Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner

  • Lee, Keon-ho;Cho, Dong-woo;Kim, Hyemi;Song, Young-hak
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.101-108
    • /
    • 2017
  • The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.

A Study on the Performance of Heat Exchanger for Closed Cooling Tower (밀폐식 냉각탑용 열교환기의 성능에 관한 연구)

  • Lee, Sang-Sik;Yoo, Seong-Yeon;Kim, Jin-Hyuck;Ahn, Young-Hwan;Park, Hyoung-Joon;Ryu, Hae-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.334-339
    • /
    • 2008
  • An closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The purpose of this study is to evaluate thermal performance of heat exchanger at various conditions and to provide design datebase. The experimental study regarding heat exchanger for closed cooling tower was conducted. Experimental apparatus consists of constant temperature bath, water pump, spray nozzle, heat exchanger, fan, and date acquisition system. Heat transfer rates at various air velocitys, water flow rates, two different spray modes were measured and heat transfer coefficient were calculated to compare the thermal performances. This study provides that the heat transfer coefficient increases with increasing spray water flow rate and with increasing air velocity. The wet mode was more effective than dry mode for closed cooling tower to this study.

  • PDF

The Effect of Nasal Steroid Spray on Contact Granuloma of Larynx (접촉성 육아종 치료에 비강 스테로이드 분무가 미치는 영향)

  • Lee, GilJoon;Ahn, Dongbin;Sohn, Jin Ho
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.29 no.2
    • /
    • pp.79-82
    • /
    • 2018
  • Background and Objectives : Laryngeal contact granuloma is benign inflammatory disease induced by excessive mechanical contact of larynx such as endotracheal intubation, voice abuse, laryngeal microsurgery as well as laryngopharygeal reflux. Because it is caused by various risk factors, multiple treatment modalities are required. The purpose of study is to evaluate treatment effect of topical steroid through nasal cavity in contact granuloma. Materials and Method : Fifty-two patients were enrolled in this study with exception of intubation granuloma. Patients were classified with four groups (Proton pump inhibitor (PPI), Nasal steroid spray (SPR), PPI+SPR, Observation) according to treatment modality. Results : Patients who treated with PPI (Odds ratio 2.45, p=0.03) and combination of PPI and SPR (Odds ratio 2.88, p<0.01) had significantly better response than patients who not treated with medical therapy. Conclusion : Combination therapy of nasal steroid spray and PPI is effective for contact granuloma of larynx and considered as a treatment of choice rather than PPI only treatment.

Ultrasonic Sensor Controlled Sprayer for Variable Rate Liner Applications (초음파센서를 이용한 변량제어 스프레이어)

  • Jeon, Hong-Young;Zhu, Heping
    • Journal of Biosystems Engineering
    • /
    • v.36 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • An experimental variable rate nursery sprayer was developed to adjust application rates for canopy volume in real time. The sprayer consisted of two vertical booms integrated with ultrasonic sensors, and variable rate nozzles coupled with pulse width modulation (PMW) based solenoid valves. A custom-designed microcontroller instructed the sensors to detect canopy size and occurrence and then controlled nozzles to achieve variable application rates. A spray delivery system, which consisted of diaphragm pump, pressure regulator and 4-cycle gasoline engine, offered the spray discharge function. Spray delay time, time adjustment in spray trigger for the leading distance of the sensor, was measured with a high-speed camera, and it was from 50 to 140 ms earlier than the desired time (398 ms) at 3.2 km/h under indoor conditions. Consequently, the sprayer triggered 4.5 to 12.5 cm prior to detected targets. Duty cycles of the sprayer were from 20 to 34 ms for senor-to-canopy (STC) distance from 0.30 to 0.76 m. Outdoor test confirmed that the nozzles were triggered from 290 to 380 ms after detecting tree canopy at 3.2 km/h. The spray rate of the new sprayer was 58.4 to 85.2% of the constant application rate (935 L/ha). Spray coverage was collected at four areas of evergreen canopy by water sensitive papers (WSP), and ranged from 1.9 to 41.1% and 1.8 to 34.7% for variable and constant rate applications, respectively. One WSP area had significant (P < 0.05) difference in mean spray coverage between two application conditions.

A Modeling about Penetration Behavior of Diesel Engine Liquid Fuel Spray (디젤기관의 분무선단 도달거리에 관한 모델링)

  • 안수길;배종욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.140-152
    • /
    • 1989
  • The study on the penetration of sprays during the initial phase of injection period, i.e. ignition delay period, in high speed small D.I. diesel engines are strongly affected by such behavior. To investigate the penetration of the sprays injected through single cylinderical orifice, a mathematical model was developed and compared with experimental results. In this model, radial heterogeneity of fuel density in the spray, transiency of injection pressure difference, and spray outrunning phenomenon were considered simultaneously. Experiments on the behaviors of sprays in the high pressure air chamber were conducted at various injection pressure differences and different levels of back air pressure. The behaviors of sprays injected into the chamber through the conventional Bosch injection pump were visualized with side stroboscopic illumination. Comparison of the experimental results with predictions from the mathematical model confirmed the validity of the model. It was also found that during the initial phase of the injection period the penetration of sprays vs. time appeared to have two transition points; one corresponded to disintegration point of liquid fuel jet, the other to the beginning of steady state injection.

Development of Evaluation of the Locally Made Propeller Type Mistblower

  • Kwangwaropas, Mongkol;Onkong, Narong
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.488-499
    • /
    • 1996
  • A propeller type mistblower was designed and manufactured. The machine consisted of a 770 millimeters diameter propeller driven by the power take off of a tractor. It delivered 26,400 cubic meters of air per hour and has the outlet speed about 180 kilometers per hour. Spray liquid was injected at 30 bars pressure through hollow cone type nozzles which were located around the air outlet of the machine bya poston type pump. Power consumption of the machine was found to be 12.46 kilowatts and the effective forward travel speed was about 2.7 kilometers per hour. Upon spraying mango trees, it was shown that the density of spray partices was about 100 microns and consumed 3.12 liters per tree. Working speed in 6 meters row spacing mango orchard was about one hectare per hour.

  • PDF

A Study on Ice Slurry Production by Water Spray

  • Kim, Byeong-Sun;Lee, Yoon-Pyo;Yoon, Seong-Young;Lee, Jin-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.45-55
    • /
    • 1998
  • A theoretical and experimental study is performed to investigate the characteristics of ice slurry product. By diffusion-controlled evaporation model the possibility of ice slurry is theoretically anticipated. The water vapor evaporated from the surface of droplets is extracted continuously from the chamber by a vacuum pump. The droplet diameter is measured by silicon immersion method. The ice slurry is obtained by spraying droplets of ethylene glycol aqueous solution in the chamber where pressure is maintained under the triple point of water. The droplet with the diameter of 300 $\mu\textrm{m}$and the initial temperature of 2$0^{\circ}C$ was changed into ice particle within the chamber of 1.33m in height.

  • PDF

A study on the spray combustion characteristics in a cylinder of a D.I.diesel engine with the electronically controlled injector (전자제어식 직접분사 디젤 엔진 연소실내의 분무연소 특성에 관한 연구)

  • 정재우;김성중;이기형;선우명호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.2
    • /
    • pp.50-56
    • /
    • 2000
  • It is well known that the combustion phenomenon of diesel engine is an unsteady turbulent diffusion combustion. Therefore, the combustion performance of diesel engine is related to a complex phenomenon which involves the various factors of combustion, such as a injection pressure, injection timing, injection rate, and operation conditions of engine. In this study, the spray and the flame development processes in a single cylinder D.I. diesel visualization engine which uses the electronically controlled injection system were visualized to interpret the complicated combustion phenomenon by using high speed CCD camera. In addition, the cylinder pressure and heat release rate were also obtained in order to analyze the diesel combustion characteristics under several engine conditions.

  • PDF

Breakup Characteristics of Fuel Droplet Including Nanoparticles (나노 입자가 포함된 연료 액적의 분열 특성 연구)

  • Lee, Jae Bin;Shin, Dong Hwan;Lee, Min Jung;Kim, Namil;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.17 no.4
    • /
    • pp.192-196
    • /
    • 2012
  • This paper reports on breakup characteristics of fuel droplet which includes metal nanoparticles. In order to develop a new injection system for nanoparticle-coated layers overcoming the conventional flame spray system, fundamental experiments were conducted to examine the interaction between a fuel droplet with nanoparticles and the external energy induced by the laser. In the experiments, this study used nickel nanoparticles whose size was under 100 nm to mix with kerosene as the fuel, and utilized a syringe pump and a metal needle to inject a fuel droplet. In particular, the Nd-YAG laser was adopted to give additional energy to the nanoparticles for evaporation of a fuel droplet containing nanoparticles. When the laser energy as 96 mJ was irradiated during the injection, it was observed that such an explosive evaporation occurred to break up a fuel droplet including nanoparticles, making the rapid increase in the ratio surface area to liquid volume. From this work, we suggest the possibility that the laser energy can be used for rapid evaporation of a fuel droplet.

A Theoretical Study on Flow and Pressure Variation Characteristics of Fuel Supply System in Diesel Engine (디젤엔진 연료계통의 유동 및 압력 변동특성에 관한 이론적 연구)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.12-23
    • /
    • 1993
  • Combustion phenomenon in diesel engine is mainly governed by characteristics of fuel injection and fuel spray system affected by its dimensions and operating condition. Fuel supply system is consisted of fuel injection pump, high pressure pipe and injection nozzle. In order to develope the more economical diesel fuel injection system, it is in need to carryout the fairly wide range experiments, which is quite impossible. Therefore, theoretical analysis for the numberous parameters is powerful method in this case. In the present study, equations of continuity of fuel oil in fuel injection system are solved to obtain the flow and pressure variation in diesel fuel system affected by injection pump speed, plunger diameter, pipe length and nozzle opening pressure.

  • PDF