• Title/Summary/Keyword: Stabilization Device

Search Result 140, Processing Time 0.03 seconds

Core muscle Strengthening Effect During Spine Stabilization Exercise

  • Han, Kap-Soo;Nam, Hyun Do;Kim, Kyungho
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2413-2419
    • /
    • 2015
  • Core spinal muscles are related to trunk stability and assume the main role of stabilizing the spine during daily activities; strengthening of core muscles around the spine can therefore reduce the chance of back pain. The objective of the study was to investigate the effect of core muscle strengthening in the spine during spine stabilization exercise using a whole body tilt device. To achieve this, a validated musculoskeletal (MS) model of the whole body was used to replicate the input motion from the whole body tilting exercise. An inverse dynamics analysis was executed to estimate spine loads and muscle forces depending on the tilting angles of the exercise device. The activation of long and superficial back muscles such as the erector spinae (iliocostalis and longissimus) were mainly affected by the forward direction (-40°) of the tilt, while the front muscles (psoas major, quadratus lumborum, and external and internal obliques) were mainly affected by the backward tilting direction (40°). Deep muscles such as the multifidi and short muscles were activated in most directions of the rotation and tilt. The backward directions of the tilt using this device could be carefully applied for the elderly and for rehabilitation patients who are expected to have less muscle strength. In this study, it was shown that the spine stabilization exercise device can provide considerable muscle exercise effect.

A Study on the Vibration Characteristics of Camera Module for Aerial Reconnaissance Considering Vibration Isolator (방진을 고려한 항공 정찰용 카메라 모듈부의 진동특성에 관한 연구)

  • Lee, Sang-Eun;Lee, Tae-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.5
    • /
    • pp.545-553
    • /
    • 2012
  • A Gimbal structure system in observation reconnaissance aircraft is made up of camera module and stabilization drive device supporting camera module. During flight for image recording, the aircraft undergoes serious accelerations with wide frequencies due to several factors. Though base excitation of stabilization drive device induces vibration of camera module, it must get the stable and clean images. To achieve this aim, acceleration of camera module must be reduced. Hence, vibration isolators were installed to stabilization drive device. Considering isolators and bearings in the stabilization drive device, vibration characteristics of gimbal structure system were analyzed by finite element method. For three translational direction, acceleration transmissibility of camera module was calculated by harmonic responses analysis in the frequency range of 5 ~ 500 Hz. In addition to, sine-sweep experiment were performed to prove correctness of present analysis.

The Effect of Five Different Trunk Stabilization Exercise on Thickness of Abdominal Muscle Using an Ultrasonography Imaging in Normal People (정상인에서 5가지 체간 안정화 운동자세가 초음파 영상을 이용한 복부근 두께에 미치는 영향)

  • Kang, Jung-Hyun;Shim, Jae-Hun;Chon, Seung-Chul
    • Physical Therapy Korea
    • /
    • v.19 no.3
    • /
    • pp.1-10
    • /
    • 2012
  • The aim of this study is to compare measurements of abdominal muscle thickness using ultrasonography imaging (USI) to those using a special transducer head device, during five different trunk stabilization exercises, ultimately to determine which exercise led to the greatest muscle thickness. Thirty eight healthy subjects participated in this cross-sectional study. The five types of trunk stabilization - i.e., a sit-up on the supine, an upper and lower extremity raise with quadruped on the prone, a leg raise in sitting on the ball, trunk rolling on the ball, and balance using sling on the prone position - were each performed with an abdominal draw. The thickness of the abdominal muscle - including the transverse abdominal (TrA), internal oblique (IO), and external oblique (EO) - was measured by USI with a special transducer head device, at rest and then at contraction in each position. Data were analyzed using one-way repeated ANOVA with the level of significance set at ${\alpha}$=.05. The results were as follows: 1) the TrA thickness was statistically significant (p<.05), whereas the IO and EO thicknesses were not (p>.05); 2) among the five types of trunk stabilization, TrA thickness significantly increased with the balance using a sling in the prone position, (p<.05), whereas no significant difference was noted for the four types of trunk stabilization (p>.05); 3) reliability data showed that there was a high degree of consistency among the measurements taken using the special transducer head device (ICC=.92). In conclusion, the balance using a sling in the prone position was more effective than any of the four other types of trunk stabilization in increasing TrA thickness in healthy subjects.

Effect of Spine Stabilization Exercise Device on Core spine muscles (자세균형 재활운동기기의 척추 중심근육에 미치는 영향 해석)

  • Han, Kap-Soo;Kim, Kyungho;Ko, Myoung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1425-1426
    • /
    • 2015
  • Core spine muscle are related are associated with trunk stability and play a main role for the prevention of low back pain. In this study, it was investigated the effect of spine stabilization exercise device on core spinal muscles using a musculoskeletal model The forward direction of the tilt mainly induced the activation of long and superficial back muscles and the backward affected the front muscles. It was shown that spine stabilization exercise device can induce significant core muscle exercise effect.

  • PDF

Influence of Difficulty Variation of the Core Stabilization Exercise on Thickness Changes of Abdominal Muscles in Healthy Subjects: A Pilot Study

  • Kang, Jeong-Hyeon;Suh, Hye-Rim;Kim, Chang-Yong;Kim, Hyeong-Dong;Kim, Hyungkun
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.2
    • /
    • pp.112-118
    • /
    • 2016
  • Purpose: This study examined thickness changes in abdominal muscles according to difficulty level of core stabilization exercise in healthy subjects. Methods: Thirty healthy subjects (age range: 21-30 years) volunteered under three conditions. In the first condition, the subjects performed an abdominal draw-in maneuver (ADIM). In the second condition, they performed the ADIM during quadruped exercise using a suspension device without extending their lower limbs. In the third condition, the subjects performed the ADIM during quadruped exercise using a suspension device while extending both lower limbs. The changes in thickness of transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles were measured by ultrasonography (US) imaging during the three experimental conditions, and US was used to measure the improvement ratio of muscle thickness at rest. The interventions were conducted over three trials in each condition, and measurements were performed on each subject by one examiner. Results: Our results showed a significantly greater increase in the muscle thickness of TrA and IO muscles after performance of quadruped exercise using a suspension device without knee extension (p<0.05) compared to the other conditions. The results also showed a significantly greater increase in the thickness changes of EO muscle in those who performed the ADIM during quadruped exercise using a suspension device with knee extension (p<0.05) compared with the ADIM only. Conclusion: These findings demonstrated positive evidence that a low-level core stabilization exercise could improve thickness of abdominal muscles.

Realization of Optically Compensated Bend State using Surface Polymer Stabilization

  • Jeon, E.J.;Kang, B.G.;Kwon, D.W.;Lim, Y.J.;Lee, M.H.;Lee, S.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.657-660
    • /
    • 2009
  • Optically compensated bend (OCB) mode has intrinsic characteristics such as wide viewing angle and fast response time. However, in order to operate the OCB mode in bend state, this device needs quick transitions from the initial splay state to bend state. In this paper, we proposed OCB mode with initially bend state using reactive mesogen (RM) monomer for surface polymer stabilization. The device shows continuous reorientation of the LC with applied field and a very fast response time.

  • PDF

Development of Brace-type Wearable Robot for Lumbar Stabilization (요부 안정화를 위한 복대형 입는 로봇 개발)

  • Joowan Kim;Jaehoon Sim;Keewon Kim;Sungun Chung;Jaeheung Park
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.2
    • /
    • pp.189-196
    • /
    • 2023
  • An abdominal brace is a recommended treatment for patients with lumbar spinal disorders. However, due to the nature of the static brace, it uniformly compresses the lumbar region, which can weaken the lumbar muscles or create a psychological dependence that worsens the condition of the spine when worn for an extended period of time. Due to these issues, doctors limit the wearing time when prescribing it to patients. In this paper, we propose a device that can dynamically provide abdominal pressure and support according to the lumbar motion. The proposed device is a wearable robot in the form of a brace, with actuators and a driving unit mounted on the brace. To enhance wearability and reduce the weight of the device, worm gears actuator and a multi-pulley mechanism were adopted. Based on the spinal motion of the wearer measured by the Inertia measurement unit sensors, the drives wire by driving pulley, which provide tension to the multi-pulley mechanism on both sides, dynamically tightening or loosening the device. Finally, the device can dynamically provide abdominal pressure and support. We describe the hardware and system configuration of the device and demonstrate its potential through basic control experiments.

A Study on Determination of PID Coefficients by Deriving Temperature Stabilization Transfer Function and it's Simulation (온도 안정화 전달함수 도출 및 이의 시뮬레이션에 의한 PID 계수 결정에 관한 연구)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.412-418
    • /
    • 2015
  • In this paper, a new method for obtaining PID coefficients which are essential to a temperature stabilization process has been proposed. This method starts from measuring the open loop transfer function of the module, then the closed loop transfer function embodying PID control can be produced based on this. Finally, the simulations using a few PID coefficients and the performance analysis for those results provide the best PID coefficients which are effective in a fast setting to a target temperature, a less current needed, and less deviation from steady state. The measurement using the derived PID coefficients, $K_p=1.6$,$K_i=0.8$,$K_d=0.3$ showed $T_s=7.4[sec]$, %OS = 16, and stabilization within ${\pm}0.02[^{\circ}C]$ for several hours. In addition to light sources like SOA, the proposed method can be utilized for any device needs temperature stabilization.

Control of Focal Plane Compensation Device for Image Stabilization of Small Satellite Camera (소형 위성 카메라의 영상안정화를 위한 초점면부 보정장치의 제어)

  • Kang, Myoungsoo;Hwang, Jaihyuk;Bae, Jaesung
    • Journal of Aerospace System Engineering
    • /
    • v.10 no.1
    • /
    • pp.86-94
    • /
    • 2016
  • In this paper, position control of focal plane compensation device using piezoelectric actuator is conducted. The forcal plane compensation device installed on earth observation satellite camera compensates micro-vibration from reaction wheels. In this study, four experimental models of the open-loop compensation device are derived using MATLAB system identification toolbox in the input range of 0~50Hz. Subsequently, the PID controller for each model is designed and the performance test of each controller is conducted through MATLAB/Simulink. According to frequency response analysis of the closed-loop compensation device system, the PID controller designed for 38~50Hz input range has enough tracking performance for the whole 0~50Hz input range. The maximum output error is about $1{\mu}m$ for the input range. The simulation results has been verified by the experimental method.

Using MZIs for Optical PSBT Transmissions: Requirements for Thermal Stabilization

  • Ducournau, Guillaume;Latry, Olivier;Ketata, Mohamed
    • ETRI Journal
    • /
    • v.28 no.5
    • /
    • pp.615-620
    • /
    • 2006
  • In this paper, we discuss the quantification of Mach-Zehnder interferometer (MZI) thermal stabilization which is needed in optical phase shaped binary transmission (PSBT) links. Considering the thermo-optic and thermal expansion effects, we revisit the analytical expression for the thermal drift (GHz/$^{\circ}C$) of the MZI center frequency (denoted here by the 'MZI spectral drift'). An MZI is then used in an experimental transmission system using the optical PSBT format. We study the effect of spectral MZI drift by using a thermally stabilized interferometer and applying a frequency shift to the optical carrier. By using the thermal drift coefficient of the MZI, we find that to ensure low bit error rate fluctuations due to the MZI drift, the thermal stabilization of the device must have an accuracy of $0.5^{\circ}C$.

  • PDF