• Title/Summary/Keyword: Square Method

Search Result 5,215, Processing Time 0.039 seconds

The Diagnostic Yield and Complications of Percutaneous Needle Aspiration Biopsy for the Intrathoracic Lesions (경피적 폐생검의 진단성적 및 합병증)

  • Jang, Seung Hun;Kim, Cheal Hyeon;Koh, Won Jung;Yoo, Chul-Gyu;Kim, Young Whan;Han, Sung Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.916-924
    • /
    • 1996
  • Bacground : Percutaneous needle aspiration biopsy (PCNA) is one of the most frequently used diagnostic methcxJs for intrathoracic lesions. Previous studies have reponed wide range of diagnostic yield from 28 to 98%. However, diagnostic yield has been increased by accumulation of experience, improvement of needle and the image guiding systems. We analysed the results of PCNA performed for one year to evaluate the diagnostic yield, the rate and severity of complications and factors affecting the diagnostic yield. Method : 287 PCNAs undergone in 236 patients from January, 1994 to December, 1994 were analysed retrospectively. The intrathoracic lesions was targeted and aspirated with 21 - 23 G Chiba needle under fluoroscopic guiding system. Occasionally, 19 - 20 G Biopsy gun was used for core tissue specimen. The specimen was requested for microbiologic, cytologic and histopathologic examination in the case of obtained core tissue. Diagnostic yields and complication rate of benign and malignant lesions were ca1culaled based on patients' chans. The comparison for the diagnostic yields according to size and shape of the lesions was analysed with chi square test (p<0.05). Results : There are 19.9% of consolidative lesion and 80.1% of nodular or mass lesion, and the lesion is located at the right upper lobe in 26.3% of cases, the right middle lobe in 6.4%, the right lower lobe 21.2%, the left upper lobe in 16.8%, the left lower lobe in 10.6%, and mediastinum in 1.3%. The lesion distributed over 2 lobes is as many as 17.4% of cases. There are 74 patients with benign lesions, 142 patients with malignant lesions in final diagnosis and confirmative diagnosis was not made in 22 patients despite of all available diagnostic methods. 2 patients have lung cancer and pulmonary tuberculosis concomittantly. Experience with 236 patients showed that PCNA can diagnose benign lesions in 62.2% (42 patients) of patients with such lesions and malignant lesions in 82.4% (117 patients) of patients. For the patients in whom the first PCNA failed to make diagnosis, the procedure was repeated and the cumulative diagnostic yield was increased as 44.6%, 60.8%, 62.2% in benign lesions and as 73.4%, 81.7%, 82.4% in malignant lesions through serial PCNA. Thoracotomy was performed in 9 patients with benign lesions and in 43 patients with malignant lesions. PCNA and thoracotomy showed the same pathologic result in 44.4% (4 patients) of benign lesions and 58.1% (25 patients) of malignant lesions. Thoracotomy confirmed 4 patients with malignat lesions against benign result of PCNA and 2 patients with benign lesions against malignant result of PCNA. There are 1.0% (3 cases) of hemoptysis, 19.2% (55 cases) of blood tinged sputum, 12.5% (36 cases) of pneumothorax and 1.0% (3 cases) of fever through 287 times of PCNA. Hemoptysis and blood tinged sputum didn't need therapy. 8 cases of pneumothorax needed insertion of classical chest tube or pig-tail catheter. Fever subsided within 48 hours in all cases. There was no difference between size and shape of lesion with diagnostic yield. Conclusion: PCNA shows relatively high diagnostic yield and mild degree complications but the accuracy of histologic diagnosis has to be improved.

  • PDF

Gender Differences in Pain in Cancer Patients (성별에 따른 암환자의 통증 차이)

  • Kim, Hyun-Sook;Lee, So-Woo;Yun, Young-Ho;Yu, Su-Jeong;Heo, Dae-Seog
    • Journal of Hospice and Palliative Care
    • /
    • v.4 no.1
    • /
    • pp.14-25
    • /
    • 2001
  • Purpose : To determine whether there exist gender differences in pain in Korean cancer patients and whether the depression and performance that are often expressed differently between men and women with cancer interact with pain. Method : The results of survey were collected from 140 in- and out-patients (78 male and 62 female) who had cancer treatment at one of the university hospital in Seoul for four months from February of 1999. The severity and interference of pain were examined with the self-reported survey based on Korean version of Brief Pain Inventory (BPI-K). Demographic and clinical information for all patient were compiled by reviewing their medical records, and the level of depression was examined with the Korean version of Beck Depression Inventory (BDI-K). Usual statistical methods, e.g., frequences, means and SDs were used to characterize the sample. The chi-square tests for categorical data and t-test for numerical data were used for group comparison. And the correlation between variables were performed using Pearson correlation coefficient. Resuts : 1) The mean scores of the worst pain for last 24-hours measured with the pain severity of BPI-K were 5.77 in male and 6.45 in female. The pain interference of BPI-K in men was in the order of mood (5.49), enjoy (5.36), and work (5.00), and in women were work (7.48), enjoy (7.16), and mood (6.53). 2) In pain severity, significant difference was found between men and women in the average pain for last 24-hours (t=-2.130, P=.035). In pain interference, significant difference was found between men and women in activity (t=-2.450, P=.015), mood (t=-2,321, P=.022), walk (t=-2.762, P=.007), work (t=-4.946, P=.000), relate (t=-2.595, P=.010), sleep (t=-2.071, P=.040), enjoy (t=-3.198, P=.001). 3) It was found that the items of pain and depression are significantly correlated in men but not in women. Men also exhibited higher correlation in the items of pain and performance status than women. Conclusions : Women report significantly greater average pain for last 24-hours and for all items of pain interference than men. Pain and depression are significantly correlated in men. The results of this study suggest that gender differences in pain should be considered for planning effective pain management program.

  • PDF

A Study on the Spatial Structure of Eupchi(邑治) and Landscape Architecture of Provincial Government Office(地方官衙) in the Late Joseon Dynasty through 'Sukchunjeahdo(宿踐諸衙圖)' - Focused on the Youngyuhyun Pyeongan Province and Sincheongun Hwanghae Province - (『숙천제아도(宿踐諸衙圖)』를 통해 본 조선시대 읍치(邑治)의 공간구조와 관아(官衙) 조경 - 평안도 영유현과 황해도 신천군을 중심으로 -)

  • Shin, Sang sup;Lee, Seung yoen
    • Korean Journal of Heritage: History & Science
    • /
    • v.49 no.2
    • /
    • pp.86-103
    • /
    • 2016
  • 'Sukchunjeahdo' illustration-book, which was left by Han, Pil-gyo(韓弼敎 : 1807~1878)in the late Joseon Dynasty, includes pictorial record paintings containing government offices, Eupchi, and Feng Shui condition drawn by Gyehwa(界畵) method Sabangjeondomyobeop(四方顚倒描法) and is the rare historical material that help to understand spatial structure and landscape characteristics. Youngyuhyun(永柔縣) and Sincheongun(信川郡) town, the case sites of this study, show Feng Shui foundation structure and placement rules of government offices in the Joseon Period are applied such as 3Dan 1Myo(三壇一廟 : Sajikdan, Yeodan, Seonghwangdan, Hyanggyo), 3Mun 3Jo(三門三朝 : Oeah, Dongheon, Naeah) and Jeonjohuchim(前朝後寢) etc. by setting the upper and lower hierarchy of the north south central axis. The circulation system is the pattern that roads are segmented around the marketplace of the entrance of the town and the structure is that heading to the north along the internal way leads to the government office and going out to the main street leads to the major city. Baesanimsu(背山臨水 : Mountain in backward and water in front) foundation, back hill pine forest, intentionally created low mountains and town forest etc. showed landscape aesthetics well suited for the environmental comfort condition such as microclimate control, natural disaster prevention, psychological stability reflecting color constancy principle etc. and tower pavilions were built throughout the scenic spot, reflecting life philosophy and thoughts of contemporaries such as physical and mental discipline, satisfied at the reality of poverty, returning to nature etc. For government office landscape, shielding and buffer planting, landscape planting etc. were considered around Gaeksa(客舍), Dongheon(東軒), Naeah(內衙) backyard and deciduous tree s and flowering trees were cultivated as main species and in case of Gaeksa, tiled pavilions and pavilions topped with poke weed in tetragonal pond were introduced to Dongheon and Naeah and separate pavilions were built for the purpose of physical and mental discipline and military training such as archery. Back hill pine tree forest formed back landscape and zelkova, pear trees, willow trees, old pine trees, lotus, flowering trees etc. were cultivated as gardening trees and Feng-Shui forest with willow trees as its main species was created for landscape and practical purposes. On the other hand, various cultural landscape elements etc. were introduced such as pavilions, pond serving as fire protection water(square and circle), stone pagoda and stone Buddha, fountains and wells, monument houses, flagpoles etc. In case of Sincheongun town forest(邑藪), Manhagwan(挽河觀), Moonmujeong(文武井), Sangjangdae(上場岱) and Hajangdae(下場岱) Market place, Josanshup<(造山藪 : Dongseojanglim(東西長林)>, Namcheon(南川) etc. were combined and community cultural park with the nature of modern urban park was operated. In this context, government office landscape shows the garden management aspect where square pond and pavilions, flowering trees are harmonized around side pavilion and backyard. Also, environmental design technique not biased to aesthetics and ideological moral philosophy and comprehensively considering functionality (shielding and fire prevention, microclimate control, etc.) and environmental soundness etc. is working.

Studies on Genetic Analysis by the Diallel Crosses in $F_2$ Generation of Cowpea(Vigna sinensis savi.) (동부 Diallel Cross$ F_2$세대의 유전분석에 관한 연구)

  • Kim, J.H.;Ko, M.S.;Chang, K.Y.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.28 no.2
    • /
    • pp.216-226
    • /
    • 1983
  • Genetic studies on the $F_2$ generation of a set of half diallel crosses involving six cowpea varieties were conducted. by the randomized block design with three replications to determine combining ability, gene action and the relationships between parents and their $F_2$ hybrids. The 12 agronomic characters namely, days to flowering, days from flowering to maturity, days to maturity, diameter of stem, length of internode, number of branches per plant, length of pod, number of pods per plant, number of grains per pod, number of grains per plant, 100 grain weight and grain weight per plot were observed, and the $F_2$ generation of this diallel set of crosses was analysed for each character according to the method by Jinks and Hayman. The results obtained are summarized as follows: 1. Vr-Wr graphical analyses; The following seven characters, days to flowering, number of branches per plant, length of pod, number of pods per plant, number of grains per plant, 100 grain weight and grain weight per plot appeared to be partially dominant, and over dominance was found for days from flowering to maturity, days to maturity, length of internode and number of grains per pod. But diameter of stem indicated partial dominance near complete dominance. 2. Estimates of genetic variance components; In the degree of dominance,. eight characters, that is, days to flowering, days from flowering to maturity, days to maturity, length of internode, number of pods per plant, number of grains per pod, number of grains per plant and grain weight per plot were expressed larger than 1. And the characters, days from flowering to maturity, number of branches per plant and number of grains per plant as the degree of mean dominance ($H_1$/D) were found to be negative value over other characters. On the other hand, apprent asymmetry of dominance-recessive allele ($H_2$ /$4H_1$) produced comparatively estimates with lower value on days from flowering to maturity, length of internode, number of branches per plant and number of grains per pod. 3. Analyses of combining ability; Mean square value of GCA(general combining ability) appeared to be more important than those of SCA (specific combining ability) for most characters, and among them, grain weight per plot showed the highest mean square value in GCA and SCA. 4. Effect of combining ability; Variety 178 was expressed as the highest GCA effects in five characters (days to flowering days to maturity, number of pods per plant, number of grains per plant and grain weight per plot). SCA effects were differed from parents, characters and crosses, but crosses between TVu 1857 $\times$ TVu 2885 and TVu 2702 $\times$ J78 were shown to be highly with SCA effects on yield.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

How to improve the accuracy of recommendation systems: Combining ratings and review texts sentiment scores (평점과 리뷰 텍스트 감성분석을 결합한 추천시스템 향상 방안 연구)

  • Hyun, Jiyeon;Ryu, Sangyi;Lee, Sang-Yong Tom
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.1
    • /
    • pp.219-239
    • /
    • 2019
  • As the importance of providing customized services to individuals becomes important, researches on personalized recommendation systems are constantly being carried out. Collaborative filtering is one of the most popular systems in academia and industry. However, there exists limitation in a sense that recommendations were mostly based on quantitative information such as users' ratings, which made the accuracy be lowered. To solve these problems, many studies have been actively attempted to improve the performance of the recommendation system by using other information besides the quantitative information. Good examples are the usages of the sentiment analysis on customer review text data. Nevertheless, the existing research has not directly combined the results of the sentiment analysis and quantitative rating scores in the recommendation system. Therefore, this study aims to reflect the sentiments shown in the reviews into the rating scores. In other words, we propose a new algorithm that can directly convert the user 's own review into the empirically quantitative information and reflect it directly to the recommendation system. To do this, we needed to quantify users' reviews, which were originally qualitative information. In this study, sentiment score was calculated through sentiment analysis technique of text mining. The data was targeted for movie review. Based on the data, a domain specific sentiment dictionary is constructed for the movie reviews. Regression analysis was used as a method to construct sentiment dictionary. Each positive / negative dictionary was constructed using Lasso regression, Ridge regression, and ElasticNet methods. Based on this constructed sentiment dictionary, the accuracy was verified through confusion matrix. The accuracy of the Lasso based dictionary was 70%, the accuracy of the Ridge based dictionary was 79%, and that of the ElasticNet (${\alpha}=0.3$) was 83%. Therefore, in this study, the sentiment score of the review is calculated based on the dictionary of the ElasticNet method. It was combined with a rating to create a new rating. In this paper, we show that the collaborative filtering that reflects sentiment scores of user review is superior to the traditional method that only considers the existing rating. In order to show that the proposed algorithm is based on memory-based user collaboration filtering, item-based collaborative filtering and model based matrix factorization SVD, and SVD ++. Based on the above algorithm, the mean absolute error (MAE) and the root mean square error (RMSE) are calculated to evaluate the recommendation system with a score that combines sentiment scores with a system that only considers scores. When the evaluation index was MAE, it was improved by 0.059 for UBCF, 0.0862 for IBCF, 0.1012 for SVD and 0.188 for SVD ++. When the evaluation index is RMSE, UBCF is 0.0431, IBCF is 0.0882, SVD is 0.1103, and SVD ++ is 0.1756. As a result, it can be seen that the prediction performance of the evaluation point reflecting the sentiment score proposed in this paper is superior to that of the conventional evaluation method. In other words, in this paper, it is confirmed that the collaborative filtering that reflects the sentiment score of the user review shows superior accuracy as compared with the conventional type of collaborative filtering that only considers the quantitative score. We then attempted paired t-test validation to ensure that the proposed model was a better approach and concluded that the proposed model is better. In this study, to overcome limitations of previous researches that judge user's sentiment only by quantitative rating score, the review was numerically calculated and a user's opinion was more refined and considered into the recommendation system to improve the accuracy. The findings of this study have managerial implications to recommendation system developers who need to consider both quantitative information and qualitative information it is expect. The way of constructing the combined system in this paper might be directly used by the developers.

CQI Action Team Approach to Prevent Pressure Sores in Intensive Care Unit of an Acute Hospital Korea (중환자의 욕창 예방 연구 : 욕창 예방 QI팀을 중심으로)

  • Kang, So Young;Choi, Eun-Kyung;Kim, Jin-Ju;Ju, Mi-Jung
    • Quality Improvement in Health Care
    • /
    • v.4 no.1
    • /
    • pp.50-63
    • /
    • 1997
  • Background : A pressure sore was defined as any skin lesion caused by unrelieved pressure and resulting in damage to underlying tissue. The health care institutions in the United States were reported the incident rate of pressure sores ranging from 6 to 14 %. Intensive Care Unit needed highest quality of care has been found over 40% incidence rate of pressure sore. Also, Annual expenditures for the care of pressure sores in patients in the United States have been estimated to be $7.5 billion; furthermore, 50 percent more nursing time is required to care for patients with pressure sore in comparison to the time needed to implement preventive measures against pressure sore formation. However, In Korea, there were little reliable reports, or researches, about incidence rates of pressure sore in health care institution including intensive care unit and about the integrated approach like CQI action team for risk assessment, prevention and treatment of pressure ulcers. Therefore, this study was to develop pressure sore risk assessment tool and the protocol for prevention of pressure sore formation through CQI action team activities, to monitor incident rate of pressure sore and the length of sore formation for patients at high risk, and to approximately estimate nursing time for sore dressing during research period as the effect of CQI action team. Method : CQI action team in intensive care unit, launched since early 1996, reviewed the literature for the standardized risk assessment tool, developed the pressure sore assessment tool based on the Braden Scale, tested its validity, compared on statistics including incidence rate of pressure sore for patients at high risk. Throughout these activities, CQI action team was developed the protocol, called as St. Marys hospital Intensive Care Unit Pressure Sore Protocol, shifted the emphasis from wound treatment to wound prevention. After applied the protocol to patients at high risk, the incident rate and the period of prevention against pressure development were tested with those for patients who received care before implementation of protocol by Chi-square and Kaplan-Meier Method of Survival Analysis. Result : The CQI action team found that these was significant difference of in incidence rate of pressure sores between patients at high risk (control group) who received care before implementation of protocol and those (experimental group) who received it after implementation of protocol (p<.05). 25% possibility of pressure sore formation was shown for the patients with 6th hospital day in ICU in control group. In experimental group, the patients with 10th hospital day had 10% possibility of pressure sore. Therefore, there was significant difference(p<.05) in survival rate between two groups. Also, nursing time for dressing on pressure sore in experimental group was decreased as much as 50% of it in control group. Conclusion : The collaborative team effort led to reduced incidence, increased the length of prevention against pressure sore, and declined nursing care times for sore dressing. However, there have had several suggestions for future study. The preventive care system for pressure sore should be applied to patients at moderate, or low risk throughout continuous CQI team activities based on Bed Sore Indicator Fact Sheet. Hospital-wide supports, such as incentives, would be offered to participants for keeping strong commitment to CQI team. Also, Quality Information System monitoring incidents and estimating cost of poor quality, like workload (full time equivalence) or financial loss, regularly in a hospital has to be developed first for supporting CQI team activities as well as empowering hospital-wide QI implementation. Being several limitations, this study would be one of the report cards for the CQI team activities in intensive care unit of an acute hospital and a trial of quality improvement of health care in Korea.

  • PDF

Effect of Barley Straw Application on Soil Properties, Rice Yield and Plowable Stress with Plowing Methods and Irrigation Rates in Barley- Rice Double Cropping System (이모작 벼 재배시 경운방법 및 관개량에 따른 쌀 수량, 토양특성에 대한 보릿짚 시용효과)

  • Yang, Chang-Hyu;Kim, Byung-Soo;Park, Woo-Kyun;Lee, Deog-Bae;Yoo, Chul-Hyun;Kim, Jae-Duk;Jeong, Kwang-Yong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.3
    • /
    • pp.201-207
    • /
    • 2007
  • To reduce both the floatation of the seedling of rice and the failure in standing in the paddy field when the barley straw was applied to paddy field before planting the rice, we tested the effect of rice rooting with plowing methods and irrigation rates for 2 years from 2003 to 2004. This study was carried out in paddy field with Fluvio-Marine deposit in Jeonbug series and the operating accuracy and the change of soil physico-chemical properties depending on plowing methods and irrigation rates following the barley straw applying were examined. There was a less floatation of barley straw in the dry-rotaryI+water-rotaryI(DRI+WRI) plot than in the plowing+water-rotary(PL+WRI) plot. The ratio of miss-planted and floating seedling also decreased by 1.7%, 2.6% in the DRI+WRIplot compared with PL+WRI plot. The soil physical property was improved with the decreasing soil hardness, bulk density and increasing soil porosity after the application of barley straw, especially enhanced greatly in the increase of porosity, gaseous phase and with the decrease of soil hardness, bulk density of subsurface soil in DRI+WRI plot. And the change of soil chemical property were increased the content of total carbon$^{\circ}{\S}$nitrogen$^{\circ}{\S}$organic matter and available phosphate while decreased the content of exchangeable cations and available silicate after the application of barley straw. Also the content of organic matter, available phosphate and cation exchangeable capacity were increased, whereas caron/nitrogen ratio was decreased in DRI+WRI plot compared with PL+WRI plot. The number of panicles, spikelets per square meter were increased and 1,000 grains weight of hulled rice was gained more in DRI+WRI plot at irrigation rate of $500ton\;ha^{-1}$, in DRI+WRII plot at irrigation rate of $700ton\;ha^{-1}$. So the rice yields were increased by 7%, in DRI+WRI and 5% in DRI+WRII plot, respectively compared with PL+WRI plot. The result of this study indicated that the most appropriate plowing method with barley straw application on rice cultivation at double cropping in normal paddy field plain land was DRI+WRI.

A Study on Subjective Symptoms of a Oral Malodor in Korean Adults (한국 성인의 주관적 구취 자각증상에 대한 연구)

  • Yoon, Mi-Sook;Youn, Hye-Jeong
    • Journal of dental hygiene science
    • /
    • v.8 no.3
    • /
    • pp.123-129
    • /
    • 2008
  • The purpose of this study was to investigate the actual conditions of the subjective oral malodor perception of the survey subjects. Through the subjective questionnaire method over about 3 months from June to August in 2007, the data was collected targeting 275 adults. Statistical methods used were Chi-square test, Fisher's exact test and One-way ANOVA. And, the following results were obtained. 1. When having seen the ratio of those who were conscious of oral malodor, the adults, who responded with saying of feeling oral malodor at present and at ordinary times, accounted for 68.4% and 79.3%, respectively. And, the adults, who responded with saying of not feeling, were indicated to be 31.6%(at present) and 20.7%(at ordinary times), respectively. 2. Almost 83.5% of total people answered that they had most severe oral malodor at the time of awakening and 51.9% of subjects answered tongue contributed to the their oral malodor. 3. About the type of oral malodor, although 37.2% of the group thought the type of oral malodor was a food smell and fetid smell was second general burning smell occurred the time of hunger(22.5%). 4. In the answers of hoping for treatment of oral malodor, 66.9% of the people showed positive response to dental treatment for controlling their oral malodor. Especially 7.3% of subjects showed very big desire for treatment. 5. In the level of oral malodor that is felt now according to the time of a meal, the case of within 1 hour after having a meal was responded to be not felt the oral malodor with 44.7%. And, there was response with saying of not feeling oral malodor in 37.6% as for 1-2 hours, 16.3% as for 2-3 hours, 14.8% as for 3-4 hours, and 23.7% as for more than 4 hours. Thus, the level of oral malodor according to the time of a meal showed the statistically significant difference(p<0.01). Through the results of this study, it could be known about whether or not being conscious of oral malodor in general people, the main cause and region for oral malodor, the importance and practicing method of tongue brush through literature. Accordingly, there is necessity of further researching and comparing whether or not being conscious of oral malodor by diversely surveying relevancy with factors of causing oral malodor based on the objective oral malodor measurement value. The future diverse researches are thought to be necessarily performed in order to prevent or reduce oral malodor.

  • PDF