• Title/Summary/Keyword: Stage efficiency

Search Result 2,425, Processing Time 0.027 seconds

Organophosphorus Insecticide Residues in Fruits and Vegetables (과실 채소중 잔류농약(유기인제)에 관한 연구)

  • 윤숙자
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.1
    • /
    • pp.83-92
    • /
    • 1990
  • Adapting two step aeration system to a waste water treatment of W-paper manufactory as Full-Scale Plants, we drew a following conclusion from its practical working. 1. Because BOD removal efficiency was 20% in A-Stage, 90% in B-Stage and total removal efficiency was 97%. It worked treatment plant well and was suitable for effluent water standard as well. Because COD removal efficiency was 42% in A-stage, 71% in B-stage and the total removal efficiency was 94% COD control was possible in effluent water quality. 2. Treatment efficiency according to a load capacity was average 20% in 1.401 BOD kg/m3/d load of A-Stage and average 90% in 0.273 BOD kg/$\textrm {m}^3$ / d load of B-Stage. 3. Treatment efficiency according to a ratio of F/M was 2.657--5.024 kg BOD/kg MLSS/d in A-Stage and BOD removal efficiency was 16-261 in the same stage. The ratio of F/M was 0.068-0.094 kg BOD /kg MLSS/d and BOD removal efficiency ratio was 85-94%. Therefore treatment efficiency could be kept stably and volume of aeration tank could be reduced wholly. 4. Treatment efficiency according to MLSS appeared BOD 20%. COD 42%, in A-Stage and removal efficiency appeared BOD 90%, COD 71% in B-Stage. They were suitable for plan condition. 5. Because of working of complemented treatment plant by AB-Process. 20,000,000 Won a month was saved than the ordinary working cost. Therefore, it was assumed that invested cost could be recollected in 19 months or so consequently.

  • PDF

Wireless Energy Transmission High-Efficiency DC-AC Converter Using High-Gain High-Efficiency Two-Stage Class-E Power Amplifier

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.3
    • /
    • pp.161-165
    • /
    • 2011
  • In this paper, a high-efficiency DC-AC converter is used for wireless energy transmission. The DC-AC convertter is implemented by combining the oscillator and power amplifier. Given that the conversion efficiency of a DC-AC converter is strongly affected by the efficiency of the power amplifier, a high-efficiency power amplifier is implemented using a class-E amplifier structure. Also, because of the low output power of the oscillator connected to the input stage of the power amplifier, a high-gain two-stage power amplifier using a drive amplifier is used to realize a high-output power DC-AC converter. The high-efficiency DC-AC converter is realized by connecting the oscillator to the input stage of the high-gain high-efficiency two-stage class-E power amplifier. The output power and the conversion efficiency of the DC-AC converter are 40.83 dBm and 87.32 %, respectively, at an operation frequency of 13.56 MHz.

The slope effect of grade efficiency curve in a two-stage cyclone (등급집진효율 곡선의 기울기가 2단 사이클론의 집진효율에 미치는 영향)

  • Heo, Kwang-Su;Seol, Seoung-Yun;Kim, Min-Ha
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1963-1968
    • /
    • 2004
  • A collection efficiency of cyclone is influenced by cut-size and slope of grade efficiency curve. It has been recognized that the collection efficiency is improved when the cut-size is reduced. However, effects of the slope have never been studied so far. In this study, we analyze a relationship between slope of grade efficiency and collection efficiency in two-stage cyclones. In single stage cyclones, higher slope cyclones have high efficiency. On the contrary to single stage cyclone, collection efficiency of two-stage cyclone have the maximum value when the first cyclone has a lower slope and second cyclone is high.

  • PDF

Optimal Efficiency Operation of 2-Stage Boost Converter With Weighted Efficiency (가중효율을 적용한 2-Stage Boost 컨버터 최적효율 운전 연구)

  • Kim, Seung-Min;Kim, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.285-293
    • /
    • 2021
  • An optimal operation method based on weighted efficiency for a two-stage boost converter is proposed in this study. Detailed loss analysis of the converter is performed to derive the optimal operation method according to the load and input voltage fluctuations, and the optimal DC-bus voltage is derived by applying the weighted efficiency method. The proposed method can satisfy optimal efficiency in the main operation region without a complicated control method. Using 1kW typical two-stage boost converter and is verified three types of weighted efficiency formulas and loss analysis are utilized to derive high-efficiency optimal DC-bus voltage from each load range.

Biological Treatment of Textile Wastewater by Anaerobic-Aerobic Reactor System (Pilot 혐기-호기 공정을 이용한 염색폐수의 생물학적 처리)

  • 박영식;안갑환
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.11-20
    • /
    • 2001
  • An anaerobic sludge-aerobic fixed-bed biofilm(packed with ceramic support carrier of 1 inch size) reactor system was built up to treat textile wastewater. The efficiency of reactor system was examined by determining the effects of textile wastewater ratio(from 25% to 100% at HRT 24 h). The influent range of SCOD concentration and color were 1,036~1,357 mg/L, and 1,487~1,853 degree, respectively. When textile wastewater ratio was 100% and hydraulic retention time was 24 hours, SCOD removal efficiency by the anaerobic stage were 39.2% 100% and hydraulic retention time was 24 hours, SCOD removal efficiency by the anaerobic stage were 39.2% and the removal efficiency of the whole system were 75.8%. Color removal efficiency by the anaerobic stage were 45.4%(soluble color), and the removal efficiency of the whole system were 70.2%. In the A/A reactor system, the aerobic stage played an important role in removing both color and COD as well as anaerobic stage.

  • PDF

Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles (다단 임팩터(MOUDI)의 조대 입자 채취 특성)

  • 배귀남;지준호;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.799-804
    • /
    • 1999
  • Particle collection characteristics of the MOUDI cascade impactor has been studied for coarse particles in the range of 2 to 20$mu extrm{m}$ in aerodynamic diameter. A vibrating orifice aerosol generator was empolyed to generate monodisperse test aerosols. The oleic acid and sodium chloride(NaCl) particles were used as test aerosols. Aluminum foil and Teflon filter were selected as impaction media. The sampling flow rate was changed from 25 to 35L/min. Particle collection efficiency for single stage was examined for liquid particles. The stage response was obtained experimentally for the cascade impactor composed of three stages and a backup filter. The results showed that most of particle collection efficiencies measured in this work are similar to the efficiency curves obtained by Marple et al.(1991). For particles less than cut-off size of the stage, the collection efficiencies of solid particles are similar to those of loquid particles. However, the collection efficiency of solid particles decreases with mereasing particle diameter for the particles greater than the actual cut-off size of the impactor. The particle collection efficiency increases with increasing sampling flow rate at the same particel size. However, the collection efficiency curves seem not to be greatly shifted with the flow rate. The stage responses obtained by direct measurements in this work are in good agreement with those derived from the collection efficiency curves for single stage.

  • PDF

Removal Characteristics of Hazard Organic Substances in the Multi-stage Ozone Contactor (다단오존접촉조에서 유해화학물질의 제거특성)

  • 박영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.41-49
    • /
    • 1999
  • The water treatment by was performed to remove VOC and organic substances in the multi-stage ozone contactor. Ozone is mainly utilized to change the chemical structures of organic substance, of which finally has the purpose to degrad them. The removal efficiency of VOC has 20~60% at the ozone concentration of 3 ppm, in case of trichloroethylene, its efficiency is reduced by 85% at the ozone contact time of 8 min. Design factors such as the number of stage, ozone concentration, zone contact time are determined for optimal treatment in the multi-stage contactor.

  • PDF

Performance Analysis of a Carbon Dioxide(R744) Two-Stage Compression and One-Stage Expansion Refrigeration Cycle ($CO_2$용 2단압축 1단팽창 냉동 사이클의 성능 분석)

  • Roh, G.S.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.70-75
    • /
    • 2009
  • In this paper, cycle performance analysis of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature in the carbon dioxide two-stage refrigeration cycle. The main results were summarized as follows : The cooling capacity of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, compressor efficiency and gas cooling pressure, but decreases with the increasing mass flowrate ratio and evaporating temperature. The compression work of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, outlet temperature of gas cooler, gas cooling pressure and evaporating temperature, but decreases with the increasing compressor efficiency and mass flowrate ratio. The COP of two-stage compression and one-stage expansion refrigeration system increases with the increasing compressor efficiency, but decreases with the increasing superheating degree, gas cooling pressure, mass flowrate ratio and evaporating temperature. Therefore, superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system have an effect on the cooling capacity, compressor work and COP of this system.

  • PDF

Effects of Two Stage Vortex Finder on the Particulate Collection Efficiency of Cyclone Separator (2단 선회류 약화기가 원심력집진기의 집진효율에 미치는 영향)

  • 강순국;유경선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.633-640
    • /
    • 2000
  • The effects of structure modification of the vortex finder on the collection efficiency and pressure drop have been investigated. The pressure drop in a cyclone having the two stage vortex finder is higher than that in a conventional cyclone and increases proportionally with the increase of square of gas inlet velocity in both cases. The pressure drop of both conventional cyclone of friction resistance at the boundary layer. The collection efficiency of fine dust has been enhanced by addition of vortex finder in a conventional cyclone and gas inlet velocity showing maximum dust removal efficiency increase to 17 m/s(1.7 times of saltation velocity). Optimum size of two stage vortex finder has been induced to 13 cm I.D$\times$2.6cm Length from the results of overall dust collection efficiency. Previous models were tested for the simulation of collection efficiency of cyclone having two stage vortex finder and the Dietz model predict the similar value with experimental results of the present study.

  • PDF

Influence of slot width on the performance of multi-stage overtopping wave energy converters

  • Jungrungruengtaworn, Sirirat;Hyun, Beom-Soo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.6
    • /
    • pp.668-676
    • /
    • 2017
  • A two-dimensional numerical investigation is performed to study the influence of slot width of multi-stage stationary floating overtopping wave energy devices on overtopping flow rate and performance. The hydraulic efficiency based on captured crest energy of different device layouts is compared with that of single-stage device to determine the effect of the geometrical design. The results show optimal trends giving a huge increase in overtopping energy. Plots of efficiency versus the relative slot width show that, for multi-stage devices, the greatest hydraulic efficiency is achieved at an intermediate value of the variable within the parametric range considered, relative slot width of 0.15 and 0.2 depending on design layouts. Moreover, an application of adaptive slot width of multi-stage device is investigated. The numerical results show that the overall hydraulic efficiency of non-adaptive and adaptive slot devices are approximately on par. The effect of adaptive slot width on performance can be negligible.