• 제목/요약/키워드: Square hot body

검색결과 20건 처리시간 0.024초

정사각형 밀폐공간 내에 있는 고온부로부터의 자연대류 열전달 (Natural Convection Heat Transfer from a Hot Body in s Square Enclosure)

  • 권순석;정태현;권용일
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.147-154
    • /
    • 1992
  • Laminar natural convection heat transfer from a hot body in a square enclosure has been studied for various center positions of a hot square at Grashof number $Gr=1.5{\times}10^5$, Prandtl number Pr=0.71 and dimensionless thermal conductivity $k_g/k_f=14710$. The natural convection at the center position of a hot square; $X_c$, $Y_c=0.5$, 0.2 shows the most strong and at $X_c$, $Y_c=0.5$, 0.7 the most weak. The total mean Nusselt number at $X_c$, $Y_c=0.5$, 0.2 was 7.4% higher than that at $X_c$, $Y_c=0.2$, 0.5. The total mean Nusselt number at $X_c$, $Y_c=0.5$, 0.7 was 5.0% lower than that at $X_c$, $Y_c=0.3$, 0.5.

  • PDF

온천이 소아의 체성분과 자율 신경 기능에 미치는 영향에 관한 연구 (The Effect of Balneotherapy on Children Autonomic Nervous System Function and Body Composition)

  • 조민서;이남헌;한재경
    • 대한한방소아과학회지
    • /
    • 제25권3호
    • /
    • pp.77-84
    • /
    • 2011
  • Objectives: This study was performed to investigate the effect of hot spring therapy on children weight, body composition and heart rate variability. Methods: The study was carried out from 30 children who visited the spa from August 1, 2011 to August 31, 2011. We measured the change of weight, body composition, and heart rate variability after hot spring therapy for an hour per day. Results: The subject was consisted of 13 boys and 17 girls. This study revealed that their weight got lost from a hot spring therapy, which was statistically significant. Their body mass index(BMI) was decreased in from a hot spring therapy, which was not statistically significant. Total body water, muscle, protein, and mineral were decreased from a hot spring therapy, which was statistically significant. We measured HRV(heart rate variability) before and after the hot spring therapy. The mean HRT was increased, which was statistically insignificant. SDNN(standard deviation of the NN interval) and RMSSD(square root of the mean of the sum of the square of differences) were not different before and after the hot spring therapy. ln TP was decreased insignificantly. ln VLF was not affected before and after hot spring therapy. ln LF and ln HF was decreased, LF norm was increased, and HF norm was decreased, which were not statistically significant. Also, LF/HF ratio was increased insignificantly. Conclusions: From these results, we concluded that the weight, total body water, muscle, protein, and mineral got lost from the hot spring therapy. However, the HRV was not affected from the hot spring therapy.

다른 경계조건을 갖는 밀폐공간 내에 존재하는 고온부로부터의 자연대류 열전달 (Natural convection heat transfer from a hot body in the square enclosure with different boundary conditions)

  • 권순석;정태현;권용일
    • 대한기계학회논문집
    • /
    • 제16권12호
    • /
    • pp.2395-2406
    • /
    • 1992
  • 본 연구에서는 방으로부터의 열손실 및 특수공간 내에서의 열전달에 응용할 수 있는 자료를 얻기 위하여 고온부가 존재하는 밀폐공간 내의 자연대류 열전달을 밀 폐공간의 경계조건을 좌,우측이 저온벽면이고 상,하면이 단열인 경우와 좌,우측이 단 열벽면이고 상,하면이 저온인 경우에 있어서 고온부의 중심 위치 X$_{c}$,Y$_{c}$를 수평으로 X$_{c}$,Y$_{c}$=0.2~0.5, 0.5 그리고 수직으로 X$_{c}$,Y$_{c}$=0.5, 0.2 ~0.5, 0.8까지 이동하여 수치해석하였고 실험과 비교 고찰하였다.

경사진 정사각형 밀폐공간 내에 있는 고온부로부터의 자연대류 열전달 (Natural Convection Heat Transfer from a Hot Body in an Inclined Square Enclosure)

  • 권순석;정태현
    • 태양에너지
    • /
    • 제12권1호
    • /
    • pp.25-33
    • /
    • 1992
  • 정상상태에서 고온부가 존재하는 밀폐공간내의 자연대류 열전달을 $Gr=1.5{\times}10^5$, Pr=0.71 및 $k_s/k_f=14710$ 조건에서 경사각을 변화시켜 연구하였다. 고온부는 밀폐공간 면적의 1/25 을 차지하고 형상비는 1.0이다. 전체평균 누셀트 수는 경사각을 증가시키면 감소하였고 ${\theta}=90^{\circ}$인 경우가 ${\theta}=0^{\circ}$ 일때보다 14% 낮게 나타났다.

  • PDF

Theoretical Analysis on the Hot Surface Ignition of a Rectangular-Shape Solid Fuel

  • Kim, Se-Won
    • 에너지공학
    • /
    • 제4권2호
    • /
    • pp.297-302
    • /
    • 1995
  • Ignition of a reactive solid in a shape of square corner by a hot surface is studied theoretically. Ignition time and the location of ignition point are determined as a function of dimensionless parameters, with the use of the homogeneous model of ignition. The effect of geometry on the ignition of solid fuel results in the local characteristics: the reaction is initiated in a hot point in depth of the substance. It is shown that ignition time is proportional to the dimensionless initial temperature, whereas for the ignition of the semiinfinite body this dependence was quadratic.

  • PDF

Measurement of Developing Turbulent Flows in a 90-Degree Square Bend with Spanwise Rotation

  • Choi Young Don;Kim Dong Chul;Lee Kun Hee
    • Journal of Mechanical Science and Technology
    • /
    • 제19권7호
    • /
    • pp.1503-1516
    • /
    • 2005
  • Mean flow and turbulence properties of developing turbulent flows in a 90 degree square bend with span-wise rotation are measured by a hot-wire anemometer. A slanted wire is rotated into 6 orientations and the voltage outputs from them are combined to obtain the mean velocity and the Reynolds stress components. Combined effects of the centrifugal and Coriolis forces due to the curvature and the rotation of the bend on the mean motion and turbulence structures are investigated experimentally. Results show that the two body forces can either enhance or counteract each other depending on the flow direction in the bend.

실내화재에 있어서의 대류열전달에 관한 수치연구 - I. 수치법 검증과 자연대류- (Numerical Study on Convective Heat Transfer in a Compartment Fire - I. Evaluation of Numerical Method and Natural Convection-)

  • 박외철;고경찬
    • 한국안전학회지
    • /
    • 제14권2호
    • /
    • pp.26-31
    • /
    • 1999
  • In a compartment fire, convective heat transfer dominates spread of the fire and smoke movement before flash-over occurs, and natural convection is very important in particular when there are no openings. The finite volume method with SIMPLE algorithm was applied to a square cavity similar to a compartment without an opening. The objectives of this study are to evaluate the method and to simulate natural convection from a hot body in the cavity. The results without the hot body showed an excellent agreement with those of previous studies. Streamlines, isotherms and Nusselt numbers were computed for different Rayleigh numbers.

  • PDF

Two-color LIF 기법을 이용한 단열체가 있는 밀페계 내에서의 자연대류에 관한 실험적 연구 (Experimental Study on the Natural Convection in an Enclosure with an Adiabatic Body Using the Two-Color LIF Method)

  • 권수현;정은호;민영욱;김경천
    • 한국가시화정보학회지
    • /
    • 제3권1호
    • /
    • pp.90-96
    • /
    • 2005
  • Most of the previous studies on natural convection were based on the numerical analysis, and some experimental studies considered the classic case of thermal convection. In this study, an adiabatic square body was located at the center of an enclosure between the bottom hot and top cold walls. And the measurement of the detailed temperature fields was conducted by the method of two-color Laser Induced Fluorescence using a Nd:Yag laser. As a result, heat transfer characteristics of natural convection with an adiabatic body was estimated as a function of time over a range of Rayleigh numbers.

  • PDF

Two-color LIF 기법을 이용한 단열체가 있는 밀폐계 내에서의 자연대류에 관한 실험적 연구 (Experimental study on the natural convection in an enclosure with an adiabatic body using the two-color LIF method)

  • 권수현;정은호;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.104-107
    • /
    • 2004
  • Most of the previous studies on natural convection were based on the numerical analysis, and some experimental studies considered the classic case of thermal convection. In this study, an adiabatic square body was located at the center of an enclosure between the bottom hot and top cold walls. And the measurement of the detailed temperature fields was conducted by the method of two-color Laser Induced Fluorescence using a Nd:Yag laser. As a result, heat transfer characteristics of natural convection with an adiabatic body was estimated as a function of time over a range of Rayleigh numbers.

  • PDF

횡방향으로 회전하는 90도 정사각 단면 곡덕트에서 발달하는 난류유동의 측정 (Measurement of Developing Turbulent Flows in a 90-Degree Square Bend with Spanwise Rotation)

  • 김동철;최영돈;이건휘
    • 대한기계학회논문집B
    • /
    • 제27권2호
    • /
    • pp.206-214
    • /
    • 2003
  • Mean flow and turbulence properties of developing turbulent flows in a 90 degree square bend with spanwise rotation were measured by a hot-wire anemometer. A slanted wire is rotated into 6 orientations and the voltage outputs from them are combined to obtain the mean velocity and Reynolds stress components. The combinative effects of the centrifugal and Coriolis forces due to the curvature and the rotation of bend on the mean motion and turbulence structures are investigated experimentally. Results show that the two body forces can either enhance or counteract each other depending on the flow direction in the bend.