• Title/Summary/Keyword: Stack Protection

Search Result 54, Processing Time 0.025 seconds

Detection Mechanism against Code Re-use Attack in Stack region (스택 영역에서의 코드 재사용 공격 탐지 메커니즘)

  • Kim, Ju-Hyuk;Oh, Soo-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3121-3131
    • /
    • 2014
  • Vulnerabilities related to memory have been known as major threats to the security of a computer system. Actually, the number of attacks using memory vulnerability has been increased. Accordingly, various memory protection mechanisms have been studied and implemented on operating system while new attack techniques bypassing the protection systems have been developed. Especially, buffer overflow attacks have been developed as Return-Oriented Programing(ROP) and Jump-Oriented Programming(JOP) called Code Re-used attack to bypass the memory protection mechanism. Thus, in this paper, I analyzed code re-use attack techniques emerged recently among attacks related to memory, as well as analyzed various detection mechanisms proposed previously. Based on the results of the analyses, a mechanism that could detect various code re-use attacks on a binary level was proposed. In addition, it was verified through experiments that the proposed mechanism could detect code re-use attacks effectively.

Determination of $^{226}Ra$ Isotope in the Leachate around Phosphogypsum Stack Using Ethylenediaminetetraacetic Acid (EDTA) (Ethylenediaminetetraacetic acid (EDTA)를 이용한 인산석고 야적장 침출수 중의 $^{226}Ra$ 분석법 개발)

  • Kim, Geun-Ho;Kim, Yong-Jae;Chang, Byung-Uck
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.223-229
    • /
    • 2011
  • Ba is the most useful element to get the $Ba(Ra)SO_4$ precipitate. However, when the high concentrations of ions such as sulfate, calcium are existed in the leachate of phosphogypsum stack, it is difficult to get the $Ba(Ra)SO_4$ precipitate. Since this reason, the developed method for the Ba coprecipitate using EDTA was performed to determine the $^{226}Ra$ concentration in the high sulfate sample. The average concentration of $^{226}Ra$ in a leachate of phosphogypsum using this method was 0.102 $Bq{\cdot}kg^{-1}$ and the minimal detectable activity is 3.4 $mBq{\cdot}kg^{-1}$. The $mBq{\cdot}kg^{-1}$ method was 0.102 $Bq{\cdot}kg^{-1}$ and the minimal detectable activity is 3.4 $mBq{\cdot}kg^{-1}$. The $^{226}Ra$ stock solution and the CRM (Certified Reference Material) were analyzed to verify this method. In analyzed $^{226}Ra$ stock solution, bias with added concentration was approximately 1% and the correlation curve between $^{226}Ra$ concentration in simulated standard sample and measured $^{226}Ra$ concentration showed good agreement with a correlation coefficient ($R^2$) of 0.99. In analyzed CRM, maximum bias with reference value was 5.8% (k=1) and the analytical results were in good agreement with the reference value.

Review on the Management for Radioactive Effluent and Methodology for Setting of Derived Release Limits at Pressurized Heavy Water Reactors in Korea (중수로원전 방사성유출물 관리와 유도배출한계 설정방법에 대한 고찰)

  • Kim, Hee-Geun;Kong, Tae-Young;Jeong, Woo-Tae;Kim, Seok-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.172-177
    • /
    • 2010
  • The radioactive effluents from pressurized heavy water reactors (PHWRs) are relatively larger than those from pressurized water reactors (PWRs). Futhermore, radioactive effluents from PHWRs are released continuously. Thus, the discharge of radioactive effluents is strictly controlled. To do this, radiation detectors are installed at stacks of reactor buildings to monitor the concentration of radioactive effluents in real-time. Derived release limits (DRLs) of annual discharge are also set up for each radionuclide and effluents are rigidly controlled not to exceed those limits. In this paper, the discharge process of radioactive effluents, the standard for establishment of DRL and its methodology, and currents status for PHWRs were reviewed.

A detection mechanism for Jump-Oriented Programming at binary level (바이너리 수준에서의 Jump-Oriented Programming에 대한 탐지 메커니즘)

  • Kim, Ju-Hyuk;Lee, Yo-Ram;Oh, Soo-Hyun
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.5
    • /
    • pp.1069-1078
    • /
    • 2012
  • It is known that memory has been frequently a target threatening the computer system's security while attacks on the system utilizing the memory's weakness are actually increasing. Accordingly, various memory protection mechanisms have been studied on OS while new attack techniques bypassing the protection systems have been developed. Especially, buffer overflow attacks have been developed as attacks of Return to Library or Return-Oriented Programing and recently, a technique bypassing the countermeasure against Return-Oriented Programming proposed. Therefore, this paper is intended to suggest a detection mechanism at binary level by analyzing the procedure and features of Jump-Oriented Programming. In addition, we have implemented the proposed detection mechanism and experimented it may efficiently detect Jump-Oriented Programming attack.

Development of High Voltage Switch Stack with Thyristors Stacked in Series (싸이리스타 소자의 직렬연결형 고전압 스위치스택 개발)

  • Son, Y.G.;Oh, J.S.;Jang, S.D.;Cho, M.H.;Ro, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2597-2600
    • /
    • 1999
  • Semiconductor devices can be series stacked for the application of high voltage switching. It can provide high reliability and long lifetime by the safe design with a reasonable margin. The equal voltage distribution at solid-state switches in series should be guaranteed. Static and dynamic voltage division, over current protection must be considered carefully in the design stage. A fast switching thyristor is a good candidate for the high power pulse applications. A high voltage switching module is designed and tested. Its specifications are working voltage of 70 kV, switching pulse width of 120${\mu}s$, peak switching current of 220A, maximum repetition rate of 200pps. The module can be series connected to get higher working voltage. This paper presents the design details and the test results are compared with expected circuit simulations.

  • PDF

Development of a High Voltage Semiconductor Switch for the Command Charging o (모듈레이터의 지령충전을 위한 고전압 반도체 스위치 개발)

  • Park, S.S.;Lee, K.T.;Kim, S.H.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2067-2069
    • /
    • 1998
  • A prototype semiconductor switch for the command resonant charging system has been developed for a line type modulator, which charges parallel pulse forming network(PFN) up to voltage of 5 kV at repetition rates of 60 Hz. A phase controlled power supply provides charging of the 4.7 ${\mu}s$ filter capacitor bank to voltage up to 5 kV. A solid state module of series stack array of sixe matched SCRs(1.6 kV, 50 A) is used as a command charging switch to initiate the resonant charging cycle. Both resistive and RC snubber network are used across each stage of the switch assembly in order to ensure proper voltage division during both steady state and transient condition. A master trigger signal is generated to trigger circuits which are transmitted through pulse transformer to each of the 6 series switch stages. A pulse transformer is required for high voltage trigger or power isolation. This paper will discuss trigger method, protection scheme, circuit simulation, and test result.

  • PDF

A Study on Block from Spread of Fire of the Exteriors Installation Space (외장재 설치 공간의 화재확산 차단에 관한 연구)

  • Min, Se-Hong;Yun, Jung-Eun;Kim, Mi-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.2
    • /
    • pp.83-89
    • /
    • 2012
  • In this study, FDS fire simulation experiments and measured wind speed by applying the exterior installation portion for blocking the spread of the fire was investigated. As a result, aluminum composite panels installed in the lower and the upper part of the panel to remove all the lower side, and then the maximum wind speed 0.24 m/s and the upper side 0.58 m/s were measured. In the FDS, the measured wind speed difference air currents are approximately 3.7 times in 12 seconds, the occurrence of 17 seconds early moment wind 2.2 m/s was measured from. Before and after the fire occurred in early of the air velocity about 39 seconds was 3.5 times difference. Such air currents caused by the temperature of the building but also by the building height was found. Turbulent flame of fire by expanding the vertical extent of damage become greatly important factor. Therefore, through the exterior installation portion of the block that can delay the spread of fire is expected that this should be taken.

Vibration Characteristics of the Pears in Corrugated Fiberboard Container for Packaging be stacked at Simulated Transportation Environment (모의 수송환경에서의 적재된 골판지 포장화물 내 배의 진동특성)

  • Jung, Hyun-Mo;Park, In-Sig;Kim, Man-Soo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.11 no.1
    • /
    • pp.11-16
    • /
    • 2005
  • Fruits are subjected to complex dynamic stresses in the transportation environment. During a long journey form the production area to markets, there is always some degree of vibration present. Vibration inputs are transmitted from the vehicle through the packaging to the fruit. Inside, these cause sustained bouncing of fruits against each other and container wall. These steady state vibration input may cause serious fruit injury, and this damage is particularly severe whenever the fruit inside the package is free to bounce, and is vibrated at its resonance frequency. The determination of the resonant frequencies of the fruit may help the packaging designer to determine the proper packaging system providing adequate protection for the fruit, and to understand the complex interaction between the components of fruit when they relate to expected transportation vibration inputs. The first frequency of the pear in packaged freight be stacked in resonance frequency band of the pear packaged freight was increased from the bottom to the top of the stack but the second frequency of that in resonance frequency band of the pear was decreased. This indicated that the high damage score of the pear in bottom tier in vibration test was due to higher acceleration level in resonance frequency band of the pear.

  • PDF

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.

Design and Implementation of Turbidity Measurement Module of Plume using a Digital Camera (디지털카메라를 이용한 굴뚝연기의 혼탁도 측정모듈의 설계 및 구현)

  • Ban, ChaeHoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.372-378
    • /
    • 2015
  • Smoke generated from business establishments and factories will not only cause air pollution but also have a significant impact on the human body. Generally, the most common method for measuring the turbidity of the plume generated from the stack is a method of observing by the transmissometer mounted in the chimney or Method 9 from the US EPA(Environmental Protection Agency) which is a visual method of determining plume turbid emitted from stationary sources. However, these methods need a lot of cost to build and maintain. In this paper, we build a plume turbidity measurement module programs using a digital camera. We design and implement a module which acquires the pictures of the plume using a digital camera and measures the turbidity of it using the DOM(Digital Optical Method). In addition, we demonstrate the excellence by comparing and analyzing implemented module and other methods.