• Title/Summary/Keyword: Standardization System

Search Result 1,779, Processing Time 0.028 seconds

Standardization of Enhanced Flight Termination System in the U.S. (미국의 차세대 비행종단시스템 표준화 동향)

  • Bae, Young-Jo;Oh, Chang-Yul;Lee, Hyo-Keun
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.8 no.1
    • /
    • pp.86-95
    • /
    • 2010
  • Flight termination system(FTS) is used to terminate safely the launch vehicle's flight when it faces an emergency situation by transmitting termination command from ground FTS. RCC standard IRIG tone method has been used widely for FTS commands method in foreign ranges and Naro Space Center, but this method has a weakness for security of command signal. Therefore RCC had studied more secured EFTS standard and chose CPFSK digital modulation method. This paper describes basic concept and types of FTS and FTS types which foreign ranges had applied and describes standardization of EFTS in the U.S. based on RCC EFTS study reports.

  • PDF

Flow Characteristics of a Primary Cooling System in 5 MW Research Reactor (5MW 연구용 원자로의 1차 냉각 계통 유동 특성)

  • Park, Young-Chul;Lee, Young-Sub
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.5
    • /
    • pp.5-10
    • /
    • 2010
  • 5MW, open pool type research reactor, is commonly used to education and experimental purpose. It is necessary to prepare a standardization of system designs for considering a demand. HANARO has prepared the standardization of 5MW research reactor system designs based on the design, installation, commissioning and operating experiences of HANARO. For maintaining an open pool type reactor safety, a primary cooling system (after below, PCS) should remove the heat generated by the reactor under a reactor normal operation condition and a reactor shutdown condition. For removing the heat generated by the reactor, the PCS should maintain a required coolant flow rate. For a verification of the required flow rate, a flow network analysis of the PCS was carried under a normal operating condition. Based on the flow network analysis result, this paper describes the PCS flow characteristics of a 5MW open pool type research reactor. Through the result, it was confirmed that the PCS met design requirements including design flow rate without cavitation.

The standardization directions on integrated distribution information management system of agricultural products (농산물 통합유통정보관리시스템 표준화 추진 방향)

  • Min, J.H.;Huh, M.Y.;Park, J.Y.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.617-620
    • /
    • 2016
  • It is necessary to propose the plans for achieving a stable supply and enhanced distribution efficiency based on the cooperative integration system in the aspects of product logistics information cash flow among the entities of the entire supply chain in order to overcomes the limitations of separate and independent distribution and logistics management system and solve the instability problems of supply & price in Domestic agricultural products distribution sector. Therefore, this paper looks over the problems of information management system in agricultural distribution process and proposes the reference standard model and the standardization plans for information structure on the agricultural products integrated distribution information system.

  • PDF

A Study on the Standardization of Operation System for Road Tunnels (터널운영시스템 표준화 연구)

  • Kim, Tae-Hyung;Kim, Jin;Keum, Jae-Sung;Tae, Jae-Ho;Kim, Sun-Hong;Hong, Dae-Hie
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.75-79
    • /
    • 2008
  • Since tunnel construction order was placed one by one, various sensors and actuators installed at the RTU and higher level system in each tunnel maintenance office had their own protocols depending on construction company. The TGMS testbed established on the extended region of Yong-dong Highway, for example, did not have consistent protocol between each automation levels and management levels without considering the functions and/or roles of each level. The management sever in each tunnel was simply networked to the TGMS server. Therefore, it is impossible to implement a new control algorithm as well as to integrate each other since each tunnel was constructed by different company. So, if the construction company is out of business, there is no way to maintain the corresponding tunnel effectively. In order to solve this problem, all the necessary standard protocols was established between automation level and management levels. These interface standards provide the clear classification between individual tunnel system and tunnel management system. So, even if construction company is different, its effect is minimized, so that it is expected to successfully establish PC based TGMS.

  • PDF

Johnson BV standardization of 60cm telescope at Gyeonggi Science High School for the Gifted

  • Ahn, Hojae;Oh, Seungjun;Lee, Hyundong;Park, Woojin;Lee, Ho;Kim, Hyunjong;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.66.4-67
    • /
    • 2020
  • Gyeonggi science high school for the gifted (GSHS) installed 60cm telescope, which is waiting for student observers. It is essential to understand the characteristics of the photometric system, consisting of telescope, filter, and CCD, to get reliable data. CCD images of SA98 Landolt standard field and M67 were obtained on 19th March 2020. The images of each field were combined by filters, i.e., we ignored the monochromatic atmospheric extinction since the photometric objects themselves are standard stars. 24 standard stars in SA98 field and 12 standard stars in M67 were used to derive the tentative transformation equation between our bv photometric system and Johnson BV photometric system. In this poster, we present the preliminary standardization result for Johnson BV photometric system in GSHS 60cm telescope. The reproductivity is discussed by comparing color coefficients of two fields. We plan to extend this process to Johnsons-Cousins BVRI photometric system and narrow-band filters for flux calibration.

  • PDF

A Comparative Analysis of Public Warning Systems by Countries to Improve Public Warning System (공공경보시스템 개선을 위한 국가별 공공경보시스템 비교분석 연구)

  • WU, ZHOU;Kim, Jae Young;An, Byung Dae
    • The Journal of Information Systems
    • /
    • v.32 no.3
    • /
    • pp.183-203
    • /
    • 2023
  • Purpose The purpose of this study is to examine the current operational status and problems of the Public Warning System (PWS) in China, and to propose feasible solutions to improve the performance and efficiency of the PWS through a comparative analysis with the Cell Broadcast Service (CBS)-based disaster SMS system adopted by other developed countries in the world. Design/methodology/approach In this study, the characteristics of PWS using SMS, applications, and CBS, respectively, are analyzed in detail, and compared and analyzed in terms of convenience, standardization, data security, speed, and location accuracy. In addition, CBS-based PWS in developed countries, such as U.S., E.U., Korea and Japan, were studied and their performance on key criteria was evaluated. Findings Based on the results of the study, the problems of China's PWS are summarized and recommendations are made to improve the PWS through the introduction of CBS technology. To this end, specific improvement measures are proposed in terms of the application of CBS technology, system construction and operation, and improvement of data security. In addition, the comparative analysis of PWSs in other developed countries is conducted to provide reference for the direction of PWS's improvement.

Stem-leaf saponins from Panax notoginseng counteract aberrant autophagy and apoptosis in hippocampal neurons of mice with cognitive impairment induced by sleep deprivation

  • Cao, Yin;Yang, Yingbo;Wu, Hui;Lu, Yi;Wu, Shuang;Liu, Lulu;Wang, Changhong;Huang, Fei;Shi, Hailian;Zhang, Beibei;Wu, Xiaojun;Wang, Zhengtao
    • Journal of Ginseng Research
    • /
    • v.44 no.3
    • /
    • pp.442-452
    • /
    • 2020
  • Backgroud: Sleep deprivation (SD) impairs learning and memory by inhibiting hippocampal functioning at molecular and cellular levels. Abnormal autophagy and apoptosis are closely associated with neurodegeneration in the central nervous system. This study is aimed to explore the alleviative effect and the underlying molecular mechanism of stem-leaf saponins of Panax notoginseng (SLSP) on the abnormal neuronal autophagy and apoptosis in hippocampus of mice with impaired learning and memory induced by SD. Methods: Mouse spatial learning and memory were assessed by Morris water maze test. Neuronal morphological changes were observed by Nissl staining. Autophagosome formation was examined by transmission electron microscopy, immunofluorescent staining, acridine orange staining, and transient transfection of the tf-LC3 plasmid. Apoptotic event was analyzed by flow cytometry after PI/annexin V staining. The expression or activation of autophagy and apoptosis-related proteins were detected by Western blotting assay. Results: SLSP was shown to improve the spatial learning and memory of mice after SD for 48 h, accomanied with restrained excessive autophage and apoptosis, whereas enhanced activation of phosphoinositide 3-kinase/protein kinase B/mammalian target of rapamycin signaling pathway in hippocampal neurons. Meanwhile, it improved the aberrant autophagy and apoptosis induced by rapamycin and re-activated phosphoinositide 3-kinase/Akt/mammalian target of rapamycin signaling transduction in HT-22 cells, a hippocampal neuronal cell line. Conclusion: SLSP could alleviate cognitive impairment induced by SD, which was achieved probably through suppressing the abnormal autophagy and apoptosis of hippocampal neurons. The findings may contribute to the clinical application of SLSP in the prevention or therapy of neurological disorders associated with SD.

Improvement of Diagnostic Accuracy by Standardization in Diuretic Renal Scan (소아 이뇨 신장스캔에서 검사 표준화에 의한 폐쇄 진단 성능 향상)

  • Hyun, In-Young;Lee, Dong-Soo;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Kwang-Myung;Choi, Hwang;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.497-503
    • /
    • 1995
  • We evaluated diagnostic accuracy of diuretic renal scan with standardization in 45 childrens(107 hydronephrotic kidneys) with 91 diuretic assessments. Sensitivity was 100%, specificity was 78%, and accuracy was 84% in 49 hydronephrotic kidneys with standardization. Diuretic renal scan without standardization, sensitivity was 100%, specificity was 38%, and accuracy was 57 % in 58 hydronephrotic kidneys. The false-positive results were observed in 25 cases without standardization, and in 8 cases with standardization. In diuretic renal scans without standardization, the causes of false-positive results were 10 early injection of lasix before mixing of radioactivity in pelvocalyceal system, 4 full bladder, 2 markedly dilated pelvocalyceal systems postpyeloplsty, 6 extrarenal pelvis, and 3 immature kidneys of neonates. In diuretic renal scans with standardization the causes of false-positive results were 2 markedly dilated systems postpyeloplsty, 2 extrarenal pelvis, 1 immature kidney of neonate, and 2 severe venal dysfunction, 1 vesicoureteral reflux. In diuretic renal scan without standardization the false-positive results by inadequate study were common, but false-positive results by inadequate study were not found after standardization. The false-positive results by dilated pelvocalyceal systems postpyeloplsty, extrarenal pelvis, and immature kidneys of neonates were not dissolved after standardization. In conclusion, diagnostic accuracy of diuretic renal scan with standardization was useful in children with renal outflow tract obstruction by improving specificity significantly.

  • PDF