• Title/Summary/Keyword: Standard Bedroom

Search Result 34, Processing Time 0.018 seconds

A Study on the Analysis of Space Arrangement in 'Standard Korea Traditional-Houses Design' (한옥표준설계도의 평면도 공간배치 분석에 관한 연구)

  • Hwang, Yong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.579-586
    • /
    • 2019
  • The object of this study are 32 floor plans types of "Standard Korea Traditional-Houses Design=SKTHD.". The purpose of the research was to enhance the satisfaction level of users by comparing and analyzing the characteristics of the SKTHD. Research decision : 1. It tried to accommodate modern life by including space elements of modern housing, such as the 'entrance space', in the SKTHD. 2. The SKTHD. also favored the southern layout of living rooms and entrance spaces. 3.The number of bedrooms was generally planned to be two to three and it was judged that more various space and bedroom were needed to hold various functions of rural areas. 4. It has been analyzed that the depth of space is deeper to enter the entrance space(E)' than to enter from Thet-maru(TM). And as the depth of space in the Master bedroom is related to personal privacy, it is needed that the depth of space should be sufficiently.

Present State of Institute Composition and Reform Measures of Nursing Homes (노인요양시설의 시설구성 현황과 개선방안)

  • Yoo, Yong-Shik
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.10
    • /
    • pp.186-195
    • /
    • 2009
  • This research is intended to provide basal material on institute composition of nursing homes that will be built in the near future. According to the result, five of the passages are central type, one of them is extensive type, and the other is group type. Secondly, in living space bedroom area is widest, and both sizes of bedroom system and floor heating system are the same. Thirdly, the sizes of clinic room and physical therapy room are similarly widest in medical space, and people use physical therapy room most frequently. Fourth, dining room and kitchen area are widest in public space, and it is hard to move to program room. Fifth, office area is widest in superintendent space, and it is located near lobby on the first floor. Sixth, the dimension per individual doesn't reach the standard of bedroom size per individual. Seventh, in each space, the rate of whole dimension of living space is highest.

Design Criteria in Barrier Free Housing (장애물 없는 주택 설계기준에 관한 연구 - 국내 공동주택의 무장애(barrier free) 설계수준 평가를 중심으로 -)

  • Kim, Sang-Woon;Park, Kwani-Jae;Kang, Byoung-Keun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.10 no.2
    • /
    • pp.107-115
    • /
    • 2004
  • In this paper, the all units of residential housing that is not legislated in facility development law are analyzed and foreign design criteria that is related to barrier-free unit housing is comparing to domestic. Through the comparison in front door, living room, bathroom, bedroom, and kitchen, this paper aims to suggest internal barrier-free design criteria. This paper is limited to internal housing which are front door, living room, bedroom, bathroom, and kitchen. Also, the objectives of facility development law are U.S, Japan, German, and in case of U.S, UFAS is established by ADA, in Japan, Heart Building law and detail standard drawing are used, in German, DIN is used. The objective of domestic case study is the latest residential housings that are built over 2003. The flow of study is as follows ; First, the internal items of residential housing are abstracted, and each item is checked in facility development law that is legislated in. Next, through comparison of domestic and foreign facility development law related to housing, common items are abstracted and detail standards are defined. Domestic residential housings are analyzed in those standards. Finally, the problems that is the result of analysis are analyzed and the barrier free design criteria is abstracted in unit housing. Also, more developed items and future study are suggested.

  • PDF

Performance Analysis of the the Single Alarm Detector in the Rooms of Single Houses by Computer Simulation (시뮬레이션을 통한 주거공간 단독경보형감지기의 성능 분석)

  • Lim, Geun-Joo;Park, Sang-Cheon;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.29-35
    • /
    • 2020
  • This study was conducted to examine the performance in the space for a single alarm type detector installed in a single house. Three types of houses were used, including two types of one-story and two-story houses. A computer simulation program was used to predict the sound pressure level in response to the occurrence of an alarm sound in a residential space. The characteristics of the sound source applied to the simulation were directly measured and used as input data. As a result of simulation, it was found that the sound pressure level in the kitchen and living room generally met the standard when the alarm sound of the detector occurred. However, the sound pressure level in the bedroom was predicted to be at least 20 dB (A) lower than the American Fire Protection Association standard of 75 dB (A). Therefore, a plan should be prepared to maintain a sufficient sound level in the bedroom space inside the house, and efforts will be needed to ensure safe evacuation in case of fire by establishing relevant standards.

A Study on the proportion of functional Areas in the ward of General Hospitals (종합병원의 병동부 기능공간 구성비율에 관한 연구)

  • Kwon, Soonjung;Joo, Sohyeon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.4
    • /
    • pp.49-55
    • /
    • 2011
  • This study proposes proportions of functional areas in the ward of general hospitals, which are derived from 5 big university hospitals in order to establish the ward area standard for hospital design. The results of this paper are as follows. First, functional areas of hospital ward are composed of bedroom area, nursing area, training area, service area, and common area. Of course common area can be divided into first common area and secondary common area. The first common area(inter departmental common area) includes lobbies, elevator lobbies, corridors, restroom, and mechanical shafts. The secondary common area means the common area within special department such as ward or radiology department. Second, a standard method of calculating ward areas has been proposed: the standard is based on the center line of the wall between functional areas. Third, the proportions of 6 functional areas in ward are suggested.

A Study on the Improving Speech Intelligibility of Emergency Broadcast Equipment in the Apartments (공동주택 내 비상방송설비의 음성명료도 실태 분석 및 재실자 인지성 개선방안 연구)

  • Oh, So-Young;Cho, Hyun-Min;Lee, Young-Ju;Lee, Min-Joo;Yoon, Myung-Oh
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.60-68
    • /
    • 2018
  • Due to the complicated plan structure of the apartment units and the improved room-to-room sound insulation performance, it is difficult to communicate and recognize the fire situation by emergency broadcast equipment. In this study, speech intelligibility was measured and analyzed for three types of apartment unit by emergency broadcast equipment on various measurement points. Simulations were also conducted to improve the speech intelligibility. As a result of field measurements 72, 84, and 101 Type were not satisfied with NFSC standard of 90 dBA at the point of 1 m distance from source. In addition, it was evaluated that 75 dBA and CIS 0.7 of NFPA standard was not satisfied at all measurement points except for the 72 Type at living room point with door opened condition. Based on the door opened condition of the bedroom, it satisfied the NFPA of 75 dBA and CIS 0.7 in each bedroom when more than 90 dBA was satisfied at the 1 m separation point provided in NFSC standard.

Planning Factor of the Housing for the Disabled and Aged based on the Inclusive Housing (포괄적 주택개념에 기초한 장애인 및 노인주거 계획요소)

  • Kim, Mingyeong;Nam, Younok
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.4
    • /
    • pp.57-68
    • /
    • 2011
  • The purpose of this study is to provide the planning factors of housing for the disabled and elderly based on the inclusive housing design as sustainable neighborhood. The goal of inclusive design is to make buildings and communities more livable for all type of people. Inclusive design should embrace other good design goals and reinforce them, not work against them. To carry out this purpose, we should proceed in the following way: First, we deducted the four design factors (the basic, recommendable, adaptable, and residential factors) by reviewing the characteristics of inclusive housing concepts. Second, we analyzed the related foreign design standards and guidelines such as the ICC/ANSI A117.1 Type C Units (the United States, 2009), Lifetime Standard (the United Kingdom, 2010), and Livable Housing Design Guideline (the Australian, 2010) through four design factors based on inclusive design concepts. Finally, we suggested the housing design factors for the disabled and the elderly in Korea. To conclude, we can make the followings: It is important basic factor that the bedroom and bathroom layout closed to each other. Also, the bedroom has the proper height of light switches, outlets, and windows. The recommendable factors take into consideration stairs and ramp, if existent. The adaptable factors are closely related to domestic housing culture as well as residential factors. Proceeding from this fact, the livability for people with disabilities and older requires accessibility and adaptability that take into account public and efficiency considering the current trend of housing development and urban planning.

A Comparative Study on The Barrier Free Dwelling Guidelines of Domestic and Foreign Countries -Focused on Entrance, Bedroom and living room (무장애 주택설계에 관한 국내외 국가표준의 비교 연구 -현관, 침실, 거실을 중심으로)

  • Lee, Ho Sung;Choi, Chan-Hwan;Lee, Teuk-Koo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.16 no.1
    • /
    • pp.65-75
    • /
    • 2010
  • This is a comparative study mainly on foreign countries' domestic standards and laws on barrier free housing construction that can be applied to the dwelling of elderly friendly apartment housing. Eight countries - the United States, Germany, Canada, Switzerland, the United Kingdom, Australia, Japan, and China - were reviewed as foreign cases. The analyzed subjects were design standards only for the disabled and the aged. To compare barrier-free guides of the eight countries, each barrier-free guide on three space units (entrance, bedroom, living room) was divided into 11 design items and 36 design factors. The comparative analysis on foreign cases was based on the design guide according to Korea's KS P 1509 (principle and recommendation for designing dimension of dwelling in consideration of the elderly). Some factors -if with dimensions- were compared by means of the skewness of distribution. In the analysis result, there were not only common standards for the nine countries such as a dimension of the space for wheelchair movement but also different standards such as heights of outlets and horizontal lengths of bathtub grab bars. The detailed analysis shows that it is urgently necessary to prepare new domestic national design standards for 8 factors that foreign countries already have. It is also needed to immediately prepare dimension standards for the design factors, which have no detailed dimensions but only national guides, in consideration for anthropometric dimension.

A Comparative Analysis on Concentration of Pollutants in Housing Indoor-Air between Winter and Summer (주택 실내 공기중 오염물질 농도의 동절기와 하절기 비교 분석)

  • Nam, Ki-Cheul;Lee, Young-Han;Choi, Bong-Seok
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.125-131
    • /
    • 2017
  • Purpose: The study is to measure concentrations of indoor air pollutants in housing and to analyze the characteristics of pollutants in housing indoor-air between summer and winter comparatively. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in winter which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. The characteristics of HCHO, TVOC, $CO_2$ concentration in winter were analyzed and then the concentrations in winter were analyzed the concentrations in summer being preceding research comparatively. Result: Average concentration of TVOC in winter was 2.7 times more than that of TVOC in summer, average concentration of HCHO in winter was about 2.0 times more than that of HCHO in summer. Average concentration of $CO_2$ in the morning at living room in winter was 1.3 times more than that of $CO_2$ in summer. Average concentration of $CO_2$ in the morning at master bedroom in winter was 1.1 times more than that of $CO_2$ in summer. Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close or over to 1,000ppm being criteria of the Ministry of Environment.

Analytical Study for the Plan of Unit Household in National Housing Scale - Oriented on the cases of Korea housing corporation since 2005 ; Focused on analysing area (국민주택규모 단위세대 평면 분석 연구 - 2005년 이후 대한주택공사 사례를 면적분석 중심으로 -)

  • Lee, Jeong-Ho;Lee, Chan
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.1
    • /
    • pp.180-189
    • /
    • 2010
  • Since collective houses are started to be supplied, the housing market has been transformed from supplier to demander oriented, and various type with same area of unit households have been deigned and started to be distributed. It can be expected that such transfer phenomenon would be continuously sped-up, and unit household will be more subdivided and varied. Thus, we analysed and studied the planes with subject of unit households in national housing scale ($85m^2$) that is treated as supply standard and has biggest volume in construction by Korean housing corporation. The analysing method is investigating the area of each room within unit household, calculating their minimum, maximum, and average values, studying the efficiency of unit household plane according to the structure of each room by comparative analysis these values, and analysing changing matter by investigating any change of each room area. The analysing results of which are followings. At first, number of BAY on face is increasing. Second, allocation of each room has been vary. Third, area ratio among bedroom1, livingroom, diningroom/kitchen become similar. Fourth, the area of diningroom/kitchen become somewhat bigger. Fifth, the space for passage way is efficiently allocated. Sixth, service area is reduced, Seventh, stereotyped phenomenon Is appeared. Based on many studies so far, any improvements of unit householder in national housing scale are followings. First, in terms of forming style, unit householder in national housing scale is unfolded in various way though, the form of each room is not more than typical style. Second, it shows stereotyped phenomenon. Especially, bathroom 1, 2 show stereotyped feature in terms of their type and area across entire research years, also LDK allocation method is stereotyped, as well as stereotyped trend in bedroom 2, 3, allocation for 4 BAY type.