• 제목/요약/키워드: Standard reference material

검색결과 239건 처리시간 0.029초

노년 여성의 팬티 치수적합성에 관한 연구 (The Study on the Fitness Evaluation of Panty for Elderly Women)

  • 이효진;김진
    • 한국의류학회지
    • /
    • 제31권2호
    • /
    • pp.177-188
    • /
    • 2007
  • The purpose of this study was to provide basic materials for the brief patterns and design development for the elderly women to select number 1 to 3 brands according to their brand preference surveying the elderly women with average shapes, and to compare and analyze the exterior fit and functionality. Accordingly, this study proposed basic materials needed for panty pattern suitable for average shapes of the elderly women. The results of the study are as follows: 1 . Looking into the style, they preferred white the best. Regarding the patterns, almost half preferred patterns and rest of them did not. With the panty with patterns, they wanted small and implicit flower patterns. The design they liked was midi, maxi and then mini in order. When looking into the brands, they preferred 'Company B', 'Company SS', 'Company SY', and then market products. The reason why they selected those panty was feeling of fitness, price and then material. 2. To classify the figures of elderly women, we grouped the subjects with strata method using minimal dispersion method. Type 1 is the average, type 2 is for obese women and type 3 is slender women. 3. 3 brands were selected that were produced using CM 40's and elderly women preferred best. When executing wearing test on two elderly women who have average figure according to the body measures in previous study and body measure of Size Korea total exterior evaluation score was Company A, B and C in order.

면역보조제의 작용 및 개발 (A Current Research Insight into Function and Development of Adjuvants)

  • 손은수;손은화;표석능
    • IMMUNE NETWORK
    • /
    • 제4권3호
    • /
    • pp.131-142
    • /
    • 2004
  • In recent years, adjuvants have received much attention because of the development of purified subunit and synthetic vaccines which are poor immunogens and require adjuvants to evoke the immune response. Therefore, immunologic adjuvants have been developed and testing for most of this century. During the last years much progress has been made on development, isolation and chemical synthesis of alternative adjuvants such as derivatives of muramyl dipeptide, monophosphoryl lipid A, liposomes, QS-21, MF-59 and immunostimulating complexes (ISCOMS). Biodegradable polymer microspheres are being evaluated for targeting antigens on mucosal surfaces and for controlled release of vaccines with an aim to reduce the number of doses required for primary immunization. The most common adjuvants for human use today are aluminum hydroxide and aluminum phosphate. Calcium phosphate and oil emulsions have been also used in human vaccination. The biggest issue with the use of adjuvants for human vaccines is the toxicity and adverse side effects of most of the adjuvant formulations. Other problems with the development of adjuvants include restricted adjuvanticity of certain formulations to a few antigens, use of aluminum adjuvants as reference adjuvant preparations under suboptimal conditions, non-availability of reliable animal models, use of non-standard assays and biological differences between animal models and humans leading to the failure of promising formulations to show adjuvanticity in clinical trials. The availability of hundreds of different adjuvants has prompted a need for identifying rational standards for selection of adjuvant formulations based on safety and sound immunological principles for human vaccines. The aim of the present review is to put the recent findings into a broader perspective to facilitate the application of these adjuvants in general and experimental vaccinology.

The Investigation of a Novel Indicator System for Trace Determination and Speciation of Selenium in Natural Water Samples by Kinetic Spectrophotometric Detection

  • Gurkan, Ramazan;Ulusoy, Halil Ibrahim
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권7호
    • /
    • pp.1907-1914
    • /
    • 2010
  • A novel catalytic kinetic method is proposed for the determination of Se(IV), Se(VI) and total inorganic selenium in water based on the catalytic effect of Se(IV) on the reduction of bromate by p-nitrophenylhydrazine at pH 3.0. The generated bromine, $Br_2$ or $Cl_2$ plus $Br_2$ in 0.1 M NaCl (or NaBr) environment efficiently decolorized Calmagite and the reaction was monitored spectrophotometrically at 523 nm as a function of time. In this indicator reaction, bromide acted as an activator for the catalysis of selenium (IV) and a reducing agent for selenium (VI) at pH 3.0, which allowed the determination of total selenium. The fixed time method was adopted for the determination and speciation of inorganic selenium. Under the optimum conditions, the calibration graph are linear in the range 1 - 35 ${\mu}gL^{-1}$ of Se(IV) for the fixed time method at $25^{\circ}C$. The detection limit based on statistical $3S_{blank}$/m-criterion was 0.215 ${\mu}gL^{-1}$ for the fixed time method (7 min). All of the variables that affect the sensitivity at 523 nm were investigated, and the optimum conditions were established. The interference effect of various cations and anions on the Se (IV) determination was also studied. The selectivity of the selenium determination was greatly improved with the use of the strongly cation exchange resin such as Amberlite IR120 plus. The proposed kinetic method was validated statistically and through recovery studies in natural water samples. The RSDs for ten replicate measurements of 5, 15 and 25 ${\mu}gL^{-1}$ of Se(IV) and Se(VI) was changed between 2.1 - 4.85%. Analyses of a certified standard reference material (NIST SRM 1643e) for selenium using the fixed-time method showed that the proposed kinetic method has good accuracy. Se(IV), Se(VI) and total inorganic selenium in environmental water samples have been successfully determined by this method after selective reduction of Se(VI) to Se(IV).

Isotope Measurement of Uranium at Ultratrace Levels Using Multicollector Inductively Coupled Plasma Mass Spectrometry

  • Oh, Seong-Y.;Lee, Seon-A.;Park, Jong-Ho;Lee, Myung-Ho;Song, Kyu-Seok
    • Mass Spectrometry Letters
    • /
    • 제3권2호
    • /
    • pp.54-57
    • /
    • 2012
  • Mass spectrometric analysis was carried out using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for the precise and accurate determination of the isotope ratios of ultratrace levels of uranium dissolved in 3% $HNO_3$. We used the certified reference material (CRM) 112-A at a trace level of 100 pg/mL for the uranium isotopic measurement. Multiple collectors were utilized for the simultaneous measurement of uranium isotopes to reduce the signal uncertainty due to variations in the ion beam intensity over time. Mass bias correction was applied to the measured U isotopes to improve the precision and accuracy. Furthermore, elemental standard solution with certified values of platinum, iridium, gold, and thallium dissolved in 3% $HNO_3$ were analyzed to investigate the formation rates of the polyatomic ions of $Ir^{40}$ $Ar^+$, $Pt^{40}$ $Ar^+$, $Tl^{40}$ $Ar^+$, $Au^{40}$ $Ar^+$ for the concentration range of 50-400 pg/mL. Those polyatomic ions have mass-to-charge ratios in the 230-245 m/z region that it would contribute to the increase of background intensity of uranium, thorium, plutonium, and americium isotopes. The effect of the polyatomic ion interference on uranium isotope measurement has been estimated.

국내외 발암성물질의 관리기준과 정보제공 현황에 관한 연구 (A study on the criteria and supply status of information for managing carcinogens in domestic and foreign)

  • 이권섭;이종한;이혜진
    • 한국산업보건학회지
    • /
    • 제21권1호
    • /
    • pp.40-48
    • /
    • 2011
  • This study was intended to resolve problems caused by different classification criteria and management methods of carcinogenicity, which have made industrial safety & health institutions and business employers difficult to execute projects or to carry out occupational safety and health related works, and have affected how civic groups perceive carcinogens. The content of this study contained the comparison of management and categorization standards for carcinogens between Korea and other countries as well as the current carcinogenicity-related information supply status of each professional institution. Furthermore, this research examined the current state of supplying information on carcinogenicity among major institutional information supply according to the categorization standard for carcinogens by UN GHS, Ministry of Employment and Labor in Korea(KMoEL), and GHS MSDS provided by Korea Occupational Safety & Health Agency(KOSHA). Now, professional agency provide 927 kinds of IARC, 237 kinds of NTP, 351 kinds of ACGIH and 1,006 kinds of EU ECHA information on carcinogenic agents. KMoEL provides carcinogenicity-related information of 58 chemical agents in accordance with the category of carcinogens guided by ACGIH. KOSHA offers 13,232 kinds of GHS MSDS information including 2,484 carcinogenic substances. Therefore, carcinogenicity-related information of chemical substances, which are not available on the existing GHS MSDS DB, should be updated for the future reference.

Measurement of Energy Dependent Neutron Capture Cross Sections of $^{197}Au$ in Energy Region from 0.1 eV to 10 keV using a Lead Slowing-down Spectrometer

  • Yoon, Jung-Ran
    • 한국방사선학회논문지
    • /
    • 제4권4호
    • /
    • pp.29-32
    • /
    • 2010
  • 본 연구는 교토대학 원자로실험소의 46-MeV전자선형가속기에서 발생된 전자선을 Ta표적에 충돌시켜 발생된 중성자를 이용하였다. 발생된 중성자는 납감속측정장치(LSDS:Lead Slowing-down Spectrometer))속에서 감속되었고 중성자비행시간법(TOF:Time-of-Flight)을 이용하여서 중성자에너지를 선별하여 $^{197}Au$의 중성자포획단면적을 중성자에너지 0.1 eV에서 10 keV범위에 걸쳐 측정하였다. 발생된 중성자속을 측정하기 위하여 $BF_3$검출기속의 $^{10}B(n,{\gamma})$반응을 이용하였고 이것을 이용하여 중성자 반응 단면적을 상대적으로 얻었다. TOF방법으로 얻어진 결과는 1 eV에서의 결과(24.5 b)에 규격화되었다. 기존의 실험결과들과 평가결과들인 JENDL/D-99 Dosimetry File과 비교하였다.

관류 강조 자기공명 영상을 이용한 소아 모야모야 환아의 뇌 혈역학 분석 (Cerebral Hemodynamic Analysis in Pediatric Moyamoya Patients using Perfusion Weighted MRI)

  • 장원석;김태곤;이승구;최중언;김동석
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권3호
    • /
    • pp.207-212
    • /
    • 2005
  • Objective: Classically, single photon emission tomography is known to be the reference standard for evaluating the hemodynamic status of patients with moyamoya disease. Recently, T2-weighted perfusion magnetic resonance(MR) imaging has been found to be effective in estimating cerebral hemodynamics in moyamoya disease. We aim to assess the utility of perfusion-weighted MR imaging for evaluating hemodynamic status of moyamoya disease. Methods: The subjects were fourteen moyamoya patients(mean age: 7.21 yrs) who were admitted at our hospital between Sep. 2001 to Sep 2003. Four normal children were used for control group. Perfusion MR imaging was performed before any treatment by using a T2-weighted contrast material-enhanced technique. Relative cerebral blood volume(rCBV) and time to peak enhancement(TTP) maps were calculated. Relative ratios of rCBV and TTP in the anterior cerebral artery(ACA), middle cerebral artery(MCA) and basal ganglia were measured and compared with those of the posterior cerebral artery(PCA) in each cerebral hemispheres. Using this data, we analysed the hemodynamic aspect of pediatric moyamoya disease patients in regarding to the age, Suzuki stage, signal change in FLAIR MR imaging, and hemispheres inducing symptoms. Results: The mean rCBV ratio of ACA, MCA did not differ between normal children and moyamoya patients. However the significant TTP delay was observed at ACA, MCA territories (mean = 2.3071 sec, 1.2089 see, respectively, p < 0.0001). As the Suzuki stage of patients is advanced, rCBV ratio is decreased and TTP differences increased. Conclusion: Perfusion MR can be applied for evaluating preoperative cerebral hemodynamic status of moyamoya patients. Furthermore, perfusion MR imaging can be used for determine which hemisphere should be treated, first.

어류중 비소의 종분화 분석을 위한 초음파 추출법과 마이크로파 추출법의 비교 (A Comparison of Sonication and Microwave-assisted Extraction Method for Speciation of Arsenic in Fish Tissue, DORM-2)

  • 윤철호;박용철;홍종기
    • 분석과학
    • /
    • 제16권2호
    • /
    • pp.134-142
    • /
    • 2003
  • LC-ICP-MS를 이용한 어류중 비소의 종분화 분석을 위해 microwave-assisted extraction과 sonication extraction 방법을 비교하였다. Ultrasonic nebulizer와 cross flow nebulizer를 사용한 비소종들의 검출한계는 유사한 결과를 보였다. 분석된 비소 종들은 arsenobetaine (AsB), arsenite [As(III)], dimethylarsine acid (DMA), monomethylarsonic acid (MMA), arsenate [As(v)] 와 phenylarsonic acid (PAA) 이다. 두 가지 방법은 NRCC (National Research Council of Canada)의 표준물질인 DORM-2를 50% 메탄올로 추출하였다. arsenobetaine의 경우, 두 방법 모두 5% 이하의 상대표준편차와 82% 이상의 추출효율을 보였다. Arsenobetaine은 microwave assisted extraction 방법에서 $14.18{\pm}0.42mg\;kg^{-1}$을 보였고 sonication extraction 방법에서는 $13.54 {\pm}0.84mg\;kg^{-1}$을 보였다. dimethylarsine acid (DMA)의 경우 각각 $0.45{\pm}0.06mg\;kg^{-1}$$0.44{\pm}0.06mg\;kg^{-1}$를 보였다.

Voltammetric Determination of Copper(II) Using Glassy Carbon Electrodes Modified with Nafion-DTPA-Glycerol

  • Park, Chan-Ju;Park, Eun-Heui;Chung, Keun-Ho
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.177-180
    • /
    • 2003
  • A glassy carbon electrode(GCE) modified with nafion-DTPA-glycerol was used for the highly selective and sensitive determination of a trace amount of Cu$\^$2+/. Various experimental parameters, which influenced the response of nafion-DTPA-glycerol modified electrode to Cu$\^$2+/, were optimized. The copper(II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry, A linear range was obtained in the concentration range 1.0${\times}$10$\^$-8/M∼1.0${\times}$10$\^$-6/M Cu(II) with 7 min preconcentration. Further, when an approximate amount of lead(II) is added to the test solution, nafion-DTPA-glycerol modified glassy carbon electrode has a dynamic range of 2 orders magnitude(1.0${\times}$10$\^$-9/M∼1.0${\times}$10$\^$-7/M). The detection limit(3 $\sigma$) was as low as 5.0${\times}$10$\^$-6/M(0.032ppb). The interferences from other metal ions could be reduced by adding KCN into the sample solutions. This method was applied to the determination of coppe,(II) in certified reference material(3.23${\times}$10$\^$-7/M, 21ppb), sea water(9.50${\times}$10/sup-7/M, 60ppb). The result agrees satisfactorily with the value measured by Korea Research Institute of Standard and Science.

  • PDF

Evaluation of the reproducibility of various abutments using a blue light model scanner

  • Kim, Dong-Yeon;Lee, Kyung-Eun;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.328-334
    • /
    • 2018
  • PURPOSE. To evaluate the reproducibility of scan-based abutments using a blue light model scanner. MATERIALS AND METHODS. A wax cast abutment die was fabricated, and a silicone impression was prepared using a silicone material. Nine study dies were constructed using the prepared duplicable silicone, and the first was used as a reference. These dies were classified into three groups and scanned using a blue light model scanner. The first three-dimensional (3D) data set was obtained by scanning eight dies separately in the first group. The second 3D data set was acquired when four dies were placed together in the scanner and scanned twice in the second group. Finally, the third 3D data set was obtained when eight dies were placed together in the scanner and scanned once. These data were then used to define the data value using third-dimension software. All the data were then analyzed using the non-parametric Kruskal-Wallis H test (${\alpha}=.05$) and the post-hoc Mann-Whitney U-test with Bonferroni's correction (${\alpha}=.017$). RESULTS. The means and standard deviations of the eight dies together were larger than those of the four dies together and of the individual die. Moreover, significant differences were observed among the three groups (P<.05). CONCLUSION. With larger numbers of abutments scanned together, the scan becomes more inaccurate and loses reproducibility. Therefore, scans of smaller numbers of abutments are recommended to ensure better results.