• 제목/요약/키워드: Square Column

검색결과 338건 처리시간 0.024초

Effect of bond and bidirectional bolting on hysteretic performance of through bolt CFST connections

  • Ajith, M.S.;Beena, K.P.;Sheela, S.
    • Earthquakes and Structures
    • /
    • 제19권5호
    • /
    • pp.315-329
    • /
    • 2020
  • Through bolt connections in Concrete Filled Steel Tubes (CFSTs) has been proved to be good in terms of seismic performance and constructability. Stiffened extended end plate connection with full through type bolt helps to avoid field weld altogether, and hence to improve the quality of joints. An experimental study was conducted on the hysteretic performance of square interior beam-column connections using flat extended end plates with through bolt. The study focuses on the effect of the bond between the tie rod and the core concrete on the cyclic performance of the joint. The study also quantifies how much the interior joint is getting strengthened due to the confinement effect induced by bi-directional bolting, which is widely used in 3D moment resisting frames. For a better understanding of the mechanism and for the prediction of shear capacity of the panel zone, a mathematical model was generated. The various parameters included in the model are the influence of axial load, amount of prestress induced by bolt tightening, anchorage, and the concrete strut action. The study investigates the strength, stiffness, ductility, and energy dissipation characteristics. The results indicate that the seismic resistance is at par with American Institute of Steel Construction (AISC) seismic recommendations. The bidirectional bolting and bond effect have got remarkable influence on the performance of joints.

A new model for T-shaped combined footings part I: Optimal dimensioning

  • Luevanos-Rojas, Arnulfo;Lopez-Chavarria, Sandra;Medina-Elizondo, Manuel
    • Geomechanics and Engineering
    • /
    • 제14권1호
    • /
    • pp.51-60
    • /
    • 2018
  • The foundations are classified into shallow and deep, which have important differences: in terms of geometry, the behavior of the soil, its structural functionality, and its constructive systems. The shallow foundations may be of various types according to their function; isolated footings, combined footings, strip footings, and slabs foundation. The isolated footings are of the type rectangular, square and circular. The combined footing may be rectangular, trapezoidal or T-shaped in plan. This paper presents a new model for T-shaped combined footings to obtain the most economical contact surface on the soil (optimal dimensioning) to support an axial load and moment in two directions to each column. The new model considers the soil real pressure, i.e., the pressure varies linearly. The classical model uses the technique of test and error, i.e., a dimension is proposed, and subsequently, the equation of the biaxial bending is used to obtain the stresses acting on each vertex of the T-shaped combined footing, which must meet the conditions following: The minimum stress should be equal or greater than zero, and maximum stress must be equal or less than the allowable capacity that can withstand the soil. To illustrate the validity of the new model, numerical examples are presented to obtain the minimum area of the contact surface on the soil for T-shaped combined footings subjected to an axial load and moments in two directions applied to each column.

핀치이론의 수정 모델을 이용한 스프레이 모드의 해석 (Analysis of Spray Mode Using Modified Pinch Instability Theory)

  • 박아영;;김선락;유중돈
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.44-44
    • /
    • 2009
  • While the pinch instability theory (PIT) has been widely employed to analyze the spray transfer mode in the gas metal arc welding (GMAW), it cannot predict the detaching drop size accurately. The PIT is modified in this work to increase the accuracy of prediction and to simulate the molten tip geometry to be more physically acceptable. Since the molten tip becomes a cone shape in the spray mode, the effective wire diameter is formulated that the effective diameter is inversely proportional to current square. Modifications are also made to consider the finite length of the liquid column and current leakage through the arc. While the effective diameter influences drop transfer significantly, the current leakage has negligible effects. The effects of modifications on drop transfer are analyzed, and the predicted drop diameters show good agreements with the experimental data of the steel wire.

  • PDF

Experimental and theoretical studies on SHS column connection with external stiffening ring under static tension load

  • Rong, Bin;You, Guangchao;Zhang, Ruoyu;Ma, Xu;Quan, Xinxin
    • Steel and Composite Structures
    • /
    • 제28권2호
    • /
    • pp.167-177
    • /
    • 2018
  • In order to investigate mechanical properties in the core area of Square Hollow Section(SHS) column connection with external stiffening ring, four specimens were tested under the static tension load. The failure modes, load-displacement curves and strain distribution were analyzed to study the mechanical properties and the load transfer mechanism of the core area of connections. The connections behave good ductility and load-bearing capacity under the static tension load. Parametric analysis was also conducted, in which the thickness of steel tube, extended width and thickness of the stiffening ring were considered as the parameters to investigate the effects on mechanical properties of the connections. Based on the experimental results, an analytical method for the bearing capacity of connection with external stiffening ring under the static tension load was proposed. The theoretical results and the experimental results are in good agreement, which indicates that the theoretical calculation method of the bearing capacity is advisable.

An evaluation equation of load capacities for CFT square column-to-beam connections with combined diaphragm

  • Choi, Sung-Mo;Jung, Do-Sub;Kim, Dae-Joong;Kim, Jin-Ho
    • Steel and Composite Structures
    • /
    • 제7권4호
    • /
    • pp.303-320
    • /
    • 2007
  • The objective of this study is to clarify the structural features of members consisting of connection, as a series of the previous study on the CFT column-to-beam tensile connection with combined cross diaphragm. This connection has the merits that the stress is distributed evenly on the beam flange and the diaphragm and the stress concentration is reduced, by improving the stress transfer route and restraining abrupt deformation of diaphragm. The finite element analysis was performed to find out the stress transfer through sleeve which is an important member of the connection with combined cross diaphragm. The length and thickness of sleeve were used as variables for the analysis. As the analysis results, the length and thickness of sleeve didn't influence on the capacity of the connection and played a role of a medium to transfer the stress from the diaphragm to the filled concrete. It is proposed that the appropriate length of sleeve be the same value as the diameter of sleeve and the appropriate ratio of sleeve diameter to sleeve thickness be 20. Two equations for evaluation of the load-carrying capacity of the connection were also proposed through the modification of the evaluation equation suggested in the previous study.

충전성을 개선한 각형CFT 기둥-보 접합부의 구조 특성 (Structural Characteristic of Beam-to-Column Connections in Rectangular CFT Structures Considering Concrete Filling)

  • 박제영;이명재
    • 한국강구조학회 논문집
    • /
    • 제25권2호
    • /
    • pp.187-196
    • /
    • 2013
  • CFT구조의 기둥-보 접합부는 강관의 국부좌굴을 방지하기위해 다이아프램이 필요하다. 외측다이아프램 형식은 관통다이아프램 형식보다 콘크리트의 충전성이 좋으나 시공성과 건축설비와 공조하는 측면에서 불편함이 있다. CFT구조 접합부의 상부 다이아프램은 외측다이아프램 형식으로 하고 하부 다이아프램은 관통다이아프램 형식으로 하였다. 이것은 건축물에서 바닥슬래브가 있으므로 상부 다이아프램은 바닥슬래브와 일체가 되고 하부 다이아프램으로 관통다이아프램을 적용하여 건축설비와의 마찰을 피하고자 한 것이다. 결과적으로 충전성을 개선시킨 CFT구조의 구조성능은 상, 하부 모두 관통다이아프램을 적용한 구조와 비교하면 동일하다는 것을 알 수 있다.

후좌굴 변단면 기둥의 기하 비선형 해석 (Geometrical Nonlinear Analyses of Post-buckled Columns with Variable Cross-section)

  • 이병구;김석기;이태은;김권식
    • 대한토목학회논문집
    • /
    • 제29권1A호
    • /
    • pp.53-60
    • /
    • 2009
  • 이 논문은 양단회전 후좌굴 변단면 기둥의 기하 비선형 해석에 관한 연구이다. 기둥의 변단면은 변화폭, 변화깊이, 정방형 변단면으로 채택하였다. Bernoulli-Euler 보 이론을 이용하여 후좌굴 기둥의 정확탄성곡선을 지배하는 미분방정식을 유도하였다. 이 미분방정식은 두 개의 미지수를 가지며 이러한 미분방정식을 풀 수 있는 수치해석 방법을 개발하였다. 후좌굴 기둥의 수치해석 결과로 평형경로, 정확탄성곡선 및 합응력을 산정하였다. 실험을 통하여 후좌굴 거동의 이론을 검증하였다.

Infilled steel tubes as reinforcement in lightweight concrete columns: An experimental investigation and image processing analysis

  • N.Divyah;R.Prakash;S.Srividhya
    • Computers and Concrete
    • /
    • 제33권1호
    • /
    • pp.41-53
    • /
    • 2024
  • Under constant and cyclic axial compression, square composite short columns reinforced with Self Compacting Concrete (SCC) added with scrap rubber infilled inside steel tubes and with different types of concrete were cast and tested. The test is carried out to find the effectiveness of utilizing an aggregate manufactured from industrial waste and to address the problems associated with the need for alternative reinforcements along with waste management. The main testing parameters are the type of concrete, the effect of fiber inclusion, and the significance of rubber-infilled steel tubes. The failure modes of the columns and axial load-displacement curves of the steel tube-reinforced columns were all thoroughly investigated. According to the test results, all specimens failed due to compression failure with a longitudinal crack along the loading axis. The fiber-reinforced column specimens demonstrated improved ductility and energy absorption. In comparison to the normal-weight concrete columns, the lightweight concrete columns significantly improved the axial load-carrying capacity. The addition of basalt fiber to the columns significantly increased the yield stress and ultimate stress to 9.21%. The corresponding displacement at yield load and ultimate load was reduced to 10.36% and 28.79%, respectively. The precision of volumetric information regarding the obtained crack quantification, aggregates, and the fiber in concrete is studied in detail through image processing using MATLAB environment.

사질토양에서의 Benzene의 이동성에 관한 연구 (Transport and Fate of Benzene in a Sandy Soil)

  • 백두성;김동주
    • 대한지하수환경학회지
    • /
    • 제6권2호
    • /
    • pp.95-100
    • /
    • 1999
  • 토립자 표면에서의 흡착에 의한 토양에서의 탄화수소계 화합물의 지연효과는 잘 알려진 현상이다. 본 연구에서는 배치시험과 주상시험을 수행함으로써 사질토양에서 Benzene의 이동성에 대한 지연효과를 조사하였다. 배치시험을 위하여 토양시료와 다양한 초기농도의 Benzene 용액을 48시간 반응시켰고. 초기용액과 평행상태의 Benzene 용액의 농도를 HPLC를 이용하여 분석하였다. 주상시험은 파괴곡선으로 알려진 시간에 따른 용액의 농도를 측정함으로써 수행되었다. 추적자로는 10 g/L 농도의 KCI과 0.88 g/L의 Benzene 용액을 사용하였고 .각각의 용액을 토양시료의 상부경계면에 순간주입한 후 정상류 상태에서 배출구로 빠져나온 용탈수의 농도를 EC-meter와 HPLC를 이용하여 측정하였다. 배치시험의 결과로부터 linear adsorption isotherm에 의한 분배계수가 측정되었고 주상시험 조건의 용적밀도 및 함수율을 고려한 지연계수가 산정되었다. 주상시험의 결과 i) Benzene의 첨두농도는 KCl 첨두농도보다 상당히 낮았으나. ⅱ) 첨도농도의 도달시간은 거의 일치하였다. 첨두농도의 도달시간이 일치한다는 결과는 지연효과가 일어나지 않았다는 것을 지시하며, 배치시험의 결과로부터 산정된 지연계수를 고려하여 예측된 파과곡선은 Benzene의 주상시험 결과와 일치하지 않았다. Benzene 농도의 뚜렷한 감소를 설명할 수 있는 유일한 방법은 convection-dispersion equation(CDE) 모델에서 비가역 흡착에 의한 농도의 절대적 감소를 고려하는 감쇄계수(decay or sink coefficient)를 적용해야 하는 것으로 판단된다.

  • PDF

내부유공판을 사용한 각형 CFT 기둥-보 단순인장 접합부의 실험적 연구 (An Experimental Study on Simple Tension Connections for Square CFT Column to Beam Using Internal Plate with Holes)

  • 이성희;정헌모;양일승;최성모
    • 한국강구조학회 논문집
    • /
    • 제21권6호
    • /
    • pp.575-583
    • /
    • 2009
  • 최근 건물이 고층화 됨에 따라 건물의 중량감소와 시공의 효율성 확보를 위해 기존 S, RC, SRC 이외에 새로운 구조시스템이 적용되고 있으며, 그중에서도 CFT 구조는 우수한 구조성능과 시공성으로 많은 건설현장에 적용되어 왔다. CFT 구조는 접합부 구성시 보 플랜지 하중을 기둥과 반대편 보에 원활히 전달하기 위한 다이아그램이 필요하며 특히 기둥 좌우에 춤이 다른 보가 접합될 때 보의 하부 플랜지 하중전달을 위한 다이아프램 구성과 콘크리트 충전성 확보에 어려움이 있었다. 본 연구에서는 하부 보 플랜지 하중을 기둥에 원활히 전달하기 위해 CFT 기둥 내부에 유공판을 세로로 접합하는 형식의 접합상세를 제안하였다. 이 접합형식은 CFT 기둥 내부에 콘크리트가 충전될 때 콘크리트가 내부 유공판의 구멍을 관통하여 채워짐으로써 보 플랜지 하중전달에 콘크리트의 앵커효과를 이용하는 방법이며 유공판이 수직으로 설치됨으로써 콘크리트 충전성도 향상시킬 수 있다. 제안된 접합부의 구조거동분석을 위해서 내부유공판의 설치방향, 콘크리트의 충전 유/무, 내부유공판의 두께, 전단구멍의 개수등을 변수로하여 5개의 실험체를 제작하고 실험체의 실험적연구를 진행하였다.