• Title/Summary/Keyword: Stabilization Control

Search Result 1,253, Processing Time 0.033 seconds

Reducing the Harmonics of Static Var Compensator Using Multi-Step Inverter (멀티-스텝 인버터를 이용한 무효전력 보상장치의 고조파 저감)

  • Park, Hyun-Chul;Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.19-22
    • /
    • 2001
  • For stabilization and improving power factor in the power lines, various Static Var Compensators(SVC) have been considered to be installed and partly applicated already. With all these merits of the SVC, it stil has demerits, principally evoking harmonic problems. So far, many harmonic reduction type inverters have been used in various parts. In this paper, the reactive power is controlled by amplitude of the output voltage. This paper propose that the multiple voltage source inverter have controllable power factor made by load vary at receive-stage as lagging and leakage control. The theoretical analysis on this system was confirmed through the computer simulation and the experiments.

  • PDF

Design of the Robust Controller for the Discrete-Time Nonlinear System with Time-Delay Via Fuzzy Approach (퍼지 기법을 이용한 시간 지연을 가지는 이산시간 비선형 시스템에 대한 강인 제어기 설계)

  • Kim, Taek-Ryong;Park, Jin-Bae;Joo, Young-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2723-2725
    • /
    • 2005
  • In this paper, a robust $H{\infty}$ stabilization problem to a uncertain discrete-time nonlinear systems with time-delay via fuzzy static output feedback is investigated. The Takagi-Sugeno (T-S) fuzzy model is employed to represent an uncertain nonlinear systems with time-delayed state. Then parallel distributed compensation technique is used for designing of the robust fuzzy controller. Using a single Lyapunov function, the globally asymptotic stability and disturbance attenuation of the closed-loop fuzzy control system are discussed. Sufficient conditions for the existence of robust $H{\infty}$ controllers are given in terms of linear matrix inequalities via similarity transform and congruence transform technique.

  • PDF

Model development for chlorine generation using electrolysis (전기분해에 의한 잔류염소 생성 예측 모델 개발)

  • Sohn, Jinsik;Lee, Sunjae;Shin, Chorong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.331-337
    • /
    • 2009
  • Electrolysis produces hypochlorous acid by using a small quantity of NaCl as electrolyte. This process maximizes the stabilization of drinking water through the control of chlorine residual concentration. This study investigated free chlorine generation by an electrolytic method using $Ti/IrO_2$ and stainless steel. The generation of free chlorine was increased with increasing hydraulic retention time, voltage, chlorine ion concentration and the number of electrodes. However, the change of pH did not affect the generation of free chlorine. There was no significant difference on the behavior of chlorine concentration between electrolytic method and NaOCl injection. In this study, the concentration of free chlorine predicted model based on power functional model was developed various under conditions. Electrolysis free chlorine generation model can be effective tool in the estimation of free chlorine generation.

Geotechnical behavior of a beta-1,3/1,6-glucan biopolymer-treated residual soil

  • Chang, Ilhan;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • v.7 no.6
    • /
    • pp.633-647
    • /
    • 2014
  • Biopolymers, polymers produced by living organisms, are used in various fields (e.g., medical, food, cosmetic, medicine) due to their beneficial properties. Recently, biopolymers have been used for control of soil erosion, stabilization of aggregate, and to enhance drilling. However, the inter-particle behavior of such polymers on soil behavior are poorly understood. In this study, an artificial biopolymer (${\beta}$-1,3/1,6-glucan) was used as an engineered soil additive for Korean residual soil (i.e., hwangtoh). The geotechnical behavior of the Korean residual soil, after treatment with ${\beta}$-1,3/1,6-glucan, were measured through a series of laboratory approaches and then analyzed. As the biopolymer content in soil increased, so did its compactibility, Atterberg limits, plasticity index, swelling index, and shear modulus. However, the treatment had no effect on the compressional stiffness of the residual soil, and the polymer induced bio-clogging of the soil's pore spaces while resulting in a decrease in hydraulic conductivity.

Performance improvement of SOC indicator for electric vehicle using hydrometer (온-라인 비중계를 이용한 전기자동차용 바테리 잔존용량계의 성능개선)

  • 박종건;임영철;박철수;류영재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.423-426
    • /
    • 1996
  • The conditions to be satisfied with SOC(State-of-Charge) indicator installed on the electric vehicle were that it should be used under frequent loading conditions and that it should enable the monitor to adjust to the aging effect. But, the state-of-charge test requires a lengthy stabilization period after discharge cycles and the ampere-hour test requires the knowledge of the battery capacity in terms of amp-hours. However, a monitoring technique combining the state-of-charge test to enable the monitor to adjust to the aging effect with the ampere-hour test to use under frequent loading condition is studied and implemented on a microcontroller-based circuit in this paper. Specially, optical fiber is used to realize hydrometer which is immune to electromagnetic interference and toxic environment and makes it possible to be used in a wide temperature range.

  • PDF

Neuro-genetic controller design of the line of sight system (유전알고리듬에 의한 조준경 시스템의 신경망제어기 설계)

  • 이승수;장준오;전기준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.956-959
    • /
    • 1996
  • In this study, we propose a neuro-genetic controller combined with a linear controller in parallel to improve the tracking performance of the Line of Sight(LOS) stabilization system and reject the effect of disturbances. A Genetic Algorithm(GA) is used to optimize weights of the neuro-genetic controller since this algorithm can search a global minimum without derivatives or other auxiliary knowledge. The LOS system is very complex and has limited measurable output data. Under these specific circumstances GA solves many problems that other training methods have. Computer simulation results show that the, proposed controller makes better tracking response and rejection of disturbance than a linear controller.

  • PDF

Stabilization of Co Semigroups in infinite dimensional systems by a compact linear feedback via the steady state Riccati equation

  • Park, Dong-Jo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.729-733
    • /
    • 1987
  • Stability of Co Semigroups perturbed via the steady state Riccati equation (SSRE) is studied. We consider an infinite dimensional system : .chi. over dot = A.chi. + Bu, in, (A), domain of A, where A is the infinitesimal generator of a Co semigroup [T(t), t.geq.0] in H. If the original Co semigroup [T(t), t.geq.0] has a lower bound : vertical bar T(t).chi. vertical bar .geq. k vertical bar .chi. vertical bar, for all .chi. in H. t.geq. 0 and k>0, then the perturbed Co semigroup via the SSRE, where the feedback operator B is compact, cannot be exponentially stable. Physical interpretation of this result is as follows : in real applications, a finite number of actuators are available, therefore the operator B is compact. When the original system is inherently unstable, that is, has an infinite number of unstable modes, the perturbed system via the SSRE cannot be stable with a uniform decay rate.

  • PDF

Stabilization of Body Bias Control in SOI Devices by Adopting Si Film Island (SOI 소자에서의 바디 전압 안정화를 위한 실리콘 필름 Island 구조)

  • Chung, In-Young;Lee, Jong-Ho;Park, Young-June;Min, Hong-Shick
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.100-106
    • /
    • 1999
  • A new IBC(Island Body Contact) structure is introduced to SOI CMOS VLSI for stabilizing the body potential of the MOSFET without the additional area consumption. The improvement of the body contact effect is achieved by reducing the body resistance and the area is saved as the bodies of the MOSFETs are connected together. Its property as VLSI device is confirmed through the device simulations and the measurement.

  • PDF

A Study on the Control of Characteristic in the Analog Active Element for System Stabilization (시스템 안정화를 위한 아날로그 능동 소자의 특성 제어에 관한 연구)

  • Lee, Geun Ho;Bang, Jun Ho;Kim, Dong Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.6B
    • /
    • pp.114-114
    • /
    • 2000
  • In this paper, a current comparative frequency automatic tuning circuit for the CMOS bandpass filter are designed with the new architecture. And also, when the designed circuit is compared the typical tuning circuit, it has very simple architecture that is composed of the current comparator and charge pump and operated in 2V power supply. The proposed tuning circuit automatically compensate the difference between the operating current of the integrator and the reference current which is specified. Using CMOS 0.25um parameter, a CMOS bandpass active filter with center frequency(f0= 100MHz) is designed, and according to the transister size the variation of the center frequency is simulated. As the HSPIC simulation results, the tuning operating of the proposed current comparative frequency automatic tuning circuit is verified.

Remote On-line Determination of the Load Rate Limit of Generation in AGC (AGC 운용에 있어서의 원격 On-line 최대 증감발율 취득 기법)

  • Kwon, Soon-Man;Jeon, Dong-Hoon;Moon, Won-Yong;Kim, Suk-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.119-121
    • /
    • 2000
  • The possibility of a remote on-line determination of the maximum load rates that are basically set at generation plants is investigated in automatic generation control (AGC) system. Energy management system (EMS) generates a test input to a remote power plant to get the samples of the generator output. Then from the samples it can be attempted to determine an approximate value of the load rate limit set by the operator. It is shown in computer simulation that in actual power plants the limit can be approximately determined from the input-output characteristics of the plants for a unit-step input.

  • PDF