• 제목/요약/키워드: Sprue

검색결과 45건 처리시간 0.042초

주입선 및 열처리에 따른 IPS Empress 도재의 미세구조에 관한 연구 (A STUDY ON THE MICROSTRUCTURE OF IPS EMPRESS CERAMICS ACCORDING TO THE HEAT TREATMENT AND SPRUE TYPE)

  • 동진근;오상천
    • 대한치과보철학회지
    • /
    • 제36권5호
    • /
    • pp.772-785
    • /
    • 1998
  • This study was undertaken to clarify the microstructure of the different IPS Empress ingots by etching and to observe the change of leucite crystal structure according to subsequent heat treatment and the crystal distribution according to sprue types(${\phi}2.8mm$, single sprue; ${\phi}1.8mm$, double sprue) by scanning electron microscopy. IPS Empress T1, O1 ingots used for staining technique, and Dentin(A2) ingots used for layering technique were selected for this study. To observe the microstructures of these ingots before pressing, the specimens were prepared in splinters($3{\times}3{\times}3mm$) taken from the original ingots. And to estimate crystal distribution and microstructural change by sprue type and subsequent heat treatment. the specimens($3{\times}3{\times}3mm$) were heat-pressed through the two types of sprues with different diameters and numbers, and all specimens were fired according to the recommended firing schedule. The observed surface was ground with waterproof papers($#800{\sim}#1800$) on the grind polisher and was cleaned ultrasonically. All specimen were etched with 0.5% hydrofluoric acid. After etching, the surface was treated by ion sputter coating for SEM observation at an accelerating voltage of 20kV. In all specimens, the central area of ground surface was observed because there was less difference in microstructure between the peripheral area and the central area. The results were as follows ; 1. In the microstructure according to the ingot type, there was a wide difference between the staining (T1,O1) and layering(Dentin A2) ingots, but there was not a considerable difference between the T1 ingot and the O1 ingot for staining technique. 2. In all specimens, the crystal dispersion of IPS Empress ceramic using double sprue was significantly more scattered than that of IPS Empress ceramic using single sprue. The degree of scattering was strongest in the Dentin(A2) specimen and weakest in the O1 ingot. 3. In the microstructural change according to the subsequent heat treatment, all of ingots had some microcracks in the inside of the leucite crystal and the glass matrix after pressing. The inner splinters of the leucite crystal became smaller, and more microcracks occurred in the glass matrix due to increasing heat treatment times. 4. The size of leucite crystals varied from $1{\mu}m\;to\;5{\mu}m$. The mean size of mature crystals was about $5{\mu}m$. The form of the crystal was similar to a circle when it was smaller and similar to an ellipse when it was larger.

  • PDF

주입선의 설계가 임플란트 보철물의 적합도에 미치는 영향 (Effect of the Sprue Design on the Fitness of Implant Prosthesis)

  • 황성택;안재석;신상완
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.57-63
    • /
    • 2008
  • Statement of problem: Conventional techniques for implant framework fabrication produce significant error that is inconsistent with passive-fit requirement for osseointegrated implants. One of the etiologic factors which cause the errors is a sprue which may deform the framework during solidification and contraction. Purpose: This study was aimed to evaluate objectively effect of the sprue design on the accuracy of fit of implant prosthesis. Materials and method: Three different designs were considered relative to effect of casting accuracy. The first design had straight sprues and a button of excess alloy at the non-casting end of the sprues. The second was runner bar design(with the button). The last was straight sprues design(without the button). Gold cylinder and laboratory analogue had been used to diminish variables affecting to casting accuracy. Gold alloy and pressure-vacuum casting machine had been used. Marginal gap had been measured by SEM. One-way ANOVA and Duncan test had been used for statistical analysis. Results: The first design showed $79.87{\pm}13.95{\mu}m$ marginal gap. The second and third were $40.17{\pm}15.8{\mu}m$ and $35.17{\pm}9.95{\mu}m$ respectively. Conclusion: Straight sprues without button and runner bar designs were more accurate than straight sprues with button design(P<.05).

  • PDF

Computational design of mould sprue for injection moulding thermoplastics

  • Lakkannan, Muralidhar;Mohan Kumar, G.C.;Kadoli, Ravikiran
    • Journal of Computational Design and Engineering
    • /
    • 제3권1호
    • /
    • pp.37-52
    • /
    • 2016
  • To injection mould polymers, designing mould is a key task involving several critical decisions with direct implications to yield quality, productivity and frugality. One prominent decision among them is specifying sprue-bush conduit expansion as it significantly influences overall injection moulding; abstruseness anguish in its design criteria deceives direct determination. Intuitively designers decide it wisely and then exasperate by optimising or manipulating processing parameters. To overwhelm that anomaly this research aims at proposing an ideal design criteria holistically for all polymeric materials also tend as a functional assessment metric towards perfection i.e., criteria to specify sprue conduit size before mould development. Accordingly, a priori analytical criterion was deduced quantitatively as expansion ratio from ubiquitous empirical relationships specifically a.k.a an exclusive expansion angle imperatively configured for injectant properties. Its computational intelligence advantage was leveraged to augment functionality of perfectly injecting into an impression gap, while synchronising both injector capacity and desired moulding features. For comprehensiveness, it was continuously sensitised over infinite scale as an explicit factor dependent on in-situ spatio-temporal injectant state perplexity with discrete slope and altitude for each polymeric character. In which congregant ranges of apparent viscosity and shear thinning index were conceived to characteristically assort most thermoplastics. Thereon results accorded aggressive conduit expansion widening for viscous incrust, while a very aggressive narrowing for shear thinning encrust; among them apparent viscosity had relative dominance. This important rationale would certainly form a priori design basis as well diagnose filling issues causing several defects. Like this the proposed generic design criteria, being simple would immensely benefit mould designers besides serve as an inexpensive preventive cliché to moulders. Its adaption ease to practice manifests a hope of injection moulding extremely alluring polymers. Therefore, we concluded that appreciating injectant's polymeric character to design exclusive sprue bush offers a definite a priori advantage.

주입선 형태가 티타늄 주조관의 변연재현성에 미치는 영향 (THE EFFECT OF SPRUE DESIGN ON THE MARGINAL REPRODUCIBILITY OF CAST TITANIUM CROWNS)

  • 박재경;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제40권4호
    • /
    • pp.352-364
    • /
    • 2002
  • There has been a great interest in the use of titanium for fixed and removable prostheses in recent because of its excellent biocompatibility. However the high melting temperature and chemical reactivity of titanium necessitates casting systems different from those used in conventional casting. The current titanium casting systems are based on an electric-arc design for melting the metal in an argon atmosphere and its exclusive investment. Despite the new developments in Ti casting systems, inadequate mold filling and internal porosity are frequently observed casting defects. Therefore, the study on the fabrication technique including sprue design to solve these casting defects is still necessary. In this study to evaluate the effect of sprue design on the castability of simulated cast titanium crowns, 10 cylindrical cast crowns for each group with four different sprue design(Single group. Double group, Runner bar group. Reservoir group) were fabricated. An impression of the entire casting margin was made and cut at $90^{\circ}$ intervals, and the sections were photographed in a microscope at $100{\times}$ magnification to record marginal discrepancy. The internal porosities of the cast crowns were disclosed by radiographs. Within the limits of this study. the following conclusions were drawn. 1. The overall mean marginal discrepancies for each group were as follows: Double group, $43.65{\mu}m$; Reservoir group, $50.27{\mu}m$; Single group, $54.17{\mu}m$; Runner bar group, $58.90{\mu}m$ (p<0.05). 2. The mean of marginal discrepancies for wax patterns was $10.65{\mu}m$. 3 The numbers of internal porosity showed the most in Runner bar group followed by Single group, Reservoir group, and Double group.

THE EFFECTS OF SPURE AND INVENTS ON THE CASTING ACCURACY AND POROSITY OF TI-NI CASTINGS

  • Cho Lee-Ra;Yi Yang-Jin;Park Chan-Jin
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.342-350
    • /
    • 2003
  • Statement of problem. Titanium-Nickel alloy might be used in various prosthetic restorations since it has a unique property such as super-elasticity and high fatigue resistance. However, little is known about the casting ability of this alloy. Purpose. This in vitro study compared the casting accuracy and the porosity made with different investments and various sprue designs to ascertain what casting condition would be better for the fabrication of Ti-Ni cast restorations. Material and methods. A total of 70 Ti-Ni alloy crowns were made and divided into 7 groups of 10 copings on a metal master die. For measuring the effect of the sprue numbers, two groups with one and two 8-gauge sprues were compared. Moreover, the results of the conventional sprue and the double thickness sprues were compared. Three investments were used; carbon free phosphate bonded investment, titanium investment and gypsum bonded investment. The cast restorations were evaluated at 48 points on the entire circumferential margin with a stereomicroscope measuring in micrometers. Each crown was radiographically examined for casting defects and porosity. Data on casting accuracy were analyzed using two-way and Post hoc Scheffe's comparison to determine whether significant differences existed at the 95% confidence level. Student-Newman-Keuls test were performed to identify significant differences in the number of voids. Results. The double sprueing group and double thickness group had significantly less marginal discrepancy than the single sprueing group (P<.05 and P<.01, respectively). The castings with phosphate bonded investment showed the least marginal discrepancy and the smoothest surface. The castings invested in the gypsum bonded investment had the greatest gaps in margin and the largest failure rate. The double sprueing group and phosphate bonded investment group had significantly smaller void numbers and smaller void size than the other groups. Conclusion. Within the limitations of this in vitro study, the casting accuracy of the groups using thicker, double sprue design and the phosphate bonded investment was significantly superior. Moreover, void number and size were less than other groups.

MECHANICAL PROPERTIES OF REUSED LITHIUM DISILICATE GLASS-CERAMIC OF IPS EMPRESS 2 SYSTEM

  • Oh Sang-Chun
    • 대한치과보철학회지
    • /
    • 제40권6호
    • /
    • pp.572-576
    • /
    • 2002
  • This investigation was designed to estimate the biaxial flexure strength and fracture toughness of lithium disilicate glass-ceramics of IPS Empress 2 system pressed with as-received ingots and their sprue buttons. Two groups of the lithium disilicate glass-ceramics were prepared as follows: group 1 is ingot-pressed group; group 2 is sprue button-pressed group. A ball-on-three-ball test was used to determine biaxial flexure strength (BFS) of disks in wet environment. Scanning electron microscopy(SEM) analysis was conducted to observe the microstructure of the ceramics. Unpaired t-test showed that there were no differences in the mean biaxial Hem strength (BFS) and KIC values between group 1 and 2 (p > 0.05). Two groups showed similar values in the KIC and the strength at 5% failure probability. The SEM micrographs of the IPS Empress 2 glass-ceramic showed a closely packed, multi-directionally interlocking pattern of numerous lithium disilicate crystals protruding from the glass matrix. The lithium orthophosphate crystals could not be observed on the fracture surface etched. There was no a marked difference of the microstructure between group 1 and 2. Although there were no tests including color stability, casting accuracy, etc., the results of this study implied that we could reuse the sprue button of the pressed lithium disilicate glass-ceramic of IPS Empress 2 system.

주입선의 설치방법이 금속의 주조성에 미치는 영향에 관한 실험적 연구 (Sprue design and its effect on the castability of ceramonetal nonprecious alloys)

  • 김웅철
    • 대한치과기공학회지
    • /
    • 제10권1호
    • /
    • pp.5-10
    • /
    • 1988
  • The purpose of this study was to evaluate the effect of spure designs and air vent on the relative castability of the nonprecious alloys, commonly used to make ceamometal restorations. Samples of total 30 were constructed and devided into 6 groups according to two variables, sprue design and air bent. The total number of completly cast squares was counted, verified, and recorded. The results obtained were as follows: 1. The runner bar or Rousseau designs yield better castability than reservoir design(P<0.1) 2. When the air vent was attached, only the castability of reservoir design was significantly different from runner bar or Rousseau designs.

  • PDF

Effects of Coating Materials on Fluidity and Temperature Loss of Molten Metals from Runner Systems in Full Moulds.

  • Cho, Nam-Don;Kim, Yong-Hyun;Choi, Jung-Kwon
    • 한국주조공학회지
    • /
    • 제10권1호
    • /
    • pp.31-42
    • /
    • 1990
  • The full mould casting process in one of the newly developed techniques which has many advantages. Unbonded sand mould has been prepared for the major mould and $CO^2$ gas mould has been used occasionally for comparison. Patterns were built up with expanded polystyrene and coated with three different materials. Silica, graphite and zircon were used for the coating layer. The effects on fluidity and temperature loss of molten metals were investigated. The molten metals were Al-5% Si alloy, Cu-30% Zn alloy and gray iron of approximately 4.0% of carbon equivalent. Experimental variables were runner section area, superheat, sprue height, coating materials, coating thickness and apparent density of EPS pattern. The effects of coating materials on fluidity and temperature loss of the molten metals during transient pouring are summarized as follows : As runner section area, superheat and sprue height increased, fluidity increased. Temperature loss decreased as runner section area and sprue height increased. However, reversed effects were observed in the case of superheat increment. The coating materials decreased the fluidity of each alloy in the order of silica, graphite and zircon. Zircon brought to the highest temperature loss among the coating materials used. The fluidity increased in the order gray iron, Cu-30% Zn and Al-5% Si alloy while temperature loss in the reverse order. Especially in case of reduced pressure process, the fluidity was increased apparently. Al-5% Si alloy showed the lowest temperature loss among the alloys. The increment of the apparent density of EPS pattern resulted in the fluidity decrease and temperature loss increase. The relation between fluidity and temperature loss of each alloy can be expressed by the following equation within the coating thickness limit of 0.5-1.5㎜. F^*={\frac{a}{T^*-b}}-c$ where, $F^*$ : fluidity in the Full mould, $T^*$ : temperature loss in the mould. a : parameter for full mould. b, c : constants.

  • PDF