• Title/Summary/Keyword: Spray Tower

Search Result 26, Processing Time 0.021 seconds

Characteristics of Closed Circuit Cooling Tower with Variation of Tube Diameter (멀티패스 밀폐식 냉각탑의 관경변화 특성)

  • Shim, Gyu-Jin;Lee, Ho-Saeng;Kim, Eun-Pil;Yoon, Jung-In;Kwon, O-Ick
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.531-536
    • /
    • 2008
  • This paper presents experimental result of characteristics about Closed circuit Cooling Tower having a rated 2RT. The experimental apparatus has been set-up with a conventional type system. The test section is heat exchangers of cooling tower that consist of different vertical tubes, 15.88mm with 10 rows and columns and 19.05 mm with 8 rows and 12 columns. The main results were summarized as follows : The values of heat and mass transfer coefficients of cooling tower operating with two paths are higher than these with one path. Cooling capacity per unit volume using 15.88mm tubes are higher than 19.05mm tubes.

  • PDF

Quantitative Analysis of the Impact of Inlet Duct Spray on Scrubbing Efficiency using Experimental Design (실험계획법을 이용한 입구덕트 스프레이의 습식 세정 효율 변화효과 분석 연구)

  • Lee, Minwoo;Kim, Hyun Ho;Koo, Junemo
    • Journal of ILASS-Korea
    • /
    • v.24 no.1
    • /
    • pp.8-14
    • /
    • 2019
  • The purpose of this study is to develop a packing-free wet scrubber to prolong the maintenance interval compared with the conventional packed bed wet scrubbers with which frequent operation stops are unavoidable to clean the packing materials. The main- and interaction-effects were quantitatively analyzed by regression analysis for the measured ammonia scrubbing data from the experiments prepared by experimental design. The scrubbing efficiency of the newly developed wet scrubber was found to be over 95% under the condition of flue gas flow rate of 90CMM and liquid-to-gas ratio $2l/m^3$ for all considered trials of experimental design. The interaction effect between the inlet duct spray and the filter was found to be important, which controls the droplet growth due to the droplet collisions between the duct- and scrubbing tower-spray. The presented methodology to analyze the impacts of operational and design factors on the scrubber efficiency showed potential for applications to optimize the future flue gas abatement process in semiconductor plants.

Preliminary Evaluation of Paecilomyces lilacinus HY-4 to Control Tetranychus urticae

  • Shin, Tae-Young;Lee, Won-Woo;Ko, Seung-Hyun;Ji, Zhen;Shin, Dong-Ha;Son, Kwang-Hee;Park, Ho-Yong;Woo, Soo-Dong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.22 no.1
    • /
    • pp.25-28
    • /
    • 2011
  • The virulence against the two-spotted spider mite, Tetranychus urticae Koch, was evaluated with entomopathogenic fungus Paecilomyces lilacinus (Thom) Samson HY-4 which is isolated from coleopteran insect and registered to Korean and US patents. Virulence tests were conducted with conidial suspensions ($1.5{\times}10^6conidia/ml$) of P. lilacinus HY-4 against T. urticae adults and positive results were recorded in laboratory conditions. The spraying device was also developed for the efficient and exact evaluation of treatment. The developed spraying device was named as SD-tower sprayer and its efficacy of spraying conidia was evaluated. The accumulated mortality caused by P. lilacinus HY-4 using SD-tower spray was about 73% at 6 days after inoculation. This suggest that the isolate P. lilacinus HY-4 may be considered as promising for a new approach to prevent adult infestations by T. urticae.

Mass Transfer from Heat Exchanger for Closed Wet Cooling Tower (밀폐형 냉각탑용 열교환기에서의 물질전달)

  • Yoo, Seong-Yeon;Kim, Jin-Hyuck;Han, Kyu-Hyun;Kim, Joo-Sang;Ryu, Hae-Sung;Park, Hyoung-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1119-1122
    • /
    • 2009
  • The use of cooling towers in the air conditioning systems of buildings is increasing. In closed wet cooling towers, the heat transfer between the air and surface tubes can be composed of the sensible heat transfer and the latent heat transfer. The latent heat transfer is affected by the air and spray water. This study provides a designing methodology of heat exchanger for closed wet cooling tower. The correlation equation was derived to interpret the mass transfer coefficient based on the analogy of the heat and mass transfer and the experimental results. The results from this correlation equation showed fairly good agreement with experimental data.

  • PDF

Characteristics of Closed Circuit Cooling Tower with Multi Path on Cooling Water Inlet Conditions (냉각수 변화에 따른 멀티패스 밀폐식 냉각탑의 성능)

  • Shim, Gyu-Jin;Baek, Seung-Moon;Moon, Choon-Geun;Yoon, Jung-In;Kim, Eun-Pil;Kwon, O-Ick
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.597-602
    • /
    • 2008
  • The experiment of performance about closed-wet cooling tower(CWCT) was conducted in this study. The test section has the cooling water that flows from top part of a heat exchanger that has an entrance of cooling water with one and multi path. The heat exchanger consists of 15.88mm tubes with ten rows and ten columns and staggered arrangement. In this experiment, heat and mass transfer coefficients and range are calculated with variations of cooling water and path. The results indicated that operating CWCT using two path have the high values of heat and mass transfer coefficients and range than one path.

  • PDF

INFLUENCE OF ALR ON DISINTEGRATION CHARACTERISTICS IN PNEUMATIC SPRAY

  • Lee, S.G.;Joo, B.C.;Kim, K.C.;Rho, B.J.
    • International Journal of Automotive Technology
    • /
    • v.1 no.2
    • /
    • pp.95-100
    • /
    • 2000
  • The droplet and the turbulent characteristics of a counterflowing internal mixing pneumatic nozzle mainly focused. The measurements were made using a Phase Doppler Particle Analyzer under the different air pressures. The nozzle with tangential-drilled holes at an angle of 30 to the central axis has been designed. The spatial distributions of velocities, fluctuating velocities, droplet diameters and SMD were quantitatively and qualitatively fluctuating velocities were substantially higher than the radial and the tangential ones. This implies that the disintegration process is enhanced with the higher air pressure. The larger droplets were detected near the spray centerline at the upstream while the smaller ones were generated at the downstream. This was attributed to the lower rates of spherical particles which were not subject to instantaneous breakup. However, substantial increases in SMD from the central part tower spray periphery were predictable in downstream regions.

  • PDF

Experimental Study on the Characteristics of CO2 Capture with Spray Towers Using Ammonia Solution (암모니아수 흡수제를 사용하는 분무탑의 이산화탄소 포집 기본특성에 관한 실험적 연구)

  • Lim, Youngbok;Choi, Munkyoung;Lee, Jinwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.165-172
    • /
    • 2014
  • Experiments were conducted to identify basic characteristics of $CO_2$ capture using a spray tower with a single nozzle. Results were evaluated in terms of $CO_2$ saturation which is the main determining factor of regeneration energy, and capture efficiency under various operating conditions. Changes in the capture efficiency under various conditions are well expressed as a monotone increasing function of the relative solvent $(NH_3):CO_2$ flow rate. Although changes in $CO_2$ saturation are also well described as a function of the $NH_3/CO_2$ flow rate ratio, these are expressed as a monotone decreasing function, in contrast with the increasing function of $CO_2$ efficiency. In recent research on the relationship between $CO_2$ saturation and capture efficiency, $CO_2$ saturation was found to decrease when capture efficiency increased. In conclusion, the results show that the amount of solvent used for achieving high capture efficiencies is excessive, as is the amount of regeneration energy needed.

Emission Characteristics of Metal Elements from a MSW Incinerator (도시폐기물 소각시설에서의 금속배출특성 연구)

  • Kim, Ki-Heon;Kim, Sam-Cwan;Song, Geum-Ju;Seo, Yong-Chil
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • The behavior and characteristics of heavy metals at different streams in a MSWI(Municipal Solid Waste Incinerator) with a capacity of 100tonnes/day were investigated by measuring the concentration of heavy metals and gases and analyzing their leaching data from ashes. Metal components of Cr, Cu, Cd and Pb were in higher concentrations in the fly ashes collected after the water spray tower than in the bottom ashes. It was due to condensation by a lower temperature with water spray cooling. Metal contents in the bottom ash became higher for finer particles as expected. The mass balance of heavy metals in different stream was estimated from the analyzed data in bottom ash and collected dusts at different locations. For the lower volatility of metals such as Pb, Cu, Cr, 88-97% of them remained in the bottom ash, while Cd and Hg escaped from the combustor with remaining in bottom ash of 18.4 and 0.8%, respectively. In most cases the leaching rate of fly ash showed higher values than that of bottom ash, with the their average acidities of 9.8 and 11.9 respectively.

  • PDF

Atmospheric Stability Evaluation at Different Time Intervals for Determination of Aerial Spray Application Timing

  • Huang, Yanbo;Thomson, Steven J.
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.337-341
    • /
    • 2016
  • Purpose: Evaluation of atmospheric conditions for proper timing of spray application is important to prevent off-target movement of crop protection materials. Susceptible crops can be damaged downwind if proper application procedure is not followed. In our previous study, hourly data indicated unfavorable conditions, primarily between evening 18:00 hrs in the evening and 6:00 hrs next morning, during clear conditions in the hot summer months in the Mississippi delta. With the requirement of timely farm operations, sub-hourly data are required to provide better guidelines for pilots, as conditions of atmospheric stability can change rapidly. Although hourly data can be interpolated to some degree, finer resolution for data acquisition of the order of 15 min would provide pilots with more accurate recommendations to match the data recording frequency of local weather stations. Methods: In the present study, temperature and wind speed data obtained at a meteorological tower were re-sampled to calculate the atmospheric stability ratio for sub-hour and hourly recommendations. High-precision evaluation of temperature inversion periods influencing atmospheric stability was made considering strength, time of occurrence, and duration of temperature inversion. Results and Discussion: The results indicated that atmospheric stability could be determined at different time intervals providing consistent recommendations to aerial applicators, thereby avoiding temperature inversion with minimal off-target drift of the sprayed liquid.