• Title/Summary/Keyword: Standard reference data

Search Result 683, Processing Time 0.03 seconds

Near infrared spectroscopy for classification of apples using K-mean neural network algorism

  • Muramatsu, Masahiro;Takefuji, Yoshiyasu;Kawano, Sumio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1131-1131
    • /
    • 2001
  • To develop a nondestructive quality evaluation technique of fruits, a K-mean algorism is applied to near infrared (NIR) spectroscopy of apples. The K-mean algorism is one of neural network partition methods and the goal is to partition the set of objects O into K disjoint clusters, where K is assumed to be known a priori. The algorism introduced by Macqueen draws an initial partition of the objects at random. It then computes the cluster centroids, assigns objects to the closest of them and iterates until a local minimum is obtained. The advantage of using neural network is that the spectra at the wavelengths having absorptions against chemical bonds including C-H and O-H types can be selected directly as input data. In conventional multiple regression approaches, the first wavelength is selected manually around the absorbance wavelengths as showing a high correlation coefficient between the NIR $2^{nd}$ derivative spectrum and Brix value with a single regression. After that, the second and following wavelengths are selected statistically as the calibration equation shows a high correlation. Therefore, the second and following wavelengths are selected not in a NIR spectroscopic way but in a statistical way. In this research, the spectra at the six wavelengths including 900, 904, 914, 990, 1000 and 1016nm are selected as input data for K-mean analysis. 904nm is selected because the wavelength shows the highest correlation coefficients and is regarded as the absorbance wavelength. The others are selected because they show relatively high correlation coefficients and are revealed as the absorbance wavelengths against the chemical structures by B. G. Osborne. The experiment was performed with two phases. In first phase, a reflectance was acquired using fiber optics. The reflectance was calculated by comparing near infrared energy reflected from a Teflon sphere as a standard reference, and the $2^{nd}$ derivative spectra were used for K-mean analysis. Samples are intact 67 apples which are called Fuji and cultivated in Aomori prefecture in Japan. In second phase, the Brix values were measured with a commercially available refractometer in order to estimate the result of K-mean approach. The result shows a partition of the spectral data sets of 67 samples into eight clusters, and the apples are classified into samples having high Brix value and low Brix value. Consequently, the K-mean analysis realized the classification of apples on the basis of the Brix values.

  • PDF

Evaluation Toolkit for K-FPGA Fabric Architectures (K-FPGA 패브릭 구조의 평가 툴킷)

  • Kim, Kyo-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.4
    • /
    • pp.15-25
    • /
    • 2012
  • The research on the FPGA CAD tools in academia has been lacking practicality due to the underlying FPGA fabric architecture which is too simple and inefficient to be applied for commercial FPGAs. Recently, the database of placement positions and routing graphs on commercial FPGA architectures has been built, and provided for enabling the academic development of placement and routing tools. To extend the limit of academic CAD tools even further, we have developed the evaluation toolkit for the K-FPGA architecture which is under development. By providing interface for exchanging data with a commercial FPGA toolkit at every step of mapping, packing, placement and routing in the tool chain, the toolkit enables individual tools to be developed without waiting for the results of the preceding step, and with no dependency on the quality of the results, and compared in detail with commercial tools at any step. Also, the fabric primitive library is developed by extracting the prototype from a reporting file of a commercial FPGA, restructuring it, and modeling the behavior of basic gates. This library can be used as the benchmarking target, and a reference design for new FPGA architectures. Since the architecture is described in a standard HDL which is familiar with hardware designers, and read in the tools rather than hard coded, the tools are "data-driven", and tolerable with the architectural changes due to the design space exploration. The experiments confirm that the developed library is correct, and the functional correctness of applications implemented on the FPGA fabric can be validated by simulation. The placement and routing tools are under development. The completion of the toolkit will enable the development of practical FPGA architectures which, in return, will synergically animate the research on optimization CAD tools.

Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6 (GATE6를 이용한 Varian 21EX Clinac 선형가속기의 6 MV X-선 특성모사)

  • An, Jung-Su;Lee, Chang-Lae;Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.571-575
    • /
    • 2016
  • Monte Carlo simulations are widely used as the most accurate technique for dose calculation in radiation therapy. In this paper, the GATE6(Geant4 Application for Tomographic Emission ver.6) code was employed to calculate the dosimetric performance of the photon beams from a linear accelerator(LINAC). The treatment head of a Varian 21EX Clinac was modeled including the major geometric structures within the beam path such as a target, a primary collimator, a flattening filter, a ion chamber, and jaws. The 6 MV photon spectra were characterized in a standard $10{\times}10cm^2$ field at 100 cm source-to-surface distance(SSD) and subsequent dose estimations were made in a water phantom. The measurements of percentage depth dose and dose profiles were performed with 3D water phantom and the simulated data was compared to measured reference data. The simulated results agreed very well with the measured data. It has been found that the GATE6 code is an effective tool for dose optimization in radiotherapy applications.

Evaluation of LA-ICP-MS Whole Rock Trace Element Analysis Using Fused Glass Bead of Silicate Rocks (규산염 암석의 알칼리 용융 유리원판에 대한 LA-ICP-MS 전암 미량원소 분석법 평가)

  • Kim, Myong Jung;Kim, Taehoon;Park, Kye-Hun;Lee, Ye Ji;Yang, Yun Seok;Moon, Jeongjin
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.141-147
    • /
    • 2015
  • Using laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), we evaluated the reliability of trace element abundance data measured from the silicate rock references of JR-3, JG-3, JGb-1 and JB-1b using glass discs made by alkali fusion. For 28 elements including rare earth elements, relative standard deviations (RSD) are better than 7% in case when the concentrations of the elements in the rock samples are greater than 10 ppm. However, RSD shows somewhat increased values for the concentrations less than 10 ppm, but never exceeds 25%. Compared with previously reported averages of the compiled abundance data, our data display satisfactory results for the most cases with differences less than 10%. We suggest that LA-ICP-MS analysis using fused glass beads is a reliable, precise and time-saving method of trace element analysis for the silicate rocks spanning from mafic to felsic compositions.

Correlation Between Social Distancing Levels and Nighttime Light (NTL) during COVID-19 Pandemic in Seoul, South Korea Based on The Day-Night Band (DNB) Onboard The Suomi National Polar-Orbiting Partnership (S-NPP) Satellite (코로나19 팬데믹 기간의 서울의 사회적 거리두기 단계 변화와 The Suomi National Polar-Orbiting Partnership (S-NPP) 위성 영상을 이용한 Nighttime Light (NTL) 간의 상관관계)

  • Nur, Arip Syaripudin;Lee, Seulki;Ramayanti, Suci;Han, Ju
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1647-1656
    • /
    • 2021
  • In order to reduce the spread of infection due to COVID-19, South Korea has established a four-step social distancing standard and implemented it by changing the steps based on the rate of confirmed cases. The implementation of social distancing brought about a change in the amount of activity of citizens by limiting social contact such as movement and gathering of people. One of the data that can intuitively confirm this is Night Time Light (NTL). NTL is a variable that can measure the size of the national economy measured using lights captured by satellites, and can be used to understand people's social activities during the night. The NTL visible data is obtained via the Visible Infrared Imaging Radiometer Suite (VIIRS) Day-Night Band (DNB) onboard the Suomi National Polar-orbiting Partnership (S-NPP) satellite. 1023 of Suomi data from 1 January 2019 until 26 October 2021 were collected to generate time series of NTL radiance change over Seoul to analyze the correlation with social distancing policy. The results show that implementing the level of social distancing generally decreased the NTL radiance both in spatial disparities and temporal patterns. The higher level of policy, limiting human activities combined with the low number of people who have been vaccinated and the closure of various facilities. Because of social distancing, the differences in human activities affected the nighttime light during the COVID-19 pandemic, especially in Seoul, South Korea. Therefore, this study can be used as a reference for the government in evaluating and improving policies related to efforts reducing the transmission of COVID-19.

A Short-term Longitudinal Study of Depression and Life Satisfaction of the Elderly: Focusing on Living Arrangement (여성 노인의 거주형태에 따른 우울과 삶의 만족도에 대한 단기종단연구)

  • Jeon, Byeong Joo
    • 한국노년학
    • /
    • v.37 no.4
    • /
    • pp.853-870
    • /
    • 2017
  • This study examined the changes of depression and life satisfaction among the elderly living together in group-home and congregate housing. And in this course, it was to verify the practical effects of the recent government and local authority community life of elderly people by comparing them with the groups of elders living alone. The study was divided into Time 1 and Time 2, and 205 person's data were used for the final analysis. PASW Statistics 18.0 was utilized to analysis the data of this study, because it is difficult to explain the results of this analysis, secondary qualitative research has been used to identify additional contextual information. The major results of this study are as follows. First, the depression of the subjects was significantly improved in the case of living in group-home and congregate housing, and it was significantly worse in the group of elders living alone. Second, the life satisfaction of survey subjects was significantly improved when living in congregate housing, group-home was significantly worse, and the group of elders living alone were not statistically significant but slightly worse. Third, mixed research methods were applied to make accurate interpretation of changes of life satisfaction of the elderly living in group-home. Based on the results of this study, it is possible to establish appropriate measures for the elderly to improve early adjustment and quality of life in community life. And the community life of the elderly can contribute to a real social safety net by solving the blind spot of welfare. At the national level, it can be utilized as a standard reference to improve and strengthen existing policies by providing data that can simultaneously examine the performances and problems of various policies related to housing or the welfare of the elderly.

Fundamental research to investigate methods of vocational competency enforcement in field of home economics education - revision of the current NCS based vocational highschool education curriculum and investigation in change of direction in vocational home economics education - (가정과교육에서의 직업역량 강화 방안 탐색을 위한 기초 연구 - NCS 기반 고교 직업교육과정 개정과 가사실업계 직업교육의 변화 방향 탐색 -)

  • Jang, Myung Hee
    • Journal of Korean Home Economics Education Association
    • /
    • v.26 no.4
    • /
    • pp.129-146
    • /
    • 2014
  • This study is a fundamental research in the field of home economics education to enforce vocational competencies. It was carried out in the purpose of examining the recent economical and social environmental changes and its management system related to the vocational training in the field of home economics education. It seeks change in direction in relation to the National Competency Standard(NCS) based on revisions in the educational system. The method of study was mostly through reference and data analysis, professional advisory and public hearing. The main research results are as follows. First, the main environmental change factors in relation to vocational training have been integrated to the changes in; population structure, gender related economic activities, generation composition, communications technology, and innovation of living technique. These change factors are forecasting innovations in related industries, lifestyle changes, demand for manpower and changes in capabilities required for each specific profession. Second, according to the analysis of current home economics education training, vocational home educations high school accounts for 9.4% of the total number of specialized high schools, where 8 standard departments are specialized in and characterized into 137 different department names. Despite differences among departments, overall employment rate of graduates were measured 44.7%, which rates above the entrance rate of 41.9%. These numbers show great change since 2010(overall employment rate 16.9%, entrance rate 75.2%), a meaningful outcome resulting from changes in policy from the previous employment-centered education system. Third, NCS based on high school vocational home economics education system revision and investigations in change of direction in vocational home economics, this study attempts to provide background for revision from the development of NCS. It also provides proposals for restructuring division of current classification and departments of home economics education, and propositions for further future research.

  • PDF

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.

Studies on the analysis of phytin by the Chelatometric method (Chelate 법(法)에 의(依)한 Phytin 분석(分析)에 관(關)한 연구(硏究))

  • Shin, Jai-Doo
    • Applied Biological Chemistry
    • /
    • v.10
    • /
    • pp.1-13
    • /
    • 1968
  • Phytin is a salt(mainly calcium and magnesium) of phytic acid and its purity and molecular formula can be determined by assaying the contents of phosporus, calcium and magnesium in phytin. In order to devise a new method for the quantitative analysis of the three elements in phytin, the chelatometric method was developed as follows: 1) As the pretreatment for phytin analysis, it was ashfied st $550{\sim}600^{\circ}C$ in the presence of concentrated nitric acid. This dry process is more accurate than the wet process. 2) Phosphorus, calcium and megnesium were analyzed by the conventional and the new method described here, for the phytin sample decomposed by the dry process. The ashfied phytin solution in hydrochloric acid was partitioned into cation and anion fractions by means of a ration exchange resin. A portion of the ration fraction was adjusted to pH 7.0, followed by readjustment to pH 10 and titrated with standard EDTA solution using the BT [Eriochrome black T] indicator to obtain the combined value of calcium and magnesium. Another portion of the ration fraction was made to pH 7.0, and a small volume of standard EDTA solution was added to it. pH was adjusted to $12{\sim}13$ with 8 N KOH and it was titrate by a standard EDTA solution in the presence of N-N[2-Hydroxy-1-(2-hydroxy-4-sulfo-1-naphytate)-3-naphthoic acid] diluted powder indicator in order to obtain the calcium content. Magnesium content was calculated from the difference between the two values. From the anion fraction the magnesium ammonium phosphate precipitate was obtained. The precipitate was dissolved in hydrochloric acid, and a standard EDTA solution was added to it. The solution was adjusted to pH 7.0 and then readjusted to pH 10.0 by a buffer solution and titrated with a standard magnesium sulfate solution in the presence of BT indicator to obtain the phosphorus content. The analytical data for phosphorus, calcium and magnesium were 98.9%, 97.1% and 99.1% respectively, in reference to the theoretical values for the formula $C_6H_6O_{24}P_6Mg_4CaNa_2{\cdot}5H_2O$. Statical analysis indicated a good coincidence of the theoretical and experimental values. On the other hand, the observed values for the three elements by the conventional method were 92.4%, 86.8% and 93.8%, respectively, revealing a remarkable difference from the theoretical. 3) When sodium phytate was admixed with starch and subjected to the analysis of phosphorus, calcium and magnesium by the chelatometric method, their recovery was almost 100% 4) In order to confirm the accuracy of this method, phytic acid was reacted with calcium chloride and magnesium chloride in the molar ratio of phytic: calcium chloride: magnesium chloride=1 : 5 : 20 to obtain sodium phytate containing one calcium atom and four magnesium atoms per molecule of sodium phytate. The analytical data for phosporus, calcium and magnesium were coincident with those as determine d by the aforementioned method. The new method employing the dry process, ion exchange resin and chelatometric assay of phosphorus, calcium and magnesium is considered accurate and rapid for the determination of phytin.

  • PDF

Calibration of Hydrographic Survey Multibeam System Using Terrestrial Laser Scanning and TS Surveying (지상 레이저 스캐닝과 TS 측량을 이용한 멀티빔 시스템의 검·보정)

  • Kim, Jin Soo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.3
    • /
    • pp.199-207
    • /
    • 2013
  • In hydrographic survey, data surveyed with multibeam system includes various errors due to multiple factors. These are corrected by a calibration called patch test, and if existing method is used, the test needs to be conducted for about 8 times for precise system calibration. For more prompt and precise multibeam system calibration, the exact offset of a ship was determined using terrestrial laser scanning and TS surveying, which was used as the initial input for the patch test. In the result, the error of closure was 0.001 m or less for TS surveying and backsight error was 0.005 m or less for scanning. All the surveying data based on the same local coordinate was converted into vessel reference coordinate during which R-square for all rotation angles was 0.99 or higher and standard deviation was 0.008 m or less. Finally, in a patch test using calculated offset of sensors and motion sensor offset, the offset of MBES transducer satisfied manual on hydrography only with 1-time calibration. With these results, it is thought that terrestrial laser scanning and TS surveying can fully be utilized for multibeam system calibration.