• 제목/요약/키워드: Standard House

검색결과 501건 처리시간 0.027초

표준공동주택의 주요 건설자재 설정을 통한 공동주택 환경부하 비교평가에 관한 연구 (The Environmental Load Comparison Evaluation of The Apartment House for Main Construction Materials of Standard Apartment House)

  • 우지환;신성우
    • KIEAE Journal
    • /
    • 제10권1호
    • /
    • pp.85-90
    • /
    • 2010
  • The study set up the models of a general standard apartment house and a super high-rise standard apartment house, which were based on the 5 floor plans of the assessment reference houses of the "green homes" provided by the government; such main construction materials as to account for more than 80% of the entire amount of $CO_2$ emission in a construction work were selected; a database was built up for evaluating the environmental loads of the main materials according to the house types that were different from each other in area, block type, combination of living units or floor; and using the database, an attempt was made to develop the technology to assess $CO_2$ emission from the production of construction materials used in the stage of construction.

신축 아파트의 TVOC 농도 및 거주자의 새집증후군 반응 (TVOC Concentrations and Residents' Responses on Sick House Syndrome of Newly-Built Apartments)

  • 최윤정;안혜정;강미라;이혜민
    • 한국실내디자인학회논문집
    • /
    • 제15권4호
    • /
    • pp.129-137
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations and personal factors to reduce the Sick House Syndrome for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air Quality Management for multi-use facilities. The Questionnaire surveys of residents' subjective responses on the Sick House Syndrome were carried out in 2nd measurement of each house. Respondents consisted of 20 residents living in the measured houses. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among all measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. There turned out to be no apparent relations between the TVOC concentrations and the residents' individual responses of Sick House Syndrome. The responses were serious in those who stayed in their new houses for a long period or had disease like allergy. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

3대 가족형 집합주거의 실용화를 위한 기초연구(I) -계획기준의 도출과 계획기준을 이용한 3대 가족형 주거와의 비교분석을 중심으로- (Study on development of three generation family type apartment plan -Deduction of standard plan and compare standard plan with three generation family type apartment-)

  • 윤삼석;김진모
    • 한국실내디자인학회논문집
    • /
    • 제16권4호
    • /
    • pp.39-46
    • /
    • 2007
  • The aim of this study was to recognize the need of three generation family house that is traditional house type of Korea. First, the pre-research analysis method was used for this study. And then, there are three type's grouping like those are as follows; 1) Recognition of three generation family house. 2) Type of three generation family house. 3) Plans of three generation family house. The analysis results are as follows; If the conditions are better than now, recognition is positive. Type are living together and next doors type can direct access. Some standart plan is been about room's number, house's area, bath's number and so on. Second, try to compare plan - this plan already has been used building - with standard plan. The compare result are as follows; three generation family houses - be used by whom - do not apply to standard plan. Almost houses have a three room that is less than the standard plan. All houses have a number of two bath that is less than the standard plan too. Condition of consideration is suitable to ages in next door type, but in case of living together type that consider user whom is use the inner room. Separation of entrance distinguish between the living together type and the next doors type. In case of living together type Dining with Kitchen room's number is one, but the next doors type have the number of two.

국내 에너지제로하우스 비교를 통한 요소기술 특성 및 표준 모델 제시에 관한 연구 (Suggestion of the Characteristics of Element Technology and the Standard Model through the Comparison of Domestic Zero-energy Houses)

  • 이충국;이정철;김상수;서승직
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.27-35
    • /
    • 2012
  • Five zero energy house models developed in Korea for the purpose of the energy performance were compared and analyzed in the study. The standard passive house model applying common technology and efficient energy performance elements was proposed. Standard passive house 5 models have been developed commonly aiming at 100% energy saving, applying high-performance and high-efficiency exterior thermal insulation, using 3 low-e coated window system, and targeting average 0.65 ACH to enhance privacy. Energy recovery ventilators and dry and cold radiant heating floor has been partially applied. Eco-design techniques such as the awning device, heat insulating door, using natural light have been used. Solar and geothermal systems as the application of renewable energy technologies have been commonly applied. And fuel cells were applied to a partial model. The standard model based on common technical elements and average performance of each element and obtained from five model analysis has been proposed in the study.

장수명 공동주택 표준모델 개발을 위한 실험주택 건립과 현장적용성 평가 (Constructing Mock-up House and Evaluating Field Application for Development of Standard Long-Life Housing Model)

  • 진주원;장한두;최경렬;박준영
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.167-172
    • /
    • 2008
  • The ultimate objective of this research is to develop the technologies for the construction of 100-year housing as the first task for improving housing environments. The technological development of 100-year housing makes it possible to advance construction technologies and part development, to develop long-life housing with durability and Flexibility responding to customers' needs for future living space. At first, for this purpose, the applications according to the types of the Standard Model of Long-life Housing are proposed to respond to the life-cycle of near-future demographic and social structure, and the construction of the Mock-up House execute based on the location selected during the 2nd year and the basic plan. Then the Standard Model of Long-life Housing are advanced and proposed through evaluating the field applicability of the Mock-Up House.

  • PDF

표준설계도에 의해 건축된 농촌주택의 실태조사를 통한 평면구조에 관한 연구 (A Study on the Space Composition for the Rural House Constructed by Standard Plan by the Investigation of Existing Conditions)

  • 박장혁;이신호
    • 농촌계획
    • /
    • 제3권1호
    • /
    • pp.105-113
    • /
    • 1997
  • The actual situation of the rural house already improved since 1970's by standard plan of rural house was surveyed, to find out residential problems and farmers'intention to the improvement, and to make some space composition. The floor space of a living room and sanitary and bath facilities be required of larger dimensions than present. Facilities of sanitary and bath should be stayed indoors. The using-much-room is necessary to washing · and dressing after farm working. The space composition of rural house be variously developed on the basis of farmers'characteristies.

  • PDF

기초형식 및 지반조건에 따른 하우스파이프기초의 인발저항력 특성 (Characteristics of Uplift Capacity of House Pipe Foundation according to Foundation Types and Soil Conditions)

  • 송창섭;장웅희;최득호;김정철
    • 한국농공학회논문집
    • /
    • 제62권1호
    • /
    • pp.117-126
    • /
    • 2020
  • The area of facility horticulture in Korea is increasing rapidly, the single-span pipe house which uses galvanized steel pipe as the main rafters occupies 78.7% of the facility area. Lightweight structures such as the single-span pipe house are vulnerable to meteorological disasters such as strong winds, economic losses of the state, local governments and farmers are continuing as construction does not meet the design standards. In order to minimize economic losses in the horticultural specialty facilities sector, the Rural Development Administration has been operating the horticultural disaster resilient standard for horticultural specialty facilities since April 2007. The only standard for the pipe connector is the disaster resilient standard, there is no standard for the uplift capacity of the house pipe foundation and the research on it is also insufficient. The purpose of this study is to investigate the characteristics of uplift capacity according to the foundation type, compaction ratio and embedded depth through soil box test. The results of the maximum uplift capacity according to the type, compaction ratio and embedded depth can be used as the basic data for the basic design of the pipe house conforming to the disaster resilient standard. Due to the limitation of soil box test, it may be different from the behavior of pipe house installed on site. In the future, the field test and the actual pipe house should be made and supplemented by comparing this result with the field test values.

주택의 조명과 거주자의 면경착용 실태조사연구 (A Study on the Illumination of Household and Research on the Actual Conditions of Wearing Spectacles in Dwellers)

  • 석호작;남철현
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.54-66
    • /
    • 1991
  • As a result of measuring illumination and making up a question at home visit directly by investigator who trained over twenty days period from October 4 to 24, 1990, in order to render help which illumination problem against house, society against eyes or framing of health instruction potgram by seizing natural lighting actual conditions of house and actual conditions of wearing spectacles and by investigating interrelationship, I can summarize as follows. 1) In property of investigation subject, woman 66.9%, In an age, the twenties was largest of 27.4%, the forties was 20.2%, the fifties was 18.6%, the thirties was 17.4%. In academic career, those of upper secondary school grauates was largest of 28.6%, those who possess university career was 25.9%, those who middle school career was 20.9%, decoding of Korean alphabet was 2%. 2) By a residence area, a big city was 43.3%, farming and fishing villages were 20.3%, the rest was a small town and the administrative office of town, township. In positon of house, the middle area was 43.6%, resident of suburb area was 38.0%. In form of house, a Korean-style house was 40.8%, a western-style house was 34.8%, an apartment house was 11.0%. In the a standard of living, the middle classes 77.2%, the lower classes were 15.3%. In residential house unit of area, from 21 to 30 unit of area was largest of 31.5%, from 10 to 20 unit of area was 19.9%, from 31 to 40 was 18.7%. 3) The wearing spectacles rate of study user was 44.1%. By the area, those who wearing spectacles was more than a half of 50.8% in the resident of big city area. As passing from the farm area to the city, that is being resident of big city was high wearing spectacles rate. In position of house, as being residence in central street showed high wearing spectacles rate. (central street was 51.5%, the middle area was 44.5% and the suburb area was 40.1%.) It seemed similarity difference a variable by position of house from wearing spectacles in standard of 1%. By form of house, wearing spectacles rate those who resident in apartment house was 49.5%, that rate those who resident in a western-style house was high of 49.0%, that rate those who resident in a Korean-style house was the lowest 39.0%. By social position of resident in room, in students case who study showed very high, as university students were very high of 62.3% idn wearing spectacles rate, middle and high school students 'were 50.0%, members of society were 47.6%, workers 20.3%. It seemed similarity difference from academic career in standard of 1%. By an age, the thirties was high of 54.1% in wearing spectacles rate, the twenties was 43.2%, the teenage was the lowest of 11.8%. 4) In illumination of study, over 200Lux was high of 40.1%. but below 99Lux which inappropriate illumination to see the books was 32.4%. Average by area, below 99Lux was 22.7% and over 400Lux was 50.0% in case of wooden floor. As examine by area, below 99Lux was high of 27.0% a case of wooden floor in the big city area, it was not good in illumination passing from the farm area(15.0%) to the city(19.0%). Average illlumination by area of the main living room below 99Lux was high of 37.5%, less than 200Lux was 58.5% of whole. In general, illumination of the main livingroom was inappropriate. By area, the big city was 32.5% below 99Lux, the middle and small city area were 33.8%, town and township area were 45.0%, farming and fishing area were 42.8%. By area, in the big city, illumination of study was 52.5% over 200Lux and 28.9% below 99Lux. In case of the middle and small city, study user of below 99Lux was 38.8% and over 200Lux was 46.9%. In case of the seat of town township, below 99Lux was 34.1% and over 200Lux was 39.7%. In case of farming and fishing area, illumination of study was 33.4% below 99Lux and 48.4% over 200Lux. It tends to high rate of inappropriate illumination. 5) By position of house, in case of wooden floor, less than 100Lux was 24.5% in central street. It was bad illumination than others position of house. In case of the main livingroom, less than 100Lux was 40.4% in the suburb area. It was bad iliumnation than others position of house. In case of study, less than 100Lux was 35.4% in the middle area, it was worse in illumination. In case of the main living room, is seemed similarity difference in standard of 1%. 6) By form of house, in case of wooden floor, illumination of less than 100Lux was 23.8% in a western-style house, it was bad illumination than others form of house. In case of the main livingroom, illumination of less than 100Lux was 47.4% in a Korean-style house, it was remarkably bad illumination than others form of house. In case of study, a Korean-style house was 38.8%, it was very bad illumination than others form of house. In case of the main livingroom and study, it seemed similatrity difference each as P < 0.01 and P < 0.05 in standard of 1%. 7) The wearing spectacles rate of those who use room of illumination over 400Lux was 40.7%, and that of those who use room of illumination less than 100Lux was 28.1%. It seemed similarity differecce in standard of 1%. 8) In period of wearing spectacles, 21.3% of total investigator-highest-was from before five years, 8.6% was from before three years. Among those who use of illumintion less than 99Lux, 34.0% began to wear spectacles from before two years 31.7% was from before five years, 30.3% was from before four years. It seemed similarity difference from period of wearing spectacles by illumination in standard of 1 %. 9) Among cause which sight grow worse, the first was that it was each 33.2% and 27.4% in response rate because watch TV nearly to wearing spectacles person and non-wearing person. The second was that a lot of seeing books was 25.3% in wearing spectacles person and response rate for dark illumination was 7.4% in nonwearing spectacles person. It seemed similarity difference in standard of 1%. (P < 0.01). 10) In experience which take medicine good for eyes, it was 50.1% in wearing spectacles person and 8.5% in non-wearing spectacles person. It seemed similarity difference in standard of 1%(P < 0.01). As we have seen above, inappropriate illumination can be a cause of wearing spectacles. Nevertheless, actually, is realities to indifferent against illumination of house. So it must learn knowledge about health obstacle of illumination through society instruction and school eduction against students as well as general residents. In case that natural lighting is inappropriate structural of house, we must be able to maintain appropriate illumination through artificial illumination. And so eyes which is core of human life have to be protected, related the authorities, related group, and all health medical personnel will organically cooperate with and make efforts.

  • PDF

1990년 이후 농촌주택 표준설계도의 입면과 지붕 변화에 관한 연구 (A Study on the Change to the Elevation and Roof of the Standard Rural-House Design After 1990's)

  • 황용운
    • 한국주거학회논문집
    • /
    • 제21권1호
    • /
    • pp.23-30
    • /
    • 2010
  • The purpose of this study is to analyze the elevations of standard rural house designs after the 1990's. Various types of analysis were carried out on a total of 18 different sizes and 50 types of designs with p'yong sizes ranging from 12 to 44. The objects of analysis are the various elevations & the roof types that were supplied in the standard rural house design according to each year 1995 (8 sizes 20 types), 1997 (8 sizes 8 types), 1998 (l size 8 types), 2000 (2 sizes 4 types), 2001 (2 sizes 4 types), and 2004 (3 sizes 6 types). Results from the analysis demonstrate that (1) The gable roof has been used as the roofing type for standard rural house design since 1990. However the roof types of the standard rural house design includes only a few different types of gable roofs and roof materials(most roof types use asphalt shingle). (2) While most front elevations have been altered from asymmetrical to symmetrical most rear elevations have evolved from symmetrical to asymmetrical proportions since the 1990's (3) While siding materials and red-brick were most commonly used the main outer-wall materials prior to 2000, environmentally-friendly materials have been used as outer-wall materials since 2000. (4) In terms of the analysis of outer-wall objects before 2000 the walls were even, yet after 2000 these outer-walls evolved to become concave-convex walls. In other words, the evolution of the outer-wall has included a variety of wall types.

축사표준설계도의 활용도를 높이기 위한 농가 운영 현황 및 축사표준설계도 인식 조사 (Investigation on the Farm Management and Livestock House Design Standard Perception to Enhance Usage of Livestock House Design Standard)

  • 강솔뫼;이인복;황창규;황수진;정득영;이상연;박세준;최영배;김다인
    • 한국농공학회논문집
    • /
    • 제64권6호
    • /
    • pp.87-99
    • /
    • 2022
  • The meat consumption per person has continuously increased in recent years. However, the labor force in the domestic livestock industry has decreased due to the declining and ageing population. In order to increase productivity, the government have developed and distributed design standard of livestock houses. Presently, report showed that the adaptation rate of the developed livestock house design standard on the real farm was still low. Thus, this paper aimed to find ways to improve the utilization of the design standard through surveys. The survey was conducted on 650 farms across the country. Analysis of the result showed that in the poultry house, the unawareness of farmers to the design standard was found to be the biggest reason for not using the design standards. On the other hand, in the swine house, the previously built swine houses do not fit with the design standard. From these result, the following recommendations were suggested: 1) promotion and education are needed to enhance usage of design standard; 2) since it is impossible to make a design standard considering all the farm sites, it is important to consider the conditions of various farm site prior to enhancement of the design standard; 3) improvement factors such as reinforcing the ventilation design, reflecting animal welfare, preventing livestock diseases, and enhancing ICT devices can also be promoted.