• 제목/요약/키워드: Stack-Fin

검색결과 5건 처리시간 0.017초

히트파이프 및 스택핀을 이용한 50W급 옥외용 LED 모듈개발 (Development of Outdoor 50W-LED Module using Heat-pipe and Stack-fin)

  • 홍석기;정희석;염정덕
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.15-21
    • /
    • 2015
  • We proposed 50W-LED modules of using Heat-pipe and Stack-fin and produced LED modules was evaluated heat dissipation characteristics with comparison of the conventional die-casting type. It verified the application of products by applying it to 150W-LED road luminaires through simulation. The LED module was measures aimed design temperature of the Stack-fin and showed 26% upward heat dissipation effect than a conventional die-casting type. The luminous efficacy of 150W-LED road luminaires using this LED module reached over 112lm/W, and the simulation results showed average of horizontal luminance, overall luminance uniformity($U_O$) and lane luminance uniformity($U_I$) that is suitable for five-lane road with the KS standards.

적층형 EGR Cooler의 Pitch 길이 변화가 열교환 특성에 미치는 영향 (Effects of Pitch Length of Stack-type EGR Cooler on Heat Exchange Characteristics in a Diesel Engine)

  • 황세준;김민철;장상훈;김형만
    • 한국자동차공학회논문집
    • /
    • 제18권2호
    • /
    • pp.135-140
    • /
    • 2010
  • An important goal in diesel engine research is the development of a means to reduce the emissions of nitrogen oxides (NOX). The use of a cooled exhaust gas recirculation (EGR) system is one of the most effective techniques currently available for reducing nitrogen oxides. Since Particular Matter (PM) fouling reduces the efficiency of an EGR cooler, a trade-off exists between the amount of NOX and PM emissions, especially at high engine loads. In the present study, engine dynamometer experiments have been performed to investigate the heat exchange characteristics of the stack-type EGR coolers with wave fin pitches of 3.6 and 4.6 mm. The results show that the heat exchange effectiveness is decreased as surface area decrease with pitch of 4.6 mm due to PM fouling. As surface area increase at pitch of 3.6 mm, super-cooling happens in the recirculated exhaust gas.

인증 정보 관리를 위한 기술 동향과 AIM 프레임워크 연구 및 설계 (Technology Trends, Research and Design of AIM Framework for Authentication Information Management)

  • 김현중;차병래;반성범
    • 디지털융복합연구
    • /
    • 제14권7호
    • /
    • pp.373-383
    • /
    • 2016
  • 모바일 시대와 핀테크에 맞물려 바이오 정보를 보안 방식으로 활용하는 바이오 인식 기술이 확산되고 있다. 특히 간편결제 서비스, 교통카드 대체, 바이오 인식 기술과 결합한 모바일 서비스가 확대되고 있다. 인증을 위한 기본 개념인 접근 제어, IA&A, OpenID, OAuth 1.0a, SSO와 생체인식기술들을 고찰하였으며, AIM의 응용 측면에서 보안 API 플랫폼을 위한 프로토콜 스택과 FIDO, SCIM, OAuth 2.0, JSON Identity Suite, OpenStack의 Keystone, 클라우드 기반의 SSO, AIM Agent 등의 기술을 세부적으로 묘사한다. 국내외 인증기술은 FIDO UAF(Universal Authentication Framework)와 U2F(Universal 2 Factor Framework) 연합 중심으로 기술개발 표준화 연구 활동을 가속화될 것이며, 본 연구에서는 최근 컴퓨팅 패러다임의 변화와 사회적 요구를 수용하기 위한 다양한 인증 기술의 동향과 AIM 프레임워크를 설계 및 기능을 정의하였다.

Low Voltage Program/Erase Characteristics of Si Nanocrystal Memory with Damascene Gate FinFET on Bulk Si Wafer

  • Choe, Jeong-Dong;Yeo, Kyoung-Hwan;Ahn, Young-Joon;Lee, Jong-Jin;Lee, Se-Hoon;Choi, Byung-Yong;Sung, Suk-Kang;Cho, Eun-Suk;Lee, Choong-Ho;Kim, Dong-Won;Chung, Il-Sub;Park, Dong-Gun;Ryu, Byung-Il
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권2호
    • /
    • pp.68-73
    • /
    • 2006
  • We propose a damascene gate FinFET with Si nanocrystals implemented on bulk silicon wafer for low voltage flash memory device. The use of optimized SRON (Silicon-Rich Oxynitride) process allows a high degree of control of the Si excess in the oxide. The FinFET with Si nanocrystals shows high program/erase (P/E) speed, large $V_{TH}$ shifts over 2.5V at 12V/$10{\mu}s$ for program and -12V/1ms for erase, good retention time, and acceptable endurance characteristics. Si nanocrystal memory with damascene gate FinFET is a solution of gate stack and voltage scaling for future generations of flash memory device. Index Terms-FinFET, Si-nanocrystal, SRON(Si-Rich Oxynitride), flash memory device.

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.