• Title/Summary/Keyword: Stage efficiency

Search Result 2,425, Processing Time 0.031 seconds

Relationship of Spikelet Number with Nitrogen Content, Biomass, and Nonstructural Carbohydrate Accumulation During Reproductive Stage of Rice (벼의 영화수와 생식 생장기 경엽중, 질소함량 및 비구조 탄수화물함량과의 관계)

  • 이변우;박동하;최일선
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.6
    • /
    • pp.486-491
    • /
    • 2002
  • Spikelet number and its components of rice plant are closely associated with nitrogen accumulation and biomass production during panicle formation stage. To elucidate this relationship and also compare the differences of the sink formation efficiency among cultivars, spikelet number, its components, nitrogen content, nonstructural carbohydrate content, and plant dry matter were investigated under 5 nitrogen levels with two split application methods and shading treatments by using three rice varieties. The nitrogen amount in shoot at panicle initiation stage and at 15 days after panicle initiation showed significant positive correlation with primary rachis branches per square meter, and that at 15 days after panicle initiation and at heading stage with secondary rachis branches per square meter, Primary and secondary rachis branches per square meter showed positive significant correlation with the shoot dry weight at panicle initiation stage and at 15 days after panicle initiation stage, respectively, The amount of degenerated secondary rachis branches and spikelets per square meter showed significant negative correlation with the dry weight and nonstructural carbohydrate increase of stem during 15days after panicle initiation, and the contents of nonstructural carbohydrate at 15 days after panicle initiation. Spikelets per unit area showed significant positive correlation with nitrogen amount in shoot and shoot dry weight at heading stage. The sink formation efficiency expressed as the spikelet number produced by the unit amount of nitrogen in shoot at heading stage was higher in Nampoongbyeo than Choocheongbyeo and Hwaseongbyeo. Sink formation efficiency was negatively correlated with the dry weight increase of shoot and stem during reproductive stage. but not significantly with that of leaf in all varieties. Sink formation efficiency was not significantly correlated with nonstructural carbohydrate, but was significantly negatively correlated with structural carbohydrate increase during reproductive stage.

A study on the Simultaneous Removal of Nitrogen and Phosphorus on Reactor Configuration in Intermittently Aerated Activated Sludge System (간헐폭기 활성슬러지 시스템에서 반응조 형태에 따른 질소 및 인의 동시제거 특성에 관한 연구)

  • Lee, Won-Ho;Seo, In-Seok;Kim, Kwang-Yul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.106-114
    • /
    • 1998
  • In this research, single-, two- and four-stage intermittently aerated activated sludge system were investigated for simultaneous removal of nitrogen and phosphorus with swine wastewater. For the comparison of removal efficiency, conventional activated sludge system was operated. Operational conditions of intermittently aerated activated sludge system were SRT 20day, HRT 24hr and aeration/nonaeration time 1hr/1hr, respectively. Nitrogen and phosphorus removal efficiency in Intermittently aerated activated sludge system was upgraded compare with conventional activated sludge system. In single-stage intermittently aerated activated sludge system, release-uptake of $PO_4^{3-}-P$ was observed very well but, phosphosrus removal in effluent was not effective. In single-stage intermittently aerated activated sludge system, release-uptake of $PO_4^{3-}-P$ in first reactor, was observed very well but, in following reactor, $PO_4^{3-}-P$ concentation showed almost no change. T-N removal efficiency in conventional activated sludge system, single-, two-, and four-stage intermittently aerated activated sludge system were 48, 87, 90.9 and 95.5%, respectively, and phosphorus removal efficiency were 48, 75, 97 and 95%, respectively. Intermittently aerated activated sludge system as a alternative processes of conventional system leads to meet satisfactory effleunt with only on/off aeration regulation and save energy for aeration.

  • PDF

Effects of Loading-Unloading Environments on the Efficiency of Freight Railroad Stations : An Empirical Investigation (적하작업환경이 철도화물취급역의 효율성에 미치는 영향)

  • Kim, Seong-Ho
    • Korean Management Science Review
    • /
    • v.27 no.2
    • /
    • pp.45-54
    • /
    • 2010
  • In this paper we analyze the effects of loading-unloading environments on the efficiency of freight railroad stations using a two-stage procedure for efficiency model estimation. And from the results we explore a way for efficiency improvement of freight railroad stations. Two-stage procedure is composed of data envelopment analysis and regression analysis. The results show that we could expect efficiency improvement through the government"s effort to make railway stations to be strategic position. Furthermore, they advocate policy-makers that efficiency can be improved by simplifying the kinds of freight items and increasing the scale.

A Study on the Efficiency of a Two Stage Shrinkage Testimator for the Mean of an Exponential Distribution

  • Myung-Sang Moon
    • Communications for Statistical Applications and Methods
    • /
    • v.5 no.1
    • /
    • pp.231-238
    • /
    • 1998
  • A two stage shrinkage testimator for the mean of an exponential distribution is considered with the assumption that an initial estimate of the mean is available. Mean squared error(MSE) of testimator and its relative efficiency (to usual single sample mean) are briefly reviewed. It is shown that relative efficiency depends only on the ratio of true mean value and its initial estimate.

  • PDF

Numerical Predictions of Roughness Effects on the Performance Degradation of an Axial-Turbine Stage

  • Kang Young-Seok;Yoo Jae-Chun;Kang Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.1077-1088
    • /
    • 2006
  • This paper describes a numerical investigation on the performance deteriorations of a low speed, single-stage axial turbine due to use of rough blades. Numerical calculations have been carried out with a commercial CFD code, CFX-Tascflow, by using a modified wall function to implement rough surfaces on the stator vane and rotor blade. To assess the stage performance variations corresponding to 5 equivalent sand-grain roughness heights from a transition ally rough regime to a fully rough regime, stage work coefficient and total to static efficiency were chosen. Numerical results showed that both work coefficient and stage efficiency reduced as roughness height increased. Higher surface roughness induced higher blade loading both on the stator and rotor which in turn resulted in higher deviation angles and corresponding work coefficient reductions. Although, deviation angle changes were small, a simple sensitivity analysis suggested that their contributions on work coefficient reductions were substantial. Higher profile loss coefficients were predicted by higher roughness heights, especially on the suction surface of the stator and rotor. Furthermore sensitivity analysis similar to the above, suggested that additional profile loss generations due to roughness were accountable for efficiency reductions.

Effect of displacement volume ratio on compressor performance for a twin rotary compressor (트윈 로타리 압축기의 행정 체적비가 압축기 성능에 미치는 영향)

  • Ahn, Jong-Min;Kim, Hyun-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.171-176
    • /
    • 2008
  • As one way of design optimization of two-stage two-cylinder rotary compressor used for R410A heat pump application, displacement volume ratio, being defined by the ratio of the second stage cylinder volume to that of the first stage, has been varied and its effect on the compressor performance has been investigated by a computer simulation program. For simplicity, only the cylinder height of the second stage was varied to change the volume ratio. With increasing the volume ratio in the range of VR=$0.55{\sim}0.9$, volumetric efficiency increased monotonically, but adiabatic efficiency showed a maximum at around VR=0.6. Mechanical efficiency was little influenced by the volumetric ratio. As a consequence, maximum improvement of the compressor performance was found at around VR=0.7. Compared to a one-stage two-cylinder rotary compressor with about the same cooling capacity, COP improvement was about 6.96%.

  • PDF

Assessment for Efficiency of Two-Stage Randomized Response Technique

  • Park, Kyung-Ho
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.2
    • /
    • pp.427-433
    • /
    • 2000
  • In this paper, we review several two-stage randomized response techniques for gathering self-report data when persons are asked sensitive question. Also efficiencies and privacy protections based on the two-stage randomized response procedures are compared. Finally, we find optimal parameter conditions.

  • PDF

A Study on Management Efficiency for the Environmentally-Friendly Agricultural Product of Oilseed Crop - Focused on Sesame and Perilla - (친환경인증 유지작물의 인증유형별 경영효율성 분석 - 참깨·들깨를 중심으로 -)

  • Kim, Min-Ju;Park, Joo-Sub
    • Korean Journal of Organic Agriculture
    • /
    • v.23 no.2
    • /
    • pp.207-231
    • /
    • 2015
  • This study evaluate examines the efficiency and the improvement measurement of Oilseed crops (Sesame and Perilla). For this purpose, In the first stage, this study analyzes the current conditions of oilseed industry. In the second stage, this study evaluates the efficiency and super-efficiency of environmentally-friendly agricultural product producers. The result of this study show that: (1) Changes in annual wholesale price of Sesame and Perilla; (2) An efficiency and ranking of environmentally-friendly product producers; (3) The solutions and improvement measurements for inefficient producers.

A Study on Flow Characteristics of Vertical Multi-stage Centrifugal Pump by CFD (CFD에 의한 입형 다단 원심펌프 유동특성에 관한 연구)

  • MO, Jang-Oh;NAM, Koo-Man;KIM, You-taek;LEE, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.402-407
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pimp including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26\;m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is to confirm how much the effect of blade inlet angle of guide vane has an influence on the performance of vertical multi-stage centrifugal pimp. these results performed by $20^{\circ},\;30^{\circ}$ inlet angle of guide vane are compared with grundfos performance data. The vertical multi-stage pump consist of the impeller, guide vane, and cylinder. The characteristics such as total pressure coefficient total heat shaft horse power, power efficiency, discharge coefficient are represented according to flow rate changing.

  • PDF

Computational Efficiency of Resamplers in Multi-Stage Structure (재표본화에서 다단계 구현의 계산 효율성)

  • Kim Rin-Chul
    • Journal of Broadcast Engineering
    • /
    • v.11 no.1 s.30
    • /
    • pp.138-141
    • /
    • 2006
  • This paper evaluates the computational efficiency of sample-rate converters with rational factors in multi-stage structure in terms of memory requirement and multiplications per second. We describe resolution preserving and mutual prime conditions, and then present a method for designing the converter from which optimal rational-valued conversion factors for each stage can be yielded directly. As an example, we show an implementation of the 44.1-to-48KHz sample-rate converter in 2-stage structure.