• Title/Summary/Keyword: Stainless needle

Search Result 45, Processing Time 0.025 seconds

characteristic of breakdown voltage of electrode gap in vacuum (진공에서 극간 gap에 따른 절연파괴 전압 특성 파악)

  • Yoon, Jae-Hun;Kim, Byung-Chul;Lee, Sueng-Su;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.366-367
    • /
    • 2008
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of vacuum with air are studied in non-uniform field. The gap of needle to plane was 0.5mm, 0.8mm. The pressure of vacuum the range of 10^-4-10^-5torr. The diameter of a plane made of the stainless steel is150mm. As a result of the experiment, the breakdown voltage is increased about electrode gap distance increased. The electrode material influenced breakdown voltage in vacuum.

  • PDF

Development of needle guidance system and its evaluation for ultrasound-guided follicular aspiration (초음파유도 난포채란기의 개발과 이의 검증)

  • Choi, Min-cheol;Lee, Hyo-jong;Cho, Seong-keun;Kang, Tae-yung;Won, Hyun-hui
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.6
    • /
    • pp.1210-1217
    • /
    • 1999
  • This study was carried out to develop a newly designed ovum pick-up(OPU) instrument for ultrasound-guided transvaginal follicular aspiration in cows. This new instrument consists of out- & inner-layer stainless pipes and a grip with a trigger(hand) switch. Some gauge types of disposable needles and tubes can be attached to this inner pipe. With this instrument, while grasping an ovary with one hand, the other hand can handle in apiration and vacuum on/off with the least assitant's help. With this instrument the mean recovery rate of bovine follicular oocytes was 45.2%. In recovered oocytes, usable oocytes(Grade I & II) were 30.4% and this rate meant 1.4 oocytes per ovary. For 30 days after initial aspiration with this instrument, some adverse effects such as adhesion, hemorrhage, hematoma and other mass formation in/with ovaries were also examined by rectal examination, ultrasonographic and endoscopic images. Adhesion was found in one ovary 1 week after aspiration, and hemorrhagic lesion was found 1-2 days and petechia were found 3-5 days after aspiration and there was no remarkable adverse effects. It was found that this instrument could be applicable and safe for ovum pick-up in cows.

  • PDF

A study for biocompatibility of acupuncture's metal material - Focused on chemical composition and mechanical character - (침 금속재료에 대한 생체적합성 연구 - 화학적 조성 및 기계적 특성을 중심으로 -)

  • Baek, Yong-hyeon;Chung, In-tae;Lee, Sang-hun;Lee, Jae-dong;Choi, Do-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.4
    • /
    • pp.159-176
    • /
    • 2004
  • Objective : To present a criteria for acupuncture standardization, which will improve quality of acupuncture and secure safety, through studies of the biocompatibility of acupuncture. Methods : The acupunctures distributed in Korea were studied. The chemical composition, elasticity, and the solidity of the acupuncture's metal material was analyzed. Results & Conclusions : 1) The acupunctures distributed in Korea were all produced with ST304. Because acupuncture is used on a living body, the corrosion resistance, allergy proof and magnetism of the metal material should be considered. In this point, STS316 stainless steel would be more suitable than ST304. 2) The elasticity and solidity of the acupuncture's metal material distributed in Korea meet the medical instrument standards of the Korea Food and Drug Administration. But since the standards are only roughly outlined, the criteria should be realized and standardized.

  • PDF

Synthesis and Characterization of Fiberous AlN by Electrospinning (전기방사에 의한 섬유상 질화알루미늄 합성 및 특성 평가)

  • Chun, Seung-Yeop;Hwang, Jin-Ah;Chu, Jae-Uk;Chun, Myoung-Pyo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.7
    • /
    • pp.441-446
    • /
    • 2017
  • Aluminum nitride fibers were synthesized by carbothermal reduction and nitridation of precursor fibers obtained by electrospinning. The starting materials used to synthesize the AlN fibers were $Al(NO_3)_3{\cdot}9H_2O$ and urea. Polyvinylpyrrolidone with increasing viscidity was used as the carbon source to obtain a composite solution. The mixed solution was drawn into a plastic syringe with a stainless steel needle, which was used as the spinneret and connected to a 20 kV power supply. A high voltage was supplied to the solution to facilitate the formation of a dense net of fibers on the collector. The precursor fibers were dried at $100^{\circ}C$ and then heated to $1,400^{\circ}C$ for 1 h in a microwave furnace under $N_2$ gas flow for the carbothermal reduction and nitridation. X-ray diffraction studies indicated that the synthesized fibers consisted of the AlN phase. Field emission scanning electron microscopy studies indicated that the diameter of the calcined fibers was approximately 100 nm.

Reproduction of Traditionally-Refining Acupuncture Needle and Analysis of Surface-chemical Properties (전통 연침법(鍊鍼法)의 재현 및 침(鍼) 표면 변화의 분석)

  • Lee, Seung-Taek;Yu, Jeong-Ung;Kim, Ik-Jin;Cha, Wung-Seok
    • The Journal of Korean Medical History
    • /
    • v.26 no.2
    • /
    • pp.135-148
    • /
    • 2013
  • This study analyzed surface-chemical transitions in manufacturing process of traditional acupuncture as proposed method by Dongeuibogam. The manufacturing process of traditional acupuncture from a used iron for a long time was divided by primary medicinal herbs treatment, secondary medicinal herbs treatment and tertiary treatment using by dog meat. The traditional acupuncture research process was measured according to the characteristics and changes of the specimens at each processing step of the manufacturing process. The following devices were used to Surface analysis. Scanning electron microscopy (SEM), Energy Dispersive Spectrometer (EDS), X-ray diffraction analyzer (XRD). As a result, medicinal herbs removed impurities on the surface and raised the antibacterial effect in the manufacturing process of traditional acupuncture. Furthermore, the ingredients of medicinal herbs were coated on the surface of the iron. Dog meat influenced to prevent surface corrosion, reduce friction when the acupuncture was inserted. Although the process empirically obtained, a glimpse of the wisdom of our ancestors was revealed. These ancestral wisdom can be expected to apply today, when used in manufacturing process of a modern stainless steel acupuncture to compensate for the defective part.

Development of Perforating Die for Manufacturing Fine Multi-perforated type Nail Files (미세 다수공 타입의 네일파일 제조용 퍼퍼레이팅 금형 개발)

  • Kim Sei-Hwan
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.42-46
    • /
    • 2004
  • 0.5mm thick steel is used to manufacture nail files. The first process is blanking the blank and then make about 300 holes of 0.8$\~$1.0mm in diameter. This process depends mainly on etching which takes $33\%$ of manufacturing cost and it can make manufacturing cost rise. The residual etching reagent is not environmentally friendly and the steel material is apt to rust as well. The key accomplishments of this research are to change the material from steel to stainless and develop a progressive perforating die in place of etching process.

  • PDF

Role of the Vestibular and Medullary Reticular Neuclei for the Motor Evoked Potentials in Rats (흰쥐의 운동유발전위에 대한 전정신경핵과 연수망상핵의 역할)

  • Lee, Moon-Young;Lee, Sung-Ho;Kim, Jae-Hyo;Park, Byung-Rim;Kim, Min-Sun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.6
    • /
    • pp.603-611
    • /
    • 1997
  • The motor evoked potentials (MEPs) have been advocated as a method of monitoring the integrity of spinal efferent pathways in various injury models of the central nervous system. However, there were many disputes about origin sites of MEPs generated by transcranial electrical stimulation. The purpose of present study was to investigate the effect of major extrapyramidal motor nuclei such as lateral vestibular nucleus (VN) and medullary reticular nucleus (mRTN) on any components of the MEPs in adult Sprague-Dalwey rats. MEPs were evoked by electrical stimulation of the right sensorimotor cortex through a stainless steel screw with 0.5mm in diameter, and recorded epidurally at T9 - T10 spinal cord levels by using a pair of teflon-coated stainless steel wire electrodes with 1mm exposed tip. In order to inject lidocaine and make a lesion, insulated long dental needle with noninsulated tips were placed stareotoxically in VN and mRTN. Lidocaine of $2{\sim}3\;{\mu}l$ was injected into either VN or mRTN. The normal MEPs were composed of typical four reproducible waves; P1, P2, P3, P4. The first wave (P1) was shown at a mean latency of 1.2 ms, corresponding to a conduction velocity of 67.5 m/sec. The latencies of MEPs were shortened and the amplitudes were increased as stimulus intensity was increased. The amplitudes of P1 and P2 were more decreased among 4 waves of MEPs after lidocaine microinjection into mRTN. Especially, the amplitude of P1 was decreased by 50% after lidocaine microinjection into bilateral mRTN. On the other hand, lidocaine microinjection into VN reduced the amplitudes of P3 and P4 than other MEP waves. However, the latencies of MEPs were not changed by lidocaine microinjection into either VN or mRTN. These results suggest that the vestibular and reticular nuclei contribute to partially different role in generation of MEPs elicited by transcranial electrical stimulation.

  • PDF

Microstructural Changes during Tempering Treatment of Nitrogen-permeated STS 410 and 410L Martensitic Stainless Steels (질소침투 열처리한 STS 410 및 410L 마르텐사이트계 스테인리스강의 템퍼링에 의한 조직변화)

  • Lee, Hea Joeng;Kong, Jung Hyun;Lee, Hae Woo;Yu, Dea Kyung;Kang, Chang Yong;Sung, Jang Hyun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.20 no.2
    • /
    • pp.84-93
    • /
    • 2007
  • Microstructural changes during tempering at the temperature range of $300^{\circ}C{\sim}700^{\circ}C$ for the nitrogen-permeated STS 410 and 410L martensitic stainless steels has been investigated. After nitrogen permeation at temperature between 1050 and $1150^{\circ}C$, the surface layer appeared fine $Cr_2N$ of square and rod types in the martensite matrices. Hardness of the nitrogen-permeated surface layer represented 680Hv and 625Hv, respectively, for 410 and 410L steels. It is considered that the fine homogeneously dispersive effect of precipitates by nitrogen caused the increased hardness. Due to the counter current effect of carbon from interior to surface during nitrogen diffusion from surface to interior, the 0.1%C alloyed 410 steel showed the low nitrogen content of 0.025% compared with 0.045% of 410L steel at the distance of $100{\mu}m$ from the surface. Tempering of nitrogen-alloyed 410 and 410L showed the maximum hardness at $450^{\circ}C$. This maximum hardness was considered to be the secondary hardening effect of very fine carbide and nitride. The decrease in hardness at $700^{\circ}C$ was the softening effect of the matrix due to the precipitation of many needle-shaped $Cr_2N$ for 410 steel and the precipitation of coarse nitride of $Cr_2N$ in line with the spherical precipitates with directionality for 410L steel. For 410 steel, the corrosion resistance of nitrogen permeated surface in the solution of 1 N $H_2SO_4$ were nearly unchanged, however the superior corrosion resistance was obtained for nitrogen permeated 410L steel compared to the solution annealed condition.

Effect of Al Content Variation on High Temperature Gas Nitriding in 13%Cr-0.16%C Stainless Steel (13%Cr-0.17%C 스테인리스강의 고온 가스질화에 미치는 Al 함량 변화의 영향)

  • Park, B.T.;Kim, J.M.;Kang, H.J.;Kong, J.H.;Kang, C.Y.;Sung, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.24 no.6
    • /
    • pp.318-326
    • /
    • 2011
  • This study has been performed to investigate the effect of Al addition on High Temperature Gas Nitriding (HTGN) in 13%Cr-0.16%C stainless steel with different Al contents of 0.54%, 1.76% and 2.36%, respectively. HTGN treatment was carried out at $1100^{\circ}C$ for 1 hr, 5 hrs and 10 hrs. Nitrogen-permeated surface layers showed round type carbides of $Cr_{23}C_6$ and needle type nitrides of AlN in the matrix of martensite, representing 600~700 Hv. And the thickness of the surface layer increased with increasing Al content and HTGN treatment time. The inner region that was not permeated nitrogen showed chromium carbides in the mixed phase of martensite and ferrite for the 0.53% Al alloyed steel, however chromium carbides in the matrix of ferrite single phase were shown for the steels with the addition of 1.76%Al and 2.36%Al, representing the hardness of ~200 Hv. During nitrogen permeation from surface to the interior, substitutional elements of Cr, Al and Si moved toward the surface and interstitial element of carbon also moved from interior to the surface. This movement of alloying elements leads high concentration of these elements at the outmost surface, subsequently the lowest peak of substitutional elements were shown in the vicinity of near surface. After showing the lowest peak, the high concentration region of Al and C were formed due to the continuous movement of Al toward the surface. The long discontinuous precipitates of $Cr_{23}C_6$ and AlN were formed along the outmost surface owing to the high concentration of these alloying elements.

Transcutaneous electrical nerve stimulation, acupuncture, and spinal cord stimulation on neuropathic, inflammatory and, non-inflammatory pain in rat models

  • Sato, Karina Laurenti;Sanada, Luciana Sayuri;da Silva, Morgana Duarte;Okubo, Rodrigo;Sluka, Kathleen A.
    • The Korean Journal of Pain
    • /
    • v.33 no.2
    • /
    • pp.121-130
    • /
    • 2020
  • Background: Transcutaneous electrical nerve stimulation (TENS), manual acupuncture (MA), and spinal cord stimulation (SCS) are used to treat a variety of pain conditions. These non-pharmacological treatments are often thought to work through similar mechanisms, and thus should have similar effects for different types of pain. However, it is unclear if each of these treatments work equally well on each type of pain condition. The purpose of this study was to compared the effects of TENS, MA, and SCS on neuropathic, inflammatory, and non-inflammatory pain models. Methods: TENS 60 Hz, 200 ㎲, 90% motor threshold (MT), SCS was applied at 60 Hz, an intensity of 90% MT, and a 0.25 ms pulse width. MA was performed by inserting a stainless-steel needle to a depth of about 4-5 mm at the Sanyinjiao (SP6) and Zusanli (ST36) acupoints on a spared nerve injury (SNI), knee joint inflammation (3% carrageenan), and non-inflammatory muscle pain (intramuscular pH 4.0 injections) in rats. Mechanical withdrawal thresholds of the paw, muscle, and/or joint were assessed before and after induction of the pain model, and daily before and after treatment. Results: The reduced withdrawal thresholds were significantly reversed by application of either TENS or SCS (P < 0.05). MA, on the other hand, increased the withdrawal threshold in animals with SNI and joint inflammation, but not chronic muscle pain. Conclusions: TENS and SCS produce similar effects in neuropathic, inflammatory and non-inflammatory muscle pain models while MA is only effective in inflammatory and neuropathic pain models.