Development of Electronic Management System for improving the utilization of Engineering Model in Domestic Nuclear Power Plant (국내 원전 엔지니어링운영모델 활용성 향상을 위한 시스템 개발)

  • Lee, Sang-Dae;Kim, Jung-Wun;Kim, Mun-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.5
    • /
    • pp.79-85
    • /
    • 2021
  • A standard engineering model that reflects the current organization system and engineering operation process of domestic nuclear power plants was developed based on the Standard Nuclear Performance Model developed by the American Nuclear Energy Association. The level 0 screen, which is the main screen of the engineering model computer system, consisted of an object tree structure, which provided information that is phased down from a higher structure level to a lower structure level (i.e., level 3). The level 1 screen provided information related to the sub-process of the engineering operation, whereas the Level 2 screen provided information related to each engineering operation activity. In addition, the Level 2 screen provided additional functions, such as linking electronic procedures/guidelines, providing electronic performance forms, and connecting legacy computer systems (such as total equipment reliability monitoring system, configuration management systems, technical information systems, risk monitoring systems, regulatory information, and electronic drawing system). This screen level increased the convenience of user's engineering tasks by implementing them. The computerization of an engineering model that connects the entire engineering tasks of an establishment enables the easy understanding of information related to the engineering process before and after the operation, and builds a foundation for the enhancement of the work efficiency and employee capacity. In addition, KHNP developed an online training module, which operates as an e-learning process, on the overview and utilization of a standard engineering model to expand the understanding of standard engineering models by plant employees and to secure competitiveness.

PSCAD/EMTDC Based Modeling and Simulation Analysis of a Grid-Connected Photovoltaic Generation System (PSCAD/EMTDC를 미용한 계통연계형 태양광발전시스템의 모델링 및 모의 해석)

  • Jeon Jin-Hong;Kim Eung-Sang;Kim Seul-Ki
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.3
    • /
    • pp.107-116
    • /
    • 2005
  • The paper addresses modeling and analysis of a grid-connected photovoltaic generation system (PV system). PSCAD/EMTDC, an industry standard simulation tool for studying the transient behavior of electric power system and apparatus, is used to conduct all aspects of model implementation and to carry out extensive simulation study. This paper is aimed at sharing with the PSCAD/EMTDC user community our user-defined model for PV system applications, which is not yet available as a standard model within PSCAD/EMTDC. An equivalent circuit model of a solar cell has been used for modeling solar array. A series of parameters required for array modeling have been estimated from general specification data of a solar module. A PWM voltage source inverter (VSI) and its current control scheme have been implemented. A maximum power point tracking (MPPT) technique is employed for drawing the maximum available energy from the PV array. Comprehensive simulation results are presented to examine PV array behaviors and PV system control performance in response to irradiation changes. In addition, dynamic responses of PV array and system to network fault conditions are simulated and analysed.

Advanced Channel Estimation Schemes Using CDP based Updated Matrix for IEEE802.11p/WAVE Systems

  • Park, Choeun;Ko, Kyunbyoung
    • International Journal of Contents
    • /
    • v.14 no.1
    • /
    • pp.39-44
    • /
    • 2018
  • Today, cars have developed into intelligent automobiles that combine advanced control equipment and IT technology to provide driving assistance and convenience to users. These vehicles provide infotainment services to the driver, but this does not improve the safety of the driver. Accordingly, V2X communication, which forms a network between a vehicle and a vehicle, between a vehicle and an infrastructure, or between a vehicle and a human, is drawing attention. Therefore, various techniques for improving channel estimation performance without changing the IEEE 802.11p standard have been proposed, but they do not satisfy the packet error rate (PER) performance required by the C-ITS service. In this paper, we analyze existing channel estimation techniques and propose a new channel estimation scheme that achieves better performance than existing techniques. It does this by applying the updated matrix for the data pilot symbol to the construct data pilot (CDP) channel estimation scheme and by further performing the interpolation process in the frequency domain. Finally, through simulations based on the IEEE 802.11p standard, we confirmed the performance of the existing channel estimation schemes and the proposed channel estimation scheme by coded PER.

Automation of Skin Allergy Test using Fuzzy Set (Fuzzy Set을 이용한 피부반응 검사의 자동화 연구)

  • Shim, Chul;Jeong, Byeong-Sun;Lee, Myeong-Ku;Park, Mi-Gnon
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.05
    • /
    • pp.43-46
    • /
    • 1990
  • Modern society is prevailed a lot of allergies. So, the allergy test is very important. There are many kinds of allergy test. A doctor usually uses skin allergy test among many allergy tests. However, little standadization and objectivity of grading-standard has been established in the skin allergy test. A measurement of the reaction area has been a major objective to perform skin allergy test. Recently, a doctor's method is to measure the reaction area after drawing a line that represents the reaction area on the skin. But this method differs slightly from the real reaction area and individual doctor's measurement is different, because the edge of the reaction area is obscure. In this paper, we propose a algorithm which is able to detect vague edges using the fuzzy set. The algorithm that detects the line and curve is proposed first. Here, the maximum value is calculated by comparing the membership function of the line and curve seperately. We also encode the direction of the line and curve by using 8-direction code. Then, we calculate the reaction area by measuring the pixels which are inside the reaction area. And finally the Allergy grade is decided by grading-standard, and we accomplish faster, the 80re accurate and objective allergy grade decision.

  • PDF

(A Study on Improvement for Defense Specifications/Standards System) (국방 표준/규격 체계 개선방안 연구)

  • Park, Jae-Yong;Choi, Seok-Cheol
    • Journal of the military operations research society of Korea
    • /
    • v.35 no.1
    • /
    • pp.105-121
    • /
    • 2009
  • Recently, the level of science and technology in our country has reached the level of the advanced countries. However, the level of standards/specifications was insufficient for support. In this study, after a review of the international atmosphere on defense specifications/standards and an investigation of the domestic present situation, three different perspectives of improvement scheme for the defense specifications/standard system are presented. First, in the defense standard classification system perspective, specifications, standards and handbook were defined based on their characteristic and properties. Second, in the perspective concerning the establishment procedure of defense standards/specifications, the bottom-up approach was suggested. Finally, in the perspective of the 'defense standards/specifications instructions', a reinforced drawing number system and other factors to overcome the current limitations are provided.

An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment (도심(都心) 임대(賃貸)아파트의 에너지 및 상수(上水) 소비(消費) 특성(特性) 분석(分析))

  • Seo, Youn-Kyu;Kim, Joo-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.261-265
    • /
    • 2008
  • To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072m^2$ per year and they used $604.2MJ/m^2$ Typical energy consumption unit on $74.4m^2$ of area and $448.8MJ/m^2$ on $105.8m^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an Typical energy consumption unit standard through this research, apartments should use energy more efficiently.

  • PDF

Application of Standard of Review for Safeguard Measure (세이프가드조치의 적법성 평가를 위한 심사기준의 적용에 관한 연구)

  • Lee, Eun-Sup;Kim, Sun-Ok
    • International Commerce and Information Review
    • /
    • v.9 no.2
    • /
    • pp.307-325
    • /
    • 2007
  • Examining the standards of review adopted by the dispute settlement body of the WTO in its decision on safeguard measures, the Appellate Body offers no coherent guidance or theory as to the legitimation of the safeguard measures adopted by the domestic authorities. It faults the lack of reasoned and adequate explanation in the national authorities' decision to impose safeguard measures, yet its own explanation of the permissible role for safeguard measure could hardly be less instructive. The Appellate Body has consistently emphasized fidelity to text in its decision but that approach can not work properly when the text is fundamentally deficient from the viewpoints that neither Article XIX nor the safeguard Agreement establish a coherent foundation for safeguard measures due to their vague and abstract provision. Without any coherent theory on guidance as to the legitimation of the safeguard measures, it would be absurd to expect WTO members to produce a reasoned and adequate explanation as to how their safeguard measures are in compliance with the WTO roles. In the absence of a thorough renegotiation for the proper operation of the WTO safeguard system, which seems quite unlikely for the foreseeable future, perhaps the unique method out of the current predicament is for the Appellate Body to lead a movement in establishing a sensible common law of safeguards, drawing on extra-textual guidance including the standards of review about their proper role in the WTO safeguard mechanism.

  • PDF

A Study on the Standard of the Optician National Licensing Examination by Job Analysis(II) (안경사 국가시험 문항개발 기준(2000년판)작성 연구(II))

  • Lee, Won Jin;Won, Chan Hee;Mah, Ki Choong;Kang, Sung Soo;Ruck, Do Jin;Park, Hae Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.1-11
    • /
    • 2001
  • In this study, the results were that the duty of optician was analysed with DACUM(Developing A Curriculum Method). Task/Skill Matrix was formed and selected the elements above 2.15 points with the job description. The job specification made out the job description and the preference survey for the optician with the job model. These elements made a draft of drawing up standard of the Optician National Licensing Examination by Job Analysis.

  • PDF

Document Research for the Restoration of Traditional Acupunctural Methods (전통침구기법(傳統鍼灸技法)의 복원을 위한 문헌조사)

  • Oh, Jun Ho;Ahn, sang woo
    • The Journal of Korean Medical History
    • /
    • v.18 no.1
    • /
    • pp.103-126
    • /
    • 2005
  • 1) Objective This research is a process of examining the Traditional Acupunctural Methods left in our documents. The objectives of this paper are explaining the process of researching documents and reporting several points revealed in this process. 2) Process This study was done through the following steps: (1) We located the Acupunctural Methods in the original text database on the web. (2) We sorted them according to criterion. (3) We set up some standard clauses in order to organize the selected information. (4) We re-organized the information following the standards within the categories. (5) As for clauses that were not fully explained in the documents, we tried to restore them through other documents. 3) Results (1) 11 standard clauses were set up in order to organize the Traditional Acupunctural Methods. (2) Traditional Acupunctural Methods were extracted from 22 documents, (3) 24 Traditional Acupunctural Methods were extracted and organized by standards. (4) We learned of similar methods with resembling ways of drawing blood and methods with deep interest in the depth of needle insertion. Also, we were able to gain a clue to the exchange of Acupunctural Methods among the three Asian countries and the possibility of research using the Korean Medicine Database.

  • PDF

Development of IFC Standard for Securing Interoperability of BIM Data for Port Facilities (항만 BIM 데이터의 상호운용성 확보를 위한 IFC 표준 개발)

  • Moon, Hyoun-Seok;Won, Ji-Sun;Shin, Jae-Young
    • Journal of KIBIM
    • /
    • v.10 no.1
    • /
    • pp.9-22
    • /
    • 2020
  • Recently, BIM has been extended to infrastructures such as roads and bridges, and the demand for BIM standard development for ports is increasing internationally. Due to the low level of utilization of classification system and drawing standards compared to other infrastructures, and the closed nature of national security facilities, ports have insufficient level of connection and sharing environment among external systems or users. In addition, since the standardization of data for port facilities is not made, it is still necessary to establish an independent DB for each system and to ensure interoperability of data between these systems since it does not have a shared environment among similar data. Therefore, the purpose of this study is to develop and verify IFC, the international standard for BIM, in order to cope with the BIM environment and to be commonly used in the design, construction, and maintenance of port facilities. To this end, we build a standard schema with port-specific Express Notation according to buildingSMART International's standard development methodology. First, domestic and international reference model standards were analyzed to derive components such as space and facilities of port facilities. Based on this, the components of the port facility were derived through the codification, categorization, and normalization process developed by the research team. This was extended based on the port BIM object classification system developed by the research team. Normalization results were verified by designers and associations. Then, IFC schema construction was based on Express-G data modeling based on IFC 4 * 2 Candidate, which is a bridge candidate standard based on IFC4 (ISO16739), and IFC 4 * 3 Draft, which is developed by buildingSMART International. The final schema was validated using the commercialized validation tool. In addition, in order to verify the structural verification of the port IFC schema, the transformation process was verified by converting the caisson model into a Part21 file. In the future, this result will not only be used as a delivery standard for port BIM products, but will also be applied as a linkage standard between systems and a common data format for port BIM platforms when BIM is used in the maintenance phase. In particular, it is expected to be used as a core standard for data exchange in the port maintenance stage.