• Title/Summary/Keyword: Standard House

Search Result 503, Processing Time 0.026 seconds

Regulation of Common Reception System for Broadcasting Signal (방송 공동수신설비의 설치기준)

  • Her, Young-Tae;Kim, Kwang-Ui;Kwon, Won-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.183-184
    • /
    • 2008
  • From the beginning of a new millennium, the digital broadcasting services had been adopted to cable, satellite and radio broadcasting services as well as the terrestrial TV broadcasting services. The government established the installation standard of digital receiving equipment in 2007, which is needed for taking the new digital broadcasting services without additional facilities in an apartment house. In this paper, I will show the installation standard of digital receiving equipment in an apartment house and give a detailed explanation for the main criteria of it.

  • PDF

A Study on Energy Requirement Variation According to Energy Efficiency Rating Evaluation and Design Variable of Standard Design of Rural Houses (농촌주택표준설계도 에너지효율등급평가 및 설계변수에 따른 에너지소요량 변화에 관한 연구)

  • Park, Mi-Lan;Ryoo, Yeon-Su;Choi, Jeong-Man;Seo, Hye-Won
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.2
    • /
    • pp.9-16
    • /
    • 2017
  • The study analyzed the heat losses and the building energy efficiency grade by the energy simulation using the ENERGY# and ECO2 programs for the three types of Standard design of rural houses. It was calculated the energy efficiency rating by the ECO2 program for the rural housing standard design, and the energy demand and the energy consumption by each factor were compared and analyzed. And it analyzed energy consumption by element of each house by ENERGY # program. As a result, first in the evaluation of the energy efficiency grade of buildings by the ECO2 program, the rating for primary energy requirement for the housing newly built by the standard design of rural house is expected to range from 2 to 4 with 189.3 to $238.7kWh/m^2.a$. Second, the energy loss of each part of standard design of rural housing occurs in the order of ventilation 39%, window 33%, outer wall 14%, roof 9%, bottom 5%, and energy loss through ventilation and window occurs more than 70%. Third, the most beneficial effects on the energy efficiency grade is obtained the lowest grade of all three types by 2 when the lowering of the window and door heat transmission rate and the lowering of the light density, and the heat exchange ventilation device is not installed. Fourth, in the standard design of rural housing, the energy demand is occupied by heating > hot water > lighting order, and the order of the weight is changed in order of heating > lighting > ventilation > hot water. Fifth, building energy efficiency assessment system needs to establish policy for fixing rural housing energy as a practical device to ensure energy performance and quality.

Development of Wearable Device for Monitoring Working Environment in Pig House (양돈장 작업환경 모니터링을 위한 웨어러블 장비개발)

  • Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.71-81
    • /
    • 2020
  • Enclosed pig house are creating an environment with high concentrations of gas and dust. Poor conditions in pig farms reduce pig weight and increase disease and accidents for livestock workers. In the pig house, the high concentration of harmful gas may cause asphyxiation accidents to workers and chronic respiratory disease by long-term exposure. As pig farm workers have been aging and feminized, the damage to the health of the harsh environment is getting serious, and real-time monitoring is needed to prevent the damage. However, most of the measuring devices related to humidity, harmful gas, and fine dust except temperature sensors are exposed to high concentrations of gas and dust inside pig house and are difficult to withstand for a long time. The purpose of this study is to develop an wearable based device to monitor the hazardous environment exposed to workers working in pig farms. Based on the field monitoring and previous researches, the measurement range and basic specifications of the equipment were selected, and wearable based device was designed in terms of utilization, economic efficiency, size and communication performance. Selected H2S and NH3 sensors showed the average error of 5.3% comparing to standard gas concentrations. The measured data can be used to manage the working environment according to the worker's location and to obtain basic data for work safety warning.

The Survey for Ventilation Systems of Weaned Pig House in Korea (국내 이유자돈사 환기시설 실태 조사)

  • Lee, Jun-Yeob;Jeon, Jung-Hwan;Song, Jun-Ik
    • Journal of Animal Environmental Science
    • /
    • v.20 no.1
    • /
    • pp.9-14
    • /
    • 2014
  • This survey was conducted to give the basic information for ventilation systems of weaned pig house to establish the acceptable ventilation system in Korea. A total of 11 farms were surveyed in this study and 1 more farm in each province was regionally selected. The general information, inlet and outlet ventilation system, alley in house, space allowance of weaned pigs and manure management were surveyed. Space allowance of weaned pig in 82% of surveyed farms met the legal standard. Side wall inlet and outlet ventilation system were 82% and 73% of surveyed farms, respectively. Moreover, 73% farms have alley in the pig house to control temperature of inlet air. In this survey, both planar slot and circular duct inlet system and side wall fan outlet system could be a favorable ventilation system in weaned pig house.

An Analysis on Effects of Passive Heating of Low Energy House Using Heat in Greenhouse (온실의 열을 이용한 저에너지하우스의 패시브 난방 효과 분석)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: In Korea, to reduce greenhouse gas emissions, energy performance standard of buildings is being reinforced with goals of Passive House until 2017 and Zero Energy House until 2025 in order to reduce emissions from buildings which constitute a quarter of greenhouse gas emissions. In order to achieve the target of Zero Energy House, it is certainly necessary to develop renewable energy that can replace cooling and heating energy occupying a significant amount of building energy consumption after increasing the energy performance firstly. Method: In this study, effects of heat in greenhouse heated by solar heating on indoor heating were analyzed by constructing a greenhouse in front of the Low Energy Building. Result: As a result, indoor temperature was increased by peak average $27.8^{\circ}C$, peak average $6.8^{\circ}C$ was increased from when heat in greenhouse has not been used for heating and indoor surface temperature was increased by average $5.1^{\circ}C$. It shows it can be possible to use heat in greenhouse for heating, if the heating effects can be same as this experimental result because Energy Saving-Type buildings such as Low Energy House or Passive House keep from 18 to $20^{\circ}C$ in winter. Therefore, even if energy supply is cut off by disasters and other reasons, cooling and heating can be possible for some time.

Heating and Cooling Energy Demand Analysis of Standard Rural House Models (농어촌 주택 표준모델의 냉난방에너지요구량 분석)

  • Lee, Chan-Kyu;Kim, Woo-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3307-3314
    • /
    • 2012
  • The annual energy demand of the standard rural house models was analyzed using the DesignBuilder. Indoor temperature set-point, U-value of outer wall, type of window, and degree of ventilation were selected as simulation parameters. In all the simulation cases, heating energy demand was higher than cooling energy demand regardless of the building size. When the lower U-value of the outer wall was applied to account for the thicker insulation layer, heating energy demand was decreased while cooling energy demand was increased. However, it is better to reduce the area of outer wall which is directly exposed to outdoor air because reducing the U-value of the outer wall is not effective in decreasing heating energy demand. Among the four different window types, the double skin window is most favorable because heating energy demand is the lowest. For a fixed infiltration rate, higher ventilation rate resulted in an increased heating energy demand and had minor impact on cooling energy demand. As long as the indoor air quality is acceptable, lower ventilation rate is favorable to reduce the annual energy demand.

Insulation Saving Effect for Korean Apartment House Using Cross-Laminated Timber (CLT)

  • Pang, Sung-Jun;Lee, Bumjin;Jeong, Gi Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.846-856
    • /
    • 2017
  • The aim of this study was to develop the details of cross-laminated timber (CLT) envelops for satisfying the design standard for energy saving (DSEA) and passive standard in South Korea. When the same thickness of 180 mm concrete or CLT was used and the same materials for other layers were used for the roof, wall, and interlayer floor, the required insulation thickness for the different building envelopes in central, southern, and Jeju island was evaluated. As a result, compared to the concrete envelop, about 43 mm of insulation thickness was reduced for wall and roof with the CLT envelope. When the CLT envelopes were modified to protect the CLT from moisture based on FPInnovations (2011), the insulation thickness was further reduced by 12 mm. When the modified CLT building envelops satisfied with a passive standard are used for 10-story building, the required insulation was decreased by $40.89m^3$ for a floor ($105.27m^2{\times}2.3m$ in height) compared to concrete building. As the number of floors increases, about 3.58 m3 of insulation per floor was additionally saved.

A Study on the Planning Improvement of A Hall for the Aged in Apartment Housing -Focusing on apartments of Joong-dong, Bucheon city- (공동주택 경로당의 계획적 개선 방향에 관한 연구 -부천시 중동 소재 아파트를 중심으로-)

  • Ha, Seung-Beom
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.9 no.3
    • /
    • pp.25-35
    • /
    • 2009
  • This study is planning improvement of welfare facilities about the hall for the aged in apartment housing. An apartment house, famous residential type in Korea, put an important value on its convenience and economical efficiency of furniture arrangement by maximizing floor space index. In this regard, leisure usage of house was not carefully considered for the aged people. To redefine the efficiency of welfare facilities, research mainly deals with analysis of realistic needs for the aged through the spot survey and interview. The main purpose of this study is to enhance the quality of welfare facilities and propose the improved welfare facilities for the aged people. Through the research, conclusions are as followed First, Facility standard and provisions of the law should be revised for considering population growth of the aged people. Second, there are 4 plan types in the hall for the aged. Contrary to our expectation, diversity of program was not found however various program planning is needed for considering its different types of plan. Third, according to regulation, space restriction is based on the number of households. Therefore, room and space standard does not depend on the number of people. From now on, in order to improve quality of welfare facilities of the aged, revision of laws and overall facility standard should be implemented in advance.

  • PDF

A Study on the Evaluation for Energy Characteristic of Absorber Floor Insulation of Apartment House (공동주택 층간단열 완충재의 열에너지 특성의 관한 연구)

  • Choi, Dong-Hyuk;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon;Cho, Woo-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.712-717
    • /
    • 2009
  • Ondol is a tradtional Korea heating system with a long history. The ondol heating system is a default in ordinary houses and high-rise apartment alike. But Intensified Architecture Law insulation standard can't satisfied standard insulation only light weight concrete in ondol. The between light weight concrete and slab apply EPS insulation is construct for generate a method of construction. The standard insulation for floor heating system is responsible but complicate construction thermal transmittance and absorber, deteriorate the cost and decreasing the performance insulation & impact floor sound. In study on the evaluation decrease heating-load of floor construction of the insulation & absorber that improvement floor a Apartment house.

  • PDF

Investigation Research for Apartment House Lighting Equipment Standard Establishment (공동주택조명 설비 기준 설정을 위한 조사 연구)

  • Kim, Dong-Kwan;Lee, Sun-Hyung;Lee, Kyung-Sup;Kim, Jang-Yuol;Chon, Yeon-Soo;Chung, Hun-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.562-564
    • /
    • 2001
  • Current interior lighting design way that is consisting uniformly by designer's experience or simple capacity calculation diversifies according to standard of living elevation and there is problem that do not reflect been individualising resident's change request in lighting plan, design properly. Therefore, because this resident's request, enough judgment data that is worth reflecting dissatisfaction item in design concretely or standard is not saved up in business post, had gotten into bottleneck at lighting design. Diagnose resident's consciousness and feedback degree about interior lighting to existent apartment complex in this research and examined improvement plan. As a result, in the case of illumination, wanted higher brightness and showed reason that is most Affirmativ about order way of lighting fixtures. The reason is because can select registration nine that want by oneself directly. Plan qualitative elevation of house lighting environment making lighting image which is coincided in our real condition, and is thought to reflect various resident's character, fondness in design and solved dissatis faction.

  • PDF