  • We studied on the design of a sprinkler control system that communicates with the administrator's mobile through a wireless communication network and a sprinkler unit that sprays water on the vegetation area. This sprinkler control system consists of a communication module that receives an operation signal for the operation of the sprinkler unit from the administrator's mobile, and a control module that controls the sprinkler unit according to the operation signal received through the communication module. It is also designed to control sprinkler units by measuring temperature, humidity, light intensities, vibration and field images in the vegetation area in real time through sensors and camera for each of them and comparing them with established limit criteria. The sprinkler allows the administrator to control the sprinkler more easily because the administrator operates the sprinkler through the mobile from a distance, and emergency situations occur and can respond quickly.

청정실 화재의 시뮬레이션 II. 제연설비와 스프링클러설비의 필요성 (Simulation of a Clean Room Fire II. Needs of Smoke Control System and Springkler System)

  • 박외철;이만근;박헌식
    • 한국화재소방학회논문지
    • /
    • 제20권2호
    • /
    • pp.8-13
    • /
    • 2006
  • 제연설비와 스프링클러설비의 필요성을 확인하고 연기확산 가능성을 조사하기 위해 청정실 화재의 시뮬레이션을 수행하였다. 바닥면적 $39m{\times}13m$, 높이 4 m의 작업구역에 1MW의 메탄올 화재가 발생했을때, 제연설비와 스프링클러설비의 정상작동과 작동실패에 따른 연기누출 여부를 조사하였다. 제연설비가 정상적으로 작동하는 경우에는 스프링클러설비에 관계없이 연기가 안전하게 배출됨을 알 수 있었다. 화재확산과 연기발생을 억제하고 발생한 연기를 신속히 배출하기 위해 스프링클러설비가 필요하며, 스프링클러설비와 제연설비가 신속하게 작동할 수 있도록 신뢰도가 높은 스프링클러설비 헤드와 자동화재탐지설비가 필요함을 확인하였다.

수리계산 적용을 위한 스프링클러설비의 화재안전기준 개선방안 연구 (An Improvement Study on National Fire Safety Code of Sprinkler System for Hydraulic Calculation Application)

  • 이근오;강주형
    • 한국안전학회지
    • /
    • 제22권1호
    • /
    • pp.7-12
    • /
    • 2007
  • There are two kinds of design process for sprinkler system. one is pipe schedule system and the other is hydraulically designed system. We have inefficient results when we design by hydraulically designed system because the design process for sprinkler system is restricted by domestic fire code. Therefore, it is essential to do an introduction of hydraulically designed system which is based on engineering for enhancing reliability and efficiency of sprinkler system. This study presents points at issue by comparing and studying design standards of sprinkler system from Korea, Japan and NFPA, and presents improvement plans of national fire safety code of sprinkler system by processing, comparing and analyzing designs according to piping schedule and hydraulically designed system about domestic objects. Installation standards of sprinkler system have to be applied not by object buildings but by hazard classification. It is hard to design an efficient sprinkler system for fire control when water supply requirement of sprinkler systems allocated according to a size of a building because the same purpose but other buildings may request more water requirement or less. We should sublate the pipe schedule system from national fire safety code and need to introduce the hydraulically designed system. The pipe schedule system presents easy access because it is based on the forecasted engineering calculations but it is applied to only small buildings like NFPA due to its low reliability.

스프링클러시스템을 이용한 밤나무흑벌 방제에 관한 연구 (Use of Sprinkler System for Control of Dryocosmus kuriphilus on Chestnut Orchards)

  • 정상배
    • 한국자원식물학회지
    • /
    • 제19권5호
    • /
    • pp.598-601
    • /
    • 2006
  • 밤나무림내에 sprinkler system을 고정 설치하고, 이를 이용하여 적정한 시기에 일시에 그리고, 간편하게 약제를 살포함으로써 밤나무의 주요해충인 밤나무흑벌(Dryocosmus kuriphilus)의 피해를 효과적으로 방제할 목적으로 2003년부터 2년간 경남 산청군 신안면에서 본연구가 수행되었다. 공시약종은 carbaryl 50% WP, 1,500배액을 사용하였으며, 얻어진 결과는 다음과 같다. 밤나무흑벌 성충의 우화시기는 6월 중순부터 7월 중순까지 약35일간이며, 우화최성기는7월상순의 약 5일간이었다. 밤나무흑벌의 우화 및 산란시기에 Carbaryl 50% WP 1,500배액의 수관살포는 밤나무흑벌에 탁월한 방제효과가 있었다. 즉 매일살포구의 평균 충영형성율은 3.0%, 2일간격 살포구의 평균 충영형성율은 12.8%로서 이들은 무처리구의 평균충영형성율 82.9%와 비교하여 각각 96.4% 및 84.5%의 높은 방제효과가 인정되었으며 수관부위별로는 차이가 없었다.

언어표현 기반의 북미 정상회담에 관한 한미 신문사설의 비교 (A Comparison between Korean and English News Editorials with Focus on U.S.-North Korea Summit Based on Expressive Language)

  • 노보경;반현
    • 문화기술의 융합
    • /
    • 제5권3호
    • /
    • pp.125-130
    • /
    • 2019
  • 2019년 하노이에서 열린 체 2차 북미회담은 공동 합의를 도출하지 못한 채 결렬되었다. 본 논문은 마틴과 화이트(2005)의 평가어 체계를 근간으로 총 8개의 사설들, 구체적으로는 4개의 주요 미국 언론들의 사설들과 4개의 한국 언론들의 사설들을 평가어들을 포함한 언어적 표현들을 중심으로 분석하였다. 분석 결과 뉴욕타임즈, USA투데이, 워싱턴 포스트, 월스트리트 저널의 사설들 중 월스트리트 저널을 제외한 3개의 언론들은 모두 회담 결렬의 원인을 트럼프 대통령 개인으로 귀속시키며 부정적 평가어로 입장을 전달함을 알 수 있었다. 그러나 4개의 신문 사설에서는 한반도의 비핵화나 평화에 대한 우려에 대한 내용을 담고 있지 않았다. 반면 한국의 언론들은 모두 회담 결렬의 원인보다는 향후 방향에 대해 중점을 두고 있었는데, 두 언론은 부정적 행위평가어를 이용하여 문제점과 우려를 제기했지만, 다른 두 언론은 한겨레신문과 경향신문은 향후 대응과 입장에 중심을 두었고 부정적 평가어보다는 당부와 조언의 언어적 자원을 활용하고 있음이 밝혀졌다. 이를 통해, 담론 소비에 있어 양국의 언론들은 각자의 입장을 전달하는 데 있어 부정적인 평가어를 선호한다는 점, 그리고 기대와 당부를 전달할 때는 평가어보다는 보조 용언과 같은 언어적 표현을 사용한다는 것을 알 수 있었다.

개방식우사내 Fan과 Sprinkler설치가 착유우의 생리적 변화 및 유생산성에 미치는 영향 (Effects of Sprinkler and Fan Cooling System in Loose Barn on the Physiological Parameter and Milk Productivity in Holstein Cows During Summer)

  • 정태영;이현민;김종민;김동일;이연섭;이인형
    • 한국축산시설환경학회지
    • /
    • 제2권1호
    • /
    • pp.41-52
    • /
    • 1996
  • 고온다습한 여름철에 우사내 fan + sprinkler에 의한 방서대책이 Holstein착유우의 생리적 반응, 유생산성 및 유조성분 등에 미치는 영향을 조사한 결과는 다음과 같다. 1 외기 온도가 가장 높은 15:00시에 측정한 대조구와 처리구의 건구 온도, 상대 습도, 이슬점 온도 및 수증기압 등은 각각 30.15 : 30.4$0^{\circ}C$, 71.44 : 70.82%, 24.32 : 24.26$^{\circ}C$, 30.51 : 30.50mbar로 fan + sprinkler설치가 기상 조건에 영향을 미치지는 않았다. 2. 피부온도는 대조구(34.02$^{\circ}C$)에 비하여 fan + spinkler 처리구(32.96$^{\circ}C$)가 유의하게 저하되었다(P<0.05). 또한 직장온도도 대조구가 41.21$^{\circ}C$, 처리구가 39.53$^{\circ}C$로 대조구에 비해 처리구에서 유의하게 낮았다(P<0.05). 3. 혈청 Cortisol 농도는 대조구가 1.44$\mu\textrm{g}$/dL로 처리구의 0.90$\mu\textrm{g}$/dL 보다 유의하게 높았다(P<0.05). 4. 평균 산유량은 대조구가 23.66kg, 처리구가 25.87kg으로 대조구에 비해 처리구가 유의하게 증가하였으며(P<0.05), 시험축을 유기별로 나누어 유량을 조사한 바 대조구 보다 처리구가 비유초기, 중기 및 후기에서 각각 8.16%, 2.83% 및 12.14%의 증가를 보였으나 유의차는 없었다. 5. 우유중 유당, 유단백 및 무지고형분 등의 함량 및 생산량은 대조구와 처리구간에 차이가 없었다. 그러나 유지방 함량의 경우 대조구가 3.22%, 처리구가 3.37%로 처리구가 0.15% point 증가했으나 유의차는 없었다. Fan + sprinkler가 설치된 시설에서 사육된 젖소에서 생산된 우유내 체세포수는 대조구에 비해 26.63%가 감소되었으나 유의차는 발견할 수 없었다. 이상의 시험 결과에서 볼 때 fan + sprinkler를 이용한 방서 방법은 고온 stress를 완화시켜 유생산성의 증가에 기여할 수 있는 하나의 방법이라고 본다.

  • PDF

스프링클러시스템을 이용한 잣나무 채종원의 구과해충 방제에 관한 연구 (Application of Sprinkler System for Control of Cone Insects on Korean Pine, Pinus koraiensis Seed Orchard)

  • 송병민;권건형;정상배
    • 한국자원식물학회지
    • /
    • 제19권1호
    • /
    • pp.93-96
    • /
    • 2006
  • In order to prevent cones from being damaged by cone insects, Gravitarmata margarotana and Dioryctria abietella, sprinkler system was installed on the Pinus koraiensis Seed Orchard. Such a test was conducted at Chung-ju, Chungcheong buk-do, Korea in 2002. Insectides of Diflubenzuron 25% WP ${\times}2,500$ and Cyfluthrin 2%EC ${\times}\;1,000$ were sprayed at fifteen-day and twenty-day intervals during the period of insects adult occurrence by sprinkler system. The Gravitarmata margarotana generally emerged for about 53 days from middle April to early June, and peak emergence was 10 days from April 20 to April 30. Dioryctria abietella generally emerged for about 108 days from late April to early August, and peak emergence was 10 days from May 20 to May 30. Damage rate of cones were $8.7{\sim}9.7%$ and $10.9{\sim}12.7%$ on average with crown insecticide spraying with Cyfluthrin and Diflubenzuron, while 67.5% when not treated. Control effectiveness of this insecticide spraying was $85.6{\sim}87.1%$ and 83.9%와 81.2%, respectively. When it considers the forest environment, it is recommended diflubenzuron which is low toxic pesticide. In conclusion, effectual times and number of diflubenzuron 25% WP application with sprinkler system against cone insects were from early May through late August and six times at twenty-day interval.

간이스프링클러 설비의 소화성능 향상에 관한 실험적 연구 (An Experimental Study on Improvement of Fire Extinguishing Performance of Basic Sprinkler System)

  • 허민녕;신창섭
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.46-51
    • /
    • 2018
  • A basic sprinkler system is a fire extinguishing system that can be easily installed in a fire-vulnerable place such as a publicly used establishments. However, the publicly used establishments are not only complicated in structure, but also have a large amount of flammable interior materials, and the users are not normally in a normal state, which is a very dangerous fire-fighting object. Therefore, due to the low fire extinguishing performance of the basic sprinkler system installed in the publicly used establishments, the fire suppression control can not be performed quickly in case of fire, which may increase the life and property damage. In this study, the cases of quantitative changes of extinguishing water used in basic sprinkler system and the cases of addition of additives such as wetting agents, reinforced agents to improve extinguishing performance were compared. Experimental results showed that the extinguishing performance was improved as the quantity of extinguishing water increase and the reinforced agents showed similar performance to that of 60% increase in the amount of extinguishing water. The cooling time to $200^{\circ}C$ and oxygen concentration were improved up to 14.3% and 34.5%, respectively. In the case of using the wetting agent, the cooling time to $200^{\circ}C$ and oxygen concentration did not show any significant improvement, but showed the effect of preventing deep seated fire. In order to prevent loss of life and property, it is necessary to improve the performance of the basic sprinkler system by increasing amount of extinguishing water or using additives like reinforced agents.

Developments in Fire Sprinkler Technology

  • Rice, Douglas
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.606-609
    • /
    • 1997
  • Technology in fire sprinklers has exploded. There is more private fire sprinkler research now than ever before. New technology in fire sprinklers has tested the existing standard and found that it was wrong in some cases, it has provided new sprinklers that control fire better while reducing the cost of the overall system. This expansion of the types and applications of fire sprinklers has created a great need for education for the Authorities Having Jurisdiction and the Engineer as they must be able to make informed decisions regarding this new technology. Significant research has been done at Factory Mutual Research Corporation and Underwriters Laboratory in the United States. Full scale fire testing is done to prove any new technology did not lower the level of protection of existing fire sprinkler system installations. In each and every case, the existing level of fire protection was the baseline against which the new sprinklers were tested. This level can not be lowered for the test to be considered a success. This is intended to be an overview of the developments in fire sprinklers. Although extensive detail is not included, the overall aspects of these developments can be discussed. The research that will be covered will include the following general subjects: high piled and rack storage sprinkler protection without in-rack sprinklers, extended coverage and quick response sprinklers for ordinary and light hazard occupancies, as well as special sprinklers and their applications.

  • PDF

살수장치(撒水裝置)를 이용(利用)한 복숭아명나방 방제(防除)에 관(關)한 연구(硏究) (Use of Sprinkler System for Control of Peach Pyralid Moth, Dichocrocis punctiferalis on Chestnut Orchard)

  • 정상배
    • 한국산림과학회지
    • /
    • 제94권4호통권161호
    • /
    • pp.277-280
    • /
    • 2005
  • 밤나무재배지 내에 살수장치를 고정 설치하고, 이를 이용하여 일시에 약제를 살포함으로써 밤나무의 중요 종실해충인 복숭아명나방(Dichocrocis punctiferalis)의 피해를 효과적으로 방제할 목적으로 2002년에 경기도 여주군 장천면에서 연구가 수행되었다. 공시약종은 fenitrothion 50% EC 1,000배액 및 diflubenzuron 25% WP 2,500배액을 사용하였으며, 얻어진 결과는 다음과 같다. 복숭아명나방의 2세대 성충우화시기는 7월 상순부터 9월 상순까지 약 60일간이며, 우화최성기는 7월 하순부터 8월 상순의 약 10일간이었다. 살수장치(스프링클러)에 의한 수관약제살포는 관행의 지상약제살포와 비교하여 아주 효율적이었다. Diflubenzuron 25% WP 2,500배의 수관살포는 무처리의 피해율 30.4% 와 비교하여 2.3%(0.9-4.0%)로서 92%(86.7-97.0%)이상의 높은 방제효과가 있었다. 복숭아명나방에 대한 적정약제 살포시기 및 살포횟수는 7월 상순부터 8월 하순까지 10-15일 간격으로 4-5회 살포하는 것이 효과적이었다.