• Title/Summary/Keyword: Standard DEA

Search Result 55, Processing Time 0.022 seconds

Assessment of Both Standard and Isolated Vibrio parahaemolyticus on Efficacy of Commercial Sanitizers and Disinfectants (Vibrio parahaemolyticus 표준 및 식품분리 균주에 대한 살균소독제 유효성분별 감수성 평가)

  • Kim, Il-Jin;Kim, Yong-Su;Kim, Hyung-Il;Choi, Hyun-Chul;Jeon, Dea-Hoon;Lee, Young-Ja;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.2
    • /
    • pp.127-131
    • /
    • 2007
  • This study evaluated the bactericidal effect of 10 sanitizers and disinfectants such as ethanol (75 and 95%), iodine (15 and 25 ppm), chlorine (100 and 200 ppm), quaternary ammonium, acid, hydrogen peroxide, and peroxide acetic acid against V. parahaemolyticus. Ten strains of V. parahaemolyticus isolated from Korean foods and 4 strains of standard V. parahaemolyticus were compared for efficacies of various sanitizers and disinfectants by EN 1276 method based on quantitative suspension test. Ethanol (75 and 95%), 25 ppm of iodine, 100 ppm of quaternary ammonium, 145 ppm of hydrogen peroxide and acid showed more than $5log_{10}CFU/mL$ reduction in both clean and dirty conditions. Tests result of chlorine (100 ppm) showed more than $5log_{10}CFU/mL$ reduction in clean condition. Iodine (15 ppm) showed more than $5log_{10}CFU/mL$ reduction except 4 isolated and 1 standard V. parahaemolyticus in clean condition. iodine (15 ppm) also showed under $5log_{10}CFU/mL$ reduction $(0.93{\sim}3.73log_{10}CFU/mL)$ in dirty condition. Eleven hundred ppm of hydrogen peroxide was evaluated as weak sanitizer and disinfectant due to their $0.99{\sim}4.79log_{10}CFU/mL$ reduction on both clean and dirty conditions. Consequently, ethanol, iodine (25 ppm), chlorine (200 ppm), quaternary ammonium, acid and peroxide acetic acid were thought to be effective sanitizer and disinfectant against V. parahaemolyticus.

Evaluation of the Site Specific Ground Response in Korean Urban Site (국내 도시지역의 지반응답특성 거동 평가)

  • Shin, Dea-Sub;Kim, Hu-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.250-255
    • /
    • 2017
  • When an earthquake occurs, it is necessary to evaluate the site-specific ground response while considering ground characteristics in seismic design. The design seismic force of Korean seismic design criteria is borrowed from the Uniform Building Code(UBC-1997). However, the criteria are based on the ground characteristics of the United States, which are different from the ground characteristics in Korea, and using them could cause over-or under-designing. Therefore, it is important to develop a proper design response spectrum for Korean ground characteristics. In this study, 158 ground sites in Korean urban areas were selected and compared to those in the western part of the United States, and their site-specific ground responses were analyzed. The classification standard in the seismic design criteria classifies the 158 sites into 37 sites, 107 sites, and 14 sites. Using 7 earthquake inputs, the criteria were compared for each group.The Korean design response spectrum underestimates the amplification of the short-period range and overestimates the amplification in the long-period range. There were large differences in the results of the and sites,which account for 77 percent of the 158 sites. Therefore, there is a need to modify the amplification factor in the Korean seismic criteria to properly reflect Korean ground characteristics.

Study on the Correlation between the Change in SAR and Temperature of the Human Head by use Dental Implant on 3.0T Brain MRI : Using the XFDTD program (3.0T Brain MRI 검사 시 치아임플란트 시술 유무와 인체의 SAR, 체온 변화와의 상관관계에 관한 연구 : XFDTD 프로그램을 이용)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.139-146
    • /
    • 2017
  • At the Brain MRI examination, RF Pulse are irradiated on the human head in order to acquire MR images. At this time, a considerable part of the irradiated RF Pulse energy is absorbed in our body and the temperature of the human head will rise depending on the degree of exposure, so it will affect the human head. Even if the same RF Pulse energy is given, if the metal is inserted in the human head, the conductivity of the human head is greatly increased by the metal, so the SAR value increases and the temperature also rises. Therefore, we started this research with the question as to whether there is difference between the change in SAR value and temperature displayed on the head of the human according to use or not of the dental implant. Experiments were using the XFDTD program on a 128 MHz RF Pulse frequency by a 3.0 tesla MRI. We can see that both are increasing that the average value of SAR and temperature that absorbed by the human head model used the dental implant. In addition, the average maximum SAR value and the maximum temperature rise in the brain part are shown below the international safety standard value but the influence can not be ignored because of the result may change according to the increase in the number of dental implant. And as future tasks. we need to the simulation of temperature rise and SAR due to an increase in the number of implants and volumes of teeth, dental implant material.

Termite Resistance of The Less Known Tropical Woods Species Grown in West Java, Indonesia

  • Febrianto, Fauzi;Pranata, Andi Zaim;Septiana, Dea;Arinana, Arinana;Gumilang, Adiyantara;Hidayat, Wahyu;Jang, Jae-Hyuk;Lee, Seung-Hwan;Hwang, Won-Joung;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.2
    • /
    • pp.248-257
    • /
    • 2015
  • This research focused on the natural durability of twenty one lesser known tropical wood species planted in West Java, Indonesia against subterranean termite (Coptotermes curvignathus). It was observed that both heartwood and sapwood of Kiara payung (Filicium decipiens); heartwoods of Nangka (Arthocarpus heterophyllus), Mahoni (Swietenia macrophylla) and Simpur (Dillenia grandifolia); and sapwood of Bungur (Lagerstroemia speciosa) were rated as resistant (natural durability class II) according to Indonesian standard SNI 01.7207.2006 (BSN 2006). Both heartwood and sapwood of Salam (Syzigium polyanthum), Pasang (Lithocarpus sundaicus), Bisbul (Diospyros discolor), Rukam (Flacourtia rukam) and Trembesi (Samanea saman); heartwood of Puspa (Schima walichii), Bungur, Tanjung (Mimusops elangi) and Angsana (Pterocarpus indicus) were rated as moderately resistant (natural durability class III). Both heartwood and sapwood of Sungkai (Peronema canescens), Pine (Pinus merkusii), Mangium (Acacia mangium) and Afrika (Maesopsis eminii); sapwoods of Mahoni, Puspa and Tanjung were rated as poorly resistant (natural durability class IV). Both heartwood and sapwood of Agathis (Agathis dammara), Durian (Durio zibethinus), Ki sampang (Evodia latifolia) and Jabon (Anthocephalus cadamba); sapwoods of Nangka and Angsana were rated as very poorly resistant (natural durability class V). This reserach showed that woods with lower resistance against C. curvignathus attack (natural durability class IV and V) tend to have lower termite mortality values compared to woods with higher resistance against C. curvignathus attack (natural durability class II and III). Results of the study will provide some valuable information on termite resistance of twenty one lesser known tropical wood species planted in Indonesia.

A study on the design of tunnel lining insulation based on measurement of temperature in tunnel (터널 온도계측을 통한 라이닝 단열 설계에 관한 연구)

  • Kim, Dea-Young;Lee, Hong-Sung;Sim, Bo-Kyoung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.4
    • /
    • pp.319-345
    • /
    • 2011
  • In case of tunnels in cold regions, a freeze of groundwater around tunnel may act as a barrier of tunnel drainage in winter, or may cause the inner extrusion of lining. In spite of that, a design of insulation for preventing the frost damage of tunnel lining has not been introduced in Korea, while foreign countries such as Norway and so on have a standard on insulation. In this study, a few freezing cases of road tunnels have been reviewed, and the results show that the freezing protection is necessary. In order to characterize the thermal distribution in the tunnel, following measurements have been performed at Hwa-ak tunnel; the temperature distribution by longitudinal lengths, the internal temperature of lining and the temperature distribution of the ground under pavement. From these measurements, the characteristics of the tunnel's internal temperature distribution due to temperature change in the air has been analyzed. Based on the measurement results on the temperature distribution at Hwa-ak tunnel, thermal flow tests on the rock specimen with and without insulation have been performed in the artificial climate chamber to investigate the performance of the insulation. Also, a number of 3D numerical analyses have been performed to propose appropriate insulation and insulation thicknesses for different conditions, which could prevent the frost damage of tunnel lining. As a result of the numerical analysis, air freezing index of 291$^{\circ}C{\cdot}$ Hr has been suggested as the threshold value for freezing criteria of groundwater behind the tunnel lining.