• Title/Summary/Keyword: Spray volume

Search Result 331, Processing Time 0.03 seconds

Characteristics of Spray Deposit Pattern and Flow Rate in the Air-Center Nozzle System (Air-center nozzle의 분무살포도(噴霧撒布度)와 분무량(噴霧量)의 특성(特性))

  • Lee, Sang Woo;Hur, Yun Kun
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.156-168
    • /
    • 1980
  • The air-center nozzles, being specially designed to supply air into the central part of water stream at seven levels of air volume, were tested for spray deposit pattern and flow-rate at each of the twelve pressure levels ranging from $0.35kg/cm^2$ (5 psi) to $6.33kg/cm^2$ (90 psi) in comparison with those of standard nozzles. The air-center nozzles produced comparatively more stable spray deposit patterns than the standard nozzles. The spray deposit patterns of the air-center nozzle were concentrated gradually in the central region with increase of air volume as a component of spray mixture. The degree of concentration of spray deposit on the central region from the air-center nozzle was higher than that of the standard nozzle, which suggested the possibility of obtaining farther travel distance spraying system at a given performance level. The flow rate of the air-center nozzle was not as much as that of the standard nozzle due to the air within certain limits. The rate of decrease of water flow became smaller with an increase in operating pressure although it changed rapidly in the beginning stage, ranging up to two or three percent of the air flow rate due to the compressive properties of air.

  • PDF

Development of A Boom Sprayer for Effective Pest-and-Disease Control on Densed Paddy Stems (수도(水稻) 기부(基部) 방제용(防除用) 붐-형(型) 주간(株間) 살포(撒布) 장치(裝置) 개발(開發)에 관(關)한 연구(硏究))

  • Chung, Chang Joo;Chang, Young Chang
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.13-23
    • /
    • 1985
  • Spraying method from the paddy-field levee is known to give insufficient penetration of the spray droplets to the rice stem of the densely grown plants, which is generally encountered at the last stage of rice growth. This study was intended to investigate the spraying system to solve this existing problem. As an approach, it was attempted to develop the boom-with-nozzle, between-the-row application system. Several types of nozzles and their different arrangements in the boom were tested in the field to measure the penetration-reaching distance and the uniformity of spray droplet distribution. The results of the study are summarized as follows: 1. Field experiments by the spraying method from the paddy-field levee showed to have practically no penetration of the spray droplets to the portion of the plant stem with the normal flow volume generally applied and thus need for improving present spraying method. 2. It was found that, considering both the uniformity of the spray droplet distribution and performance rate, the most efficient type of nozzle in the between-the-row boom-type spraying system was one that has core-insert hollow-cone with some clearance between the cone and tip. 3. When tested by applying the spraying method of between-the-row, the nozzle pressure did not affect the uniformity of spray droplet distribution. However, the nozzle pressure had a positive effect on the penetrating-reaching distance of the facing side of the rice stem and did not affect much on that of the opposite face of the stem. It was also found that the maximum pressure to affect the penetration-reaching distance was about $10kg/cm^2$. 4. The uniformity of the spray droplet distribution in the between-the-row system was greatly affected by the height and orientation of the nozzles in the boom. Based on experimental work for the different type of the boom-with-nozzle arrangements, it is recommended that the position of nozzle is set at about 0.45 m above the ground and two nozzles in the boom are oriented to be faced with each other with some angle such that the droplet stream from the nozzle would not directly face with each other.

  • PDF

Design Factors of Boom Sprayer(II) -Spray Droplet Size and Coverage Characteristics on Rice Plants- (붐방제기 살포장치의 설계요인 구명을 위한 실험적 연구(II) -노즐의 분무유형 및 벼의 피복특성-)

  • 정창주;김학진;이중용;최영수;최중섭
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.313-322
    • /
    • 1995
  • This study was conducted to find the design factors of spraying device of the boom sprayer for low volume application. Specific objectives of this study were 1) to select proper nozzles for broadcast spraying and row crop spraying by the nozzle spray characterisic experiment, and 2) to investigate the coverage characteristic of rice plant at the row crop spraying. The results of this study are summarized as follows. (1) From the tested results on the droplet diameter spectrum and spray pattern the standard flat-fan nozzle and drift guard nozzle were judged as appropriate for the broadcasting. Even flat-fan nozzle showed similar span values to standard flat-fan nozzles and drift guard nozzle : however, the nozzles were found to be inappropriate for broadcasting because of their spray pattern. Hollow cone nozzle showed relatively small span values and uniform spray pattern. (2) For the upper and lower sides of the rice plants, coverage rates of even flat-fan nozzles and hollow cone nozzles were maximum at the second row, but decreased rapidly after the third row. For the middle side of the rice plants, coverage rates of them were maximum at the first row, but decreased rapidly. When one nozzle was tested, C.V. values were in the range of 90~160% and 60~160% on entire heights of rice plant for even flat-fan nozzles and hollow cone nozzles respectively. C.V. values at other parts were poor. Spray coverage rate at the middle part was improved by overlapping the nozzles whereas there was little difference on the upper and lower part of rice plants. (3) For spraying lower part of rice plant between rows, even flat-fan nozzles and hollow cone nozzle were judged as appropriate, but in order to ensure the uniform coverage, distance between nozzles, recommended to be less than 90cm.

  • PDF

Evaluation of Exposure to Isocyanates Used in Furniture Industry (가구산업에 사용되는 이소시안화물 폭로에 대한 평가)

  • Lee, Su-Gil;Lee, Nae-Woo;Pisaniello, Dino. L
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.138-142
    • /
    • 2006
  • Occupational asthma is commonly known to be induced by isocyanate exposure. Spray painters generally use isocyanates for 2-pack spray painting to coat wooden panel surfaces in the furniture industry in South Australia. Due to a lack of actual exposure data, this study conducted environmental and dermal/ocular monitoring from a company in the furniture industry. According to this study, there was no significant airborne contamination, due to the use of high volume low pressure (HVLP) spray guns, low concentration of hardener in paint solutions and appropriate respirator like full face-air line respirator. There was no significant HDI detection in the general work area around the spray booths. Owing to the use of disposable nitrile gloves during the spray painting, no significant dermal exposure was found. According to color monitoring, there was a possible dermal exposure from surfaces in the workplace, unless either protective gloves were worn or appropriate working practices like clean-up process and storage in a secure places. No eye contamination was detected from the spray painters. No significant exposure levels from inhalational, dermal, ocular were found. The area of most concern was work practices.

Preparation process of functional particles : I. Preparation of microcapsule by spray drying (기능성 미분말의 제조공정에 관한 연구 : I. 분무건조법에 의한 microcapsule 제조)

  • 정철원;허화범;박종현;신건철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.4
    • /
    • pp.521-531
    • /
    • 1996
  • Inorganic and inorganic/organic microcapsules were prepared by spray drying. $K_{4}SO$ and clay were used as the core and colloidal silica as the shell for the inoroganic microcapsules. Forthe inorganic/organic microcapsules were used the inorganic microcapsule which were mentioned above (core) and ethyl cellulose (shell). To characterize the prepared microcapsule for the practical use, the homogenity of surface and pore volume are the dominent factors. At the volume ratio of 0.3/0.7 of core/shell, the spherical and homogeneous surfaces of inorganic microcapsule could be synthesized. In the case of inorganic/organic microcapsules, the weitht ratio was 0.76/0.24. The pore volume of inorganic/organic microcapsules decreases more than that of inorganic microcapsule. The more the amount of shell (ethyl cellulose) in inorganic/organic microcapsules increases, the more the coating became homogeneous and the pore volume decreased.

  • PDF

Autoignition Phenomena of a Single Diesel/1-Butanol Mixture Droplet (디젤/1-부탄올 혼합연료 단일액적의 자발화 현상)

  • Kim, Hyemin
    • Journal of ILASS-Korea
    • /
    • v.23 no.2
    • /
    • pp.90-95
    • /
    • 2018
  • The goal of this study is to experimentally observe the autoignition phenomena of a diesel/1-butanol mixture droplet in ambient pressure and $700^{\circ}C$ condition. A volume ratio of 1-butanol in the fuel was set to 25, 50 and 75%. A single droplet was installed at the tip of fine thermocouple, and the electric furnace dropped down to make elevated temperature condition. Droplet behavior during the experiment could be divided into 3 stages including droplet heating, puffing and autoignition/combustion. Puffing process intensively observed for the case of 1-butanol volume ratio of 25 and 50%, but did not occur at 75%. Increase of 1-butanol volume ratio hindered rise of the droplet temperature and delayed ignition. In addition, puffing process also affected on autoignition, so the ignition delay of 1-butanol volume ratio of 50% was became longer than that of 75% case.

Effect of Orifice Diameter Ratio on Unlike Impinging Jet Mixing (액상 충돌 제트의 혼합에 대한 분사공 직경비의 영향)

  • Lee, S.W.;Cho, Y.H.;Yu, B.I.
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.220-227
    • /
    • 2006
  • Experimental studies has been conducted to investigate the effect of orifice diameter ratio on the mixing characteristics of the split element of doublet and triplet elements. The spray characteristics of non-reacting immiscible liquids have been investigated using a patternator. The local volume fraction is measured by use of mean value of each component. This volume measurement represents the mixing characteristics of the liquid, which affect the overall combustion efficiency. The ratio of the orifice diameter, ranging from 1 to 1.5, and that of the jet-momentum, ranging from 0.5 to 6.0, we used. The jet impinging behavior with use of various ratios exhibits substantially different mixing characteristics. Mixing efficiency is maximized when the jet-momentum ratio is increased; this behavior is particularly prominent when the orifice diameter ratio is greater than unity. The split of the triplet element yields better mixing characteristics and is more effective than that of the doublet element in regard to achieving high combustion efficiency. The optimum mixing factor for the triplet element is found to be 0.75, according to our measurement.

  • PDF

Size Distribution of Droplets Sprayed by an Orchard Sprayer (과수방제기 살포입자의 직경 분포특성)

  • 구영모;신범수;김상헌
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.431-440
    • /
    • 2001
  • Generated agri-chemical droplets by orchard sprayers are evaporated regenerated and transported along wind streams. The droplets are deposited to targets after changing their sizes, affecting the retention of droplets. An orchard sprayer, designed for spraying grapevines was studied on the spatial distribution of droplet size. The experimental variables were spray direction (0, 22.5, 45, 67.5 and 90˚), distance(2.5, 3.0 and 3.5 m) and fan speed (2,075 and 3,031 rpm). Droplet sizes were converted and analyzed from spray stains, sampled using water sensitive papers. The number median diameter (NMD) increased with an increase of the distance due to disappeared fine droplets (<50 ㎛): however, the volume median diameter (VMD) decreased due to shrunken large droplets (>100 ㎛). Fast fan speed delivered large droplets to 3.5 m, but the spatial distributions of NMD and VMD were not uniform. Slower fan speed decreased the possibility of evaporation and drift; therefore, plenty of droplets were maintained up to 3.0 m. The upward blasting distance was limited within 3 m, but the limit to the ground level was extended to 3.5 m. Concentrated wind and droplets to the ground level should be redistributed to upper canopy direction, leading more uniform deposits. High speed wind and system pressure should be avoided because of generating fine droplets, which would be disappeared and drifted away.

  • PDF

Analytical Study on Unsteady Flow Characteristics of Urea-SCR Single Hole Injector depend on Nozzle Shape Change (Urea-SCR 단홀 Injector 노즐형상 변화에 따른 비정상유동특성의 해석적 연구)

  • Hwang, Jun Hwan;Park, Sung-Young
    • Journal of ILASS-Korea
    • /
    • v.24 no.3
    • /
    • pp.105-113
    • /
    • 2019
  • In this paper, a study of Urea-SCR System for Dosing Injector for responding to enhanced environmental regulations has been conducted. There is a limit to the experimental approach due to the structural characteristics of the injector. In order to overcome this problem, The analysis was performed assuming unsteady turbulent flow through computational fluid analysis and the internal flow characteristics of the injector were analyzed. By changing the nozzle shape of the injector, the performance factors of the swirl injector by shape were selected and compared. The design parameters were modified by changing the diameter of the nozzle at a constant ratio compared to the base model. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. The Conv. model to which the taper was applied showed the dominance in mass flow rate, discharge coefficient and swirl because of the smooth fluid flow by shape. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. As a result of the comparison coefficient derivation with those performance parameters for comparing the performance of the model-specific injector, the Conv-140 model with the nozzle diameter expanded by 140% showed the best value of the comparison coefficient.

A Study on the Effect of Atomization of Pressure Nozzle with Blower - Air (압력식 노즐에서 송풍공기가 미립화에 미치는 영향에 관한 연구)

  • Koh, Kyoung-Han;Lim, Sang-Ho
    • Journal of Digital Convergence
    • /
    • v.10 no.5
    • /
    • pp.283-288
    • /
    • 2012
  • This study was undertaken to investigation the spray characteristics of the twin fluid atomization nozzle system. The light oil was injected at the normal temperature and injection pressure was 5 bar - 10 bar by 1 bar and volume flow was 0.5, 1.0 and 2,0 mmH2O(X10-2). We measured the SMD of sprayed droplet to study spray characteristics. The following conclusions were reached from the results of these study. 1. The more injection pressure increased, the more SMD decreased. 2. The more measuring distance between pressure nozzle tip and analyser beam increased, the more SMD increased. 3. SMD of the blower-air-added injection system were shown, increasing volume flow decreased respectively. The result of this study indicated the blower-air-added injection system induced beneficial changes in SMD. And it will be considered important indicator for spray characteristics design and performance evaluation of twin fluid atomization nozzle system.