• 제목/요약/키워드: Square Rib

검색결과 72건 처리시간 0.024초

이차 냉각 유로를 가진 회전덕트에서 열/물질전달 특성 (I) - 요철 설치에 따른 영향 - (Detailed Measurement of Heat/Mass Transfer in a Rotating Two-Pass Duct (I) - Effects of Rib Tubulators -)

  • 김경민;김상인;김윤영;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제28권8호
    • /
    • pp.910-920
    • /
    • 2004
  • The heat/mass transfer characteristics in a rotating two-pass duct with and without rib turbulators are investigated in the present study. The square duct has a hydraulic diameter ($D_h$) of 26.7 mm, and $1.5\;mm{\times}1.5\;mm$ square $90^{\circ}$-rib turbulators are attached on the leading and trailing walls. The pitch-to-rib height ratio (p/e) is 10. The Reynolds number based on the hydraulic diameter is kept constant at 10,000 to exclude the Reynolds effect, and the rotation number is varied from 0.0 to 0.20. In the smooth duct, the curvature of the $180^{\circ}$-turn produces Dean vortices that enhance heat/mass transfer in the post-turn region. When rib turbulators are installed, heat/mass transfer is augmented 2.5 times higher than that of the smooth duct since the main flow is turbulated by reattaching and separating in the vicinity of the duct surfaces. The duct rotation results in heat/mass transfer discrepancy so that Sherwood number ratios are higher on the trailing surface in the first-pass and on the leading surface in the second-pass. In the turning region, Dean vortices shown in the stationary case transform into one large asymmetric vortex cell, and subsequent heat/mass transfer characteristics also change. As the rotation number increases, the heat/mass transfer discrepancy enlarges.

사각 또는 반원 형상의 요철이 설치된 채널 내부의 유동 및 열전달의 큰에디모사 (Large Eddy Simulation of Flow and Heat Transfer in a Channel Roughened by Square or Semicircle Ribs)

  • 안준;최해천;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1436-1441
    • /
    • 2004
  • The internal cooling passage of a gas turbine blade can be modeled as a ribbed channel. Most studies have considered square ribs. However, the ribs can be rounded due to improper manufacturing or wear during the operation. Hence, we have studied two different rib geometries in this study, i.e. square and semicircle ribs. We have performed large eddy simulations (LES) and experiments to validate the results from the simulations. LES predicts the detailed flow and thermal features, which have not been captured by simulations using turbulence models. By investigating the instantaneous flow and thermal fields, we propose the mechanisms for the local heat transfer distribution between ribs. For both the geometries, heat transfer is enhanced by the entrainment of the cold fluid by the vortical motions and impingement of the entrained cold fluid on the ribs.

  • PDF

An Experimental Studies on Heat Transfer and Friction Factor in a Square Channel with Varying Number of Ribbed Walls

  • Oh Se-Kyung;Kim Won-Cheol;Ahn Soo-Whan;Kang Ho-Keun;Kim Myoung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.281-289
    • /
    • 2005
  • An experimental study on the heat transfer and friction characteristics of a fully developed turbulent air flow in a square channel with $45^{\circ}$ inclined ribs on one, two, and four walls is reported. Tests were performed for Reynolds number ranging from 7,600 to 24,900. The pitch-to-rib height ratio, p/e, was kept at 8 and rib height-to-channel hydraulic diameter ratio, $e/D_h$, was kept at 0.0667. The heat transfer coefficient and friction factor values were enhanced with the increase in the number of ribbed walls. Results of this investigation could be used in various applications of internal channel turbulent flows involving different number of roughened walls.

Characteristics of Heat Transfer in the Channel with Twisted Tape

  • Ahn, Soo-Whan;Kang, Ho-Keun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.122-128
    • /
    • 2007
  • Heat transfer distributions and friction factors in square channels (3.0 ${\times}$ 3.0 cm) with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. The rib height-to-channel hydraulic diameter ratio, $e/D_h$, is kept at 0.067 and test section length-to-hydraulic diameter ratio, $L/D_h$ is 30. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. The twisted tape is 0.1 mm thick carbon steel sheet with diameter of 2.8 cm, length of 90 cm, and 2.5 turns. Two heating conditions are investigated for test channels with twisted tape inserts and rib turbulators: (1) electric heat uniformly applied to four side walls of the square duct, and (2) electric heat uniformly applied to two opposite ribbed walls of the square channel. Results show that the twisted tape with interrupted ribs provides a higher overall heat transfer performance over the twisted tape with no ribs.

90° 요철이 설치된 정사각 덕트 내 압력강하에 곡관부 및 회전이 미치는 영향 (Influence of Turning Region and Channel Rotation on Pressure Drop in a Square Channel with Transverse Ribs)

  • 김경민;이동현;조형희
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.126-135
    • /
    • 2006
  • The pressure drop characteristics in a rotating two-pass duct with rib turbulators are investigated in the present study. The square duct has a hydraulic diameter $(D_h)$ of 26.7 mm, and $1.5mm{\times}1.5mm$ square $90^{\circ}-rib$ turbulators are attached on the leading and trailing walls. The pitch-to-rib height ratio (p/e) is 10. The distance between the tip of the divider and the outer wall of the duct is $1.0D_h$ and the width of divider wall is 6.0mm or $0.225D_h$. The Reynolds number (Re) based on the hydraulic diameter is kept constant at 10,000 to exclude the Reynolds effect, and the rotation number (Ro) is varied from 0.0 to 0.20. The pressure drop distribution, the friction factor and thermal performance are presented for the leading, trailing and the outer surfaces. It is found that the curvature of the $180^{\circ}$-turn produces Dean vortices that cause high pressure drop in the turn. The channel rotation results in pressure drop discrepancy between leading and trailing surfaces so that non-dimensional pressure drops are higher on the trailing surface in the first-pass and on the leading and side surfaces in the second-pass. In the turning region, Dean vortices shown in the stationary case transform into one large asymmetric vortex cell, and subsequent pressure drop characteristics also change. As the rotation number increases, the pressure drop discrepancy enlarges.

초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 요철이 설치된 유출면에서의 열/물질전달 특성 (Heat/Mass Transfer Characteristics on Rib-roughened Surface for Impingement/Effusion Cooling System with Initial Crossflow)

  • 이동호;남용우;조형희
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.338-348
    • /
    • 2004
  • The present study is conducted to investigate the effect of rib arrangements on an impingement/effusion cooling system with initial crossflow. To simulate the impingement/effusion cooling system, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of tile hole diameter. Initial crossflow passes between the injection and effusion plates, and the square ribs (3mm) are installed on the effusion plate. Both the injection and effusion hole diameters are 10mmand Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effects of rib arrangements, various rib arrangements, such as 90$^{\circ}$transverse and 45$^{\circ}$angled rib arrangements, are used. Also, the effects of flow rate ratio of crossflow to impinging jets are investigated. With the initial crossflow, locally low transfer regions are formed because the wall jets are swept away, and level of heat transfer rate get decreased with increasing flow rate of crossflow. When the ribs are installed on the effusion plate, the local distributions of heat/mass transfer coefficients around the effusion holes are changed. The local heat/mass transfer around the stagnation regions and the effusion holes are affected by the rib positions, angle of attack and rib spacing. For low blowing ratio, the ribs have adverse effects on heat/mass transfer, but for higher blowing ratios, higher and more uniform heat transfer coefficient distributions are obtained than the case without ribs because the ribs prevent the wall jets from being swept away by the crossflow and increase local turbulence of the flow near the surface. Average heat transfer coefficients with rib turbulators are approximately 10% higher than that without ribs, and the higher values are obtained with small pitch of ribs. However, the attack angle of the rib has little influence on the average heat/mass transfer.

Exergetic analysis for optimization of a rotating equilateral triangular cooling channel with staggered square ribs

  • Moon, Mi-Ae;Kim, Kwang-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권3호
    • /
    • pp.229-236
    • /
    • 2016
  • Exergetic analysis was introduced in optimization of a rotating equilateral triangular internal cooling channel with staggered square ribs to maximize the net exergy gain. The objective function was defined as the net exergy gain considering the exergy gain by heat transfer and exergy losses by friction and heat transfer process. The flow field and heat transfer in the channel were analysed using three-dimensional Reynolds-averaged Navier-Stokes equations under the uniform temperature condition. Shear stress transport turbulence model has been selected as a turbulence closure through the turbulence model test. Computational results for the area-averaged Nusselt number were validated compared to the experimental data. Three design variables, i.e., the angle of rib, the rib pitch-to-hydraulic diameter ratio and the rib width-to-hydraulic diameter ratio, were selected for the optimization. The optimization was performed at Reynolds number, 20,000. Twenty-two design points were selected by Latin hypercube sampling, and the values of the objective function were evaluated by the RANS analysis at these points. Through optimization, the objective function value was improved by 22.6% compared to that of the reference geometry. Effects of the Reynolds number, rotation number, and buoyancy parameter on the heat transfer performance of the optimum design were also discussed.

테이퍼가 설치된 리브(rib)이 있는 채널의 열전달에 대한 수치해석 (Numerical Analysis of Heat Transfer in the Ribbed Channel Inserted with Tape)

  • 강호근;안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.638-644
    • /
    • 2010
  • 사각 덕트내 열전달과 유동 양상을 조사하기 위해 꼬임식 테이프 만 설치한 경우와 꼬임식 테이프와 리브(rib)를 설치한 경우에 대해 충분히 발달된 난류유동에 관한 수치 해석을 행하였다. 수치 해석에서는 레이놀즈 수가 8,900에서 29,000 범위의 난류 스월유동, 채널수력직경에 대한 리브의 높이(e/$D_h$)가 0.067, 그리고 채널 수력 직경에 대한 시험부 길이(L/$D_h$)가 30인 경우에 대해 고려하였다. 리브는 채널 바닥면에 만 길이 방향으로 설치하였다. 꼬임식 테이프는 0.1 mm 두께의 탄소강 판 재질이며, 폭은 28 mm, 길이는 900 mm이고 2.5 번 회전시켰다. 각 벽면은 서로 단열된 알루미늄 판으로 구성되었다. 2가지의 가열 조건에 대해 조사 하였다: (1) 사각 전체 벽 면적에 일정한 열유속으로 가열, 그리고 (2) 사각 채널에서 마주보는 상하 양면 만 가열. 연구 결과 상하 양면 만 가열하는 경우가 4면 모두 가열하는 경우보다 열전달 계수가 우수하였고 꼬임식 테이프와 리브를 설치한 경우 열전달 계수가 현저히 향상되었다.

엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석 (NUMERICAL SIMULATION OF FLOW AND HEAT TRANSFER IN A COOLING CHANNEL WITH STAGGERED V-SHAPED RIBS)

  • 명현국;김광용
    • 한국전산유체공학회지
    • /
    • 제13권4호
    • /
    • pp.107-113
    • /
    • 2008
  • The present study numerically simulates the flow and heat transfer characteristics of rib-induced secondary flow in a square cooling channel with staggered V-shaped ribs, extruded on both walls. The rib pitch-to-height ratio (p/h) varies from 2.8 to 10 with the rib-height-to-hydraulic diameter ration (h/$D_h$)of 0.07 and the Reynolds number of 50,000. Shear stress transport (SST) turbulence model is used as a turbulence model. Computational results show that complex secondary flow patterns are generated in the channel due to the snaking flow in the streamwise direction for all tested cases. In the range of p/h=5 to 10 the staggered V-shaped rib gives about 3 times higher heat transfer augmentation than the reference smooth pipe with high heat transfer on both front side and the area around the leading edge of the ribs, while the former cases give about 18 times higher streamwise pressure drop than the latter ones. However, for the thermal performances, based on the equal pumping power condition, the case of p/h=2.8 gives the best result among three cases, mainly due to relatively low streamwise pressure drop, although it gives relatively low heat transfer augmentation.

내부앵커형 콘크리트 충전 기둥의 내력 및 변형능력에 관한 연구 (A Study on the Load Carrying Capacity and Deformation Capacity of the Internal Anchors Welded Cold Formed Concrete Filled Columns)

  • 김선희;염경수;최성모
    • 한국강구조학회 논문집
    • /
    • 제25권4호
    • /
    • pp.347-357
    • /
    • 2013
  • 최근, 콘크리트 충전강관 기둥(CFT)은 우수한 구조성능을 인정받아 현장적용이 활발하게 이뤄지고 있다. 한편 강재개발과 가격 상승으로 인해 단면을 효율적으로 사용하고자 하는 연구가 지속적으로 진행되고 있다. 본 연구실에서는 단면의 효율을 극대화 하기 위해 얇은 L형 플레이트 4개를 각형강관으로 형성한 단면을 제안한다. 이로 인해 강관 내부에 형성된 리브는 폭 중앙에 위치하고 있어 콘크리트와의 앵커역할이 가능하다. 또한 동일한 단면적을 갖는 일반 CFT기둥에 비해 우수한 좌굴내력과 변형성능이 발휘됨을 실험으로 평가되었다. 본 연구에서는 활용범위를 넓히고자 얇은 강판으로 조립된 신형상 기둥을 제안하며 구조적 성능을 재평가 하고자 한다. 실험 주요변수 폭두께비(b/t: 78,96,107) 이다. 실험결과 규준에서 제시하고 있는 폭두께비를 초과했음에도 내부에 설치된 리브의 앵커역할로 인해 충분한 내력을 발휘하며, 변형성능 향상에 유리한 것으로 분석되었다.