• Title/Summary/Keyword: Standard Fossil Power Plant

Search Result 16, Processing Time 0.019 seconds

A study on the evaluation for material degradation of 0.0Cr-0.5Mo steel by a electrochemical polarization method (전기화학적 분극법에 의한 1.0Cr-0.5Mo강의 경년열화 평가에 관한 연구)

  • Na, Eui-Gyun;Kim, Hoon;Lee, Jong-Gi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.177-189
    • /
    • 1998
  • The contents of this paper include a non-destructive technique for evaluating the degradation of the boiler superheater tube in a fossil power plant through an electrochemical polarization test. Correlation between Ip of polarization parameter and SP-DBTT for the superheater tubes in long-term use was obtained. 1.0Cr-0.5Mo steel was degraded by softening, and the degree of degradation was dependent upon carbides with Cr and Mo elements. Since brittle fracture at low temperature and ductile fracture mode at high temperature were shown, similarity between standard Charpy and small punch tests could be found. In addition, SP-DBTT showing the degree of degradation was higher, as the time-in use of the materials got longer. Electrolyte including picric acid of 1.3 g in distilled water of 100ml at 25.deg. C temperature and sodium tridecylbenzene sulfonate with 1g could be applied to evaluate the degradation of 1.0Cr-0.5Mo steel by means of the electrochemical polarization test. Ip and Ipa values measured through the electrochemical test are the appropriate parameters for representing the degradation of the superheater tube(1.0Cr-0.5Mo steel) for the fossil power plant. It is poassible to evaluate the degradation of materials with different time histories electrochemically, by Ip value only, at field test.

A Study on the Equivalent Dynamic Stiffness of Bearing-pedestal (베어링 대의 등가 동강성에 관한 고찰)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.452-456
    • /
    • 2006
  • The critical speeds and mode shapes are most important to determine the behaviors of rotor in designing rotating machinery. As the capacity and span of turbine-generator increases, the turbine-generator system is composed of many components such as bearings, pedestal, turbine and hood and so on. Also, it is getting flexible and has many critical speeds. Especially, as the characteristics of bearing-pedestal are very complicated, they affect the entire vibration characteristics of turbine-generator system. In this paper, it is observed how to determine the equivalent dynamic stiffness of bearing-pedestal by analytical and experimental method.

A Study on the Equivalent Dynamic Stiffness of Bearing-Pedestal (베어링-페데스탈의 등가 강성에 관한 고찰)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun;Lee, Dae-Seong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.263-266
    • /
    • 2005
  • The critical speeds and mode shapes are most important to determine the behaviors of rotor in designing rotating machinery. As the capacity and the span of turbine-generator increases, the turbine-generator system has many components such as bearings, pedestal, turbine and baseplates etc. and it is getting flexible and has many critical speeds. Especially, the characteristics of bearing-pedestal are very complicated and then they affect the entire vibration characteristics of turbine-generator system. In this paper, it is observed how to determine the equivalent dynamic stiffness of bearing-pedestal by analytic and experimental method.

  • PDF

A Study on the Design of Tidal Current Farm in the Bunamgun-do (부남군도에서의 조류발전단지 설계에 관한 연구)

  • Yang, Chang-Jo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.1
    • /
    • pp.85-92
    • /
    • 2013
  • Many efforts will have to be made on securing the stable supply of the energy due to the worldwide trend of controlling the utilization fossil fuels inducing global climate change. Renewable portfolio standard enforced to power companies over 500 MW capacity from 2012. Tidal current energy is one of the most interesting renewable and clean energy resources that have been less exploited. Especially, Korea has worldwide outstanding tidal current energy resources and it is highly required to develop a tidal current energy conversion system(TECS) in coastal region. So, we examine a tidal in-stream energy using a numerical model and estimate a tidal current potential for commercialization of tidal current power plant in the sea of the Bunamgun-do. Available tidal energy resources is also analytically estimated using a tidal farm method and the annual energy production of an optimal TECS arrays will be calculated with taking into account interference of lateral and longitudinal spacing.

The Evaluation of Fretting Fatigue Behavior on Rotary Bending Fatigue for Railway Axle Material (회전굽힘 피로 하에서의 철도 차축재료 프레팅 피로거동 평가)

  • Choi, Sung-Jong;Kwon, Jong-Wan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.2
    • /
    • pp.74-82
    • /
    • 2010
  • Fretting damage can be observed in automobile and railway vehicle, fossil and nuclear power plant, aircraft etc. In the present study, railway axle material RSA1 used for evaluation of fretting fatigue life. Plain and fretting fatigue tests were carried out using rotary bending fatigue tester with proving ring and bridge type contact pad. Through these test, the following results are obtained: 1) it is found that the fretting fatigue limit of standard specimen decreased about 37% compared to the plain fatigue limit. 2) The early crack of Shinkansen type specimens initiated in contact area and final fractured below samp=214 MPa. 3) The early crack of all TGV type specimens initiated in rounded area and fractured. 4) Tire tracks and rubbed scars were observed in the oblique crack region and fatigue crack growth region of fracture surface. 5) The wear debris is observed on the contact surface, and oblique cracks at an earlier stage are initiated in contact area. These results can be used as useful data in a structural integrity evaluation of railway axle.

Thermal Stress Evaluation by Elastic-Creep Analysis during Start-up of Boiler Header (보일러 헤더 기동시의 탄성 크리프 해석에 의한 열응력 평가)

  • Shin, Kyu-In;Yoon, Kee-Bong
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.17-22
    • /
    • 2009
  • Thermal stress and elastic creeping stress analysis was conducted by finite element method to simulate start-up process of a boiler header of 500MW standard fossil power plant. Start-up temperature and operating pressure history were simplified from the real field data and they were used for the thermal stress analysis. Two kinds of thermal stress analysis were considered. In the first case only temperature increase was considered and in the second case both of temperature and operating pressure histories were considered. In the first analysis peak stress was occurred during the temperature increase from the room temperature. Hence cracking or fracture may occur at the temperature far below the operating maximum temperature. In the results of the second analysis von Mises stress appeared to be higher after the second temperature increase. This is due to internal pressure increase not due to the thermal stress. When the stress components of radial(r), hoop($\theta$) and longitudinal(z) stress were investigated, compression hoop stress was occurred at inner surface of the stub tube when the temperature increased from room temperature to elevated temperature. Then it was changed to tension hoop stress and increased because of the operating pressure. It was expected that frequent start-up and shut-down operations could cause thermal fatigue damage and cracking at the stub tube hole in the header. Elastic-creeping analysis was also carried out to investigate the stress relaxation due to creep and stabilized stress after considerable elapsed time. The results could be used for assessing the creep damage and the residual life of the boiler header during the long-tenn service.