• Title/Summary/Keyword: Stage Lighting Design

Search Result 65, Processing Time 0.027 seconds

A Development of Theatre Art Major Course based on Case Studies of Media Technology-converged Performances (미디어기술 융합공연 사례분석을 통한 무대미술 전공 교과목 연구)

  • Park, Jin-Won;Kim, Ga-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.5
    • /
    • pp.562-571
    • /
    • 2019
  • The expansion of the performing arts market to include new genres of art that combine art and cutting-edge media technology has surpassed the limitations of traditional theatre art elements such as stage, costumes, lighting, sound, and props, allowing free expression of space-time and visual art. It is growing into a wide area with unlimited potential in the performing arts sector. In response to these changes and the demands of the time, there is an increasing demand for multi-talents who can plan and produce arts and technology-converged contents that will contribute to the development of the performing arts industry. As a result, university departments related to theatre art across the country feel that it is urgent to develop curricula that will enhance students' competency by incorporating the latest media technologies such as virtual reality, holography, and interactive motion sensors into the existing performance art visualization process. In this study, the author will examine the process of developing courses in technology-incorporated theatre art (design) through case studies of media technology-converged performances from the past 10 years. Based on the traditional concept of theatre art, the attempt to fuse stage art with media technology will be a cornerstone of attempts to foster a group of talented artists who transcend the limits of creative visual expression and creative value.

The Analysis of Screen Composition Method in 19th Presidential Candidate TV Debates (제19대 대통령후보 TV토론회 화면구성방법 분석)

  • Jang, Byung Min;Hwang, Dong Hyun;Choi, Seong Jhin
    • Journal of Broadcast Engineering
    • /
    • v.25 no.1
    • /
    • pp.67-82
    • /
    • 2020
  • This study is based on the screen composition(shot size, split screen, candidate placement, lighting, stage) that fits the discussion process (round table, sitting, standing method) adopted from the 19th presidential candidates' TV joint discussion to analyze the adequacy and limitations of the methodology(design, candidate background, etc.). In addition, the progress and screen composition of the 45th US Presidential Candidates Debate in 2016 and the 25th Presidential Candidates of France TV Joint Debate in 2017 have been analyzed to compare and contrast the methods used in Korea. Through this, we apply the screening method to the 20th Presidential Candidate TV Joint Debate, which will be held in 2022, to fit the fixed discussion process that can fully identify candidates' qualities, policies, and vision.

A Study on the Comparison of Building Data Using 3D Scanning (3D 스캐닝 활용 건축물 데이터 비교에 관한 연구)

  • Hwang, Byeong Yeon;Park, Jong Ki;Lee, Tae Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.50-56
    • /
    • 2021
  • This study examines 3D scanning and how it is used in the construction field. 3D scanning technology was applied to a real space and compared with drawings in the planning and construction stages. 3D scanning technology has been widely applied in the field of construction, design, construction, and safety. The results of comparing 3D scanning data with drawings are as follows. First, the external shape and dimensions do not show much difference. Second, the internal shape and dimensions are different. Third, indoor lighting layouts are different in all buildings. 3D scanning should be an essential element in the construction stage before completion and should be used for supervision tasks such as material management, improving the efficiency of construction, and safety management through continuous 3D scanning using automation and robots. Follow-up studies in the field of architecture, such as BIM and process management, will be needed.

Effects of four dim vs high intensity red color light regimens on growth performance and welfare of broilers

  • Senaratna, D.;Samarakone, T.S.;Gunawardena, W.W.D.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.1
    • /
    • pp.149-156
    • /
    • 2018
  • Objective: Broilers show clear preference towards red color light (RL). However setting of an optimum light intensity is difficult since dim intensities that favor growth reduce welfare. This experiment was conducted to test the most effective RL intensity regimen (Dim [5 lux; DI] vs high [320 lux; HI]) in combination applied at different growth stages that favors for both performance and welfare. Methods: Complete randomize design was adopted with 6 replicates. Treatments were; T1 = early DI (8-21 d)+latter HI (22-35 d); T2 = early DI (8-28 d)+latter HI (29-35 d), T3 = early HI (8-21 d)+latter DI (22-35 d), T4 = early HI (8-28 d)+latter DI (29-35 d) and T5 = control (white light; WT) (8-35 d) at medium intensity (20 lux). Body weight (BW), weight gain (WG), water/feed intake and ratio, feed conversion ratios (FCR) were assessed. Common behaviours (15) were recorded by scan sampling method. Lameness, foot pad dermatitis, breast blisters, hock burning damage were assessed as welfare parameters. Fear reactions were tested using Tonic Immobility Test. Ocular and carcass evaluations were done. Meat and tibiae were analyzed for fat and bone ash respectively. Results: On 35 d, the highest BW ($2,155.72{\pm}176g$), WG ($1,967.78{\pm}174g$) were recorded by T2 compared to WT ($BW_{WT}=1,878.22{\pm}155$, $WG_{WT}=1,691.83{\pm}160$). But, application of RL, either DI, or HI during early/latter stage had no significant effect on FCR. Under HI, birds showed much higher active behaviours. DI encourages eating. Though LI changed from DI to HI, same trend could be seen even under HI. The highest leg strength ($218.5{\pm}120s$) was recorded by T2. The lowest leg strength ($64.58{\pm}33s$) and the highest ocular weight ($2.48{\pm}1g$) were recorded by T1. Significantly (p<0.05) the highest skin weight ($162.17{\pm}6g$) but the lowest fat% in meat ($13.03%{\pm}5%$) was recorded by T2. Conclusion: Early exposure to DI-RL up to 28 days followed by exposure to HI-RL is the most favorable lighting regimen for optimizing production, better welfare of broilers and improving health benefits of meat.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.