• Title/Summary/Keyword: Stack Type

Search Result 294, Processing Time 0.024 seconds

A Comparative Study on the Characteristics of Thermoacoustic Waves by the Stack Channel Number (스택의 채널 수에 다른 열음향파의 특성 비교 연구)

  • Park, Sung-Seek;Cheon, Won-Gi;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.8-14
    • /
    • 2013
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level(SPL), onset time and the temperature gradient across the stack, with the Cell Per Square Inch(CPSI) of stack changed. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. As a result, when the supply electric power was 25W, maximum SPLs of 104.1 dB, 109.4 dB and 112.8 dB were detected for the stacks of 200, 300 and 400 CPSI and their respective stack positions of 70mm, 60mm and 50mm from the closed end.

A Study on the Retention Efficiency of Library Materials of Automated Storage and Retrieval System (자동서고의 자료 수장 효율성에 관한 연구)

  • Kim, Young-Seok
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.49 no.3
    • /
    • pp.437-456
    • /
    • 2015
  • This study aims to compare the retention efficiency of library materials of Automated Storage and Retrieval System(AS/RS) revealed by the literature review to other types of book stacks. Domestic and foreign academic libraries adopted AS/RS as part of a plan to improve the retention efficiency. Literature review reveals that in general, AS/RS is better in the retention efficiency in compare to other types of book stacks. This study compared the amount of library materials stored by the AS/RS of S University Library to the general book stack and the fixed-type and the mobile rack-type of virtual book stacks. The study reveals that AS/RS is up to 6 times more efficient than general book stacks, up to 3.61 times more efficient than fixed-type book stacks and up to 1.45 times more efficient than mobile rack-type book stacks. However, the study claims that the retention efficiency of library materials of AS/RS is lower than what is known.

Development of Cell Voltage Monitoring Module for PEMFC (연료전지 스택의 셀 전압 감시를 위한 장치 개발)

  • Jung, Jae-Wook;Kim, Tae-Hoo;Park, Hyun-Seok;Jeon, Ywun-Seok;Ku, Bon-Woong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.376-379
    • /
    • 2006
  • In this paper, stack voltage monitoring module is developed which monitor cell voltage of the fuel cell stack and transfer it to the main controller for monitoring fault and stopping drive when the trouble is happened in the fuel cell stack. Especially, the circuit, for monitoring each cell voltage of several hundreds cells in stack, is designed and analyzed. The connector is also developed for making wire harness simple and low cost because wire harness is complicated when the cells are connect each monitoring circuit.

  • PDF

Analytical Study on the Oscillating Flow Effect in a Anode Channel of Direct Methanol Fuel Cells (연료극 왕복유동이 직접 메탄올 연료전지에 미치는 영향에 대한 해석적 연구)

  • Hwang, Yong-Sheen;Lee, Dae-Young;Kim, Seo-Young;Choi, Hoon;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.27-30
    • /
    • 2007
  • This study considers the feasibility of the concentration control of the methanol solution by oscillating flow in the anode channel of passive type Direct Methanol Fuel Cells(DMFC). DMFC stack performance is largely influenced by the fuel concentration. If the fuel concentration is either lower than 0.5M or more than 2M, its performance deteriorates seriously because of the fuel starvation or the fuel crossover. In this respect the optimization of the fuel concentration is crucially important to maximize the DMFC stack performance. In this work, the effects of oscillating actuation in the fuel supply are studied to control the fuel concentration. Two important nondimensional parameters are introduced, each of which represents either the oscillating frequency or the oscillating amplitude. It is shown how these factors affect the stack performance and the efficiency of the DMFC stack.

  • PDF

Design of Bytecode Framework (바이트코드 프레임워크 설계)

  • 김영국;김기태;조선문;이갑래;유원희
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.05a
    • /
    • pp.330-334
    • /
    • 2004
  • Java bytecode is stack-base code. Stack-base code makes analysis and optimization hardly because use stack access imperative. Therefore, fragment of code that is problem that occur in stack-base code optimization, loss of type information, unnecessary Load and Store can appear. Optimization and analysis of bytecode design bytecode framework by solution way of problem that is difficult. This paper indicates optimization of bytecode and hangup of analysis, and describe research contents about existent byte code optimization technology. This propose byte code framework by the alternative to simplify analysis and optimization of byte code.

  • PDF

Study on safety performance evaluation of stationary SOFC stack (건물용 고체산화물연료전지 스택 안전성능평가 연구)

  • Park, Tae Seong;Lee, Eun Kyung;Lee, Seung Kuk
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-12
    • /
    • 2018
  • The code and standards related to fuel cells were analyzed to derive the SOFC(Solid Oxide Fuel Cell) stack safety performance evaluation items and evaluation methode. Safety performance evluation of the SOFC stack was tested by quoting derived test items. The stack used in the test is an anode-supported type 2 Cell stack (Active surface area : 220cm) manufactured by MICO Inc, and SOFC stack safety performance evaluation system used for the test is self-manufactured. We conducted a leakage test, current voltage characteristic test, rated output test, and power response characteristics test. In the safety performance evaluation test, the stack showed no gas leakage, the maximum output and rated output was recorded to 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 62.3 W(1.57 V, 40 A, $363mA/cm^2$). In the power response characteristics test verified that the output is kept stable within two seconds. At the maximum load (40 A) and the minimum load (8 A), the output was recorded 62 W and 16W in $750^{\circ}C$. This study will contribute to the universalization and to provide much safe environment of operating the solid oxide fuel cell system.

Position Control of Ultra-Precision Machine Tool Post using Piezoelectric Material(1) (압전 재료를 이용한 초정밀 가공기용 공구 위치 제어(1))

  • 김승한;송하성;송재욱;김의중
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.162-166
    • /
    • 1996
  • This paper presents a position control of ultra-precision machine tool post using piezoelectric material. A stack-type piezoelectric actuator Is employed in a hinge-type tool holder. An assumed linear transfer function of the practical nonlinear plant is established through the comparison of transfer functions and step responses in the experiments and the simulations. Several types of feedforward/feedback controllers are designed via computer simulations using the assumed linear transfer function. The position tracking control experiments are undertaken to show the control efficiency of each controller.

  • PDF

Characteristics of the Multi-kW Class Polymer Electrolyte Membrane Fuel Cell Stack for a Hybrid Electric Golf Cart

  • I.H. Oh;S.J. Shin;J.H. Jo;Park, S.K.;H.Y. Ha;S.A. Hong;S.Y. Ahn;Lee, Y.C.;S.A. Cho
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.254-261
    • /
    • 2002
  • The fabrication method for the main components of the polymer electrolyte membrane fuel cell stack such as electrodes, membrane-electrode assemblies, and bipolar plates was established for the effective electrode area of 240 ㎠. A counter-flow type 100-cell stack was fabricated by using the above components and then a maximum power of 7.44 kW for H$_2$/O$_2$ and 5.56 kW for H$_2$/air could be obtained at 70$\^{C}$ and 1 atm. It was seen that the distribution of the OCV for unit cells in the stack was uniform but the voltage deviation increased as the load increased due to the IR drop and the electrode polarization. The stack was applied to the power source of the fuel cell/battery hybrid electric golf car. It produced about 1 kW at a room temperature operation during the test run, which occupied about 43% of the total power required by the 2.3 kW motor.

Build and Performance Test of a 3-cell Solid Oxide Fuel Cell Stack

  • Cho, Nam-Ung;Hwang, Soon-Cheol;Han, Sang-Moo;Yang, Choong-Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.8
    • /
    • pp.407-411
    • /
    • 2007
  • A 3-cell stacked anode-supported solid oxide fuel cell was designed and fabricated to achieve a complete gas seal and the facile stacking of components. The stack was assembled with a unit cell with $10{\times}10cm^2$ area, and each cell was interconnected by a stainless steel 430 separator using a proprietary sealant sheet. The stack performance was examined at various gas flow rates of $H_2+3.5vol%\;H_2O$, and air at a fixed temperature of $800^{\circ}C$. No gas leakage was found from the sealing between cells and inter-connects within a measurement system in this research during a prolonged time of 500 h in operation. The test resulted in an open circuit voltage of 3.12 V, a peak power of 149 W, and a power density of $0.61W/cm^2$, while the long term durability of the power showed 19.1% degradation during the prolonged time of 500 h when tested at $800^{\circ}C$.

Effect of Field Orientation on Magnetization Loss in a Stacked Bi-2223 Conductor (자장방향이 적층 Bi-2223도체의 자화손실에 미치는 영향)

  • 류경우;김현준
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.1
    • /
    • pp.77-82
    • /
    • 2003
  • The ac loss is an important issue in the design of high-Tc superconducting power devices such as transformers and cables. In these devices many Bi-2223 tapes are closely stacked together and exposed to alternating magnetic fields that can have different orientations with respect to a tape. In such arrangement the magnetization loss is influenced by the screening current induced in adjacent tapes and thus different from that in a single tape. This stacking effect was experimentally investigated by measuring the magnetization loss in a stack, which consists of a number of tapes. First the magnetization loss in the single tape was measured in order to confirm the reliability of the loss data measured in the stack. The results for the single tape coincide well will the loss characteristics described in other previous works. For the stack In parallel and longitudinal magnetic fields the measured loss is Independent of both the number of tapes and stacking type. The longitudinal magnetization loss Is well explained rather by the slab model for decoupled filaments. For the tall stack in perpendicular field the measured loss at low fields is greatly decreased, compared to the loss of the single tape. However the loss at high fields is unaffected. These loss behaviors in the tall stack are well described by the slab model for full coupling.