• 제목/요약/키워드: Standard Effective Temperature

검색결과 234건 처리시간 0.03초

여름철 사무실내 한국인의 온열감 평가 (Evaluation of Korean Thermal Sensation in Office Buildings During the Summer Season)

  • 배귀남;이철희;이춘식
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.341-352
    • /
    • 1995
  • In this study, thermal parameters were measured and 213 occupants were also questioned in three office buildings located in Seoul during the summer season. Predicted mean vote-predicted percentage of dissatisfied(PMV-PPD) and standard new effective temperature(SET*) were used for evaluating Korean thermal sensation. The distribution of thermal sensation vote(TSV) and percentage of dissatisfied(PD) is very similar to that of PMV and PPD. By regression analysis, the following regression equation was obtained; TSV=0.339SET*-8.583. In this case, neutral temperature and comfort range are $25.3^{\circ}C$, $23.8{\sim}26.8^{\circ}C$ respectively. Present experimental results obtained from the field study is less sensitive to the temperature change than those obtained from the climate chamber study in Korea. But, thermal sensations are similar to each other near the neutral point. The neutral temperature and comfort range obtained by this experiment are higher than those of ANSI/ASHRAE Standard 55-1974 about $1.4{\sim}1.8^{\circ}C$.

  • PDF

동계 인공환경실험에 의한 온열쾌적특성 연구 (A study on characteristics of thermal comfort for artificial environmental experiment in winter)

  • 박종일;김경훈;정성일
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.721-731
    • /
    • 1998
  • Recently, many researchers are studying the relation between thermal environment and human comfort. The purpose of this study was to obtain basic data which are necessary to determine the thermal comfort sensation and physiological responses for men in winter indoor environment. From January to February 1998, subject experiment was 40 times proceeded under twenty different conditions of air temperature and relative humidity with early-twenty male university students. We examined subjective evaluation, Electrocardiogram(ECG), Electroencephalogram(EEG) of subjects. The results of this study can be summarized as follows : The comfort zone of people in winter was achieved at Standard new effective temperature($SET^*$) $ 25.2^{\circ}C$, PMV range was obtained by Fanger's statistical calculation was -0.27<PMV<+0.62, TSV range obtained subjects vote was -0.76<TSV<+0.36. The largest difference of skin temperature was found at the calf area as air temperature changes. vote rate of human body presented calflongrightarrowheadlongrightarrowforearmlongrightarrowchestlongrightarrowabdo men in turn. Heart rate was decreased at low $SET^*$ and heart rate was increased at high $SET^*$ But there was no change at EEG.

  • PDF

Characteristics of Thermal Comfort in Environment Chamber for Winter

  • Kim, Kyung-Hoon;Park, Jong-Il;Song, Yong-Gil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권1호
    • /
    • pp.73-83
    • /
    • 2000
  • The purpose of this study is to analyze and characterize the correlation of the thermal comfort sensation with physiological responses for men in winter indoor environment. A number of experiments were conducted under twenty different environmental conditions with college male students. Clinical information on each participant was reported in terms of electrocardiogram (ECG), electroencephalogram (EEG) and self-centered evaluation. The comfort zone in winter is found, throughout the study, at Standard New Effective Temperature (SET$T^+$) of 25.2$^{\circ}C$, Predicted Mean Vote (PMV) between 0.27 and 0.62, and Thermal Sensation Vote (TSV) in the range of -0.76 and 0.36. The largest difference in skin temperature is measured at the calf area with respect to air temperature changes. Skin sensitivity to environment temperature is explained as calf, head, chest and abdomen in descending order. Change in heat rate is analyzed to be in parallel with that of SET$T^+$.

  • PDF

자외선 영역에서 별의 색지수와 온도의 상관관계 (THE STELLAR COLOR-TEMPERATURE RELATION IN ULTRAVIOLET REGION)

  • 최영준;한원용;강영운;이우백
    • Journal of Astronomy and Space Sciences
    • /
    • 제15권2호
    • /
    • pp.321-333
    • /
    • 1998
  • 자외선 영역에서 별의 색 지수와 유효온도와의 상관관계를 구하기 위해서 118개의 IUE(Inter-national Ultraviolet Explorer) 표준성에 대해서 유효온도와 자외선 영역에서의 색 지수를 구하였다. 별의 유효온도는 IUE 저 분산 스펙트럼을 차등 보정 법을 이용하여 Kurucz 대기모델(1993)에 fitting하여 구하였고, 자외선 영역에서의 색 지수는 2750 $\AA$과 2950 $\AA$에서의 등급 차이로 정의하였다. Kurucz 대기모델(1993) fitting으로 구한 온도는 다른 논문(Malagnini & Morossi 1990, Malagnini et al. 1986)에서 구한 온도와 낮은 온도의 낮은 온도의 별을 제외하고 대체로 비슷하였으며, 자외선영역에서의 색 지수와 유효온동의 상관계 또한 Kurucz 대기모델에서의 결과와 비슷하게 나타났다.

  • PDF

자외선 스펙트럼을 이용한 별의 표면온도 결정 (DETERMINATION OF STELLAR SURFACE TEMPERAURE USING ULTRAVIOLET SPECTRA)

  • 강영운;지나현;한미려;최영준;한원용;이우백
    • Journal of Astronomy and Space Sciences
    • /
    • 제15권1호
    • /
    • pp.91-100
    • /
    • 1998
  • 자외선 영역에서 색지수와 유효온도의 상관관계를 구하기 위한 pilot project 로 25개의 표준상태에 대하여 유효온도와 색지수를 산출하였다. 유효온도는 자외선 영역의 IUE 저분산 스펙트럼의 에너지 분포 곡선을 Kurucx 모델과 비교하여 산출하였고, 자외선 색지수는 IUE 저분산 스펙트럼의 플럭스를 $300{\AA}$ 단위로 적분하여 등급으로 환산하여 산출하였다. 자외선 영역으 상관관계는 가시관선 영역의 상관관계와 유사한 형태로 나타났다.

  • PDF

인공오염포의 세탁조건에 따른 세척효율에 관한 연구 - 세제농도와 용수온도를 중심으로 - (A study on the washing efficiency with various washing conditions - Focus on detergent concentration and temperature -)

  • 최인려;김태미
    • 복식문화연구
    • /
    • 제22권3호
    • /
    • pp.503-510
    • /
    • 2014
  • Nowdays, costumer's washing behavior were often times for remove to light-duty dirt. The purpose of this study is to provide the most effective washing conditions of detergent concentration and temperature conditions for help save energy and water resources required to the washing process. Washing conditions were as follows: 2 kinds of detergents and 4 types of artificially soiled fabrics were used. Detergent concentration was 0%, -10%, and -20% below the recommended conc. of manufacturer's standard. Temperature of bath was $20^{\circ}C$ and $40^{\circ}C$. The results of this study were as follows: First, washing performances of all kind of artificially soiled fabric improved as the temperature of bath at $40^{\circ}C$. Second, the test was conducted under the condition of decreasing respectively -10% and -20% below of the recommended concentration of manufacturer's standard detergent. The average of washing efficiency was not considerably affected by the reduction of 10% below of manufacturer's standard. Third, in case of the water temperature were $20^{\circ}C$, polyester/cotton blended fiber were higher degree of washing efficiency than cotton fiber.

강상자형교의 강바닥판에서 설계온도하중을 위한 유효온도 산정 (Evaluation of Effective Temperature for Estimate Design Thermal Loads in Steel Deck of Steel Box Girder Bridges)

  • 신동욱;김경남;최철호;이성행
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권6호
    • /
    • pp.77-87
    • /
    • 2013
  • 국내 교량 설계에서 온도 하중에 대한 현재 LSD (한계 상태 설계법)는 다양한 교량 형식에 대한 동일한 기준을 적용하고 있다. 본 연구에서는 유효 온도를 산정하기 위해 실제 크기의 상판이 없는 강상자형거더교 시험체를 제작하였다. 1년동안 강상자형거더교모형의 18개 지점에서 온도데이터를 측정하였다. 측정된 데이터를 바탕으로 대기 온도에 따른 교량단면내 유효 온도를 산정 하였다. 유로 코드의 유효 온도와 비교할 때 실측 유효온도의 결과는 매우 유사한 상관 관계를 보였다. 따라서, 본 데이터를 기반으로 산정 된 유효 온도는 국내 교량 설계에 온도 하중에 적합한 설계 기준을 제시하기 위한 기초 자료로 사용할 수 있다.

콘크리트 박스거더교의 설계 유효온도 산정을 위한 실험적 연구 (Experimental Study on the Effective Temperature Calculation of Concrete Box Girder Bridge)

  • 이성행
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.740-745
    • /
    • 2020
  • 콘크리트 박스거더교의 합리적인 설계 온도하중을 산정하기 위하여, 1개의 교량시험체를 제작하였다. 교량시험체에 설치된 23개의 온도 게이지에서 1년간의 여름과 겨울기간에 30분 간격으로 하루에 48세트의 온도를 측정하였다. 상부 콘크리트와 측벽, 하부슬래브에 두께에 따른 온도변화를 검토하기 위하여 두께에 따라 여러 온도게이지를 부착하였다. 각 측점에서 측정된 온도를 통계 처리하여 추세선과 표준오차를 산정하고, 대표측점의 온도분포와 추세선을 제시하였다. 이를 바탕으로 Euro code에서 제시한 대기온도에서 여름철의 최고 유효온도와 겨울철의 최저 유효온도를 각각 산정하였다. 최고 유효온도는 35℃ 이상에서 Euro code와 비교하여 1.5~2℃ 높게 산정되었고, 최저 유효온도는 -13℃~-19℃에서 0.5~1.1℃로 더 낮게 분석되었다. 양산지방의 50년빈도 최고 및 최저 기온에 따른 본 연구의 유효온도와 비교해 보면, 최고 유효온도는 4.7℃ 높게, 최저 유효온도는 4.5℃ 더 낮게 산정되었다. 점점 높아지는 기후변동을 고려하고, 본 분석의 결과를 반영하면, 현 온도설계기준은 그 범위를 더 크게 하는 것이 필요한 것으로 판단된다.

기후학적 평년 표준편차 분포도의 상세화 (Estimation of Climatological Standard Deviation Distribution)

  • 김진희;김수옥;김대준
    • 한국농림기상학회지
    • /
    • 제19권3호
    • /
    • pp.93-101
    • /
    • 2017
  • 2011-2015년까지 경남 하동군 악양 집수역의 해발고도 8~1,073m 범위에 설치된 10개 무인기상관측기에서 0600, 1500 기온 관측값을 수집하여 월별 표준편차를 계산하고, 소기후모형으로부터 예측된 기온의 표준편차 결과를 함께 비교하여 미관측 지점의 추정기술에 실효성이 있는지 평가하였다. 소기후모형에 따른 예측값은 월별 0600, 1500 기온의 표준편차를 각각 88%, 86% 정도 설명할 수 있었지만, 전반적으로 과소추정하는 경향이었다. 겨울철과 여름철에 나타나는 낮은 고도 대비 해발고도가 높아질수록 변이가 작아지거나 커지는 방향성에 있어서 관측값과는 반대양상으로 나타나 당초 기대와는 다른 결과를 보였다. 또 다른방법으로 월별 기온 표준편차와 지형간의 관계를 정량화하여 임의지역의 지형특성과 종관규모 수준의 기온자료 만으로 표준편차 분포를 예측할 수 있을지 회귀분석을 수행하였다. 회귀모형은 해발고도편차에 따라 보정된 월별 기온 외에, 경사도와 경사향 등 기본적인 지형인자와 온난대효과와 냉기집적효과, 개방도 등의 기온과 관련된 변수들을 고려하여 월별로 표준편차를 가장 잘 설명할 수 있는 변수를 1~3개까지 선발하여 만들어졌으며, 월별 결정계수는 0.46부터 0.98 범위로 나타났다. 회귀모델을 이용해 기온이 관측되지 않는 임의지역의 표준편차를 지형변수의 최소-최대값 유효범위 내에서 월별로 예측한다면 70% 수준의 추정능력으로 공간변이 분포도를 나타낼 수 있을 것으로 예상된다.

수면유도용 온열안대를 위한 뇌파기반의 맞춤형 온열제어 기법 (Customized Eyelid Warming Control Technique Using EEG Data in a Warming Mask for Sleep Induction)

  • 한혜경;이병문
    • 한국멀티미디어학회논문지
    • /
    • 제24권8호
    • /
    • pp.1149-1160
    • /
    • 2021
  • Lack of sleep time increases risks of fatigue, hypomnesis, decreased emotional stability, indigestion, and dementia. The risks can be reduced by providing eyelid-warming, inducing sleep and improving sleep quality. However, effective warming temperature to an person varies depending on physical condition and the individual. The various types of frequencies can be identified in brain wave from a person and amount of frequencies is also changed continuously before and after sleep. Therefore we can identify the user's sleep stage with brain wave, namely EEG. Effective sleep induction is possible if warming temperature to a person is controlled based on EEG. In this paper, we propose customized warming control techniques based on EEG for a efficient and effective sleep induction. As an experiment, sleep induction effects of standard sleep mask and customized temperature control techniques sleep mask are compared. EEG data and warming temperature were measured in 100 experiments. At customized warming control techniques, experiments showed that the ratio of alpha and theta waves increased by 3.21%p and the time to sleep decreased by 85 seconds. It will contribute to effective sleep induction and performance verification methods in customized sleep mask systems.