• Title/Summary/Keyword: Standard evaluation

Search Result 5,518, Processing Time 0.045 seconds

The Prediction of DEA based Efficiency Rating for Venture Business Using Multi-class SVM (다분류 SVM을 이용한 DEA기반 벤처기업 효율성등급 예측모형)

  • Park, Ji-Young;Hong, Tae-Ho
    • Asia pacific journal of information systems
    • /
    • v.19 no.2
    • /
    • pp.139-155
    • /
    • 2009
  • For the last few decades, many studies have tried to explore and unveil venture companies' success factors and unique features in order to identify the sources of such companies' competitive advantages over their rivals. Such venture companies have shown tendency to give high returns for investors generally making the best use of information technology. For this reason, many venture companies are keen on attracting avid investors' attention. Investors generally make their investment decisions by carefully examining the evaluation criteria of the alternatives. To them, credit rating information provided by international rating agencies, such as Standard and Poor's, Moody's and Fitch is crucial source as to such pivotal concerns as companies stability, growth, and risk status. But these types of information are generated only for the companies issuing corporate bonds, not venture companies. Therefore, this study proposes a method for evaluating venture businesses by presenting our recent empirical results using financial data of Korean venture companies listed on KOSDAQ in Korea exchange. In addition, this paper used multi-class SVM for the prediction of DEA-based efficiency rating for venture businesses, which was derived from our proposed method. Our approach sheds light on ways to locate efficient companies generating high level of profits. Above all, in determining effective ways to evaluate a venture firm's efficiency, it is important to understand the major contributing factors of such efficiency. Therefore, this paper is constructed on the basis of following two ideas to classify which companies are more efficient venture companies: i) making DEA based multi-class rating for sample companies and ii) developing multi-class SVM-based efficiency prediction model for classifying all companies. First, the Data Envelopment Analysis(DEA) is a non-parametric multiple input-output efficiency technique that measures the relative efficiency of decision making units(DMUs) using a linear programming based model. It is non-parametric because it requires no assumption on the shape or parameters of the underlying production function. DEA has been already widely applied for evaluating the relative efficiency of DMUs. Recently, a number of DEA based studies have evaluated the efficiency of various types of companies, such as internet companies and venture companies. It has been also applied to corporate credit ratings. In this study we utilized DEA for sorting venture companies by efficiency based ratings. The Support Vector Machine(SVM), on the other hand, is a popular technique for solving data classification problems. In this paper, we employed SVM to classify the efficiency ratings in IT venture companies according to the results of DEA. The SVM method was first developed by Vapnik (1995). As one of many machine learning techniques, SVM is based on a statistical theory. Thus far, the method has shown good performances especially in generalizing capacity in classification tasks, resulting in numerous applications in many areas of business, SVM is basically the algorithm that finds the maximum margin hyperplane, which is the maximum separation between classes. According to this method, support vectors are the closest to the maximum margin hyperplane. If it is impossible to classify, we can use the kernel function. In the case of nonlinear class boundaries, we can transform the inputs into a high-dimensional feature space, This is the original input space and is mapped into a high-dimensional dot-product space. Many studies applied SVM to the prediction of bankruptcy, the forecast a financial time series, and the problem of estimating credit rating, In this study we employed SVM for developing data mining-based efficiency prediction model. We used the Gaussian radial function as a kernel function of SVM. In multi-class SVM, we adopted one-against-one approach between binary classification method and two all-together methods, proposed by Weston and Watkins(1999) and Crammer and Singer(2000), respectively. In this research, we used corporate information of 154 companies listed on KOSDAQ market in Korea exchange. We obtained companies' financial information of 2005 from the KIS(Korea Information Service, Inc.). Using this data, we made multi-class rating with DEA efficiency and built multi-class prediction model based data mining. Among three manners of multi-classification, the hit ratio of the Weston and Watkins method is the best in the test data set. In multi classification problems as efficiency ratings of venture business, it is very useful for investors to know the class with errors, one class difference, when it is difficult to find out the accurate class in the actual market. So we presented accuracy results within 1-class errors, and the Weston and Watkins method showed 85.7% accuracy in our test samples. We conclude that the DEA based multi-class approach in venture business generates more information than the binary classification problem, notwithstanding its efficiency level. We believe this model can help investors in decision making as it provides a reliably tool to evaluate venture companies in the financial domain. For the future research, we perceive the need to enhance such areas as the variable selection process, the parameter selection of kernel function, the generalization, and the sample size of multi-class.

The Contents and Satisfation of Home Care Progral Delivered by Seoul Nurses Association (서울시 간호사회 가정간호시범사업 서비스 내용 및 만족도 분석)

  • Lim, Nan-Young;Kim, Keum-Soon;Kim, Young-lm;Kim, Kwuy-Bun;Kim, Si-Hyun;Park, Ho-Ran
    • The Korean Nurse
    • /
    • v.36 no.1
    • /
    • pp.59-76
    • /
    • 1997
  • The purposes of this study were to identify the contents and satisfaction level of the patients received home care service, and to compare the differences of the contents by the characteristics of the patients. Seventy eight patients received home care service from 1st Jan. to 30th Sept., 1996 were data-collected to analyze the contents and outcomes of home care service. Sixty-nine patients currently receiving home care service were participated to evaluate the satisfaction level of home care service. The data were analyzed using mean, standard deviation, $x^2$ test, and ANOVA by SPSS $PC^+$ program. The findings of this study were as follow : 1. The contents & outcomes of home care service 1) The mean age of the subjects was 64.4 years: 58% of them were female. Those who living in Seoul were 83% and the rest of the subjects was living in Kyung-Gi. 2) The subjects who had one diagnosis were 41%. Over 60% of them had the disease of neurologic & sensory system. 3) The mean number of visit was 6. Only one visit was 22%. The mean time of care was 79 minutes. Duration of visit from 31 minutes to 60 minutes were 47 %. The subjects who terminated the visit because of death were 67.3%. 62% of the persons who referred them to the home care service were nurses. 4) The pain after the service was more relieved than before. The amounts of intake, the degree of bed sore, edema & fracture after the service were more improved than before. Health status after the service was improved in general. 5) There were significant differences between initial and last conscious level in tracheostomy care & oxygen inhalation care. There was significant difference between initial and last degree of activity in blood sugar check. 6) There were significant differences on the number of visit in assessment of the status, evaluation & observation, vital sign check, skin care, injection, medication, bed sore care, colostomy care, relaxation therapy for pain relief, patient education, family care, exercise therapy, position change, supply of disinfected equipments and infection control. There were significant differences on visiting time in nasogastric tube care, drainage tube care and oxygen inhalation care. 2. The satisfaction level of home care service 1) 50% were male. Over 60 years of the subjects was 61 %. Those who living in Seoul were 82%. 2) The subjects who had one or two diagnosis were 32% respectively. 55% of the persons who referred them to the home care service were nurses. 3) Total level of satisfaction of home care service was very high. 4) The older the age, the higher the satisfaction level. The larger the number of visit, the higher the satisfaction level. 5) The subjects who were in cloudy state were higher level of satisfaction than in alert or coma state. The subjects whose activity were normal or who needed assistance were higher level of satisfaction than bedridden or immobilized subjects. These findings suggested that the patients had substantial need for posthospital care. They tended to be elderly and to have experienced the wide range of health problems associated with aging, chronicity, including limitations in activities, and other serious health problems. So, the nationwide home care systems beyond the limit of demonstration program by local association and the development of the effective financial system of home based health care are necessary for the clients who are in need of home care.

  • PDF

A Study for the Evaluation of Container Modules; The Technology of Korean Container Tree Production Model (한국형 컨테이너 조경수 생산기술로서 컨테이너 모듈의 성능 평가)

  • Jung, Yong-Jo;Lim, Byung-Eul;Oh, Jang-keun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.5
    • /
    • pp.59-67
    • /
    • 2016
  • In landscape design by public institutions, although the costs and species of landscape trees stipulated by the Korean Public Procurement Service(PPS) are generally adhered to, the PPS regulations about planting trees with well-developed rootlets are almost entirely neglected. This study aimed to evaluate the performance of buried container modules, which are a new technology and product in landscape production that is able to reduce the defect rate while complying with regulations. To this end, this study measured rootlet density, rootlet development length, rootlet survival rate on excavation, and impairments of tree growth for 3 months after root pruning, and compared these variables for the container modules with those for trees that underwent root pruning in bare ground, and those that were cultivated in a container above ground. The results were as follows: First, the rootlet density was 88% for the trees in container modules, which was very high. Trees that underwent standard root pruning in bare ground had a somewhat lower density of 64%. Meanwhile, the trees that were cultivated in pots above ground died, invalidating measurement. Second, in terms of rootlet development and rootlet survival rate, the trees in container modules showed a mean length of 10.4cm, and 100% survival rate, indicating that there was no rootlet damage caused by excavation. For the trees that only underwent root pruning in bare ground, the mean length was 25.6cm and the rootlet survival rate was only half that of the trees in container modules, at 56%, demonstrating considerable damage. Rootlet development did not occur at all in the trees grown in pots. Third, the trees in container modules and those that underwent root pruning in bare ground did not show any deaths during the root pruning process, or any impairments such as stunted leaf growth. Conversely, the trees grown in pots nearly all died, and severe impairments of tree growth were observed. As shown by the results above, when we evaluated the performance of buried container modules, they showed the most outstanding performance of the three models tested in this study. The container modules prevent defects by stimulating early rooting in environments that with poor conditions for growth, or in trees that are not suited to the summer environment Therefore, it is expected that they would be an optimal means by which to enable compliance with rules such as the regulation presented by the PPS.

Superior Labral Dimension of the Glenohumeral Joint on Direct MR Arthrography (MRA): Relationship with Presence of SLAP (Superior Labrum Anterior to Posterior) Lesion (직접 자기공명 견관절 조영술 상에서 상부 관절순의 크기: 상부 관절순 전후방 파열과의 관계)

  • Im, Tae Seong;Choi, Jung-Ah;Oh, Joo Han
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.193-199
    • /
    • 2014
  • Purpose : To evaluate the relationship between superior labral dimension of the glenohumeral joint on direct MRA and presence of SLAP lesion. Materials and Methods: IRB approval was obtained and informed consent was waived for this retrospective study. Direct MRA studies of the shoulder in 296 patients (300 shoulders) with arthroscopic surgery were analyzed by two radiologists blinded to the arthroscopic results, which were used as gold standard. One of the radiologists reviewed the images twice (session 1 and 2) for the evaluation of intra-observer variability. Transverse and longitudinal dimensions of superior labrum on coronal T1-weighted images were measured as base and height of the inverted triangular-shaped superior labrum and compared between patients with SLAP lesions vs. non-SLAP patients. Presence of meniscoid labrum was noted. Statistical analysis was done using unpaired t-test. Results: Among 279 patients (283 shoulders), 122 patients (43.1%) had SLAP lesions. The mean base/height of superior labrum in SLAP and non-SLAP patients measured on T1-weighted MR image were 8.8 mm / 5.2 mm, 8.5 mm / 4.9 mm for reader 1; 8.2 mm / 4.9 mm, 8.1 mm / 4.5 mm for session 1 of reader 2; 8.0 mm / 4.8 mm, 7.6 mm / 4.3 mm for session 2 of reader 2. In SLAP group, the mean labral height was larger than non-SLAP group with statistically significant difference (p<0.05). Fifteen patients (5.3%) had meniscoid labrum according to operation records. Conclusion: In patients with SLAP lesion, the height of the superior glenoid labrum on oblique coronal image of MRA was slightly larger than non-SLAP patients. A larger height of superior glenoid labrum may be associated with SLAP lesions.

Analytical Methods of Hydroxyl Radical Produced by TiO2 Photo-catalytic Oxidation (TiO2 광촉매 산화 반응에서 생성된 수산기 라디칼 분석 방법)

  • Kim, Seong Hee;Lee, Sang-Woo;Kim, Jeong Jin;Kim, Soon-Oh
    • Journal of the Mineralogical Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.245-253
    • /
    • 2015
  • The performance of $TiO_2$ photo-catalytic oxidation process is significantly dependent on the amount of hydroxyl radicals produced during the process, and it is an essential prerequisite to quantify its production. However, precise and accurate methods for quantification of hydroxyl radicals have not been developed so far. For this reason, this study was initiated to compare existing methods for analysis of hydroxyl radicals produced by $TiO_2$ photo-catalytic oxidation and to propose a new method to overcome the limitation of established methods. To simulate $TiO_2$ photo-catalytic oxidation process, Degussa P25 which has been widely used as a standard $TiO_2$ photo-catalyst was used with the dose of 0.05 g/L. The light source of process was UVC mercury low-pressure lamp (11 W, $2,975mW/cm^2$). The results indicate that both potassium iodide (KI)/UV-vis spectrometer and terephthalic acid (TPA)/fluorescence spectrometer methods could be applied to qualitatively measure hydroxyl radicals via detection of triiodide ion ($I_3{^-}$) and 2-hydroxyterephthalic acid which are produced by reactions of iodine ion ($I^-$) and TPA with hydroxyl radicals, respectively. However, it was possible to quantitatively measure hydroxyl radicals using TPA method coupled with high-performance liquid chromatograph (HPLC). The analytical results using TPA/HPLC method show that hydroxyl radical of 0.013 M was produced after 8 hours operation of photo-catalytic oxidation under specific experimental conditions of this study. The proposed method is expected to contribute to precise the evaluation of the performance of photo-catalytic oxidation process.

The Usefulness of MRCP in the Evaluation of Pancreaticobiliary Diseases in Children (소아에서 담췌관 질환에 대한 자기공명 담췌관조영술의 진단적 유용성)

  • Uhm, Ji Hyun;Lee, Seung Yeon;Chung, Ki Sup
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.11
    • /
    • pp.1381-1388
    • /
    • 2002
  • Purpose : Magnetic resonance cholangiopancreatography(MRCP) is a noninvasive method for imaging the pancreaticobiliary tree. The aim of this study was to evalute the usefulness of MRCP for the diagnosis of pancreaticobiliary diseases in children. Methods : From October 1996 to May 2001, 67 patients with obstructive jaundice and three patients with chronic recurrent pancreatitis were evaluated with abdominal ultrasonography and MRCP. The final diagnosis was based on the operative and pathologic findings with biopsy specimen including clinical and laboratory findings. Results : A total of 70 patients, consisting of 31 males and 39 females, with a mean age of $2.6{\pm}3.3$ years were studied. The final diagnosis was biliary atresia in 25, neonatal cholestasis in 18, choledochal cyst without anomalous pancreatobiliary duct union(APBDU) in nine, choledochal cyst with APBDU in seven, cholestatic hepatitis in five, chronic recurrent pancreatitis in three, sclerosing cholangitis in two, and secondary biliary cirrhosis in one case. The overall diagnostic accuracy of abdominal ultrasonography was 75.7% and that of MRCP was 97.1%. The sensitivity and specificity of MRCP were 100% and 98% for biliary atresia, 87.5% and 100% for choledochal cyst with APBDU, 100% and 100% for choledochal cyst without APBDU, sclerosing cholangitis and chronic recurrent pancreatitis, respectively. Conclusion : MRCP is a fast, non-invasive and reliable method for diagnosing pancreaticobiliary diseases in children and will be the standard diagnostic procedure in the future.

Study on the diagnostic utility of serum levels of insulin-like growth Factor-I and insulin-like growth factor binding protein-3 in growth hormone deficiency (성장호르몬 결핍증 진단에 있어서 혈중 insulin-like growth factor-I 및 insulin-like growth factor binding protein-3 농도의 진단적 유용성에 대한 연구)

  • Ji, Geun Ha;Lee, Jeong Nyeo;Chung, Woo Yeong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.12
    • /
    • pp.1329-1335
    • /
    • 2008
  • Purpose : This study aimed to determine the best cutoff line for insulin-like growth factor (IGF)-I and insulin-like growth factor binding protein (IGFBP)-3 to discriminate between growth hormone deficiency (GHD) patients and the control group. Methods : Two hundred thirty subjects with normal controls (129 boys and 101 girls, aged 7-15 years), 14 patients with complete GHD (12 boys and 2 girls), and 17 patients with partial GHD (9 boys and 8 girls) were studied. IGF-I serum concentrations were measured by radioimmunoassay (RI), and IGFBP-3 concentrations were measured by immunoradiometric assay (IRMA). Results : The receiver operating characteristic (ROC) plot analysis showed that the best IGF-I and IGFBP-3 cutoff line was at -1 standard deviation (SD). By comparing IGF-I serum levels of GHD children within 1 SD of normal control, we determined the sensitivity (S) (87.5-100%) and specificity (Sp) (80-84.6%) according to the age group. For IGFBP-3, we determined the following values: S (58.7-85.7%) and Sp (79.2-85.5%). Eleven of 14 patients with complete GHD (78.5%) and 16 of 17 patients with partial GHD (94.1%) had IGF-I concentrations equal to or below -1 SD of the control group mean. Ten of 12 complete GHD children (83.3%) and 13 of 17 partial GHD children (76.5%) had IGFBP-3 concentrations equal or below -1 SD of the control group mean. Conclusion : We conclude that the measurement of IGF-I and IGFBP-3 concentrations might provide essential supplementary data in the diagnostic evaluation of patients with GHD. Our results support the need to use cutoff lines based on below -1 SD of the control.

Acute Ecotoxicity Evaluation of 3 Emulsifiable Concentrates Containing Garlic Extract, Zanthoxylum Extract, and Lemon Grass Oil Originated from Plant (식물추출물 마늘 추출액, 잔톡실럼 정유, 레몬그라스 정유 함유 유제 3종의 생태독성평가)

  • You, Are-Sun;Hong, Soon-Sung;Jeong, Mihye;Park, Kyung-Hun;Chang, Hee-Seop;Lee, Je Bong;Park, Jae-Yup
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.376-382
    • /
    • 2012
  • Environment-friendly agro-materials are are likely to be preferred to chemical insecticides recently. For this reason, many studies are conducted to develop environment-friendly insecticides containing natural materials. This study was also conducted so as to assess ecotoxicity for Emulsifiable concentrate (EC) containing 30% of garlic extract or two plant essential oils (Zanthoxylum, Lemongrass) expected to prevent from pests and be used for agro-materials. Target species used to assess acute toxicity were invertebrate (Daphina magna), fish (Oryzias latipes), honeybee (Apis mellifera L.) and earthworm (Eisenia fetida). The $EC_{50}$ values for of garlic extract 30% EC, Zanthoxylum oil 30% EC and lemongrass oil 30% EC to Daphina magna were 3.3, 10, and $10mg\;L^{-1}$, respectively. The category of garlic extract 30% EC was moderately toxic, while those of Zanthoxylum oil 30% EC and lemongrass oil 30% EC were slightly toxic according to standard of USEPA. $EC_{50}$ for both of Zanthoxylum oil 30% EC and lemongrass oil 30% EC were more than $10mg\;L^{-1}$ then they were considered as slightly toxicity. In case of acute toxicity test to fish, $LC_{50}$ of garlic extract 30% EC was $3.3mg\;L^{-1}$. Zanthoxylum oil 30% EC and lemongrass oil 30% EC indicated $LC_{50}$ > $10mg\;L^{-1}$. Classification of acute toxicity to all test substances was in Korea criteria. Acute contact and oral toxicity test to Honeybee were conducted. As a result, $LD_{50}$ of all test substances were more than 100 a.i. ${\mu}g\;bee^{-1}$ in the acute contact test while $LD_{50}$ of garlic extract 30% EC was 4.4 a.i. ${\mu}g\;bee^{-1}$ and $LD_{50}$ of Zanthoxylum oil 30% EC and lemongrass oil 30% EC were more than 100 a.i. ${\mu}g\;bee^{-1}$. In case of acute toxicity test to earthworm, $LC_{50}$ of garlic extract 30% EC, Zanthoxylum oil 30% EC and lemongrass oil 30% EC were 267, 592, and $430mg\;kg^{-1}$, respectively. In conclusion, if the safety for earthworm is confirmed, these substances are expected to be use for environment-friendly insecticide materials with low risk against ecosystem and contribute to developing environment-friendly agro-materials.

Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy (Image Guided Radiation Therapy (IGRT) 시 On Board Imager를 이용한 환자 Setup Error 보정평가)

  • Kang, Soo-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.69-81
    • /
    • 2008
  • Purpose: To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Materials and Methods: Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2∼3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. Results: General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head & Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head & Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. Conclusion: The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  • PDF

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF