• Title/Summary/Keyword: Stack effect

Search Result 326, Processing Time 0.023 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

A Study on the Gas-liquid Separation Effect of the Knockout Drum in the Flare System (플레어시스템에서 녹아웃드럼의 기·액 분리효과에 관한 연구)

  • Kwon, Hyun-Gil;Baek, Jong-Bae;Kim, Sang-Ryung
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.1-8
    • /
    • 2021
  • Among the flare systems that handle discharged substances from safety valves, the knockout drum was a key facility for safety, but the installation standards were not clear, so it was necessary to review the standards acceptable to the workplace and regulatory agencies. After investigating the domestic and foreign technical standards of knockout drums and the deficiencies of previous studies, research was first conducted on the degree of mass discharge, the installation location of the intermediate knockout drum, and the effect of changes in the composition of the discharged material. As a result of the study under the process simulation conditions, the gas-liquid separation of the knockout drum was completed in a small amount of less than 7,500kg/hr. However, when more than that was released, the gas-liquid separation effect was small even with the addition of an intermediate knockout drum. In addition, when the composition ratio of the material easily condensed was increased (molar fraction 10%), the gas-liquid separation effect of the knockout drum increased in the case of mass release. The gas-liquid separation effect was analyzed to be greater when the knockout drum was installed adjacent to the stack than the knockout drum was installed adjacent to the process equipment.

The Study on the Effect of Elevator Movement on the Pressure Difference between Vestibule and Living room in High-rise Buildings (초고층 건축물에서 엘리베이터 구동이 부속실과 화재실 간 차압형성에 미치는 영향연구)

  • Park, Younggi;Hong, Kibea;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.85-91
    • /
    • 2018
  • Recently, there have been a lot of casualties due to fires in high-rise buildings. The toxic gases and smokes generated by fires in high-rise buildings spread rapidly through the elevator shaft and stairwell, due to the stack effect, and can cause critical casualties. To reduce the number of casualties, smoke control systems have been introduced. Smoke control systems play an essential role in preventing the spread of smoke in high-rise buildings and securing the evacuation route. Also, in high-rise buildings, evacuation by an elevator is considered to be indispensable. However, the pressure field in the shaft is strongly disturbed when the elevator is moving and this can affect the performance of the smoke control system. Therefore, in this study, we experimentally and numerically analyzed the effect of elevator movement on the pressure difference between the vestibule and living room by building a model using the sandwich pressurization method based on the performance based design. To consider the leakage areas in high-rise buildings, e.g. the windows, fire door and elevator, the National Fire Safety Codes and area ratio were used. The elevator speed in the model building was varied between 20 m/s and 100 m/s corresponding to a real elevator speed of 7 m/s~17 m/s. As a result, the relationship between the pressure difference and elevator speed was found to be ${\Delta}P=40{\cdot}{\exp}$(-Ves /-104.7)-23.735. This result can be used to take into consideration the effect of elevator movement when designing smoke control systems.

Identification of Internal Resistance of Microbial Fuel Cell by Electrochemical Technique and Its Effect on Voltage Change and Organic Matter Reduction Associated with Power Management System (전기화학적 기법에 의한 미생물연료전지 내부저항 특성 파악 및 전력관리시스템 연계 전압 변화와 유기물 저감에 미치는 영향)

  • Jang, Jae Kyung;Park, Hyemin;Kim, Taeyoung;Yang, Yoonseok;Yeo, Jeongjin;Kang, Sukwon;Paek, Yee;Kwon, Jin Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.5
    • /
    • pp.220-228
    • /
    • 2018
  • The internal resistance of microbial fuel cell (MFC) using stainless steel skein for oxidizing electrode was investigated and the factors affecting the voltage generation were identified. We also investigated the effect of power management system (PMS) on the usability for MFC and the removal efficiency of organic pollutants. The performance of a stack microbial fuel cell connected with (PMS) or PMS+LED was analyzed by the voltage generation and organic matter reduction. The maximum power density of the unit cells was found to be $5.82W/m^3$ at $200{\Omega}$. The maximum current density was $47.53A/m^3$ without power overshoot even under $1{\Omega}$. The ohmic resistance ($R_s$) and the charge transfer resistance ($R_{ct}$) of the oxidation electrode using stainless steel skein electrode, were $0.56{\Omega}$ and $0.02{\Omega}$, respectively. However, the sum of internal resistance for reduction electrode using graphite felts loaded Pt/C catalyst was $6.64{\Omega}$. Also, in order to understand the internal resistance, the current interruption method was used by changing the external resistance as $50{\Omega}$, $300{\Omega}$, $5k{\Omega}$. It has been shown that the ohm resistance ($R_s$) decreased with the external resistance. In the case of a series-connected microbial fuel cell, the reversal phenomenon occurred even though two cells having the similar performance. However, the output of the PMS constantly remained for 20 hours even when voltage reversal occurred. Also the removal ability of organic pollutants (SCOD) was not reduced. As a result of this study, it was found that buffering effect for a certain period of time when the voltage reversal occurred during the operation of the microbial fuel cell did not have a serious effect on the energy loss or the operation of the microbial fuel cell.

A New RFID Multi-Tag recognition Algorithm using Collision-Bit (RFID 충돌 비트를 이용한 다중 태그 인식 알고리즘)

  • Ji, Yoo-Kang;Cho, Mi-Nam;Hong, Sung-Soo;Park, Soo-Bong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.55-58
    • /
    • 2008
  • RFID(Radio frequency IDentification) leader is collision of data, when recognizing the multiple tag the inside area. This collision became the cause which delays the tag recognition time of the leader. The protocol which prevents the delay of tag recognition time of the leader the place where representative it uses QT(Query Tree) algorithms, it uses a collision bit position from this paper and are improved QT-MTC(Query Tree with Multi-Tag Cognition) algorithms which it proposes. This algorithm stored the bit position which bit possibility and the collision where the collision happens occurs in the stack and goes round a tree the number of time which, it reduced could be identified two tags simultaneously in order, it was planned. A result of performance analysis, It compared in QT protocols and the this algorithm against the tag bit which is continued a tush efficiency improvement effect was visible.

  • PDF

Variation of Porosity and Gas Permeability of Gas Diffusion Layers Under Compression (가스확산층의 압축에 따른 공극률 및 기체투과율의 변화)

  • Lee, Yongtaek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.767-773
    • /
    • 2013
  • This study suggested the variations of porosity and gas permeability of gas diffusion layers (GDLs), which are easily deformed among the components of a highly compressed PEMFC stack. The volume change owing to compression was measured experimentally, and the variations in the porosity and gas permeability were estimated using correlations published in previous literature. The effect of polytetrafluoroethylene (PTFE) which is added to the GDLs to enhance water discharge was investigated on the variations of porosity and gas permeability. The gas permeability which strongly affects the mass transport through GDL, decreases sharply with increasing compression when the GDL has high PTFE loading. As a result, the mass transport through the pore network of GDL can be changed considerably according to the PTFE loading even with the same clamping force. The accuracy of modeling of transport phenomena through GDL can be improved due to the enhanced correlations developed based on the results of this study.

The Corrosion Behavior of Li/K Carbonate Melts with CaCO3 Additives on Separator Plate in the Molten Carbonate Fuel Cell in the Anode Environments

  • Cho, Kyehyun;Lee, Chul-Hwan;Sung, Zu-Hwan
    • Corrosion Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.129-136
    • /
    • 2006
  • High temperature corrosion behavior of AISI-type 316L stainless steel for the MCFC(molten carbonate fuel cell) bipolar application was studied by immersion test and penetration attack method in anode environment ($650^{\circ}C$, $Li_2CO_3/K_2CO_3=62/38$ mol%, $H_2/CO_2=80/20$ vol%) without or with different $CaCO_3$ content. Not only immersion test method but also morphological observation of samples in the carbonate melts are adopted as experimental methods. With aid of the morphological observation of cross section of samples immersed in a carbonate melt was possible to obtain penetration attack. The concentration effect of $CaCO_3$ inhibitor was investigated in order to verify the optimum concentration for practical application in MCFC stack operation. The corrosion rate in the presence of $CaCO_3$ was proven to be decreased as a function of $CaCO_3$ concentration. The corrosion rate in the presence of $CaCO_3$ was measured with a value of 6.9 mpy which is 2.4 times lower than that of inhibitor-free electrolyte. The cross section microscopy revealed that the internal penetration by oxidation in molten carbonate is very severe. In this case, the attack was occurred not only dissolution loss in the electrolyte by corrosion reaction but also weight gain through oxide layer by internal penetration.

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.

Evaluation of EtherCAT Clock Synchronization in Distributed Control Systems (분산 제어 시스템을 위한 EtherCAT 시계 동기화의 성능 평가)

  • Kim, Woonggy;Sung, Minyoung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.7
    • /
    • pp.785-797
    • /
    • 2014
  • Support for the precise time synchronization of EtherCAT, known as distributed clock (DC), enables the design of highly synchronized operations in distributed real-time systems. This study evaluates the performance of the EtherCAT DC through extensive experiments in a real automation system. We constructed an EtherCAT control system using Xenomai and IgH EtherCAT stack, and analyzed the clock deviation for different devices in the network. The results of the evaluation revealed that the accuracy of the synchronized clock is affected by several factors such as the number of slave devices, period of drift compensation, and type of system time base. In particular, we found that careful decision regarding the system time base is required because it has a fundamental effect on the master operation, which results in significantly different performance characteristics.

Shape Factor Analysis of Fresh Red Pepper Affecting the Performance of Unfolding, Arranging and Cutting (전개 .정렬 . 절단 성능에 영향을 미치는 홍고추 형상 요인 분석)

  • 나우정;이승규;송대빈;김영복;이태곤
    • Journal of Biosystems Engineering
    • /
    • v.26 no.6
    • /
    • pp.563-570
    • /
    • 2001
  • To develop a stalk detaching system the effect of shape factor of red pepper affecting the performance of unfolding, arranging and cutting was analysed. The obtained results are as follows : By cutting experiment, it was found that the bending of stalk affected the cutting rate of stalk, and that the bending of body increased the amount of peppers that were expelled from the cutting guide by conveying brush. The ratios, 'bending length of a body/body length'and 'bending length of a stalk/stalk length', could be used as criteria far abnormality of body and stalk of peppers, respectively. As a result of experiment, it was concluded that mechanical treatment would be difficult for the peppers with indexes greater than 0.4 and 0.3 fur body bending and stack bending. respectively. So, these indexes were used as criteria for distinguishing abnormality from normality of peppers. In the unfolding unit, conveyance of peppers was impossible for both of normal and abnormal ones at the inclination angle of 10°, especially, at the frequency of 8.3 Hz peppers maintained stationary state. At the inclination angle of 20°, both of normal and abnormal peppers showed similar tendencies, but abnormal ones showed an accumulation trend gradually with increased feeding speed. In the arranging unit, conveyance of peppers was almost impossible for both of normal and abnormal ones at the inclination angle of 20°, showing almost no difference between the conveyances of normal and abnormal ones. In the case of the inclination angle of 30°, at the condition of the feeding speeds and frequency corresponding 0.06 m/s, 0.08 m/s and 8.3 Hz, respectively, the passing time of the abnormal peppers on the arranging plate increased rapidly.

  • PDF