Design and Development of Sprinkler Control System Utilizing Mobile with IoT

  • Kang, Tae-Sun;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.212-217
    • /
    • 2020
  • We studied on the design of a sprinkler control system that communicates with the administrator's mobile through a wireless communication network and a sprinkler unit that sprays water on the vegetation area. This sprinkler control system consists of a communication module that receives an operation signal for the operation of the sprinkler unit from the administrator's mobile, and a control module that controls the sprinkler unit according to the operation signal received through the communication module. It is also designed to control sprinkler units by measuring temperature, humidity, light intensities, vibration and field images in the vegetation area in real time through sensors and camera for each of them and comparing them with established limit criteria. The sprinkler allows the administrator to control the sprinkler more easily because the administrator operates the sprinkler through the mobile from a distance, and emergency situations occur and can respond quickly.

Simulation of a Clean Room Fire II. Needs of Smoke Control System and Springkler System (청정실 화재의 시뮬레이션 II. 제연설비와 스프링클러설비의 필요성)

  • Park, Woe-Chul;Lee, Man-Geun;Park, Hun-Sik
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.8-13
    • /
    • 2006
  • Numerical simulations were carried out for a fire in a clean room to confirm needs of a smoke control system and a sprinkler system, and to investigate a possible smoke spread-out. For a 1 MW methanol fire in a space of $39m{\times}13m$ floor and 4 m high, smoke spread-out was scrutinized for failure of the sprinkler system and/or the smoke control system. It was shown that the smoke control system removes smoke safely without the sprinkler system and that the sprinkler system is required to suppress smoke generation and spread of the fire, and to remove the smoke quickly. It was also confirmed that highly reliable sprinkler heads and automatic fire detection system are required for the sprinkler and smoke control systems.

An Improvement Study on National Fire Safety Code of Sprinkler System for Hydraulic Calculation Application (수리계산 적용을 위한 스프링클러설비의 화재안전기준 개선방안 연구)

  • Lee, Keun-Oh;Kang, Joo-Hyeong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.1 s.79
    • /
    • pp.7-12
    • /
    • 2007
  • There are two kinds of design process for sprinkler system. one is pipe schedule system and the other is hydraulically designed system. We have inefficient results when we design by hydraulically designed system because the design process for sprinkler system is restricted by domestic fire code. Therefore, it is essential to do an introduction of hydraulically designed system which is based on engineering for enhancing reliability and efficiency of sprinkler system. This study presents points at issue by comparing and studying design standards of sprinkler system from Korea, Japan and NFPA, and presents improvement plans of national fire safety code of sprinkler system by processing, comparing and analyzing designs according to piping schedule and hydraulically designed system about domestic objects. Installation standards of sprinkler system have to be applied not by object buildings but by hazard classification. It is hard to design an efficient sprinkler system for fire control when water supply requirement of sprinkler systems allocated according to a size of a building because the same purpose but other buildings may request more water requirement or less. We should sublate the pipe schedule system from national fire safety code and need to introduce the hydraulically designed system. The pipe schedule system presents easy access because it is based on the forecasted engineering calculations but it is applied to only small buildings like NFPA due to its low reliability.

Use of Sprinkler System for Control of Dryocosmus kuriphilus on Chestnut Orchards (스프링클러시스템을 이용한 밤나무흑벌 방제에 관한 연구)

  • Chung, Sang-Bae
    • Korean Journal of Plant Resources
    • /
    • v.19 no.5
    • /
    • pp.598-601
    • /
    • 2006
  • In order to prevent chestnut from damaged by the chestnut gall wasp, Dryocosmus kuriphilus, a sprinkler system was installed on the chestnut orchard. Such a test was conducted at Sanchung-gun, Kyeongnam province, Korea in 2003 and 2004. Insecticide of carbaryl 50% WP, x1,500 was sprayed at every day and two-day intervals during the period of D. kuriphilus adult occurrence by sprinkler system. The chestnut gall wasps generally emerged for about 35 days from the middle June to the middle July, and peak emergence was 5 days of early July. Crown application of carbaryl by sprinkler system was found to be highly effective for control of the chestnut gall wasp. Gall formation rate of chestnut were 3.0 and 12.8% on average with crown insecticide spraying at every day and two-day intervals, while 82.9% when not treated. Control effectiveness of this insecticide spraying was 96.4% and 84.6%, respectively.

A Comparison between Korean and English News Editorials with Focus on U.S.-North Korea Summit Based on Expressive Language (언어표현 기반의 북미 정상회담에 관한 한미 신문사설의 비교)

  • Noh, Bokyung;Ban, Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.125-130
    • /
    • 2019
  • This research is about alternative measure of main components for sprinkler system like automatic wet pipe sprinkler system, dry pipe sprinkler system, pre-action sprinkler system, vacuum sprinkler system, deluge sprinkler system, and so on. By replacing the alarm check valve, dry valve, pre-operated valve, and deluge open valve with a solenoid valve, it be can be simplifed the various processes of the manufacturing process into one process, it creates an environment in which one standardized product can be produced simultaneously on a single machine. Therefore, it could improve the price competitiveness of products, reduce the maintenance cost, and help the adaptability of new sprinkler systems in the future. There is a benefit when it comes to apply to sprinkler system. Only replace the valve which is used to control primary and secondary valve such as wet, dry, pre operated, vacuum, deluge system valve. Other components such as retarding chambers, automatic air compressors, accelerators or adjusters, supervisory panels, vacuum pumps, and manual starters can be used as they are, so they can be easily applied to existing sprinkler system. It is needed to legal and institutional study for solenoid valve applied sprinkler system to commercialize.

Effects of Sprinkler and Fan Cooling System in Loose Barn on the Physiological Parameter and Milk Productivity in Holstein Cows During Summer (개방식우사내 Fan과 Sprinkler설치가 착유우의 생리적 변화 및 유생산성에 미치는 영향)

  • 정태영;이현민;김종민;김동일;이연섭;이인형
    • Journal of Animal Environmental Science
    • /
    • v.2 no.1
    • /
    • pp.41-52
    • /
    • 1996
  • This experiment was carried out to study the effect of sprinkler and fan cooling system on the physiological parameter, milk production and milk composition for Holstein cows in hot, humid climates. Thirty cows were assigned to one of two sections of open-sided loose barn. Water nozzles of sprinkler system were spaced in line at 1.2m intervals. Forced air was provided by 85cm diameter fans at rate of 3.4㎥/sec. The results obtained from these experiments are as follows: 1. There was no significant difference in meteorological data between control and fan + sprinkler cooling system(treatment group). 2. Skin temperature and rectal temperature of the treatment group were significantly lower than those of the control group (32.96 : 39.53$^{\circ}C$ vs 34.02 : 41.21$^{\circ}C$ respectively) (P<0.05). 3. Serum cortisol concentration of the treatment group(0.90$\mu\textrm{g}$/dL) was lower than that of control group(1.44$\mu\textrm{g}$/dL)(P<0.05). 4. Milk production of cows cooled with a sprinkler and fan cooling system was significantly higher than that of no cooling system (P<0.0l). 5. Lactose, protein and solid-not-fat content of milk were not changed by the treatments. Milk fat content of the control(3.23%) was low compared with the treatment group(3.38%). Somatic cell count was reduced by 26.63% in the treatment. The results indicate that a sprinkler and fan cooling systems can provide an effective means to relieve heat stress and enhance productivity of lactating Holstein cows during hot and humid summer season.

  • PDF

Application of Sprinkler System for Control of Cone Insects on Korean Pine, Pinus koraiensis Seed Orchard (스프링클러시스템을 이용한 잣나무 채종원의 구과해충 방제에 관한 연구)

  • Song Byong-Min;Kwon Gun-Hyung;Chung Sang-Bae
    • Korean Journal of Plant Resources
    • /
    • v.19 no.1
    • /
    • pp.93-96
    • /
    • 2006
  • In order to prevent cones from being damaged by cone insects, Gravitarmata margarotana and Dioryctria abietella, sprinkler system was installed on the Pinus koraiensis Seed Orchard. Such a test was conducted at Chung-ju, Chungcheong buk-do, Korea in 2002. Insectides of Diflubenzuron 25% WP ${\times}2,500$ and Cyfluthrin 2%EC ${\times}\;1,000$ were sprayed at fifteen-day and twenty-day intervals during the period of insects adult occurrence by sprinkler system. The Gravitarmata margarotana generally emerged for about 53 days from middle April to early June, and peak emergence was 10 days from April 20 to April 30. Dioryctria abietella generally emerged for about 108 days from late April to early August, and peak emergence was 10 days from May 20 to May 30. Damage rate of cones were $8.7{\sim}9.7%$ and $10.9{\sim}12.7%$ on average with crown insecticide spraying with Cyfluthrin and Diflubenzuron, while 67.5% when not treated. Control effectiveness of this insecticide spraying was $85.6{\sim}87.1%$ and 83.9%와 81.2%, respectively. When it considers the forest environment, it is recommended diflubenzuron which is low toxic pesticide. In conclusion, effectual times and number of diflubenzuron 25% WP application with sprinkler system against cone insects were from early May through late August and six times at twenty-day interval.

An Experimental Study on Improvement of Fire Extinguishing Performance of Basic Sprinkler System (간이스프링클러 설비의 소화성능 향상에 관한 실험적 연구)

  • Hur, Min Noung;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.46-51
    • /
    • 2018
  • A basic sprinkler system is a fire extinguishing system that can be easily installed in a fire-vulnerable place such as a publicly used establishments. However, the publicly used establishments are not only complicated in structure, but also have a large amount of flammable interior materials, and the users are not normally in a normal state, which is a very dangerous fire-fighting object. Therefore, due to the low fire extinguishing performance of the basic sprinkler system installed in the publicly used establishments, the fire suppression control can not be performed quickly in case of fire, which may increase the life and property damage. In this study, the cases of quantitative changes of extinguishing water used in basic sprinkler system and the cases of addition of additives such as wetting agents, reinforced agents to improve extinguishing performance were compared. Experimental results showed that the extinguishing performance was improved as the quantity of extinguishing water increase and the reinforced agents showed similar performance to that of 60% increase in the amount of extinguishing water. The cooling time to $200^{\circ}C$ and oxygen concentration were improved up to 14.3% and 34.5%, respectively. In the case of using the wetting agent, the cooling time to $200^{\circ}C$ and oxygen concentration did not show any significant improvement, but showed the effect of preventing deep seated fire. In order to prevent loss of life and property, it is necessary to improve the performance of the basic sprinkler system by increasing amount of extinguishing water or using additives like reinforced agents.

Developments in Fire Sprinkler Technology

  • Rice, Douglas
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.606-609
    • /
    • 1997
  • Technology in fire sprinklers has exploded. There is more private fire sprinkler research now than ever before. New technology in fire sprinklers has tested the existing standard and found that it was wrong in some cases, it has provided new sprinklers that control fire better while reducing the cost of the overall system. This expansion of the types and applications of fire sprinklers has created a great need for education for the Authorities Having Jurisdiction and the Engineer as they must be able to make informed decisions regarding this new technology. Significant research has been done at Factory Mutual Research Corporation and Underwriters Laboratory in the United States. Full scale fire testing is done to prove any new technology did not lower the level of protection of existing fire sprinkler system installations. In each and every case, the existing level of fire protection was the baseline against which the new sprinklers were tested. This level can not be lowered for the test to be considered a success. This is intended to be an overview of the developments in fire sprinklers. Although extensive detail is not included, the overall aspects of these developments can be discussed. The research that will be covered will include the following general subjects: high piled and rack storage sprinkler protection without in-rack sprinklers, extended coverage and quick response sprinklers for ordinary and light hazard occupancies, as well as special sprinklers and their applications.

  • PDF

Use of Sprinkler System for Control of Peach Pyralid Moth, Dichocrocis punctiferalis on Chestnut Orchard (살수장치(撒水裝置)를 이용(利用)한 복숭아명나방 방제(防除)에 관(關)한 연구(硏究))

  • Chung, Sang-Bae
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.4 s.161
    • /
    • pp.277-280
    • /
    • 2005
  • In order to prevent chestnuts from damage by the peach pyralid moth, Dichocrosis punctiferalis, a sprinkler system was installed on the chestnut orchard. Such a test was conducted at Yeoju-gun, Gyeonggi-do, Korea in 2002. Insecticides of fenitrothion 50% EC, x1,000 and diflubenzuron 25% Wp, x2,500 were sprayed at ten-day fifteen-day and twenty-day intervals during the period of D. punctiferalis adult occurrence by sprinkler system. The peach pyralid moths generally emerged for about 60 days from early July to early September, and peak emergence was 10 days from late July to early August. Damage rate of chestnuts were 0.9-4.0% on average with this crown insecticide spraying with diflubenzuron, while 30.4% when not treated. Control effectiveness of this insecticide spraying was 92%(86.7-97.0%). In conclusion, effectual times and number of insecticide application with sprinkle system against peach pyralid moth were from early July to late August and four or five times at ten or fifteen day intervals, respectively.