• 제목/요약/키워드: Stall

검색결과 471건 처리시간 0.026초

도로변 구두수선대 실내.외의 이산화질소 농도 및 거리에 따른 이산화질소 감소 - 서울시와 아산시의 비교 연구 - (Indoor and Outdoor $NO_2$ Concentration of Shoe-stall near Busy Road and $NO_2$ Decay by Distance from Roadside - Comparative Study between Seoul and Asan -)

  • 양원호;손부순;박종안;김종오
    • 환경위생공학
    • /
    • 제17권2호
    • /
    • pp.85-91
    • /
    • 2002
  • Workers who work at indoor and outdoor environment near busy road are suspected to be exposed to high-elevated air pollutant levels during working hours. This study evaluated the working-time nitrogen dioxide ($NO_2$) exposure for workers (repairmen and polishers) of shoe-stalls. Since shoe-stalls have particularly been located near busy road in Korea, workers might be high exposure to $NO_2$ from traffic exhaust as well as indoor sources of shoe-stall such as portable gas range (butane gas) during working hours. In this study, we measured the indoor and outdoor $NO_2$ concentrations of shoe-stalls. Simultaneously, outdoor $NO_2$ concentrations of building through sidewalk from shoe-stall were measured. High $NO_2$ exposure for workers of shoe-stalls was considered to be inflow of outdoor source of exhausted emission from vehicles and indoor source from usage of gas range to polish the shoe. Indoor/outdoor $NO_2$ concentration ratio ($0.94{\pm}0.22$) in Seoul was higher than that ($1.06{\pm}0.34$) in Asan, because ambient $NO_2$ level was high in Seoul and usage of gas range was prevalent in Asan. According to $NO_2$ concentrations by distance from roadside to building through sidewalk, $NO_2$ concentrations showed the decreased trend with distance. The results of this study can be utilized by municipal authorities in urban planning for evaluating effects of future traffic planning and land use.

동적실속 수동제어장치 최적설계 (Design Optimization of Passive Control Devices for Dynamic Stall Control)

  • 주완돈;이보성;이관중;이동호
    • 한국항공우주학회지
    • /
    • 제33권1호
    • /
    • pp.11-19
    • /
    • 2005
  • 본 연구에서는 진동 운동하는 익형의 동적실속 특성을 향상시키기 위하여, 고정 앞전 Droop과 Gurney 플랩의 크기와 위치에 대한 최적설계를 수행하였다. 고정 앞전 Droop이 모멘트 특성의 개선에 효율적이나 양력특성의 저하를 유발 할 수 있다. 반면에 Gurney 플랩은 양력특성의 향상을 가져오지만, 모멘트특성을 악화시키는 특성이 있다. 고정앞전 Droop의 설계변수는 상호 보완적인 특성을 갖는 위치와 각도를 설정하였으며, Gurney 플랩은 그 길이를 설계변수로 설정하였다. 또한, 동적실속과 같이 비선형성이 강한 문제의 설계를 위해서 고차 다항식의 반응면 기법과 민감도 기반의 최적설계 기법을 사용하였다. 최적화는 양력과 모멘트 특성이 동시에 개선되도록 수행 하였다. 설계 결과 동적실속의 양력, 모멘트 및 항력특성의 향상을 가져올 수 있었으며, 가변 앞전 Droop과 Gurney 플랩을 결합한 능동제어장치에 버금가는 동적실속 제어 효과를 갖을 수 있음을 확인하였다.

대형 석탄화력 발전소에서 통풍계통 안정화를 위한 과잉공기비 조정 (Adjustment of the Excess Air Ratio for Stabilizing the Draft System in a Large Capacity Coal Fired Power Plant)

  • 박건우;유호선
    • 플랜트 저널
    • /
    • 제14권2호
    • /
    • pp.39-44
    • /
    • 2018
  • 본 연구에서는 870 MW 대형 석탄화력 발전소에서 출력을 고정시키고 과잉공기비 조정만으로 통풍계통 안정 및 보일러 효율에 어떠한 변화가 있는지를 분석하였으며 이에 따른 적정 과잉공기비를 선정하였다. 과잉공기비 조정에 따라 공기예열기 압력강하, 유인송풍기 실속여유 등이 변하므로 통풍계통 안정화를 위해 적정 과잉공기비 선정은 반드시 필요하다. 따라서 본 연구에서는 과잉공기비를 통상 운전 값인 1.153에서 운전지침서상의 하한 값인 1.127까지 단계적으로 조정하여 공기예열기 압력강하, 유인송풍기 1차 실속여유, 보일러 효율, 각종 손실 등을 측정하였고 보일러 효율도 동등수준이상으로 유지하면서 통풍계통도 위험수준에서 안전하게 이격시켜 안정화에 기여할 수 있는 적정 과잉공기비를 선정하였다. 적정 과잉공기비는 운전지침서 상의 하한 값인 1.127까지 낮추어 운전하는 것이 바람직하다고 판단된다.

  • PDF

A Comparative Study of Numerical Methods on Aerodynamic Characteristics of a Compressor Rotor at Near-stall Condition

  • Kim, Donghyun;Kim, Kuisoon;Choi, Jeongyeol;Son, Changmin
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권2호
    • /
    • pp.157-164
    • /
    • 2015
  • The present work performs three-dimensional flow calculations based on Reynolds Averaged Navier-Stokes (RANS) and Delayed Detached Eddy Simulation (DDES) to investigate the flow field of a transonic rotor (NASA Rotor 37) at near-stall condition. It is found that the DES approach is likely to predict well the complex flow characteristics such as secondary vortex or turbulent flow phenomenon than RANS approach, which is useful to describe the flow mechanism of a transonic compressor. Especially, the DES results show improvement of predicting the flow field in the wake region and the model captures reasonably well separated regions compared to the RANS model. Besides, it is discovered that the three-dimensional vortical flows after the vortex breakdown from the rotor tip region are widely distributed and its vortex structures are clearly present. Near the rotor leading edge, a part of the tip leakage flows in DES solution spill over into next passage of the blade owing to the separation vortex flow and the backflow is clearly seen around the trailing edge of rotor tip. Furthermore, the DES solution shows strong turbulent eddies especially in the rotor hub, rotor tip section and the downstream of rotor trailing edge compared to the RANS solution.

가변 디퓨저를 장착한 원심 압축기 불안정성 연구 (A Study on the Instabilities of the Centrifugal Compressor with Variable Diffuser)

  • 차봉준;임병준;양수석
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1123-1131
    • /
    • 2002
  • An experimental study on the performance and instability development characteristics of a centrifugal compressor equipped with a cambered variable diffuser has been performed with varying diffuser vane angles. The test was conducted at the design speed of 20,800 rpm and the 80% design speed of 16,640 rpm for 5 diffuser angles : 65$^{\circ}$, 70$^{\circ}$, 75$^{\circ}$, 77.5$^{\circ}$, 80$^{\circ}$ The steady performance test results showed that choking mass flow rate decreases and total pressure ratio increases with a narrowed surge margin as the diffuser vane angle increases. Unsteady pressures were measured using high-frequency pressure transducers at the inducer and the diffuser throat to investigate the instability phenomena such as rotating stall and surge inside the compressor. From the unsteady measurements, it is found that the transient process from rotating stall to surge was mainly affected by diffuser angles. The results of the present study can be applied to the instability control of the centrifugal compressors using a variable diffuser.

A Study on the Fundamental Surge Frequencies in Multi-Stage Axial Flow Compressor Systems

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권4호
    • /
    • pp.160-173
    • /
    • 2014
  • Surge phenomena in multi-stage axial flow compressors were studied with attention to the frequency behaviors. A new parameter "volume-modified reduced surge frequency" was introduced, which took into consideration the essential surge process, i.e., emptying and filling of the working gas in the delivery plenum. The behaviors of the relative surge frequencies at the stall stagnation boundaries, compared with the corresponding duct resonance frequencies, have demonstrated the existence of two types of surges; i.e., a near-resonant surge and a subharmonic surge. The former, which has fundamentally a near-resonance frequency, occurs predominantly at the stall stagnation boundary for the short -and-fat plenum delivery flow-path and the long-and-narrow delivery duct flow-path, and possibly in the intermediate conditions. The latter, which has a subharmonic frequency of the fundamental near-resonant one and occurs mainly in the intermediate zone, is considered to be caused by the reduced frequency restricted to a limited range. In relation with those dimensionless frequencies at the stall stagnation boundary, the surge frequency behaviors in more general situations away from the boundaries could be estimated, though very roughly.

입구 경계층 두께가 축류 압축기 내부 유동에 미치는 영향 (II) - 손실구조 - (Effects of the Inlet Boundary Layer Thickness on the Flow in an Axial Compressor(II) - Loss Mechanism -)

  • 최민석;박준영;백제현
    • 대한기계학회논문집B
    • /
    • 제29권8호
    • /
    • pp.956-962
    • /
    • 2005
  • A three-dimensional computation was conducted to make a study about effects of the inlet boundary layer thickness on the total pressure loss in a low-speed axial compressor operating at the design condition ($\phi=85\%$) and near stall condition($\phi=65\%$). Differences of the tip leakage flow and hub corner-stall induced by the inlet boundary layer thickness enable the loss distribution of total pressure along the span to be altered. At design condition, total pressure losses for two different inlet boundary layers are almost alike in the core flow region but the larger loss is generated at both hub and tip when the inlet boundary layer is thin. At the near stall condition, however, total pressure loss fer the thick inlet boundary layer is found to be greater than that for the thin inlet boundary layer on most of the span except the region near hub and casing. Total pressure loss is scrutinized through three major loss categories in a subsonic axial compressor such as profile loss, tip leakage loss and endwall loss using Denton's loss model, and effects of the inlet boundary layer thickness on the loss structure are analyzed in detail.

원심압축기 임펠러의 형상 변화에 따른 저유량 영역에서 발생하는 불안정 유동 평가 (Flow Instability Assessment Occurring in Low Flow Rate Region According to the Change of a Centrifugal Compressor Impeller Shape)

  • 조성휘;김홍집;이명희
    • 한국유체기계학회 논문집
    • /
    • 제19권2호
    • /
    • pp.21-26
    • /
    • 2016
  • The objective of present study is to assess the performance of the first stage compressor in a total 3-stage 5000 HP-level turbo compressor. CFD commercial code, CFX has been used to predict three-dimensional flow characteristics inside of the impeller. Shear Stress Transport (SST) model has been used to simulate turbulent flows through Reynolds-averaged Navier-Stokes (RANS) equations. Grid dependency has been also checked to get optimal grid distribution. Numerical results have been compared with the experimental test results to elucidate performance characteristics of the present compressor. In addition, flow characteristics of the impeller only have been studied for various blade configurations. Angular offset in leading edge of the blade has been selected for the optimal blade design. Performance characteristics in region of low mass flow rate and high pressure ratio between the impeller entrance and exit have been investigated for the selection of optimal blade design. Also, flow instability such as stall phenomena has been studied and anti-stall characteristics have been checked for various blade configurations in the operational window.

Surge Phenomena Analytically Predicted in a Multi-stage Axial Flow Compressor System in the Reduced-Speed Zone

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권3호
    • /
    • pp.110-124
    • /
    • 2014
  • Surge phenomena in the zone of reduced speeds in a system of a nine-stage axial flow compressor coupled with ducts were studied analytically by use of a surge transient simulation code. Main results are as follows. (1) Expansion of apparently stable, non-surge working area of the pressure vs. flow field beyond the initial stage-stall line was predicted by the code in the lower speed region. The area proved analytically to be caused by significantly mismatched stage-working conditions, particularly with the front stages deep in the rotating stall branch of the characteristics, as was already known in situ and in steady-state calculations also. (2) Surge frequencies were found to increase for decreasing compressor speeds as far as the particular compressor system was concerned. (3) The tendency was found to be explained by a newly introduced volume-modified reduced surge frequency. It suggests that the surge frequency is related intimately with the process of emptying and filling of air into the delivery volume. (4) The upstream range of movement of the fluid mass having once passed through the compressor in surge was found to reduce toward the lower speeds, which could have caused additionally the increase in surge frequency. (5) The concept of the volume-modified reduced surge frequency was able to explain, though qualitatively at present, the behaviors of the area-pressure ratio parameter for the stall stagnation boundary proposed earlier by the author.

폐쇄형 풍동 시험부내의 항공기 실속 흐름에 대한 Blockage 보정 기법 연구 (Blockage Correction Method for Separated Flows over an Aircraft in a Closed Test-Section Wind Tunnel)

  • 강승희;권오준;안승기
    • 한국항공우주학회지
    • /
    • 제33권8호
    • /
    • pp.42-49
    • /
    • 2005
  • 아음속풍동 폐쇄형 시험부의 벽면효과 보정을 위한 새로운 blockage 보정 기법을 개발하였다. 개발된 보정 기법은 실속항력계수와 separation blockage의 비선형 관계를 이용하여 선형 양력곡선 기울기 영역에서 후실속 영역까지 실시간으로 보정이 가능하게 하였다. 본 연구에서 제시한 방법은 bluff body 시험 결과를 사용하는 고전적 방법과 벽면압력측정 방법과 비교하여 그 타당성을 검증하였다. 그 결과 본 연구에서 제시한 보정 방법은 실속 및 후실속 영역에서 bluff body 방법보다 우수한 보정 결과를 보이며 벽면압력측정 방법과 같은 정확도로 보정됨을 확인할 수 있었다.