• Title/Summary/Keyword: Standardized protocol

Search Result 298, Processing Time 0.03 seconds

Clinical Outcomes of Ultrasound-Guided Subacromial Bursal Steroid Injection in Shoulder Impingement Syndrome (견관절 충돌 증후군에서 초음파하 견봉하 점액낭내 스테로이드 국소 주사의 임상적 결과)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Park, Bum-Suk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.68-73
    • /
    • 2009
  • Purpose: We retrospectively studied the outcomes of the shoulder impingement syndrome for the treatment of the ultrasound-guided subacromial bursal steroid injection. Materials and Methods: Sixty-six shoulders of sixty-two patients with shoulder impingement syndrome treated from March, 2006 to April, 2009 were involved in this study. All cases underwent standardized, nonoperative treatment protocol consisting of 5~12 MHz high resolution ultrasound-guided local steroid injection into the subacromial bursa in modified Crass position. The shoulder range of motion, VAS score and impingement signs were evaluated during the initial and 1year visits. After injection, shoulder elevation exercise was encouraged. Statistical analysis with ANOVA model and Tukey's post-hoc test with the significance level at 5% were performed using SAS program. Results: All cases showed improved range of motion without limitation of shoulder function at immediate post-injection, 6-week, 3-month and 1year visits. The average VAS score at one year follow-up decreased to 2.85 from 6.47 before injection. In all cases the impingement signs became negative immediate after injection. However, 6 cases showed positive impingement signs after 6-week, which became negative after reinjection. The range of motion and VAS score were improved at one-year follow-up compared to initial visit (p<0.0001). No complication was noted at all follow-up period. Conclusion: Ultrasound-guided subacromial steroid injection alleviated the need of surgery, because it was successful in all our cases to improve pain and function of the shoulders until one year follow-up period.

  • PDF

Report for Development of Korean Portable Cardiopulmonary Bypass II. Experimental Study of Portable Cardiopulmonary Bypass for Emergency Cardiopulmonary Resuscitation after Cardiac Arrest in Normal Dogs (한국형 이동식 심폐소생기 개발 보고 II. 응급소생술을 위한 이동식 심폐소생기의 동물 실험 연구)

  • Kim, Hyoung-Mook;Lee, In-Sung;Baek, Man-Jong;Sun, Kyung;Kim, Kwang-Taik;Lee, Hye-Won;Lee, Kyu-Back;Chang, Jun-Kuen;Kim, Chong-Won;Kim, Hark-Jei
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1147-1158
    • /
    • 1998
  • Background: Portable cardiopulmonary bypass(CPB) technique has been used increasingly as a potent and effective option for emergency cardiopulmonary resuscitation(CPR) because it can maintain more stable hemodynamics and provide better survival than conventional CPR techniques. This study was designed to develop a prototype of Korean portable CPB system and, by applying it to CPR, to discriminate whether it would be superior to standard open-chest CPR. Material and Method: By using adult mongrel dogs, open-chest CPR(OCPR group, n=4) and portable-CPB CPR(CPB group, n=4) were compared with respects to restoration of spontaneous circulation(ROSC), hemodynamics, effects on blood cells, blood gas patterns, biochemical markers, and survivals. Ventricular fibrillation-cardiac arrest(VF-CA) of arrest(VF-CA) of 4 minutes followed by basic life support(BLS) of 15 minutes was applied in either group, which was standardized by the protocol of American Heart Association. Then, advanced life support(ALS) was applied to either group under the support of internal cardiac massage or CPB. ALS was maintained until ROSC was achieved but not longer than 30 minutes regardless of the presence of ROSC. All of the measured values were expressed as means±SD percent change from baseline. Result: During the early ALS, higher mean arterial pressure was maintained in CPB group than in OCPR group(90±19 vs. 71±32 %; p<.05) and lower mean pulmonary arterial pressure was also maintained in CPB group than in OCPR group(105±24 vs. 146±6%; p<.05). ROSC was achieved in all dogs. Post-ROSC levels of hematocrit, RBC, and platelet were decreased and plasma free hemoglobin was increased significantly in CPB group compared to OCPR group(p<.05). Changes in blood gas patterns, lactate, and CK-MB levels were not different between groups. Early mortality was seen in 3 dogs in OCPR group(survival time 31±36 hours) and 2 in CPB group(228±153 hours, p=ns). The remainders in both groups showed prolonged survival. Conclusion: These findings indicate that portable CPB can be effective to maintain stable hemodynamics during cardiac arrest, to achieve ROSC and to prolong survival. Further study is needed to refine the portable CPB system and to meet clinical challenges.

  • PDF

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF

Nasal Continuous Positive Airway Pressure Titration and Time to Reach Optima1 Pressure in Sleep Apnea Syndrome (수면 무호흡 증후군에서 지속적 양압 치료시의 최적압 및 그 도달기간)

  • Lee, Kwan-Ho;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.1
    • /
    • pp.84-92
    • /
    • 1995
  • Background: Nasal applied continuous positive airway pressure(CPAP) is a highly effective method of treatment for obstructive sleep apnea syndrome. More than a decade of accumulated experience with this treatment modality confirmed that it is unquestionably the medical treatment of choice for patients with obstructive sleep apnea syndrome. However it takes long time to reach optimal CPAP pressure. To save the time to reach optimal pressure, it is necessary to clarify the time to reach optimal pressure for treatment of obstructive sleep apnea syndrome. Method: CPAP pressure is titrated during an overnight study according to a standardized protocol. Just before the presleep bio-calibration procedures, the technician applies the nasal mask and switches on the clinical CPAP unit. Initial positive for pressure is typically 3.0 centimeters of water pressure. After sleep onset, the technician gradually increases the pressure until sleep-disordered breathing events disappear or become minimal. The pressure must maintain maximal airway patency during both NREM and REM sleep to be considered effective. Before recommending a final pressure setting, sleep recording and oximetry data are reviewed by an American Board of Sleep Medicine certified Sleep Specialist and a Registrered Polysomnographic Technologist. Results: We examined the time required to reach optimal pressure during routine CPAP titration in 127 consecutively evaluated individuals diagnosed with sleep-disordered breathing. Results indicate that 33% of patients required more than four hours to attain satisfactory titration. This indicates that a four-hour session is marginally enough time, at best, to determine a proper CPAP pressure setting. Moreover, 60 of 127 patients required further adjustment after optimal pressure was reached. These additional pressure trials were needed to confirm that higher pressures were not superior for eliminating sleep-disordered breathing events. Conclusions: The data presented underscore the logistical difficulty of titrating CPAP during split-night studies without modifying the titration procedure. Futhermore, the time needed to reach optimal pressure makes it improbable that proper CPAP titration can be performed during a 2-3 hour nap study.

  • PDF

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

Corrections on CH4 Fluxes Measured in a Rice Paddy by Eddy Covariance Method with an Open-path Wavelength Modulation Spectroscopy (개회로 파장 변조 분광법과 에디 공분산 방법으로 논에서 관측된 CH4 플럭스 자료의 보정)

  • Kang, Namgoo;Yun, Juyeol;Talucder, M.S.A.;Moon, Minkyu;Kang, Minseok;Shim, Kyo-Moon;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.1
    • /
    • pp.15-24
    • /
    • 2015
  • $CH_4$ is a trace gas and one of the key greenhouse gases, which requires continuous and systematic monitoring. The application of eddy covariance technique for $CH_4$ flux measurement requires a fast-response, laser-based spectroscopy. The eddy covariance measurements have been used to monitor $CO_2$ fluxes and their data processing procedures have been standardized and well documented. However, such processes for $CH_4$ fluxes are still lacking. In this note, we report the first measurement of $CH_4$ flux in a rice paddy by employing the eddy covariance technique with a recently commercialized wavelength modulation spectroscopy. $CH_4$ fluxes were measured for five consecutive days before and after the rice transplanting at the Gimje flux monitoring site in 2012. The commercially available $EddyPro^{TM}$ program was used to process these data, following the KoFlux protocol for data-processing. In this process, we quantified and documented the effects of three key corrections: (1) frequency response correction, (2) air density correction, and (3) spectroscopic correction. The effects of these corrections were different between daytime and nighttime, and their magnitudes were greater with larger $CH_4$ fluxes. Overall, the magnitude of $CH_4$ flux increased on average by 20-25% after the corrections. The National Center for AgroMeteorology (www.ncam.kr) will soon release an updated KoFlux program to public users, which includes the spectroscopic correction and the gap-filling of $CH_4$ flux.

Report for Development of Korean Portable Cardiopulmonary Bypass Machine (한국형 이동식 심폐소생기 개발 보고 I. 실험견을 이용한 개흉식과 폐쇄식 심폐소생술 비교)

  • Kim, Hyoung-Mook;Lee, In-Sung;Baek, Man-Jong;Sun, Kyung;Kim, Kwang-Taik;Kim, Yeon-Soo;Kim, Maeng-Ho;Lee, Hye-Won;Lee, Kyu-Back;Kim, Hark-Jei
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.827-836
    • /
    • 1998
  • Background: Effective cardiopulmonary resuscitation (CPR) should provide acceptable hemodynamics for the vital organs during cardiac arrest and early restoration of spontaneous circulation that guarantees long-term, neurologically intact survival. CPR using heart-lung bypass has been suggested as an option for that use. This study was designed to determine the effectiveness of standard CPR techniques, closed-vs. open-chest CPR, which could be used in the future study verifying the role of heart-lung bypass CPR. Material and Method: By using adult mongrel dogs, closed-chest CPR (CCCPR, n=4) and open-chest CPR (OCCPR, n=5) were compared with respects to hemodynamics, restoration of spontaneous circulation(ROSC), and survival. Ventricular fibrillation-cardiac arrest (VF-CA) was induced by electrical shock in all animals. After 4 minutes of cardiac arrest, basic life support (BLS) was applied for 15 minutes and followed by advanced life support (ALS). ALS was maintained until achi ving ROSC but not longer than 30 minutes regardless of the recovery. Resuscitation procedures in either group were standardized by adopting the protocol of American Heart Association. Result: Prearrest baseline hemodynamic data was not different between two groups. During resuscitation, substantially higher systolic pressure was maintained in OCCPR group than in CCCPR group (45$\pm$15 vs. 33$\pm$11 mmHg during BLS, 83$\pm$36 vs. 44$\pm$15 mmHg during ALS; p=NS). Mean pulmonary arterial pressure went up to the level of mean systemic arterial pressures in CCCPR group and to half of that in OCCPR group, and had kept higher in CCCPR group throughout CPR (32$\pm$10 vs. 22$\pm$4 mmHg during BLS and 32$\pm$15 vs. 24$\pm$10 mmHg during ALS; p=NS). ROSC was obtained in 4 of 5 dogs receiving open-chest CPR and 2 of 4 closed-chest CPR. Prolonged survival was noted in all dogs in OCCPR group (6 to 1440 hours) but not in CCPR group (p<.05). Conclusion: These findings indicate that open-chest CPR can be more effective t maintain hemodynamics during cardiac arrest and to obtain restoration of spontaneous circulation and survival. Further experiment will be designed to compare heart-lung bypass CPR with open-chest CPR.

  • PDF

Predicting Oxygen Uptake for Men with Moderate to Severe Chronic Obstructive Pulmonary Disease (COPD환자에서 6분 보행검사를 이용한 최대산소섭취량 예측)

  • Kim, Changhwan;Park, Yong Bum;Mo, Eun Kyung;Choi, Eun Hee;Nam, Hee Seung;Lee, Sung-Soon;Yoo, Young Won;Yang, Yun Jun;Moon, Joung Wha;Kim, Dong Soon;Lee, Hyang Yi;Jin, Young-Soo;Lee, Hye Young;Chun, Eun Mi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.6
    • /
    • pp.433-438
    • /
    • 2008
  • Background: Measurement of the maximum oxygen uptake in patients with chronic obstructive pulmonary disease (COPD) has been used to determine the intensity of exercise and to estimate the patient's response to treatment during pulmonary rehabilitation. However, cardiopulmonary exercise testing is not widely available in Korea. The 6-minute walk test (6MWT) is a simple method of measuring the exercise capacity of a patient. It also provides high reliability data and it reflects the fluctuation in one' s exercise capacity relatively well with using the standardized protocol. The prime objective of the present study is to develop a regression equation for estimating the peak oxygen uptake ($VO_2$) for men with moderate to very severe COPD from the results of a 6MWT. Methods: A total of 33 male patients with moderate to very severe COPD agreed to participate in this study. Pulmonary function testing, cardiopulmonary exercise testing and a 6MWT were performed on their first visits. The index of work ($6M_{work}$, 6-minute walk distance [6MWD]${\times}$body weight) was calculated for each patient. Those variables that were closely related to the peak $VO_2$ were identified through correlation analysis. With including such variables, the equation to predict the peak $VO_2$ was generated by the multiple linear regression method. Results: The peak $VO_2$ averaged $1,015{\pm}392ml/min$, and the mean 6MWD was $516{\pm}195$ meters. The $6M_{work}$ (r=.597) was better correlated to the peak $VO_2$ than the 6MWD (r=.415). The other variables highly correlated with the peak $VO_2$ were the $FEV_1$ (r=.742), DLco (r=.734) and FVC (r=.679). The derived prediction equation was $VO_2$ (ml/min)=($274.306{\times}FEV_1$)+($36.242{\times}DLco$)+($0.007{\times}6M_{work}$)-84.867. Conclusion: Under the circumstances when measurement of the peak $VO_2$ is not possible, we consider the 6MWT to be a simple alternative to measuring the peak $VO_2$. Of course, it is necessary to perform a trial on much larger scale to validate our prediction equation.