• Title/Summary/Keyword: Standard liver volume

Search Result 16, Processing Time 0.023 seconds

Preoperative estimation of hemi-liver volume using standard liver volume and portal vein diameter ratio in living donor liver transplantation

  • Sung-Min Kim;Amro Hasan Ageel;Shin Hwang;Dong-Hwan Jung;Tae-Yong Ha;Gi-Won Song;Gil-Chun Park;Chul-Soo Ahn;Deok-Bog Moon
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.26 no.4
    • /
    • pp.308-312
    • /
    • 2022
  • Backgrounds/Aims: Although body surface area (BSA)-based standard liver volume (SLV) formulae have been used for living donor liver transplantation and hepatic resection, hemi-liver volume (HLV) is needed more frequently. HLV can be assessed using right or left portal vein diameter (RPVD or LPVD). The aim of this study was to validate the reliability of using portal vein diameter ratio (PVDR) for assessing HLV in living liver donors. Methods: This study included 92 living liver donors (59 males and 33 females) who underwent surgery between January 2020 and December 2020. Computed tomography (CT) images were used for measurements. Results: Mean age of donors was 35.5 ± 7.2 years. CT volumetry-measured total liver volume (TLV), right HLV, left HLV, and percentage of right HLV in TLV were 1,442.9 ± 314.2 mL, 931.5 ± 206.4 mL, 551.4 ± 126.5 mL, and 64.6% ± 3.6%, respectively. RPVD, LPVD, and main portal vein diameter were 12.2 ± 1.5 mm, 10.0 ± 1.3 mm, and 15.3 ± 1.7 mm, respectively (corresponding square values: 149.9 ± 36.9 mm2, 101.5 ± 25.2 mm2, and 237.2 ± 52.2 mm2, respectively). The sum of RPVD2 and LPVD2 was 251.1 ± 56.9 mm2. BSA-based SLV was 1,279.5 ± 188.7 mL (error rate: 9.1% ± 14.4%). SLV formula- and PVDR-based right HLV was 760.0 ± 130.7 mL (error rate: 16.2% ± 13.3%). Conclusions: Combining BSA-based SLV and PVDR appears to be a simple method to predict right or left HLV in living donors or split liver transplantation.

Influence of middle hepatic vein resection during right or left hepatectomy on post hepatectomy outcomes

  • Anisa Nutu;Michael Wilson;Erin Ross;Kunal Joshi;Robert Sutcliffe;Keith Roberts;Ravi Marudanayagam;Paolo Muiesan;Nikolaos Chatzizacharias;Darius Mirza;John Isaac;Bobby V. M. Dasari
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.26 no.3
    • /
    • pp.257-262
    • /
    • 2022
  • Backgrounds/Aims: Middle hepatic vein (MHV) is usually preserved as a part of the right or left hepatectomy in order preserve the venous outflow of remnant liver. The aim of this study was to evaluate if resection of MHV could influence post-resection outcomes of standard right or left hepatectomy. Methods: Patients who underwent standard right or left hepatectomy between January 2015 and December 2019 were included. Anatomical remnant liver volumes were measured retrospectively using the Hermes workstation (Hermes Medical Solutions AB, Stockholm, Sweden). Uni- and multi-variate analyses were performed to assess the difference in outcomes of those with preservation of MHV and those without preservation. Results: A total of 144 patients were included. Right hepatectomy was performed for 114 (79.2%) and left hepatectomy was performed for 30 (20.8%) patients. MHV was resected for 13 (9.0%) in addition to the standard right or left hepatectomy. Median remnant liver volume was significantly higher in the MHV resected group (p < 0.01). There was no significant difference in serum level of bilirubin, international normalized ratio, alanine aminotransferase, creatinine on postoperative day 1, 3, 5, or 10, ≥ grade IIIa complications (p = 0.44), or 90-day mortality (p = 0.41). On multivariable analysis, resection of the MHV did not influence the incidence of post hepatectomy liver failure (p = 0.52). Conclusions: Resection of the MHV at standard right or left hepatectomy did not have a negative impact on postoperative outcomes of patients with adequate remnant liver volume.

Deep Learning-Based Assessment of Functional Liver Capacity Using Gadoxetic Acid-Enhanced Hepatobiliary Phase MRI

  • Hyo Jung Park;Jee Seok Yoon;Seung Soo Lee;Heung-Il Suk;Bumwoo Park;Yu Sub Sung;Seung Baek Hong;Hwaseong Ryu
    • Korean Journal of Radiology
    • /
    • v.23 no.7
    • /
    • pp.720-731
    • /
    • 2022
  • Objective: We aimed to develop and test a deep learning algorithm (DLA) for fully automated measurement of the volume and signal intensity (SI) of the liver and spleen using gadoxetic acid-enhanced hepatobiliary phase (HBP)-magnetic resonance imaging (MRI) and to evaluate the clinical utility of DLA-assisted assessment of functional liver capacity. Materials and Methods: The DLA was developed using HBP-MRI data from 1014 patients. Using an independent test dataset (110 internal and 90 external MRI data), the segmentation performance of the DLA was measured using the Dice similarity score (DSS), and the agreement between the DLA and the ground truth for the volume and SI measurements was assessed with a Bland-Altman 95% limit of agreement (LOA). In 276 separate patients (male:female, 191:85; mean age ± standard deviation, 40 ± 15 years) who underwent hepatic resection, we evaluated the correlations between various DLA-based MRI indices, including liver volume normalized by body surface area (LVBSA), liver-to-spleen SI ratio (LSSR), MRI parameter-adjusted LSSR (aLSSR), LSSR × LVBSA, and aLSSR × LVBSA, and the indocyanine green retention rate at 15 minutes (ICG-R15), and determined the diagnostic performance of the DLA-based MRI indices to detect ICG-R15 ≥ 20%. Results: In the test dataset, the mean DSS was 0.977 for liver segmentation and 0.946 for spleen segmentation. The Bland-Altman 95% LOAs were 0.08% ± 3.70% for the liver volume, 0.20% ± 7.89% for the spleen volume, -0.02% ± 1.28% for the liver SI, and -0.01% ± 1.70% for the spleen SI. Among DLA-based MRI indices, aLSSR × LVBSA showed the strongest correlation with ICG-R15 (r = -0.54, p < 0.001), with area under receiver operating characteristic curve of 0.932 (95% confidence interval, 0.895-0.959) to diagnose ICG-R15 ≥ 20%. Conclusion: Our DLA can accurately measure the volume and SI of the liver and spleen and may be useful for assessing functional liver capacity using gadoxetic acid-enhanced HBP-MRI.

Liver Splitting Using 2 Points for Liver Graft Volumetry (간 이식편의 체적 예측을 위한 2점 이용 간 분리)

  • Seo, Jeong-Joo;Park, Jong-Won
    • The KIPS Transactions:PartB
    • /
    • v.19B no.2
    • /
    • pp.123-126
    • /
    • 2012
  • This paper proposed a method to separate a liver into left and right liver lobes for simple and exact volumetry of the river graft at abdominal MDCT(Multi-Detector Computed Tomography) image before the living donor liver transplantation. A medical team can evaluate an accurate river graft with minimized interaction between the team and a system using this algorithm for ensuring donor's and recipient's safe. On the image of segmented liver, 2 points(PMHV: a point in Middle Hepatic Vein and PPV: a point at the beginning of right branch of Portal Vein) are selected to separate a liver into left and right liver lobes. Middle hepatic vein is automatically segmented using PMHV, and the cutting line is decided on the basis of segmented Middle Hepatic Vein. A liver is separated on connecting the cutting line and PPV. The volume and ratio of the river graft are estimated. The volume estimated using 2 points are compared with a manual volume that diagnostic radiologist processed and estimated and the weight measured during surgery to support proof of exact volume. The mean ${\pm}$ standard deviation of the differences between the actual weights and the estimated volumes was $162.38cm^3{\pm}124.39$ in the case of manual segmentation and $107.69cm^3{\pm}97.24$ in the case of 2 points method. The correlation coefficient between the actual weight and the manually estimated volume is 0.79, and the correlation coefficient between the actual weight and the volume estimated using 2 points is 0.87. After selection the 2 points, the time involved in separation a liver into left and right river lobe and volumetry of them is measured for confirmation that the algorithm can be used on real time during surgery. The mean ${\pm}$ standard deviation of the process time is $57.28sec{\pm}32.81$ per 1 data set ($149.17pages{\pm}55.92$).

Effectiveness of High-Volume Therapeutic Plasma Exchange for Acute and Acute-on-Chronic Liver Failure in Korean Pediatric Patients

  • Lim, Hyeji;Kang, Yunkoo;Park, Sowon;Koh, Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.6
    • /
    • pp.481-488
    • /
    • 2022
  • Purpose: Liver transplantation (LT) is the only curative treatment for acute liver failure (ALF) and acute-on-chronic liver failure (ACLF). In high-volume therapeutic plasma exchange (HV-TPE), extracorporeal liver support filters accumulate toxins and improve the coagulation factor by replacing them. In this study, we aimed to evaluate the effectiveness of HV-TPE in pediatric patients with ALF and ACLF. Methods: We reviewed the records of children waiting for LT at Severance Hospital who underwent HV-TPE between 2017 and 2021. Aspartate aminotransferase (AST), alanine aminotransferase (ALT), total and direct bilirubin (TB and DB), gamma-glutamyl transferase (GGT), ammonia, and coagulation parameter-international normalized ratio (INR) were all measured before and after HV-TPE to analyze the liver function. The statistical analysis was performed using IBM SPSS Statistics for Windows, version 26.0 (IBM Co., Armonk, NY, USA). Results: Nine patients underwent HV-TPE with standard medical therapy while waiting for LT. One had neonatal hemochromatosis, four had biliary atresia, and the other four had ALF of unknown etiology. Significant decreases in AST, ALT, TB, DB, GGT, and INR were noted after performing HV-TPE (930.38-331.75 IU/L, 282.62-63.00 IU/L, 11.75-5.59 mg/dL, 8.10-3.66 mg/dL, 205.62-51.75 IU/L, and 3.57-1.50, respectively, p<0.05). All patients underwent LT, and two expired due to acute complications. Conclusion: HV-TPE could remove accumulated toxins and improve coagulation. Therefore, we conclude that HV-TPE can be regarded as a representative bridging therapy before LT.

The Effect of Using Two Different Type of Dose Calibrators on In Vivo Standard Uptake Value of FDG PET (FDG 사용 시 Dose Calibrator에 따른 SUV에 미치는 영향)

  • Park, Young-Jae;Bang, Seong-Ae;Lee, Seung-Min;Kim, Sang-Un;Ko, Gil-Man;Lee, Kyung-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.115-121
    • /
    • 2010
  • Purpose: The purpose of this study is to measure F-18 FDG with two different types of dose calibrator measuring radionuclide and radioactivity and investigate the effect of F-18 FDG on SUV (Standard Uptake Value) in human body. Materials and Methods: Two different dose calibrators used in this study are CRC-15 Dual PET (Capintec) and CRC-15R (Capintec). Inject 1 mL, 2 mL, 3 mL of F-18 FDG into three 2 mL syringes, respectively, and measure initial radioactivity from each dose calibrator. Then measure and record radioactivity at 30 minute interval for 270 minutes. According to the initial radioactivity, linearity between decay factor driven from radioactive decay formula and the values measured by dose calibrator have been analyzed by simple linear regression. Fine linear regression line optimizing values measured with CRC-15 through regression analysis on the basis of the volume of which the measured value is close to the most ideal one in CRC-15 Dual PET. Create ROI on lung, liver, and region part of 50 persons who has taken PET/CT test, applying values from linear regression equation, and find SUV. We have also performed paired t-test to examine statistically significant difference in the radioactivity measured with CRC-15 Dual PET, CRC-15R and its SUV. Results: Regression analysis of radioactivity measured with CRC-15 Dual PET and CRC-15R shows results as follows: in the case 1 mL, the r statistic representing correlation was 0.9999 and linear regression equation was y=1.0345x+0.2601; in 2 mL case, r=0.9999, linear regression equation y=1.0226x+0.1669; in 3 mL case, r=0.9999, linear regression equation y=1.0094x+0.1577. Based on the linear regression equation from each volume, t-test results show significant difference in SUV of ROI in lung, liver, region part in all three case. P-values in each case are as follows: in 1 mL case, lung, liver and region (p<0.0001); in 2 mL case, lung (p<0.002), liver and region (p<0.0001); in 3 mL case, lung (p<0.044), liver and region (p<0.0001). Conclusion: Radioactivity measured with CRC-15 Dual PET, CRC-15R, dose calibrator for F-18 FDG test, do not show difference correlation, while these values infer that SUV has significant differences in the aspect of uptake in human body. Therefore, it is necessary to consider the difference of SUV in human body when using these dose calibrator.

  • PDF

Prediction of Decompensation and Death in Advanced Chronic Liver Disease Using Deep Learning Analysis of Gadoxetic Acid-Enhanced MRI

  • Subin Heo;Seung Soo Lee;So Yeon Kim;Young-Suk Lim;Hyo Jung Park;Jee Seok Yoon;Heung-Il Suk;Yu Sub Sung;Bumwoo Park;Ji Sung Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1269-1280
    • /
    • 2022
  • Objective: This study aimed to evaluate the usefulness of quantitative indices obtained from deep learning analysis of gadoxetic acid-enhanced hepatobiliary phase (HBP) MRI and their longitudinal changes in predicting decompensation and death in patients with advanced chronic liver disease (ACLD). Materials and Methods: We included patients who underwent baseline and 1-year follow-up MRI from a prospective cohort that underwent gadoxetic acid-enhanced MRI for hepatocellular carcinoma surveillance between November 2011 and August 2012 at a tertiary medical center. Baseline liver condition was categorized as non-ACLD, compensated ACLD, and decompensated ACLD. The liver-to-spleen signal intensity ratio (LS-SIR) and liver-to-spleen volume ratio (LS-VR) were automatically measured on the HBP images using a deep learning algorithm, and their percentage changes at the 1-year follow-up (ΔLS-SIR and ΔLS-VR) were calculated. The associations of the MRI indices with hepatic decompensation and a composite endpoint of liver-related death or transplantation were evaluated using a competing risk analysis with multivariable Fine and Gray regression models, including baseline parameters alone and both baseline and follow-up parameters. Results: Our study included 280 patients (153 male; mean age ± standard deviation, 57 ± 7.95 years) with non-ACLD, compensated ACLD, and decompensated ACLD in 32, 186, and 62 patients, respectively. Patients were followed for 11-117 months (median, 104 months). In patients with compensated ACLD, baseline LS-SIR (sub-distribution hazard ratio [sHR], 0.81; p = 0.034) and LS-VR (sHR, 0.71; p = 0.01) were independently associated with hepatic decompensation. The ΔLS-VR (sHR, 0.54; p = 0.002) was predictive of hepatic decompensation after adjusting for baseline variables. ΔLS-VR was an independent predictor of liver-related death or transplantation in patients with compensated ACLD (sHR, 0.46; p = 0.026) and decompensated ACLD (sHR, 0.61; p = 0.023). Conclusion: MRI indices automatically derived from the deep learning analysis of gadoxetic acid-enhanced HBP MRI can be used as prognostic markers in patients with ACLD.

A Study on Homeostasis in Albino Rats by Feeding on Imbalanced Protein Diet (불균형식이(不均衡食餌)에 의(依)한 백서체내(白鼠體內) Homeostasis에 대(對)한 연구(硏究))

  • Ryu, Tcheong-Kun
    • Journal of Nutrition and Health
    • /
    • v.7 no.2
    • /
    • pp.37-51
    • /
    • 1974
  • This Study was carried out to observe the effect of nutritional condition on the change of protein metabolism in the animal body by feeding on imbalanced protein diet. A total 242 growing male albino rats, weighing $115{\sim}120$ gm, were used for the experimental animals. The rats were fed on the standard diet(st), protein flee diet(pf) and imbalanced protein diet(ib) for twelve weeks respectively. Hemoglobin, packed cell volume in blood, and total nitrogen, amino acid nitrogen, urea-nitrogen, creatinine, transaminases(GPT, GOT) in liver and serum, and total nitrogen in small intestine, and total nitrogen, urea-nitrogen In small intestine, and total nitrogen, urea-nitrogen, creatinine, urea-nitrogen/creatinine ratio in urine were measured. The results obtained are as follows; 1. The gained body weight were lower in pf group and ib group than those of st group. The gained body weight fed for 12 weeks, were 80% lower in pf group than those of st group, and the body weight of pf group for $50{\sim}75$ days feeding were $40{\sim}60%$ decreased, compared with the stating weight, and then all of them died. 2. The change of the brain, liver, kidney, spleen and small intestine by feeding on imbalanced diet for 12 weeks were no remarkable difference with the starting weight, but those of protein free diet group were half or more decrease and those were significantly lower in spleen and small intestine especially than the other organ 3. The contents of hemoglobin in pf group for 8 weeks feeding, and the packed cell volume in pf group for 8 weeks feeding and in ib group for 12 weeks feeding were decreased. but those of the other feeding group were almost same value. 4. The total nitrogen in the liver, small intestine and serum of each diet group were no remarkable difference respectively. The contents of amino acid nitrogen in pf group for 2 and 6 weeks feeding were increased. 5. On transaminases: a) The cycle of increase and decrease of GPT activities were come periodically and the interval of cycle were fast in the early stage of feeding and slow there-after. b) The GPT activities were decreased gradually in pf group after feeding and those were increased in ib group for 6 weeks feeding but decreased there-after. The frequency of cycle were more GPT than GOT and specially those of GPT in early stage of feeding were two or three times while GOT was one. c) The interval of increase and decrease in GOT and amino acid nitrogen cycle were similar tendency. 6. The contents of total nitrogen, creatinine and urea-nitrogen of pf group in urine were decreased very sharply from sharting feeding to one week but increased dully from six weeks to eight weeks feeding. The contents of urea-nitrogen of ib group were increased dully by feeding on ten weeks but decreased by feeding on twelve weeks. From the above results, it is concluded that the trend of the metabolic change is maintained equally by homeostatic mechanism using the endogenous protein source during a certain period by imbalanced protein diet feeding. The homeostatic mechanism is come peridically, very fast in early stage of feeing and than slow there-after.

  • PDF

A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam (다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가)

  • Yeom, Misuk;Yoon, Inha;Hong, Donggi;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • Purpose : Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. Materials and Methods : The treatment plans for five patients, being treated on TrueBeam STx(Varian$^{TM}$, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Results : Average value of CI, HI and PCI for PTV was $1.381{\pm}0.028$, $1.096{\pm}0.016$, $0.944{\pm}0.473$ in VMAT and $1.381{\pm}0.042$, $1.136{\pm}0.042$, $1.534{\pm}0.465$ in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. Conclusion : VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  • PDF

Development of RMRD and Moving Phantom for Radiotherapy in Moving Tumors

  • Lee, S.;Seong, Jin-Sil;Chu, Sung-Sil;Yoon, Won-Sup;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.63-63
    • /
    • 2003
  • Purpose: Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. We developed a simple and handy method, which can reduce PTV margins in patients with moving tumors, respiratory motion reduction device system (RMRDs). Materials and Methods: The patients clinical database was structured for moving tumor patients and patient setup error measurement and immobilization device effects were investigated. The system is composed of the respiratory motion reduction device utilized in prone position and abdominal presser (strip device) utilized in the supine position, moving phantom and the analysis program, which enables the analysis on patients setup reproducibility. It was tested for analyzing the diaphragm movement and CT volume differences from patients with RMRDs, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using a treatment planning software. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the fraction of the normal liver receiving to 50% of the isocenter dose(TD50). Results: In case of utilizing RMRDs, which was personally developed in our hospital, the value was reduced to $5pm1.4 mm$, and in case of which the belt immobilization device was utilized, the value was reduced to 3$pm$0.9 mm. Also in case of which the strip device was utilized, the value was proven to reduce to $4pm.3 mm$0. As a result of analyzing the TD50 is irradiated in DVH according to the radiation treatment planning, the usage of the respiratory motion reduction device can create the reduce of 30% to the maximum. Also by obtaining the digital image, the function of comparison between the standard image, automated external contour subtraction, and etc were utilized to develop patients setup reproducibility analysis program that can evaluate the change in the patients setup. Conclusion: Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF