• Title/Summary/Keyword: Square duct

Search Result 174, Processing Time 0.026 seconds

Detailed Measurement of Heat/Mass Transfer in a Rotating Two-Pass Duct (I) - Effects of Rib Tubulators - (이차 냉각 유로를 가진 회전덕트에서 열/물질전달 특성 (I) - 요철 설치에 따른 영향 -)

  • Kim, Kyung-Min;Kim, Sang-In;Kim, Yun-Young;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.910-920
    • /
    • 2004
  • The heat/mass transfer characteristics in a rotating two-pass duct with and without rib turbulators are investigated in the present study. The square duct has a hydraulic diameter ($D_h$) of 26.7 mm, and $1.5\;mm{\times}1.5\;mm$ square $90^{\circ}$-rib turbulators are attached on the leading and trailing walls. The pitch-to-rib height ratio (p/e) is 10. The Reynolds number based on the hydraulic diameter is kept constant at 10,000 to exclude the Reynolds effect, and the rotation number is varied from 0.0 to 0.20. In the smooth duct, the curvature of the $180^{\circ}$-turn produces Dean vortices that enhance heat/mass transfer in the post-turn region. When rib turbulators are installed, heat/mass transfer is augmented 2.5 times higher than that of the smooth duct since the main flow is turbulated by reattaching and separating in the vicinity of the duct surfaces. The duct rotation results in heat/mass transfer discrepancy so that Sherwood number ratios are higher on the trailing surface in the first-pass and on the leading surface in the second-pass. In the turning region, Dean vortices shown in the stationary case transform into one large asymmetric vortex cell, and subsequent heat/mass transfer characteristics also change. As the rotation number increases, the heat/mass transfer discrepancy enlarges.

Effects of Rib Cross Section Shapes on Heat Transfer of a Rib-Roughened Duct (터빈 기익 내부관 열전달 증대를 위해 설치된 요철의 형상 효과)

  • Wu, Seong Je;Kwon, Hyuk Jin;Cho, Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.1
    • /
    • pp.149-157
    • /
    • 1999
  • Heat transfer in a duct is augmented remarkably by rib turbulators. However, increasing friction loss is accompanied due to ribs disturbing flows. Hence, pressure drops and heat transfer are considered simultaneously to decide heat/mass transfer performance in a rib-roughened duct. In the present study, the effects of rib cross section shape on pressure drop through a duct are investigated as well as those on heat transfer characteristics. The results show that the characteristics of heat/mass transfer and friction loss in the duct roughened with triangular ribs are similar to those with square ribs, while significantly different from those with semicircular ribs. The best performance in the duct is obtained by using semicircular shaped ribs among three types of ribs for the large rib angles of ${\alpha}{\geq}63^{\circ}$.

An Experimental Study on Velocity Profiles and Turbulence Intensity of Developing Turbulent Pulsating Flows in the Entrance Region of a Square Duct

  • Park, G.M.;Koh, Y.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.235-242
    • /
    • 1993
  • The flow characteristics of developing turbulent pulsating flows are investigated experimentally in the entrance region of a square duct ($40mm{\times}40mm$ and 4,000mm). Mean velocity profiles, turbulence intensity and entrance length are measured by using a hot-wire anemometer system together with data acquisition and processing systems. It is found that the velocity waveforms are not changed in the fully developed flow region where that $x/Dh{\geq}40$. For turbulent pulsating flow, the turbulent components in the velocity waveforms increase as the dimensionless transverse position approaches the wall. Mean velocity profiles of the turbulent steady flows follow the one-seventh power law profile in the fully developed flow region. Turbulence intensity increases as the dimensionless transverse position increases from the center to the wall of the duct, and is slightly smaller in the accelerating phase than in the decelerating phase for the turbulent pulsating flows. The entrance length of the turbulent pulsating flow is about 40 times as large as the hydraulic diameter under the present experimental conditions.

  • PDF

A Study on the Comparison Between Experimental and Numerical Analysis for Developing Turbulent Steady Flows in the Entrance Region of a Square Duct (정4각덕트의 입구영역에서 난류정상유동의 실험해와 수치해의 비교에 관한 연구)

  • 고영하;박길문;봉태근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.3
    • /
    • pp.236-245
    • /
    • 1997
  • The flow characteristics of developing turbulent steady flow are investigated numerically and experimentally in the entrance region of a square duct ($40 mm{\times}40 mm$ and 4, 000 mm). The numerical anaysis are incorporated by finite- volume discretization with staggered grid system and SIMPLE algorithm. The numerical solution are compared with experimental results of mean velocity profiles, turbulence intensity and entrance length. For turbulent steady flow, the turbulent components in the velocity waveforms increase as the dimensionless transverse position approaches the wall. Thrbulence intensity increases as the dimensionless transverse position increases from the center to the wall of the duct for the developing turbulent steady flows. The entrance length of the turbulent steady flow is about 40 times as large as the hydraulic diameter under the present experimental condition.

  • PDF

Prediction of Fully Developed Turbulent Flow in a Square Duct with Nonlinear Low-Reynolds-Number κ-ε Models (비선형 저레이놀즈수 κ-ε 난류모델에 따른 정사각형 덕트내 완전 발달된 난류유동 예측)

  • Myong, Hyon-Kook,
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.821-827
    • /
    • 2003
  • Fully developed turbulent flow in a square duct is numerically predicted with two nonlinear low-Reynolds-number ${\kappa}-{\varepsilon}$ models. Typical predicted quantities such as axial and secondary velocities, turbulent kinetic energy and Reynolds stresses are compared in detail with each other. It is found that the nonlinear low-Reynolds-number ${\kappa}-{\varepsilon}$ model adopted in a commercial code is unable to predict accurately duct flows involving turbulence-driven secondary motion with the prediction level of secondary flows one order less than that of the experiment.

Turbulent Flow through a Square Straight and Curved Duct with Reynolds Stress Models (정사각 직관과 $180^{\circ}$ 곡관내 난류유동의 레이놀즈응력모형 적용)

  • Chun, Kun-Ho;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.771-776
    • /
    • 2000
  • Fine grid calculations are reported for the developing turbulent flow in a straight duct and a curved duct of square cross-section with a radius of curvature to hydraulic diameter ratio ${\delta}=R_c/H_H=3.357$ and a bend angle of 180 deg. A sequence of modeling refinements is introduced; the replacement of wall function by a fine mesh across the sublayer and a low Reynolds number second moment closure up to the near wall sublayer in which the non-linear return to isotropy model and the cubic-quasi-isotropy model for the pressure strain are adopted; and the introduction of a multiple source model for the exact dissipation rate equation. Each refinement is shown to lead to an appreciable improvement in the agreement between measurement and computation.

  • PDF

Numerical study of flow of Oldroyd-3-Constant fluids in a straight duct with square cross-section

  • Zhang, Mingkan;Shen, Xinrong;Ma, Jianfeng;Zhang, Benzhao
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.2
    • /
    • pp.67-73
    • /
    • 2007
  • A finite volume method (FVM) base on the SIMPLE algorithm as the pressure correction strategy and the traditional staggered mesh is used to investigate steady, fully developed flow of Oldroyd-3-constant fluids through a duct with square cross-section. Both effects of the two viscoelastic material parameters, We and ${\mu}$, on pattern and strength of the secondary flow are investigated. An amusing sixteen vortices pattern of the secondary flow, which has never been reported, is shown in the present work. The reason for the changes of the pattern and strength of the secondary flow is discussed carefully. We found that it is variation of second normal stress difference that causes the changes of the pattern and strength of the secondary flow.

Three Dimmensional Turbulent Flow Analysis in a 90° Square Sectioned Duct with Strong Curvature (사각단면을 갖는 90° 급곡관의 3차원 난류유동 해석)

  • Maeng, J.S.;Lee, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.11-25
    • /
    • 1991
  • The steady, incompressible developing 3-dimensional turblent flow in a square sectioned curved duct has been investigated by using partially-parabolic equation and Finite Analytic Method. The calculation of turbulent flow field is performed using 2-equation K-$\epsilon$ turbulence model, modified wall function, simpler algorithm and numerically generated body fitted coordinates. Iso-mean velocity contours at the various sections are compared with the existing experimental data and elliptic solutions by other authors. In the region of $0^{\circ}<{\theta}<71^{\circ}$, present results agree with the experimental data much better than the elliptic solution for the similar number of grid points. Furthermore, for the same tolerance, the present solution converges four times faster than the elliptic solution.

  • PDF

A Study on Transitional Unsteady Flows in a Square Duct (정4각단면 덕트 내에서 비정상 천이유동에 관한 연구)

  • Park, G.M.;Park, S.J.;Choi, J.H.;Yoo, Y.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.3
    • /
    • pp.252-263
    • /
    • 1989
  • A system of conservation equations for steady, oscillatory and pulsating duct flows are solved analytically by linearizing non-linear convective terms. Analytical solutions of velocity profiles for these flows are obtained in the form of infinite series. The experimental study for the air flow in a square duct ($40mm{\times}40mm$ and 400 mm long) is carried out to measure velocity profiles and other parameters by using a hot-wire anemometer with data acquisition and processing system. Major characteristics of the flows such as the classification of flow patterns, determination of critical Reynolds number and velocity profiles is accomplished from the experismental results.

  • PDF

Numerical Analysis of Turbulent Carbon Dioxide Flow and Heat Transfer under Supercritical State in a Straight Duct with a Square Cross-Section (초임계상태 이산화탄소의 정사각 단면 직덕트 내 난류유동 및 열전달의 전산해석)

  • 최영돈;주광섭;김용찬;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1004-1013
    • /
    • 2002
  • Turbulent carbon dioxide flows and cooling heat transfers under supercritical state in a straight duct with a square cross-section are numerically analyzed employing low Reynolds number $\kappa-\varepsilon$ model and algebraic stress model. The flow is assumed to be (quasi-incompressible. Predicted Nusselt number and friction factor are compared with the experimental data, Blasius correlation for friction factor and Dittus-Boelter correlation for Nusselt number. Computational results for the Fanning's friction factor agree well with the all Rohsenow and Choi's correlation, Liou and Hwang's experimental data and Blasius correlation. The results obtained by algebraic stress model agree more with the Liou and Hwang's experimental data, while the results obtained by low Reynolds number $\kappa-\varepsilon$ model agree more with Blasius correlation. In the computation of Nusselt number, Dittus-Boelter correlation can not exactly fit the computational results. Therefore we propose the new correlation$Nu=0.053Re^{0.73}Pr^{0.4}$for the turbulent cooling heat transfer of carbon dioxide under supercritical state.