeating pattern of the solution and SNR caused by the multipath signals was verified from the collected data. Analytic result of the multipath effects and day-to-day repeatability of the navigation solution and SNR observed at the launch pad would be used for obtaining more stable performance of the GPS receiver when the satellite launch vehicles are on standby.

A Study on Smart Home Power-Control System with Power-Saving Green Adapter (전력절감 그린어뎁터를 이용한 스마트홈 전력 통제시스템)

  • Yoo, Seung-Jae;Park, Hee-Dong;Kim, Song-Gang
    • Convergence Security Journal
    • /
    • v.13 no.4
    • /
    • pp.85-92
    • /
    • 2013
  • Today we have an obligation to pass the beautiful earth and enrich people's lives to next generations. According to the keynote, governments have a lot of resources to support the smart grid policies. Also the demand of the implementation of smart home applied the concept of smart grid is increasing rapidly. But the construction of smart home is centered on a new public housing except the pre-existing house which is counted for most of more than 90% of total. In this study, we suggest the implementation solution to make smart-homelike for the pre-existing houses without additional wiring or construction. We develop the technology reducing the unnecessary standby power 800mW to 20mW drastically. If we apply this technology, by the power off of main IC the actual power depends on the consumption of minimal devise located on the AC input side. Then the standby power becomes approximately 20mW(110ac).

Development and Performance Analysis of an Effective Smart Plug System based on K10026 Regulation (K10026 기반 스마트 플러그 시스템 개발 및 성능 분석)

  • Chung, Han-Su;Lee, Hyung-Bong;Chung, Tae-Yun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.5
    • /
    • pp.287-298
    • /
    • 2016
  • This paper proposes an effective smart plug system capable of monitoring power, cutting off standby power and overload current. The key design concept is focused on measurement accuracy, self power consumption and controlling via smart phone application. The system is composed of several plugs and a hub, and adopts a star-topology-styled TDMA wireless protocol for communication between plug and hub. The test result shows that the implemented smart plug system meets K10026 regulation and is worth in electrical safety, energy saving, easy living.

Communication Redundancy for Reliability Improvement in an Industrial Monitoring and Control System

  • Rhyu, Keel-Soo;Chung, Kyung-Yul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1291-1298
    • /
    • 2004
  • In development of monitoring and control systems, one of the most important points is to consider a redundancy so that the system can be operated normally although hardware faults are partly occurred. The purpose of this paper is to introduce a monitoring and control system with a redundancy function for I/O servers and communication networks. I/O servers composed with an active server and a standby server. Each server also has 3 communication ports, 2 ports of them were connected to field units and the other 1 port was connected to the other server. Field units have to be constructed to 2 communication ports connected I/O servers through communication lines. Also, server communication module was implemented for analyzing and handling fault elements. and was submodularized for linking easily with a monitoring and control module. An experiment with 2 servers and 2 field units was constructed to demonstrate its effectiveness.