• Title/Summary/Keyword: Standardized patient

Search Result 423, Processing Time 0.023 seconds

Usefulness Evaluation of Open Mouth View when PET/CT scan In Tongue Cancer Patients (Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가)

  • Kim, Jae Hwan;Yun, Jong Jun;Jung, Ji Wook;Kim, Jung Wook;Hwang, Ju Won;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.14-20
    • /
    • 2016
  • Purpose Tongue cancer is 1.8% of all cancer tumors occur in the tongue, it is known that the high incidence enough to account for 75% of oral cancer conducted a PET / CT examination for early diagnosis, metastasis, staging, etc. and. Tongue when PET / CT scan of a cancer patient and a Torso taken to close mouth lesions if the condition was caused due to the overlapping or corresponding artifacts are not clearly observed. The purpose of this study is to evaluate the changes that occur during PET / CT scan with open mouth and its usefulness under. Materials and Methods From June 2015 to March 2016 complained of herein by May 21 had received a diagnosis of tongue cancer underwent PET / CT scan patients were treated with a target (16 males, 5 female). The first was taken to close mouth Torso state, it was taken to add 1 bed open mouth condition. Tumor (T), measuring the Normal Tongue (NT), Lymph Node (LN) standard intake coefficient by setting a region of interest in the (standardized uptake value, SUV) SUVmean, the average value was measured SUVmax, drawn to each region of interest 3 times and Background (Carotid artery) was out of the SUV. In Chapter 3 of the slice to the tumor clearly visible by setting the region of interest to measure the change Tumor size was calculated average value. Gross Image resolution assessment were analyzed statistically through were divided into 1-5 points by the Radiation 7 people in 2, more than five years worked in specialized nuclear medicine compare to proceed with the blind test nonparametric test (wilcoxon signed rank test). (SPSS ver.18) Results $SUV_{mean}$ T's were in close mouth $5.01{\pm}2.70$ with open mouth $5.48{\pm}2.88$ (P<0.05), $SUV_{max}$ were respectively $8.78{\pm}5.55$ and $9.70{\pm}5.99$ (P<0.05). $SUV_{mean}$ in the NT were respectively $0.43{\pm}0.30$ and $0.34{\pm}0.24$ (P=0.20), $SUV_{max}$ was $0.56{\pm}0.34$ and $0.45{\pm}0.25$ (P=0.204). LN $SUV_{mean}$ were respectively $1.62{\pm}1.43$ and $1.69{\pm}1.49$ (P=0.161), $SUV_{mean}$ was $2.09{\pm}1.88$ and $1.99{\pm}1.74$ (P=0.131). Tumor size change is close mouth $4.96{\pm}4.66cm^2$ $5.33{\pm}4.64cm^2$ with 7.45% increase was (P<0.05), gross image resolution evaluation is $2.87{\pm}0.73$, $3.77{\pm}0.68$ with open mouth examinations 30.5% increase was (P<0.05). Conclusion Tumor SUV on the changes that had an increase in open mouth during inspection, the normal tongue and lymph node, but there was no significant difference in the change slightly. It is also one open mouth PET / CT scan will provide improved image to all patients with tongue cancer, but it could be confirmed that similar overall through the blind test, or tumor size changes and showing a high resolution image. It can be the perfect alternative method for problems that occur when the close mouth Open mouth PET / CT scan, but is believed to be through the open mouth to observe the boundary of overlapping or tumor of the oral cavity other structures a little more clearly. Tongue cancer patients how to recommend that the shooting further open mouth PET / CT.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

A Study of Changes of Pulmonary Artery Size after Bidirectional Cavopulmonary Shunt (양방향성 상대정맥-폐동맥 단락술 후의 폐동맥 크기 변화에 관한 연구)

  • 지현근;이정렬
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.495-503
    • /
    • 1996
  • The bidirectional cavopulmonary shunt may be useful as an intermediate procedure before Fontal oper- ation in high-risk patients, because it provides adequate relief of cyanosis and relief of ventricular volume overload. But there are no established theory about the effects of bidirectional cavopulmonary shunt on pulmonary arterial development. The purpose of this article is a study of changes of pulmonary artery size after bidirectional cavopulmonary shunt. Ca diac catheterization and angiography procedures were done on 19 patients who underwent bidirectional cavopulmonary shunt from February 1992 to July 1994, their results were reviewed. Preoperative cardiac catheterization and angiography procedures were performed at a mean interval of ).8 $\pm$4.8($\pm$SEM) months before surgery and following catheterization at a mean postoperative interval of 19.6 $\pm$4.8 months. Pulmonary arterial sixte measurement were standardized for body surface area(Pulmon- arty artery index), and for diameter of descending thoracic aorta(McGoon ratio). Patient's age, body stir- face area, pulmonary angioplasty, preoperative McGoon ratio and follow-up intervals were considered as variables. Before bidirectional cavopulmonary shunt, patient's mean age, body surface area, arterial 02 saturation, diameter of right pulmonary artery, diameter of left pulmonary artery, pulmonary artery Index, McGoon ratio were 13.7$\pm$15.6 months, 0.40$\pm$0.12m2, 71.4$\pm$12.4m2, 7.1$\pm$1.7mm, 6.2$\pm$1 , 191.8$\pm$82.7mm21m2, 1.73 $\pm$0.49, respectively. After bidirectional cavopulmonary shunt, the values were changed to 39.9 $\pm$ 16.2 months, 0.58$\pm$0.07 m2, 83.0$\pm$3.8m2, 9.0$\pm$ 1.5 mm, 7.7$\pm$2.0, 197.3$\pm$57.1 mm2/m2, 1.76$\pm$0.32, respect- ively With patients'development (age, body surf'ace area), diameters of pulmonary arteries were increased, but pulmonary artery indices and McGoon ratios were not changed. And there were no effects of age, body surf'ace area, amount of increased 02 saturation, pulmonary angiography and follow-up duration on the increment of pulmonary ar- tery size. But when the McGoon ratio was as low as 1.2, there were significant increase in postoperative pulmonary artery sizes. There was a significant correlation between preoperative pulmonary artery index (PAI) and McGoon ratio (MGR) ; PAI : MGRxl18.0-12.4 In conclusion, bidirectional cavopulmonary shunt provides adequate increment of arterial 02 saturation and does not increase the pulmonary artery size. Further investi ation is mandatory to evaluate the effect of pulsatile bidirectional cavopulmonary shunt on pulmonary artery growth.

  • PDF

Evaluation of SUV Which was Estimated Using Mini PACS by PET/CT Scanners (PET/CT 장비 별 mini PACS에서 측정한 표준섭취계수(SUV)의 유용성 평가)

  • Park, Seung-Yong;Ko, Hyun-Soo;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.47-52
    • /
    • 2011
  • Purpose: Facilities use own sever or mini PACS system for storage and analysis of the PET/CT data. Mini PACS can storage scan data as well as measuring SUV. Therefore, the study was performed to confirm whether or not measured SUV on mini PACS is measured equally on PET/CT workstation. Materials and Methods: In February 2011, 30 patients who were performed $^{18}F$-FDG wholebody PET/CT scan in Biograph 16, Biograph 40 and Discovery Ste 8 were enrolled. First, using each workstation, SUV in liver and aorta of mediastinum level was measured. Second, using mini PACS, SUV was measured by same method. Result: The correlation coefficient of SUV in liver between PET/CT scanner and min PACS in Biograph 16, Biograph 40, Discovery Ste 8 was 0.99, 0.98, 0.64 respectably, the correlation coefficient of SUV in aorta was 0.98, 0.98, 0.66, and these were showed positive correlation coefficient. Difference of SUV between Biograph workstation and mini PACS was not showed statistical significant difference at 5% level of significance. Difference of SUV between Discovery Ste 8 workstation and mini PACS was showed statistical significant difference at 5% level of significance. Conclusion: In case that patient was scanned by the other scanner, if the correction of SUV formula in mini PACS for each scanners is performed, mini PACS will be usefully used to provide consistently quantitative assessment.

  • PDF

THE STUDY ON RELATIONSHIP BETWEEN PSYCHOPATHOLOGY AND NEUROLOGICAL FACTORS IN CHRONIC EPILEPTIC CHILDREN (경련 질환 환아의 정신병리와 신경학적 요인과의 관계에 대한 연구)

  • Kim, Bung-Nyun;Cho, Soo-Churl;Hwang, Yong-Seung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.7 no.1
    • /
    • pp.92-109
    • /
    • 1996
  • The objectives of the present study were to provide comprehensive assessment of the impact of epilepsy on the psychological well-being of children with epilepsy and to identify the neurological factors associated with the psychopathology. The participant patients were recruited from the population of children and adolescent aged 7 to 16 attending the OPD of department of pediatric neurology in Seoul National University Hospital in Korea. We exclude mental retardation, pervasive developmental disorder and brain organic pathology. As control group, formal students were chosen and their sex, age, achievement, socioeconomic status were matched to patients. The first author interviewed the children and their family members and obtained the developmental history and family information. We used the following 10 scales for assessing psychological and behavioral problems in patients and their family member. The scales were standardized and their validity and reliability were confirmed before. Parent rating scales : Yale children's inventory, Disruptive behavior disorder scale, Parent's attitude to epilepsy questionnaire, Family environment scale, Symptom check-list-90 revision, Children behavior check-list. Children's self rating scales : Children's depression inventory, Spielberger's state-trait anxiety anxiety, Piers-Harris self-concept inventory and Self-administered Dependency questionnaire for Mother. The result showed the risk factors associated depression were early onset, complex partial seizure, lateralized temporal focal abnormality on EEG, Drug polypharmacy, high seizure frequency and sick factors associated anxiety were old age of patient, lateralized temporal focal abnormality EEG, Drug polypharmacy, high seizure frequency. Also the result of this present study indicated that risk factors associated oppositional defiant disorder, conduct disorder and attention deficit hyperactivity disorder were young age, male, early onset, lateral temporal EEG abnormality and high seizure frequency. According to these results, common risk factors associated psychological and behavioral problems were lateralized EEG temporal abnormality, high seizure frequency in neurological factors.

  • PDF

Study on the Growth of the Aortic Aannulus. Root, and Anastomosis After Arterial Switch Operation in Infancy (영아기에 시행한 동맥전환술 후의 대동맥판륜, 근부, 및 문합부위 성장에 관한 연구)

  • 이정렬;박정준
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.479-485
    • /
    • 1997
  • We investigated changes of the size of neoaortic annulus, root, and aortic anastomosis after arterial switch operation for complete transposition of the great arteries performed in infancy. A total of 23 patients were included in this study. Age ranged from 6 to 153 days. Body weight averaged 3.9$\pm$0.8kg and 17 patients were male. The preoperative angiocardiographic dimensions of the pulmonary annulus, the pulmonary root, and the sinotubular junction, standardized to the diameter of descending aorta at the level of diaphragm, were compared to the size of postoperative measurements of the neoaortic annulus, the neoaortic root, and the aortic an stomosis at a mean interval of 17.2$\pm$ 9.4 months. Mean dimensions of the neoaortic annulus and the neoaortic root were significantly increased postoperatively(n=23, annulus; p<0.01, root; p<0.01), however, those of the aortic anastomosis did not reveal significant change(n=23, p=0.06). There were no significant differences in changes of diameters of the neoaortic annulus, the root, and the aortic anastomosis between patients with(n=8) and without(n=15) postoperative neoaortic regurgitation(annulus; p=0.32, root; p=0.29, anastomosis; p=0.86). Postoperative dimensions of the neoaortic root and annulus between patients with ventricular septal defect(n: 10) and without ventricular septal defect(ni 13) were not significantly changed compared to the preoperative measurements(annulus; p=0.09, root; p=0.07) but mean diameters of the aortic anastomosis decreased significantly after operation in patients with ventricular septal defect(p=0.04). This study revealed that the site of the aortic an stomosis grows in proportion to patient's somatic growth after arterial switch operation. Although we could not demonstrate the relation between the aortic root dilatation and the postoperative neoaortic regurgitation in this study, a continuous close follow-up might be necessary to detect a possible progression of the aortic root dilatation and the resulting significant aortic valve regurgitation.

  • PDF

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

Prevalence and Management of Dyslipidemia, Hypertension, Diabetes Among Adults in Gangwon-do, Korea: the 2013-2014 KNHSP (강원도 성인의 이상지질혈증, 고혈압, 당뇨병의 유병률과 관리: 국가건강검진(2013-2014) 자료의 분석결과와 시사점)

  • Jang, Sungok;Lee, Jongseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.625-636
    • /
    • 2017
  • Dyslipidemia, hypertension, and diabetes are well-established risk factors for cardio-cerebrovascular disease (CVD). Although the prevalence of dyslipidemia among Korean adults is very high, its management is known to be poor. The aim of this study was to assess the prevalence, awareness, treatment, and control rates of dyslipidemia among adults aged 30 years and older in Gangwon-do, Korea. Analysis included 58,121 adults (29,123 males and 28,998 females) participating in the 2013-2014 Korea National Health Screening Program (KNHSP). Dyslipidemia was defined according to the treatment criteria rather than the diagnostic criteria in Korea. Therefore, high-low-density lipoprotein cholesterol (LDL)-cholesterolemia was deemed present in individuals with LDL-cholesterol levels that exceeded the appropriate risk-based threshold. The age-standardized prevalence was highest in dyslipidemia (32.5%), followed by hypertension (25.1%), and diabetes (9.4%). The awareness rate was 76.7% for hypertension and 74.7% for diabetes, but only 10.6% for dyslipidemia. The lowest patient treatment was found for dyslipidemia (9.4%). The control rate among those undergoing treatment was highest for hypertension (75.8), followed by dyslipidemia (63.3%), and diabetes (43.9%). The higher CVD-risk categories showed lower control rates of hyper-LDL-cholesterolemia. The prevalence of dyslipidemia was higher than hypertension and diabetes, but awareness and treatment rates were lower. Our findings indicate there is a wide gap between the prevalence of dyslipidemia and subsequent treatment, which suggests that effective strategies are required to improve dyslipidemia management. It would be worthwhile to strengthen the follow-up management of patients with dyslipidemia in the KNHSP, especially for the high risk group of CVD.

Comparison of Myogenous and Arthrogenous Pain Patients of Temporomandibular Disorders using Research Diagnostic Criteria for Temporomandibular Disorders (측두하악장애 연구진단기준(RDC/TMD)를 이용한 측두하악장애의 근육성 동통과 관절성 동통 환자군의 비교)

  • Park, Joo Sun;Kim, Dong Hee;Chung, Jin Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.4
    • /
    • pp.233-242
    • /
    • 2012
  • The purposes of this study were to compare psychological profiles, to investigate the differences in the clinical characteristics, and to compare treatment outcomes between myogenous pain and arthrogenous pain subgroups of temporomandibular disorder (TMD) based on Research Diagnostic Criteria for Temporomandibular disorders (RDC/TMD). Two hundred and fifty two patients diagnosed as TMD were divided into three groups based on the RDC/TMD axis I diagnostic guidelines; myogenous pain group, arthrogenous pain group, and mixed pain (both myogenous pain and arthrogenous pain) group. RDC/TMD history questionnaire was administered to each patient and depression, somatization, jaw disability, pain intensity, disability days, and graded chronic pain scale were analyzed. Bruxism, clenching, insomnia, headache, and unilateral chewing were assessed in a standardized TMD dysfunction questionnaire and the duration of onset, chronicity of pain, treatment period, the effectiveness of the treatment, and improvement of symptoms also analyzed. Myogenous pain group had higher depression (p=0.002), and somatization scales (p<0.001) than the arthrogenous pain group. Mixed pain group showed higher pain intensity (p=0.008), disability days (p<0.001), graded chronic pain scale (p=0.005), somatization (p<0.001), and depression scores (p=0.002) than the arthrogenous pain group. Jaw disability did not show any significant differences among the three groups (p=0.058). Arthrogenous pain group reported more limitation of mouth opening than myogenous pain group (p=0.007). Duration of onset showed that the arthrogenous pain group had lowest prevalence of chronicity among three groups (p=0.002). Mixed pain group patients showed lowest symptom improvements among three groups (p=0.007). Multiple linear regression analysis results showed that the treatment effectiveness was significantly associated with somatization score (${\beta}$=-0.251, p=0.03).