분뇨처리장의 공정개선에 의한 처리효율 향상에 관한 연구 (Improvement of treatment efficiency for sanitary treatment facilities by process modifications)

  • 이찬원;김승현;김창수;문성원;전홍표;윤종섭
    • 한국환경과학회지
    • /
    • 제13권6호
    • /
    • pp.571-579
    • /
    • 2004
  • There is a need to improve the efficiency of the existing sanitary treatment facilities, because the effluent standard becomes more stricter and septic sludge increased. Thus, operating processes of sanitary treatment system in M city changed with installation of additional facilities. Process modifications were as follows: Dilution water was added to the next process after primary aeration tank. Some secondary sedimentation sludge was recycled to primary aerator so that most of the organics were stabilized in primary aeration tank under automatic control of dissolved oxygen. The line of effluent from dewatering process flowing to the activated sludge tank was changed to the primary aerator. The primary sedimentation sludge line was linked to a thickener. Polymer was added to the activated sludge tank. The effluent of primary aerator and aerobic digester was recycled from the 5th to the 1st sector. As consequencies of above process modifications, the improvement of removal efficiency was achieved as BOD 54%, COD 42%, SS 61%, T-N 39%, and T-P 12%, respectively.

FGS를 이용한 황전등 전원장치의 설계 및 구현 (The Design and Implementation of Inverter Power Supply with FGS for Sulfur Lamp)

  • 정원근
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.10-16
    • /
    • 2005
  • 본 논문에서는 퍼지 이득 조정기를 이용한 황전등 전원장치를 제안하고, 회로를 설계하고 제작을 통해 성능을 확인하였다. 직렬 공진 하프 브리지 인버터를 기본으로 하여 전원변동 및 출력 보상을 위한 PFM(Pulse Frequency Modulation), 영전압 스위칭, 소프트 스위칭, 소프트 스타트를 적용하고 퍼지 이득 조정 알고리즘을 통해 역률과 효율을 개선하여 마그네트론의 수명 연장 및 안정된 출력을 얻을 수 있도록 하였고, 기존의 고정 출력에서 $900\~1250[W]$ 연속 가변 출력이 가능하게 하였다. 제작된 전원장치는 전원 전압의 변동에 대하여 상용 전원 $220V{\pm}15[\%]$에서 안정적인 출력 특성과 광효율 97[1m/W], 역률 $96[\%]$로서 만족한 결과를 얻을 수 있었다.

2차원 강소성 유한요소해석에서의 안정성 및 효율성 향상에 관한 연구

  • 박근;양동열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.195-199
    • /
    • 1993
  • In the analysis of metal forming processes by the finite element method, there are many numerical instabilities such as element locking, hourglass mode, shear locking. These instabilities may have a bad effect upon accuracy and convergence. The present work is concerned with improvement of stability and efficiency in two dimensional rigid-plastic finite element method using various type of elements and numerical integration schemes. AS metal forming examples, upsetting and backward extrusion are taken for comparison among the methods : various element types and numerical integration schemes. comparison is made in terms of stability and efficiency. As a result, it has been shown that the finite element computation is stabilized from the viewpoint of computational time, convergency, and numerical instability.

  • PDF

Elctrokinetic-Fenton 기법 적용시 토질조건과 오염원의 종류에 따른 과산화수소의 주입특성

  • 김정환;김병일;한상재;김수삼
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.30-33
    • /
    • 2002
  • In this study, feasibility of using hydrogen peroxide as a chemical oxidant for in-situ treatment by EK-Fenton technology were investigated. Kaolinite, kaolinite/sand mixture and illitic soil spiked by phenol and phenanathrene were used and variation of electrochemical characteristics were examined by EK-Fenton test. For kaolinite that having low buffer capacity, hydrogen peroxide was injected effectively from anode reservoir. However illitic soil that having relatively higher buffer capacity had low hydrogen peroxide introducing efficiency. The test results showed that Hydrogen ions generated by current increased during the treatment decreased under pH 3 in the most of kaolinite specimen. Therefore, stabilized hydrogen oxide was injected more effectively in the kaolinite specimen. This study suggests that efficiency of hydrogen peroxide injection by EK-Fenton thechnoloty is dependent of variation of pH in the soil

  • PDF

슬림광디스크드라이브를 위한 고감도 3축구동 액추에어터 (High Sensitivity 3-axis Actuator for Slim Optical Disc Drive)

  • 정영민;이진원;김광
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.1000-1003
    • /
    • 2002
  • For high density optical storage, there should be a high NA objective lens and a shorter wavelength laser diode. To secure the disc tilt margin related to the coma aberration, moreover, it's difficult to apply the tilt compensation mechanism into the portable PC. In this paper, we proposed the 3-axis asymmetry pickup actuator with high efficiency symmetric magnetic circuit, which consisted of the top cover type inner yoke for high magnetic flux density, the coil stack unit for the 3-axis independent operation and vertically polarized magnets. This newly suggested actuator features DVD-RAM recording, we achieved the high focus & track AC sensitivity and the greatly stabilized system.

  • PDF

조명용 LED 램프의 사용 시간에 따른 연색지수 특성변화 (Aging-Time Dependence of Color Rendering Index of a LED Lamp for Lighting)

  • 손민우;이덕희;서정철
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.1-6
    • /
    • 2014
  • We measured color rendering index(CRI) of a LED lamp for lighting for aging-time. We chose bulb type white LED lamp six samples and halogen lamp one sample and applied 220V, 60Hz to all the samples for 1,000hours at ordinary temperature. The CRI was measured every 20hours and the CRI change of the LED lamp was compared with the halogen lamp's CRI change. As time goes, efficiency of the halogen lamp decreased and the CRI maintained uniformly. The other hand, efficiency of the LED lamp decreased but the CRI increased. The CRI of the LED lamp has been stabilized since 600hours. The CRI change of the LED lamp was analyzed with a spectrum, color coordinate and color temperature.

Nitrification Efficiency in Fixed Film Biofilters using Different Filter Media in Simulated Seawater Aquarium System

  • Peng, Lei;Jo, Jae-Yoon
    • 한국양식학회지
    • /
    • 제16권4호
    • /
    • pp.203-209
    • /
    • 2003
  • Nitrification efficiency of fixed film biofilters with sand, loess bead, and styrofoam bead in biofilter columns of 1-m height and 30 cm width was studied. Synthetic wastewater was continuously supplied to the culture tank to maintain total ammonia nitrogen (TAN) concentration in the inflow water at around 8 mg/L. The hydraulic loading rate was set at 200 ㎥/$m^2$/day. TAN conversion was stabilized after about 90 day conditioning for all the selected filter media but with net accumulations of nitrite. On the volumetric basis, conversion rates of TAN and nitrite were the highest in styrofoam bead filter. Mean volumetric TAN conversion rates in the final samples were 682, 269, and 79 g TAN/㎥/day in the styrofoam bead, sand and loess bead filters, respectively. Low gravity and cost of styrofoam bead render the handling easier and more cost-effective.

20W급 보조전원용 다출력 QR 플라이백 컨버터의 출력전압 안정화에 관한 연구 (A Study on Output Voltage Stabilization of 20W Class Multi-output QR Flyback Converter for Auxiliary Power)

  • 유정상;길용만;김현배;안태영
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.157-160
    • /
    • 2021
  • In this paper, a 20W class multi-output QR flyback converter for auxiliary power supply was designed to stabilize 4 output voltages, and the efficiency and load characteristics were compared and analyzed. It was checked if each output affects other output characteristics through experiment. As a result, the experimental circuit reached a high efficiency of 82.5% or more at a load power of over 20W, and the maximum power loss was 2.6W. Consequently, it was confirmed that all of 4 output voltages of the multi-output QR flyback converter constructed in this paper were stabilized within 0.5% in full-load range, and each output was independently controlled in an electrically isolated state.

현장 계측을 통한 블록형 보강토옹벽 곡선부 보강 영역의 거동 특성 연구 (A Study on Behavior Characteristics of Reinforcement Zone of Block Type Mechanically Stabilized E arth Wall by Field Measurement in Curved Section)

  • 이소연;김영제;오동욱;이용주;정혁상
    • 한국지반신소재학회논문집
    • /
    • 제18권2호
    • /
    • pp.23-36
    • /
    • 2019
  • 본 논문에서는 블록식 보강토옹벽의 현장계측을 통해 곡선부 보강영역의 변형특성을 분석하였다. 보강토공법은 설계 및 시공이 증가하여 실생활에서 쉽게 접할 수 있게 되었으나, 곡선부의 균열 및 붕괴사례가 빈번히 발생하여 안전에 대한 중요성이 대두되고 있다. 이러한 붕괴원인은 곡선부에 대한 연구 부족과 설계기준의 미흡, 경제성과 공기단축에 의한 시공성 결여, 충분하지 못한 다짐 공간 등에 있다고 할 수 있다. 이에 본 연구에서는 기존 설계 및 시공 기준을 검토하고 블록형 보강토옹벽 곡선부 사고사례를 통해 원인을 분석하였으며, 실제 시공된 블록형 보강토옹벽의 현장계측을 통해 직선부와 곡선부의 거동을 비교 분석하고 곡선부 보강영역의 변형특성을 확인하였다. 그 결과, 먼저 곡선부의 수평변위가 직선부와 비교하여 볼록형에서 최대 90%, 오목형에서 최대 60% 높게 나타났으며, 다음으로 곡선부 보강영역에서 볼록형의 경우 보강토옹벽 중심에서 수평방향으로 H/2구간에서 최대변위를 보이며 H까지의 영향범위를 나타내었으며, 오목형의 경우 중심에서 최대변위를 보이며 수평방향으로 H/4구간에서 최소변위를 확인하였다. 이러한 결과로 형태에 따른 곡선부의 영향범위와 현장적용을 위한 보강영역의 재정립이 필요하다고 판단되며, 본 연구결과가 이를 위한 기초 자료로서 활용 가능할 것으로 판단된다.

Fenton Reaction을 이용한 Phenanthrene 오염 토양 처리에서 Acetate의 영향 (Influence of Acetate on the Removal of Phenanthrene from Contaminated Soil using Fenton Reaction)

  • 성요셉;박주양
    • 대한환경공학회지
    • /
    • 제31권5호
    • /
    • pp.352-357
    • /
    • 2009
  • 오염토양에 펜톤 반응을 적용함에 있어서 과산화수소의 빠른 소모로 과량의 과산화수소가 요구되어지는 것이 단점으로 지적되고 있다. 이에 본 연구에서는 대표적인 PAHs물질인 phenanthrene으로 오염된 토양 처리를 위해 철의 리간드로 acetate를 사용하여 과산화수소의 안정성 확보를 통하여 공정의 효율을 높이고자 하였다. Acetate는 철의 몰농도에 대비하여 0.5배에서 3배(2${\sim}$12 mM)까지 주입하였고, 과산화수소는 분해 효율에 미치는 영향을 배제하기 위해 낮은 농도인 0.7%를 주입하였다. Acetate가 주입되어 과산화수소의 잔류시간은 최대 50배 이상 증가하였으며, 과산화수소의 안정성이 확보됨에 따라 phenanthrene의 제거율도 70%까지 향상되었다. 반응 중에 철은 2가와 3가로 산화환원을 반복하였고 과산화수소가 모두 분해되는 시점부터 $HO_2^-$에 의해 2가철로 환원이 이루어졌다. 과산화수소의 영향으로 반응중의 pH는 산성영역을 나타냈으며, acetate가 8 mM 이상 주입되었을때 4${\sim}$5범위 내에 머무르는 것을 확인하였다. Fenton reaction에 의해 철의 리간드로 사용된 acetate 역시 분해가 이루어지는 것을 확인할 수 있었으며, phenanthrene의 비해 분해되는 시점이 느린 것으로 나타나 분해되어지는 경쟁관계에서 phenanthrene이 우세한 것으로 판단된다. 이상의 연구결과를 통해 오염 토양처리에 기존 Fenton reaction의 효율성과 경제성을 향상시킬 수 있는 가능성을 확인할 수 있었으며, 중성영역의 pH로 확장된 연구 등을 통해 좀 더 현실적인 공법으로 발전할 수 있으리라 판단된다.