• 제목/요약/키워드: Standard unit cost

검색결과 197건 처리시간 0.029초

Effect of Chlorhexidine Mouthrinse on Prevention of Microbial Contamination during EBUS-TBNA: A Study Protocol for a Randomized Controlled Trial

  • Kim, Na Young;Park, Jae Hyeon;Park, Jimyung;Kwak, Nakwon;Choi, Sun Mi;Park, Young Sik;Lee, Chang-Hoon;Cho, Jaeyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • 제84권4호
    • /
    • pp.291-298
    • /
    • 2021
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard diagnostic method for mediastinal and hilar lymphadenopathy. Although rare, fatal infectious complications can occur following EBUS-TBNA. However, to date, there is a lack of effective preventive strategies to reduce these complications. We started a trial to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Methods: This study is a single-center, parallel-group, assessor-blinded randomized controlled trial (RCT). We will enroll 112 adult participants undergoing EBUS-TBNA using a convex probe, and randomly assign them to two groups at a 1:1 ratio. The intervention group will gargle for 1 minute with 100 mL of 0.12% chlorhexidine gluconate before EBUS-TBNA, while the control group will have no mouthrinse before the procedure. Immediately after completion of EBUS-TBNA on all targeted lesions with an aspiration needle, a needle wash sample will be taken by instilling 5 mL of sterile saline into the used needle. The primary outcome is colony forming unit (CFU) counts in aerobic cultures of the needle wash samples. Secondary outcomes are CFU counts in anaerobic cultures, fever within 24 hours after EBUS-TBNA, and infectious complications within 4 weeks after EBUS-TBNA. Conclusion: This trial was designed as the first RCT to investigate the effect of chlorhexidine mouthrinse on the prevention of microbial contamination during EBUS-TBNA. Results from this trial can provide clinical evidence for a simple, safe, and cost-effective strategy to prevent infectious complications following EBUS-TBNA (ClinicalTrials.gov ID: NCT04718922, registered on 22 January 2021).

Machine Learning Model to Predict Osteoporotic Spine with Hounsfield Units on Lumbar Computed Tomography

  • Nam, Kyoung Hyup;Seo, Il;Kim, Dong Hwan;Lee, Jae Il;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.442-449
    • /
    • 2019
  • Objective : Bone mineral density (BMD) is an important consideration during fusion surgery. Although dual X-ray absorptiometry is considered as the gold standard for assessing BMD, quantitative computed tomography (QCT) provides more accurate data in spine osteoporosis. However, QCT has the disadvantage of additional radiation hazard and cost. The present study was to demonstrate the utility of artificial intelligence and machine learning algorithm for assessing osteoporosis using Hounsfield units (HU) of preoperative lumbar CT coupling with data of QCT. Methods : We reviewed 70 patients undergoing both QCT and conventional lumbar CT for spine surgery. The T-scores of 198 lumbar vertebra was assessed in QCT and the HU of vertebral body at the same level were measured in conventional CT by the picture archiving and communication system (PACS) system. A multiple regression algorithm was applied to predict the T-score using three independent variables (age, sex, and HU of vertebral body on conventional CT) coupling with T-score of QCT. Next, a logistic regression algorithm was applied to predict osteoporotic or non-osteoporotic vertebra. The Tensor flow and Python were used as the machine learning tools. The Tensor flow user interface developed in our institute was used for easy code generation. Results : The predictive model with multiple regression algorithm estimated similar T-scores with data of QCT. HU demonstrates the similar results as QCT without the discordance in only one non-osteoporotic vertebra that indicated osteoporosis. From the training set, the predictive model classified the lumbar vertebra into two groups (osteoporotic vs. non-osteoporotic spine) with 88.0% accuracy. In a test set of 40 vertebrae, classification accuracy was 92.5% when the learning rate was 0.0001 (precision, 0.939; recall, 0.969; F1 score, 0.954; area under the curve, 0.900). Conclusion : This study is a simple machine learning model applicable in the spine research field. The machine learning model can predict the T-score and osteoporotic vertebrae solely by measuring the HU of conventional CT, and this would help spine surgeons not to under-estimate the osteoporotic spine preoperatively. If applied to a bigger data set, we believe the predictive accuracy of our model will further increase. We propose that machine learning is an important modality of the medical research field.

조경관리 민간위탁용역의 입찰추이에 관한 연구 (A Study on the Bidding Trends of the Private Consignment Service of Landscape Management)

  • 황대진;김동필;문호경
    • 한국조경학회지
    • /
    • 제47권1호
    • /
    • pp.39-48
    • /
    • 2019
  • 본 연구는 점차적으로 늘어나고 있는 조경관리 민간위탁용역의 입찰추이를 조달청 나라장터의 입찰자료(2003~2015)를 바탕으로 입찰에 필수적인 항목을 선별하여 총 입찰별, 유형별, 발주처별, 지역별, 종목별 등으로 분류하여 입찰건수 및 금액별로 조사 및 분석하였으며, 결과는 다음과 같다. 첫째, 조경관리 민간위탁용역의 총 입찰건수는 10여 년간 1,112건의 증가와 487.7%의 증가율로 나타났고, 총 입찰금액의 경우는 144,504백만 원의 증가와 382.5%의 증가율이 나타났다. 둘째, 전체 조경공사에서 조경관리의 비중은 10여 년간 입찰건수에서 10%, 입찰금액에서 3%의 증가세를 보이는 것으로 나타났다. 셋째, 유형별 입찰추이 분석에서는 녹지가 입찰건수에서 가장 높은 증가세를 보이는 반면, 금액에는 건물녹지가 가장 높은 증가세를 보이는 것으로 나타났다. 넷째, 지자체와 경기도, 조경식재공사업 등이 발주처별, 지역별, 종목별 등의 각 분야에서 가장 높은 입찰건수와 금액의 증가세를 보이고 있는 것으로 나타났다. 이상의 결과를 종합해 보면 조경관리 민간위탁용역의 입찰건수와 금액은 해마다 증가하는 추세이며, 조경공간의 이용자 증가와 이에 따른 다양한 요구, 발주처의 예산문제 등의 복합적인 문제점들을 고려해 볼 때 조경관리 민간위탁용역은 계속해서 증가할 것으로 전망된다. 본 연구는 점차적으로 조경관리의 중요성이 부각되고 있는 현 상황에서 조경관리 민간위탁용역의 10여 년간의 입찰추이를 여러 분야별로 조사 및 분석하고, 체계적으로 정리함으로써 추후 조경관리 민간위탁용역의 기초자료로 활용하고, 조경관리업의 필요성을 인식시켜 향후 전문공사업에 조경관리업이 포함되는 밑바탕을 제공하며, 나아가 조경분야의 전문성 및 다양성을 넓히는 계기를 마련하는데 연구의 의의가 있지만, 조경관리의 법적인 근거, 입찰 시 자격 및 장비기준, 단위당 관리비용의 산정, 관리비의 적정성 등은 추후 보완되어야 될 부분이며, 향후 과제로 남겨두고 있다.

우리나라 조경식재공사의 근원직경 측정기준에 대한 조경식재 실무자들의 의식 (A Study on the Consciousness of Landscape Planting Practitioner about the Measurement Criteria of the Root Diameter of Landscape Trees in the Landscape Planting Construction, in Korea)

  • 한용희;민종일;김도균
    • 한국조경학회지
    • /
    • 제49권2호
    • /
    • pp.27-40
    • /
    • 2021
  • 본 연구는 현재 우리나라에 생산·유통·식재되고 있는 조경수목의 근원직경 측정에 따른 실무자들의 분쟁실태와 합리적인 근원직경 측정위치 설정에 대하여 조사·분석하였다. 조경 실무자들 연령에 따른 '근원직경 측정기준 적정성'에 대한 의식 차이는 통계학적으로 분산분석(Analysis of Variance, ANOVA)을 한 결과, 유의수준 p<0.05에서 차이가 있었다. 조경실무자들의 연령에 따라 조경수목의 근원직경 측정에 대하여 적정성에 대한 차이가 있는 것은 나이가 적을수록 현장경험 차이 등 세대간 의식 차이로 생각되었다. 조경수목의 '근원직경 측정의 모호성'에서는 통계학적으로 분산분석(Analysis of Variance, ANOVA) 결과, 유의수준 p<0.05에서 차이가 있는 것은 직위별이었다. '조경수목 측정기준 개선'에서는 통계학적으로 유의수준 p<0.05에서 차이가 있는 것은 직장유형별이었다. 조경수목 측정기준개선에 대하여 직장유형별로 차이가 있는 것은 발주처와 시공사간 수직적 관계로 분쟁이 많기 때문으로 생각되었다. 조경수목 굴취 시 '표토층 제거방지'에서 통계학적으로 유의수준 p<0.00에서 차이가 있는 것은 연령별이었고, 유의수준 p<0.01에서 차이가 있는 것은 직종별이었으며, 유의수준 p<0.05에서 차이가 있는 것은 근무지역별이었다. 조경수목 굴취 시 '표토 제거와 이식 후 활착'에 대한 의식은 유의미한 차이는 없었다. 조경수목 '근원직경 측정기준 모호에 따른 분쟁 발생'은 직장별, 직종별, 직위별, 근무경력별 전체 평균이 3.85점으로 높았고, 공공기관보다는 조경업체가 더 높았으며, 직위가 높고 경력이 많을수록 분쟁 정도가 높았다. 조경수목 '근원직경 측정의 적정 높이에 대한 의식'은 지하부(33.0%)보다는 지상부(66.5%)의 직경측정을 선호하는 것으로 나타났다. 이식을 위한 조경수목 굴취 시 표토 제거는 지하 평균깊이 -2cm~-4cm가 84.0% 정도로 많았으며, 표토 제거 목적은 '규격과 단가를 높이기 위하여'가 전체의 59.7%로 나타났다.

산림보험(山林保險)에 관한 연구(硏究) (A Study on Forest Insurance)

  • 박태식
    • 한국산림과학회지
    • /
    • 제15권1호
    • /
    • pp.1-38
    • /
    • 1972
  • 우리나라는 근래(近來) 고도경제성장(高度經濟成長)으로 인(因)하여 목재수요(木材需要)가 급증(急增)하고 있으나 국내생산재(國內生産材)가 공급율(供給率)은 수요량(需要量)의 20% 정도(程度)에 지나지 않아 많은 외재(外在)를 도입(導入)하고 있으므로 장래(將來)의 목재(木材) 수요공급(需要供給)의 균형(均衡)을 이룩하기 위하여 강력(强力)한 산림자원(山林資源) 조성사업(造成事業)의 추진(推進)이 요망(要望)된다. 산림자원(山林資源) 조성사업(造成事業)을 추진(推進)하는데 있어서 가장 중요(重要)한 것은 조림의욕(造林意慾)을 높이고 조림사업(造林事業)에 필요(必要)한 산업자본(産業資本)을 산림(山林)에 유치(誘致)하도록 하는 일인데, 이러한 역할(役割)을 할 수 있는 경제적시설(經濟的施設)의 하나가 산림보험제도(山林保險制度)의 실시(實施)인 것이다. 산림보험(山林保險)을 실시(實施)하면 산림재해(山林災害)가 보상(補償)되므로 자본가(資本家)는 안심(安心)하고 조림투자(造林投資)를 할 수 있을 뿐만 아니라 산림(山林)을 담보(擔保)로 한 금융(金融)의 길도 열리어 투자(投資)한 산림(山林)에 환금성(換金性)이 주어지므로 산업자본가(産業資本家)가 산림투자(山林投資)를 회피(回避)하지 않게 되어 산림자원(山林資源) 조성사업(造成事業)이 촉진(促進)될 수 있다. 이러한 관점(觀點)에서 외국(外國)에서는 19세기말(世紀末)부터 산림보험제도(山林保險制度)가 실시(實施)되기 시작(始作)하여 주요(主要) 임업선진국(林業先進國)에서는 모두 산림보험(山林保險)을 실시(實施)하고 있는 것이다. 산림보험(山林保險)을 실시(實施)하는데 있어서 가장 중요(重要)한 것은 장기간(長期間)에 걸친 산림재해(山林災害)의 통계자료(統計資料)를 정확(正確)히 조사(調査)하는 일과 그 나라의 여건(與件)에 맞는 산림보험제도(山林保險制度)를 창설(創設)하는 일이다. 과거(過去) 10년간(年間)(1961~1970)의 년평균(年平均) 산림재해상황(山林災害狀況)을 조사(調査)한 결과(結果)는 산림화재(山林火災)가 9,000여정보(餘町步), 곤충피해(昆蟲被害)가 570,000정보(町步), 병균피해(病菌被害)가 694정보(町步)로 나타났다. 특(特)히 그중 외국(外國)의 산림보험(山林保險)에서 재해보상(災害補償) 대상(對象)의 으뜸이 되고 있는 산림화재(山林火災) 피해상황(被害狀況)을 과거(過去) 18년간(年間)(1953~1970)에 걸쳐서 조사(調査)한 결과(結果)에 의하면 산화면적(山火面積) 위험율(危險率)이 $\frac{1.1853}{1,000}$였고 1960~1969년(年) 사이의 전국(全國) 산림화재면적(山林火災面積) 위험율(危險率)은 $\frac{1.3045}{1,000}$로서 유우럽에 비(比)하여 높았으나 일본(日本)에 비(比)하여 그리 높지 않았다. 또 과거(過去) 5년간(年間)(1966~1970)의 전국(全國)의 산화재적(山火材積) 위험율(危險率)은 $\frac{0.1991}{1,000}$로서 대단(大端)히 낮은데 이것은 우리나라 산림(山林)의 축적(蓄積)이 빈약(貧弱)한데서 온 결과(結果)였다. 이러한 산림재해상황(山林災害狀況)에 비추어 우리나라에서 산림보험(山林保險)을 실시(實施)하려면 어떠한 내용(內容)의 산림보험제도(山林保險制度)를 설립(設立)하는 것이 좋겠는가 하는 질문조사(質問調査)의 결과(結果)는 다음과 같았다. 1. 산림보험(山林保險)의 필요성(必要性) 산림보험(山林保險)은 산림담보(山林擔保)에 의(依)한 금융(金融)의 길을 열어주고(5.65%), 산림피해(山林被害)를 당(當)하였을 때 재조림비(再造林費)를 확보(確保)하게 하여(35.87%), 조림투자(造林投資)를 보증(保證)하는 수단(手段)(46.74%)으로 반드시 실시(實施)되어야 한다고 응답(應答)하였다. 2. 산림보험법(山林保險法) 산림(山林)의 특수성(特殊性)에 비추어 일반(一般) 손해보험(損害保險) 규정(規程)을 준용(準用)할 것이 아니라(8.35%), 산림보험(山林保險)을 위한 특별볍(特別法)을 제정(制定)하여야 한다고 응답(應答)하였다(88.26%). 3. 보험경영업체(保險經營業體)의 종류(種類) 일반(一般) 보험회사(保險會社)(17.42%)나 산림소유자(山林所有者) 상호조합(相互組合)(23.53%)에서 산림보험(山林保險)을 취급(取扱)할 수도 있겠으나, 산림보험(山林保險)의 특이성(特異性)에 비추어 국(國) 공영산림보험(公營山林保險)의 별도(別途)로 운영(運營)되어야 한다고 반응(反應)하였다(56.18%). 4. 보험사고(保險事故)의 종류(種類) 산림보험(山林保險) 사고(事故)를 산화(山火)에 국한(局限)시키거나(23.38%), 산화(山火) 및 기상해(氣象害)만을 포함(包含)시키면 된다는 의견(意見)도 있으나(14.32%), 산림보험(山林保險) 사고(事故)에 산화(山火), 기상해(氣象害), 병충해(病蟲害)까지 포함(包含)시켜야 한다는 의견(意見)이 가장 많았다(60.68%). 5. 보험사고(保險事故) 취급대상(取扱對象)의 종류(種類) 산림보험(山林보험) 취급대상(取扱對象) 수종(樹種)은 침엽수(針葉樹) 인공림(人工林)에 한정(限定)시키거나(13.47%), 침엽수(針葉樹)와 활엽수(濶葉樹)의 인공림(人工林)만을 포함(包含)시키기를 원(願)하는 반응자(反應者)도 있었으나(23.74%), 많은 반응자(反應者)가 수종(樹種), 임종(林種)(인공(人工), 천연(天然)) 구별(區別)없이 모두 포함(包含)시켜야 된다고 반응(反應)하였다(61.64%). 6. 보험사고(保險事故) 취급대상(取扱對象)의 범위(範圍) 산림보험(山林保險) 사고(事故) 취급대상(取扱對象) 범위(範圍)는 10년(年) 이하(以下)의 유령림(幼齡林)만 취급(取扱)하기를 원(願)하는 자(者)(15.23%), 20년(年) 이하(以下)의 임목(林木)만을 대상(對象)으로 하면 족(足)하다는 반응자(反應者)가 있었으나(32.95%), 많은 반응자(反應者)가 40년생(年生) 이하(以下)의 임목(林木)까지 포함(包含)하기를 바라고 있었다(46.37%). 7. 보험계약(保險契約) 기간(期間) 산림보험(山林保險) 계약기간(契約期間)은 1년(年) 단위(單位)가 좋다는 자(者)도 상당(相當)히 있었으나(31.74%), 과반수(過半數)가 5년(年) 단위(單位)로 계약(契約)하는 것을 바라고 있었다(58.68%). 8. 보험계약(保險契約)의 제한(制限) 5정보(町步) 미만(未滿)의 소면적(小面積)은 산림보험(山林保險) 대상(對象)에서 제외(除外)하고(20.78%), 단위(單位) 면적당(面積當) 일정(一定) 재적(材積) 또는 주수(株數)를 보유(保有)하고 있는 산림(山林)만을 계약대상(契約對象)으로 하는 것이 좋다고 반응(反應)하였다(63.77%). 9. 계약방법(契約方法) 산림보험(山林保險) 계약방법(契約方法)은 임의(任意)로 산림(山林)을 선택(選擇)하여 계약(契約)하기를 원(願)하는 자(者)(32.13%), 임의(任意)로 계약(契約)하되 소유산림(所有山林) 전체(全體)를 일괄(一括) 계약(契約)하도록 하는 방법(方法)을 택(擇)하여야 한다는 자(者)(33.48%), 특정임지(特定林地)(신식지(新植地), 보조조림지(補助造林地), 고가임지(高價林地))는 의무적(義務的)으로 계약(契約)하도록 하여야 한다는 반응자(反應者)(31.92%)로 나타나 비슷한 반응(反應)을 보였다. 10. 보험료율(保險料率) 산림보험(山林保險) 요율(料率)은 지역(地域)에 따르는 위험정도(危險程度)를 참작(參酌)하여 면적비례(面積比例)로 결정(決定)하여야 한다는 의견(意見)(31.59%)과 지역(地域) 위험율(危險率)을 참작(參酌)하여 보험가액(保險價額)에 따라 정(定)해야 한다는 의견(意見)이 있었으나(31.59%), 우리 나라에는 지역적(地域的) 위험율(危險率)에 큰 차이(差異)가 없을 것이므로 전국(全國) 일률적(一律的)인 보험료(保險料)를 보험가액(保險價額)에 따라 정(定)하기를 원(願)하는 경향(傾向)이 높았다(39.55%). 11. 보험료(保險料)의 납부(納付) 산림보험료(山林保險料)는 단기(短期)는 일시불(一時拂), 장기(長期)는 매년(每年) 납부(納付)하게 하는 의견(意見)도 있으나(13.80%), 단기(短期)는 고율(高率), 장기(長期)는 저율(低率)로 하되 단기(短期), 장기(長期)를 막론(莫論)하고 매년(每年) 납부(納付)하도록 하여야 한다고 반응(反應)하였다(86.71%). 12. 보험사무(保險事務) 취급기관(取扱機關) 산림보험(山林保險) 사무(事務)의 취급(取扱) 즉(即) 창구업무(窓口業務)의 취급(取扱)을 산림행정기관(山林行政機關)에 위탁(委託)하거나(18.75%), 일반(一般) 보험회사(保險會社)에 맡기기보다는(35.76%) 산림조합(山林組合)에 위탁(委託) 취급(取扱)하게 하고 보험료(保險料)의 일정율(一定率)을 환부(還付)해주는 것이 좋다고 반응(反應)하였다(44.22%). 13. 손해보상(損害補償)의 한도(限度) 산림보험(山林保險)의 손해보상(損害補償)은 유령림(幼齡林)이 피해(被害)를 입었을 때에는 재조림비(再造林費)를 한도(限度)로 하여 보상(補償)하는 것을 원칙(原則)으로 하고 성림(成林)의 경우(境遇)에는 손해액(損害額)의 80%정도(程度)를 한도(限度)로 하여 보상(補償)하기 보다는(29.70%) 실손(實損) 현재가액(現在價額)을 보상(補償)하거나(31.07%) 조림비(造林費)의 복리계산(複利計算) 합계액(合計額)을 보상(補償)하는 것을 바라고 있었다(36.99%). 14. 보험기금(保險基金)의 조성(造成) 산림보험(山林保險)의 기금조성(基金造成)은 손해(損害) 보상액(補償額)에서 일정액(一定額)을 공제(控除) 적립(積立)하여 조성(造成)하거나(15.65%), 임야세(林野稅)를 신설(新設)하여 기금(基金)을 확보(確保)하기 보다는(33.79%), 산림보험(山林保險) 무사고(無事故)로 인(因)한 잉여금(剩餘金)에서 일정액(一定額)씩을 적립(積立)하여 산림보험기금(山林保險基金)으로 하자는 의견(意見)에 많은 반응(反應)을 하였다(44.81%). 15. 산화(山火)의 원인(原因) 산림관계직(山林關係職)에 종사(從事)하고 있는 사람들의 과거(過去)의 경험(經驗)에 비추어 본 우리나라 산화(山火)의 주요원인(主要原因)은 실화(失火)(원인불명(原因不明), 32.39%), 담배불(28.89%), 화전(火田)(19.85%)에 의한 것으로 나타났는데 산림통계(山林統計)에 나타나 있는 산화(山火)의 주요원인(主要原因)과 일치(一致)하였다. 16. 산화경방(山火警防) 산림화재(山林火災) 경방조치(警防措置)로서 가장 중요(重要)하고 실효성(實効性)이 있으며 실천(實踐)할 수 있는 삼대대책(三大對策)으로는 (1) 방화선(防火線) 설치(設置)(23.84%), (2) 건조기(乾燥期)의 입산금지(入山禁止)(21.10%), (3) 메스콤에 의한 계몽교육(啓蒙敎育)(18.01%)이라고 반응(反應)하였다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF