• Title/Summary/Keyword: Sprinkler System

Search Result 153, Processing Time 0.023 seconds

An Improvement of Fire Safety Code for Rack-Type Warehouse in Korea (국내 랙크식 창고의 방화관련 규정 개선에 관한 연구)

  • Kim, Woon-Hyung;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.69-75
    • /
    • 2014
  • Recently Amore pacific rack-type warehouse fire broke out and argue an urgent improvement of fire protection design code including automatic sprinkler and detection design. Various type of commodities have their unique fire characteristics from fire spread rate and heat lease rate and fire hazard depends on storage height, rack arrangement, aisle width, fire load etc. With increasing ceiling height for more storage space prevent effective water spray of sprinkler head, also delays detection time causes failure of early suppression. To achieve fire protection code performance of this occupancy, Major code articles relating to a classification of commodity, sprinkler system installation, detection and fire fighting are reviewed and suggested based on fire case analysis, code review between country and field survey.

The Effect of the Combined Operation of Sprinkler and Vent Systems on the Smoke Control in a Horizontal Corridor (스프링클러와 배연설비의 통합작동이 수평통로의 연기제어에 미치는 영향)

  • Jeon Heung-Kyun;Choi Young-Sang;Choo Hong-Lok;Jang Jun-Young
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.70-89
    • /
    • 2005
  • Fire scenarios in a space $20.0m\;\times\;4.0m$ floor and 3.0m high were simulated by using computational fluid dynamics program (FDS 4.0.3) to investigate the effect of the combined operation of both sprinkler and vent systems, which are installed for cooling and blocking smoke which propagates beneath the ceiling of a horizontal corridor, on the temperature and smoke density of it. It was shown that the combined operation both sprinkler and vent systems was more effective than each operation for cooling and blocking smoke, the number of operating sprinklers was two because of corner effect of wall, and over-installed sprinklers deteriorated the effect of cooling and blocking smoke. This study showed that the case of two sprinklers and vent flow rate $3.0m^3/s$ in fire scenario was the most effective for cooling and blocking smoke. It was confirmed that the smoke downdrag occurs in operating sprinkler system, and the more smoke droplets produced by increasing fire size, the greater smoke downdrag occurred.

Deposit Amounts of Dithianone on Citrus leaves by Different Spray Methods (살포 방법에 의한 살균제 Dithianon의 감귤 잎 부착량 비교)

  • Jeon, Hye-Won;Hong, Su-Myeong;Hyun, Jae-Wook;Hwang, Rok-Yeon;Kwon, Hye-Young;Kim, Taek-Kyum;Cho, Nam-Jun
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • In order to obtain efficient control effect of the pesticide, it is important to ensure uniform adhesion to the desired plant parts at the right time. Pesticide spray method (application technology) is an important factor affecting the efficacy and crops persistent expression. The aim of this study was to develop an efficient system to investigate the coating weight distribution of citrus leaves due to the difference between the nozzle and spray sprinkler system using dithianon used in citrus scab. Other An, engine type sprayer was used as the control. Speed sprayer and different sprinklers were wsed to way the deposit amounts of dithianon on citrus leaves. The test was conducted at the National Institute of Horticultural Herbal Science Citrus Research Station, located in the circle citrus Jeju Island. In order to examine whether the citrus orchard spray and the evenl on the whole, dithianon (43% flowable 1000-fold dilution) was sprayed, filter paper and leaves were analyzed by the height as top, middle, bottom. Speed sprayer the was most effective on depositing at the middle position, of the leaves. All other sprays the leaces except the dry mist sprinkler were not effective enough to deposit on the back sides. To achieve more deposits on the high position leaves, an improve ment in the nozzle and an efficient power system of sprayer were needed.

A Study on the Plastic deformation Absorption Characteristics of Aluminum-Polyethylene Composite Structure Sprinkler Pipe (알루미늄 합성수지 복합 구조 스프링클러 파이프의 변위 흡수 특성 연구)

  • Kim, Jun-Gon;Kim, Kwang-Beom;Noh, Sung-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.426-433
    • /
    • 2019
  • After an earthquake, fire and gas explosions are more likely to cause more casualties in cities with many apartment buildings and large complex buildings. In order to prevent this, seismic design is necessary for the fire protection sprinkler system. However, most systems currently use stainless-steel pipes, although synthetic resin pipes are used in some special places. These materials are susceptible to vibration and earthquakes. This study evaluated the displacement absorption flexibility of polyethylene (PE) and aluminum (Al) multi-layered composite pipes to increase the seismic performance in a vibration environment and during earthquakes. The seismic performance was compared with that of a stainless-steel and PE pipes. The seismic characteristics can be measured by measuring the amount and extent of vibration transmitted by the sprinkler pipe. This method can be used to judge the seismic characteristics to attenuate the vibration during an earthquake. The seismic characteristics of the pipe were verified by comparing the logarithmic attenuation rate to the initial response displacement of the vibration generated by the transverse vibration measurement method.

Experimental study on smoke-logging phenomenon caused by sprinklers during a compartment fire (구획 화재시 스프링클러에 의한 스모크-로깅현상에 관한 실험적연구)

  • Kwon, Young-Jin;Yoon, Ung-Gi;Seo, Dong-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.121-122
    • /
    • 2014
  • This study contemplated the descending air current from the smoke layers related to the smoke logging phenomenon in the sprinkler applied design for effective evacuation safety design. As a result, database on the average particle diameter, particle velocity and distribution of sprinkling was obtained and the relationship between the water amount and particle diameter was obtained. Also, in relation to descending air current, the movement of smoke layer to the bottom at the descending air current velocity of 0.6m/s was observed and stable descending air current was observed in existence of fire source over 100kW in size.

  • PDF