• Title/Summary/Keyword: Spray column

Search Result 75, Processing Time 0.022 seconds

Experimental Study of the Effects of Nozzle Hole Geometry for di Diesel Engine (디젤엔진에서 노즐 홀 형상효과의 실험적 연구)

  • Ku, Kun-Woo;Lee, Young-Jin;Kim, In-Su;Lee, Choong-Won
    • Journal of ILASS-Korea
    • /
    • v.12 no.3
    • /
    • pp.154-159
    • /
    • 2007
  • Spray tip penetration and spray angle for one main injection were measured at the atmospheric condition with the fuel injection pressure of 270 bar and 540 bar. It investigates an effect of different nozzle hole geometry of conventional cylindrical one and those of elliptical ones. Injection period represented by injector pulse drive was fixed at 1ms. From the result of this study, it is shown that spray tip penetration becomes shorter and spray angle becomes wider with the elliptical nozzle hole geometry due to fast break-up of a fuel liquid column.

  • PDF

Fire Behavior of Steel Columns Encased by Damaged Spray-applied Fire Resistive Material

  • Kwak, Yoon Keun;Pessiki, Stephen;Kwon, Kihyon
    • Architectural research
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • A Steel column with damaged spray-applied fire resistive material (SFRM) may exhibit reduced structural performance due to the effects of elevated temperature during fire events. Thus, the fire load behavior of steel columns with removed or reduced SFRM needs to be examined to predict the structural damage by fire. FEM analyses were performed for the flange thinning removal models in which the SFRM was reduced as a constant strip in thickness at the top flange of the column. The temperature results for all models obtained from the heat transfer analyses were included as an initial condition in the FEM structural analyses. In this study, the results of analysis show that even small remnants of SFRM led to an effective reduction of temperature at any given fire duration, and improved significantly the axial load capacity of a column as compared to the complete removal cases of SFRM.

Analysis of Spray Mode Using Modified Pinch Instability Theory (핀치이론의 수정 모델을 이용한 스프레이 모드의 해석)

  • Park, Ah-Young;Hammad, Muhammad A.;Kim, Sun-Rak;Yoo, Choong-D.
    • Journal of Welding and Joining
    • /
    • v.27 no.5
    • /
    • pp.88-93
    • /
    • 2009
  • While the pinch instability theory (PIT) has been widely employed to analyze the spray transfer mode in the gas metal arc welding (GMAW), it cannot predict the detaching drop size accurately. The PIT is modified in this work to increase the accuracy of prediction and to simulate the molten tip geometry to be more physically acceptable. Since the molten tip becomes a cone shape in the spray mode, the effective wire diameter is formulated that the effective diameter is inversely proportional to current square. Modifications are also made to consider the finite length of the liquid column and current leakage through the arc. While the effective diameter influences drop transfer significantly, the current leakage has negligible effects. The effects of modifications on drop transfer are analyzed, and the predicted drop diameters show good agreements with the experimental data of the steel wire.

Analysis of Spray Mode Using Modified Pinch Instability Theory (핀치이론의 수정 모델을 이용한 스프레이 모드의 해석)

  • Park, Ah-Young;Hammad, Muhammad A.;Kim, Sun-Rak;Yoo, Choong-D.
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.44-44
    • /
    • 2009
  • While the pinch instability theory (PIT) has been widely employed to analyze the spray transfer mode in the gas metal arc welding (GMAW), it cannot predict the detaching drop size accurately. The PIT is modified in this work to increase the accuracy of prediction and to simulate the molten tip geometry to be more physically acceptable. Since the molten tip becomes a cone shape in the spray mode, the effective wire diameter is formulated that the effective diameter is inversely proportional to current square. Modifications are also made to consider the finite length of the liquid column and current leakage through the arc. While the effective diameter influences drop transfer significantly, the current leakage has negligible effects. The effects of modifications on drop transfer are analyzed, and the predicted drop diameters show good agreements with the experimental data of the steel wire.

  • PDF

An Investigation on the Spray Characteristics of Steady/Plused Jet in Crossflow in Model Ramjet Combustor (모델 램제트 연소기 내에서의 정상/가진 수직 분무 특성 연구)

  • Kim, Jin-Ki;Song, Jin-Kwan;Kim, Min-Ki;Yoon, Young-Bin;Hwang, Yong-Seok
    • Journal of ILASS-Korea
    • /
    • v.13 no.2
    • /
    • pp.99-106
    • /
    • 2008
  • In this study, spray characteristics research of steady/pulsed injection in crossflow was performed experimentally in the model ramjet combustor. High-speed-camera photography was performed through a visualization window of model combustor, and then, steady and pulsed spray structures were observed and analyzed. Varying influx air temperature and fuel species, we could obtain the trajectory correlation in the steady injection case. In the experiment of pulsed injection, it is found that the pulsed frequency hardly influences spray trajectory. Also, it is found that, in the same injection pressure differential, the trajectory correlation of steady condition can be used for estimating pulsed spray trajectory.

  • PDF

Characteristics of Droplet Properties in the Two-Phase Spray into a Subsonic Cross Flow

  • Lee, I.C.;Cho, W.J.;Koo, J.Y.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.358-363
    • /
    • 2008
  • The spray cross-section characteristics of two-phase spray that using external-mixing nozzle injected into a subsonic cross flow were experimentally studied with various ALR ratio that is $0{\sim}59.4%$. Suction type wind tunnel was used and experiments were conducted to ambient environment. Several plain orifice nozzles with L/d of 30 and orifice diameter of 0.5 mm and orifice length 1.5 mm were tested. Free stream velocity profiles at the injection location were measured using hot wire. Spray images were captured to study collision point and column trajectory. Phase Doppler particle analyzer(PDPA) was utilized to quantitatively measuring droplet SMD, volume flux. Measuring probe of PDPA positions was moved 3-way transverse machine. SMD distributions were layered structure and peaked at the top of the spray plume and low value at bottom of the spray. Volume flux of spray was distributed to the two side region and volume flux quantity decreased when ALR ratio increased. It was found that the perpendicularly injected two-phase spray jet of external mixing into a cross flow showing that mistlike spray moved away from the test section bottom region.

  • PDF

Spray characteristics on mixing region scale of twin fluid atomizer (이류체 분사노즐의 혼합영역 형상에 따른 분무특성)

  • 김병문;김혁주;이충원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2147-2159
    • /
    • 1991
  • The effects of principal dimensions of internal mixing twin-fluid atomized and operating conditions on the atomizing characteristics are experimentally investigated. The tests are conducted over the wide range of air/liquid ratio to predict influences of the diameter and length of nozzle, contacting angle between air and liquid in the mixing chamber, and air orifice diameter on the mean drop size(SMD), spray angle, distribution of drop size, and spray dispersion, And also, initial distribution of liquid column by air stream within the mixing chamber are observed through the transparent nozzles. A He-Ne laser particle sizer(MALVERN Model 2604) was used to measure the Sauter.s mean diameter( $D_{321}$) and droplet sizes distribution. In this experiment the air/liquid ratio, mixing length and nozzle diameter have a great influence on SMD, spray angle, droplet sizes distribution and spray dispersion.

Spray Characteristics of Nonimpinging-type Injector According to the Injection Pressure Variation and Angular Direction of Orifices (분사압력 및 분사각에 따른 비충돌형 인젝터의 분무특성)

  • Jung, Hun;Kim, Jong-Hyun;Kim, Jeong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.3
    • /
    • pp.1-8
    • /
    • 2012
  • A water-flow test was carried out for the nonimpinging-type injector to be equipped on 70 N-class liquid-rocket engine under development. Breakup patterns of injector-spray transit from a smooth jet to wavy one as the injection angle increases, whereas spray-breakup lengths are inversely proportional to the injection pressure. It is confirmed that there exist ruffles on the surface of liquid column, which could be caught through the instantaneous spray images captured by high-speed camera. A phenomenon of spray shedding amplified at the specific pressure level of 0.93 MPa was an unexpected behavior of the injected stream and it is to be investigated further.

Spatting Resistance of High Strength RC Column Covering Spray-on Materials of Fiber Composite Spray Mortar(FCSM) (섬유복합모르터의 뿜칠마감에 의한 고강도콘크리트 기둥부재의 폭렬방지)

  • Song Yong-Won;Han Dong-Yeob;Lee Gun-Cheol;Goh Kyoung-Taek;Kim Jin-Soo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.5-8
    • /
    • 2006
  • High strength concrete has been increasingly used in high rue building and it is very obvious re consider fire resistance performance of that. Unlike the normal strength concrete, high strength concrete in sudden elevating temperature at fire is susceptible to spalling with severe explosion and surface split, due to high density of concrete. In order to endure the spalling, inner space temperature of concrete should be control less than certain point. Therefore this study investigated the influence of covering materials on high strength concrete finishing spray-on materials of fiber composite spray mortar(FCSM). Both polypropylene(PP) and polyvinyl alcohol(PVA) fiber were used in this test. Test showed that concrete, covering 18mm mortar containing PVA fiber and confining metal lath 2.3mm thickness, decreased 50% of main bar ambient temperature. compared with control concrete. In addition, concrete covering 18mm mortar without fiber caused falling of covering materials and then it was exposed in elevating temperature. As a result, spatting of the concrete occurred same as control concrete. However, concrete covering spray-on mortar containing PVA or PP fiber resisted spatting occurrence.

  • PDF

Experimental Study of Spray Characteristics of Liquid jet in Cross-flow (횡단류를 이용한 액체제트의 분무 및 분열 특성 실험)

  • Ko Jung-Bin;Lee Kwan-Hyung;Moon Hee-Jang;Koo Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.155-158
    • /
    • 2005
  • The spray characteristics of liquid jet minted in subsonic cross-flow were investigated numerically and experimentally. The behaviors of column, penetration and breakup of plain liquid jet in non-swirling cross-flow of air have been studied. Numerical and physical models are based on a modified KIVAII code. The primary atomization is represented by a wave model based on the KH(Kelvin-Helmholtz) instability that is generated by a high interface relative velocity between the liquid and gas flows. CCD camera has been utilized in oder to capture the spray trajectory. The nozzle diameter was 0.5 mm and its L/D ratios were between 1 and 5. Numerical and experimental results indicate that the breakup point is delayed by increasing gas momentum ratio, the penetration decreases by increasing Weber number and the turbulent or nonturbulent liquid jet is obtained at different L/D ratio.

  • PDF