• Title/Summary/Keyword: Staircase safety

Search Result 26, Processing Time 0.024 seconds

Analytical Study to Check Safety of Folding-type Staircase in High Speed Rolling Stock (접이식 고속열차 승강문 스텝의 안전성 확인을 위한 해석적 연구)

  • Lee, Weon-Dae;Park, Sang-Kyu;Lee, Kyung-Kyu;Lee, Jeong-Hun
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.2
    • /
    • pp.87-93
    • /
    • 2014
  • The KTX, running in Korea but imported from Alstom Co. in France, has folding type staircases complying with European standard EN 4752. However, when operating, the step size is only 200mm, while the Korean standard step size is 253mm, a standard reflecting the average value of persons aged 20~60. From the aspect of kinesiology, the current step size can cause falls or slips during embarking and disembarking of passengers because body load is mostly focused on the heel and the current step is much more narrow than the standard size. Thus, we have performed an analytical study to check the safety of folding type staircases on the KTX after re-design.

Risk Model Development for PWR During Shutdown (원자로 정지 동안의 위해도 모델 개발)

  • Yoon, Won-Hyo;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 1989
  • Numerous losses of decay heat removal capability have occurred at U during stutodwn while its significance to safety is needless to say. A study is carried out as an attempt to assess what could be done to lower the frequency of these events and to mitigate their consequences in the unlikely event that one occurs. The shutdown risk model is developed and analyzed using Event/Fault Tree for the typical pressurized water reactor. The human cognitive reliability (HCR) model, two-stage bayesian approach and staircase function model are used to estimate human reliability, initiating event frequency and offsite power non-recovery probability given loss of offsite power, respectively. The results of this study indicate that the risk of a Pm at shutdown is not much lower than the risk when the plant is operating. By examining the dominant accident sequences obtained, several design deficiencies are identified and it is found that some proposed changes lead to significant reduction in core damage frequency due to loss of cooling events.

  • PDF

An Investigation of the Effect of the Height of Wteps on the Joint Moment of Lower Extremities of the Elderly While Walking Downstairs (노인의 계단 내려가기 동작 시 계단 높이와 하지 관절 모멘트와의 관계 연구)

  • Eun, Seon-Deok
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.31-38
    • /
    • 2006
  • The purpose of this study was to investigate the effect of changing the steps height on the joint moment of lower extremity in stair-descent activity of elderly persons. Data were collected by 3-D cinematography and force platform. 9 male elderly subjects in the 60s and 70s participated in this study. All subjects performed a stair-descent in four different heights of stairs (10, 14, 18, 22cm) having 5 step staircase. The results were as follows. 1. For the step height of 22cm the maximum. plantarflexion moment was the smallest and the largest for the step height of 14cm. 2. There was not a statistical difference shown for the extension moment of the knee joint for the different height of steps. 3. There was not a statistical difference shown for the flexion moment of the hip joint for the varying height of steps but on average for the 18cm step this increased rapidly. 4. The smallest maximum. value for inversion moment was revealed for the step height of 10cm and this increased significantly for the step height of 22cm. 5. The smallest maximum. value for abduction moment of the hip joint was revealed for the step height of 10cm and this increased significantly for the step height of 22cm. 6. There was no significant difference shown for the maximum. abduction moment for the hip joint. The main conclusion is that there is a huge difference in the moment of the lower extremities for the elderly while walking down a stairs with a step height above 18 cm and that this moment increased or decreased rapidly under a condition of step height being 22cm. With the results from this research and related research of elderly walking upstairs it can be shown that the step height has a large role in the safety for the elderly.

Experimental Study for the Capacity of Ordinary and Emergency Ventilation System in Deeply Underground Subway Station (대심도 지하역사 승강장 및 대합실 평상시/비상시 급·배기 풍량에 대한 실험적 연구)

  • Jang, Yong-Jun;Lee, Ho-Seok;Park, Duck-Shin
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.579-587
    • /
    • 2012
  • Shin-gumho station in Seoul underground subway have been selected to be experimentally investigated and analyzed for the real air supply & exhaust capacity compared to the original capacity of ordinary and emergency condition. The depth of Shin-gumho station is 43.6m which consists of the island-type platform ($8^{th}$ floor in underground) and a two-story lobby (first & second floor in underground). An emergency staircase connects between the platform and the lobby. Hot-wire anemometer, capture hood, wind vane & velocity meter and data acquisition systems are employed to perform the automatic measurement in this experiment. For ordinary case, air supply and exhaust capacity in the lobby were reduced by 34% and 46% compared to the original capacity, respectively. Air supply and exhaust capacity in the platform were reduced by 66% and 38%, respectively. For emergency case, air supply in the lobby was reduced by 42% and air exhaust in the platform was reduced by 28% compared to the original capacity. Therefore, air pollution in the station is expected to be worse in the ordinary environment and smoke control capability in the platform will be weakened in case of fire emergency.

Evaluation of Vibration and Structural Performance of an Innovative Sliding Step Steel Stair Using Full-Scale Mock-up Test (실물대 목업실험에 의한 슬라이딩스텝 철골계단의 진동 및 구조성능 평가)

  • Kim, Sung Yong;Lee, Cheol Ho;Kim, Na Eun;Cho, Sung Sang;Chung, Woon Ok
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.511-522
    • /
    • 2014
  • In this study, an innovative steel stair system is presented which enables rapid erection and high quality control in both residential and office building construction. This system features two lightweight steel stringers of box shape, bolted connections easy to absorb construction tolerance, and stair steps movable transversely (or sliding steps) such that the work space needed for concrete stairway wall could be easily provided. In this type of stairway system, other than providing robust connecting details, ensuring vibration performance is especially important since this system may be vibration-sensitive due to lightweight nature and/or probable low damping. To tackle these issues, a series of full-scale mock-up tests were conducted by using box-shape stringer members with or without concrete-fill. The connection system was shown to be sufficiently stiff and strong, or it remained elastic even under the 160% of service load level. Among the seven stringer alternatives, five exhibited satisfactory vibration performance according to the related North American and European acceptance criteria.

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.