• Title/Summary/Keyword: Standard template

Search Result 115, Processing Time 0.032 seconds

Vertical Alignment of Zinc Oxide Micro Rod with Array of 2-Dimensions (2차원 배열구조를 갖는 ZnO 마이크로 막대 구조체의 수직정렬)

  • Lee, Yuk-Kyoo;Jeon, Chan-Wook;Nam, Hyo-Duk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.459-460
    • /
    • 2008
  • Zinc oxide micro rods were fabricated using as chemical bath deposition ok photolithography. Vertically aligned Zinc Oxide rod array as grown by chemical bath deposition method on Zinc Oxide template layer. The ZnO template layer was deposited on glass and the pattering was made by standard photolithography technique. The selective growth of ZnO micro rods were achieved with the masked ZnO template layer substrate. The fabricated ZnO micro rods were found to be single crystalline and have grown along hexagonal c-axis direction of (0002) which is same as the preferred growth orientation of ZnO template layer. The ZnO micro-rod array structure was implemented as a window layer in Cu(InGa)Se2 solar cell and its effect on photovoltaic efficiency was examined.

  • PDF

Where's the Procedural Fluency?: U.S. Fifth Graders' Demonstration of the Standard Multiplication Algorithm

  • Colen, Yong S.;Colen, Jung
    • Research in Mathematical Education
    • /
    • v.24 no.1
    • /
    • pp.1-27
    • /
    • 2021
  • For elementary school children, learning the standard multiplication algorithm with accuracy, clarity, consistency, and efficiency is a daunting task. Nonetheless, what should be our expectation in procedural fluency, for example, in finding the product of 25 and 37 among fifth grade students? Collectively, has the mathematics education community emphasized the value of conceptual understanding to the detriment of procedural fluency? In addition to examining these questions, we survey multiplication algorithms throughout history and in textbooks and reconceptualize the standard multiplication algorithm by using a new tool called the Multiplication Aid Template.

Usefulness of Registration in the Evaluation of Parkinson′s Disease (영상 융합하여 분석한 파킨슨씨병 환자영상의 유용성)

  • 주라형;김재승;문대혁;최보영;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.268-278
    • /
    • 2003
  • Purpose:The aim of this study was to evaluate the striatal binding ratio, the anterior/posterior ratio and reproducibility using a template based registration method using the standard MR template as a replacement for each patients MR image. Materials and Methods:This study analyzed the 123I IPT SPECT images of 30 patients with IPD, who were subdivided into 17 patients (56.6$\pm$10.8 yr, M/F : 8/9.) with mild IPD, and 13 patients (56.4$\pm$11.1 yr, M/F : 8/5) with severe IPD. In addition, 11 normal controls (57.8$\pm$14.4 yr, M/F : 4/7) were also analyzed. The ROIs were positioned manually in the same slice showing the highest striatal activity using the traditional manual method, whereas those were positioned automatically in a mid striatal slice of the SPECT image coregistered to the standard T1 weighted MR template. Results : The specific binding ratio (SBR) obtained using the template based registration method strongly correlated with those using the manual method in all groups : normal controls (r=0.85, P<0.001), mild IPD (r=0.84, P<0.001) and severe IPD (r=0.7, P=0.01). The SBRs obtained using both methods were significantly different among the three groups (P=0.05) and the SBRs obtained by the template based registration method were higher than those by the manual method (P=0.05) in all three groups. The APRs obtained by the template based registration correlated with those using manual method in only mild IPD (r=0.72, P=0.0). The APRs obtained by the template based registration method were significantly different from the normal controls and those with mild or severe IPD (P<0.05), whereas those obtained using the manual method were not significantly different among the three groups (P>0.1). The reproducibility (rmsCV) of the template based registration method was 7.2% (normal controls:5.2%, mild IPD:4.2%, severe IPD:10.8%), whereas the reproducibility of the manual method was 31% (normal controls:19.7%, mild IPD:21.7%, severe IPD:46.2%). Conclusion:These results show that the use of $^{123}$ I-IPT SPECT for assessing IPD is affected by the methods used to position the striatal ROI. The template based registration method using the standard MR template can be useful in diagnosing IPD and assessing the disease severity with a high reproducibility. Therefore, the template based registration method appears to be a good replacement for the manual method.

  • PDF

A Study on Fitness of ERP template Standardization Methodology for Medium and Small-sized Enterprises (중소기업 ERP 템플릿 표준화 방법론의 프로세스 적합성에 관한 연구)

  • 조영빈;송희석;김성희
    • The Journal of Society for e-Business Studies
    • /
    • v.8 no.4
    • /
    • pp.1-16
    • /
    • 2003
  • ERP implementations are known to be unusually difficult, even when compared to other large-scale systems developing in a firm level, because it requires a substantial investment of time, money, and internal resources. Moreover, medium and small-sized enterprises that are increasingly adopting ERP feel much difficult due to the lack of resources. To promote the spread of ERP in medium and small-sized enterprises, "ERP template standardization methodology" led by government has been used for constructing ERP system in Korea. In this study, we present a study to measure fitness between ERP standard templates and business processes of 10 small enterprises in 5 industries. Also, we define a fitness measure suitable for this purpose. We car find that ERP template standardization methodology is partly adequate to establish ERP systems and it is required to add to templates which support the differences of business process.

  • PDF

Automated Detection of Pulmonary Nodules in Chest Radiography Using Template Matching (단순흉부영상의 Template-Matching을 이용한 폐 결절 자동 추출)

  • 류지연;이경일;오명진;장정란;이배호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.335-338
    • /
    • 2002
  • This paper proposes some technical approaches for automatic detection of pulmonary nodules in chest X-ray images. We applied threshold technique for the lung field segmentation and extended the lung field by using morphological methods. A template matching technique was employed for automatic detecting nodules in lung area. Genetic algorithm(GA) was used in template matching(TM) to select a matched image from various reference patterns(simulated typical nodules). We eliminated the false-positive candidates by using histograms and contrasts. We used standard databases published by Japanese Society of Radiological Technology (JSRT) for correct results. Also we employ two-dimensional Gaussian distribution for some reference images because the shadow of lung nodules in radiogram generally shows the distributions. Nodules of about 89% were correctly detected by our scheme. The simulation results show that it is an effective method to indicate lesions on chest radiograms.

  • PDF

A Secure Face Cryptogr aphy for Identity Document Based on Distance Measures

  • Arshad, Nasim;Moon, Kwang-Seok;Kim, Jong-Nam
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.10
    • /
    • pp.1156-1162
    • /
    • 2013
  • Face verification has been widely studied during the past two decades. One of the challenges is the rising concern about the security and privacy of the template database. In this paper, we propose a secure face verification system which generates a unique secure cryptographic key from a face template. The face images are processed to produce face templates or codes to be utilized for the encryption and decryption tasks. The result identity data is encrypted using Advanced Encryption Standard (AES). Distance metric naming hamming distance and Euclidean distance are used for template matching identification process, where template matching is a process used in pattern recognition. The proposed system is tested on the ORL, YALEs, and PKNU face databases, which contain 360, 135, and 54 training images respectively. We employ Principle Component Analysis (PCA) to determine the most discriminating features among face images. The experimental results showed that the proposed distance measure was one the promising best measures with respect to different characteristics of the biometric systems. Using the proposed method we needed to extract fewer images in order to achieve 100% cumulative recognition than using any other tested distance measure.

The Proposal of IEEE 1451.4 for Piezoelectric Actuator of 1 degree of Freedom (1자유도의 압전 엑추에이터를 위한 IEEE 1451.4 TEDS 제안)

  • Kim, Jeong-Do;Kim, Dong-Jin;Hong, Chul-Ho;Jung, Woo-Suk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.10
    • /
    • pp.1018-1024
    • /
    • 2007
  • It is important to define a standard method to store basic sensor information, such as the type and the structure for an piezoelectric actuator and there is no such method defined in the IEEE 1451.4 transducer electronic data sheet (TEDS) so far. The major challenge is to choose a suitable standard template that can be used with actuators for piezoelectric devices. In this paper, we propose a new template TEDS and the structure of interface for IEEE 1451.4 for piezoelectric actuators.

A Rating Recognition System of Broadcast Program using Template Matching (원형 정합 방법을 이용한 방송 프로그램의 등급 인식 시스템)

  • 황선주;조대제
    • The Journal of the Korea Contents Association
    • /
    • v.4 no.1
    • /
    • pp.24-31
    • /
    • 2004
  • This paper embodies the rating recognition system of broadcast program which can automatically acknowledge the broadcast pictures indicating the harmfulness rating, so prevent children from watching TV. This experiment was progressed as the course of extracting featured patterns (standard number patterns) and the proper patterns owned only by the concerned numbers from the numbers of standard font used by broadcasters, and comparing these patterns with input pictures and arranging them. The recognition rate of x-rating was remarkably high as a result of this experiment.

  • PDF

Maximizing Use of Common Parts in Complex System Design through Organizing 3D Design Process (3D 설계 프로세스 정립을 통한 복잡한 시스템 설계에서의 공용부품 사용 극대화)

  • Choi, Y.W.;Park, K.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.3
    • /
    • pp.209-219
    • /
    • 2007
  • Designing a complex system such as an LCD developing system becomes inefficient when many designers are involved and create their own parts even though they can be used repeatedly in other sections. Thus, this paper proposes a new design process that can maximize the number of common parts in complex system design by organizing the 3D design process. The proposed design process consists of 5 stages: analysis of design intention, definition of initial product structure, definition of skeleton model, sharing design intention with all assembles, control of correlation between components. The proposed design process can maximize common parts in design process, which results in shorter lead time, less production cost, and greater economic benefits.