• 제목/요약/키워드: Spray Column

검색결과 75건 처리시간 0.021초

Compressive behavior of circular hollow and concrete-filled steel tubular stub columns under atmospheric corrosion

  • Gao, Shan;Peng, Zhen;Wang, Xuanding;Liu, Jiepeng
    • Steel and Composite Structures
    • /
    • 제33권4호
    • /
    • pp.615-627
    • /
    • 2019
  • This paper aims to study the compressive behavior of circular hollow and concrete-filled steel tubular stub columns under simulated marine atmospheric corrosion. The specimens after salt spray corrosion were tested under axial compressive load. Steel grade and corrosion level were mainly considered in the study. The mechanical behavior of circular CFST specimens is compared with that of the corresponding hollow ones. Design methods for circular hollow and concrete-filled steel tubular stub columns are modified to consider the effect of marine atmospheric corrosion. The results show that linear fitting curves could be used to present the relationship between corrosion rate and the mechanical properties of steel after simulated marine atmospheric corrosion. The ultimate strength of hollow steel tubular and CFST columns decrease with the increase of corrosion rate while the ultimate displacement of those are hardly affected by corrosion rate. Increasing corrosion rate would change the failure of CFST stub column from ductile failure to brittle failure. Corrosion rate would decrease the ductility indexes of CFST columns, rather than those of hollow steel tubular columns. The confinement factor ${\xi}$ of CFST columns decreases with the increase of corrosion rate while the ratio between test value and nominal value shows an opposite trend. With considering marine atmospheric corrosion, the predicted axial strength of hollow steel tubular and CFST columns by Chinese standard agree well with the tested values while the predictions by Japanese standard seem conservative.

충격파관 장치설계를 위한 유동현상의 해석(1)-계산치와 실험치의 비교- (An Analysis of Flow Phenomena in Shock Tube System Design(I)-Comparison of Experimental and Computation Result-)

  • 정진도;수곡행부
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1218-1226
    • /
    • 1994
  • The shock tube is a useful device for investigating shock phenomena, spray combustion, unsteady gas dynamics, etc. Therefore, it is necessary to analyze exactly the flow phenomena in shock tube. In this study, the mechanics of its reflected shock zone has been investigated by using of the one-dimensional gas dynamic theory in order to estimate the transition from initial reflection of shock wave region. Calulation for four kinds of reflected shock tube temperature (i.e. (a) 1388 K (b) 1276 K (c) 1168 K (d) 1073 K) corresponding to the experimental conditions have been carried out sumarized as follows. (1) The qualitative tendency is almost the same as in that conditions in region of reflected wave region. (2) High temperature period (reflected shock wave temperature) $T_{5}$, exists 0-2.65 ms. (3) Transition period from temperature of reflection shock wave is far longer than the calculated one. This principally attributed to the fact that the contact surface is accelerated, also, due to the release of energy by viscoity effect. This apparatus can advance the ignition process of a spray in a ideal condition that involved neither atomization nor turbulent mixing process, where, using a shock tube, a column of droplets freely from atomizer was ignited behind a reflected shock.

횡단류에 분사되는 액체 제트의 분무 및 연소 특성 (Spray and Combustion Characteristics of Liquid Jet in Cross Flow)

  • 이관형;김두만;구자예;황진석
    • 한국항공우주학회지
    • /
    • 제34권12호
    • /
    • pp.48-58
    • /
    • 2006
  • 횡단류에 분사되는 액체 제트의 분무 및 연소 특성에 대한 수치적 연구를 수행하였다. 수치 계산을 위해 3차원의 분무 및 화학반응 유동 해석에 유용한 KIVA 코드를 횡단류에서의 분무 해석에 적합하도록 수정하여 사용하였다. 액주의 분열과 리거먼트 및 액적의 분열 현상을 해석하기 위하여 wave 모델과 KH-RT hybrid 모델이 사용되었다. 침투길이는 유입공기의 속도가 감소하거나 분사속도가 증가함에 따라 증가하였다. 유입공기의 속도가 증가할수록 계산결과의 오차가 크게 발생함을 알 수 있었다. 연소 특성에 대한 수치 해석으로 연소실 내부의 화염전파 형상과 국부지역에서의 온도및 공해 배출량에 대한 결과를 얻었다.

Web Spray 법을 이용한 복합 양이온교환섬유의 제조 및 암모니아 흡착특성 (Preparation of Hybrid Cation Ion Exchange Fibers by Web Spray and Their Adsorption Properties for Ammonia Gas)

  • 박승욱;이후근;이영우;정부영;황택성
    • 폴리머
    • /
    • 제31권6호
    • /
    • pp.479-484
    • /
    • 2007
  • 본 연구는 점착제 분사방식으로 고성능 hybrid ion exchange fiber(HIEF)를 제조하고 이들의 암모니아 흡착성능 및 기본물성을 측정하였다. HIEF의 이온교환용량은 수지 부착량이 증가함에 따라 증가하였으며 단일 수지와 이온교환섬유의 이온교환용량보다 크게 나타났다. 또한 암모니아의 제거율은 HIEF의 충전밀도가 증가할수록 증가하였으며 흡착 파과시간은 270분으로 섬유나 수지에 비해 길게 나타났고 최대 암모니아 흡착량은 94%이었다. 또한 암모니아 흡착 파과시간은 유량 및 농도가 증가함에 따라 빠르게 진행되었다. 암모니아 반응속도 상수(k)는 유입되는 가스농도의 증가에 따라 증가하였으며, 질량이 증가할수록 감소하였으며 가스 유속이 증가할수록 반응속도 상수(k)가 증가하였다.

축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향 (Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

HPLC/DAD/ESI-MS 및 고체상 추출법을 이용한 뇨시료중 갑상선 호르몬 분석 (Determination of thyroid hormones by solid-phase extraction using high performance liquid chromatograph/diode array detector/electro-spray ionization mass spectrometry in urine samples)

  • 곽선영;문명희;표희수
    • 분석과학
    • /
    • 제19권6호
    • /
    • pp.519-528
    • /
    • 2006
  • 본 연구에서는 뇨시료를 고체상 추출법으로 추출한 후 HPLC/DAD/ESI-MS(high-performance liquid chromatograph/diode array detector/electro-spray ionitation mass spectrometry)를 사용하여 분석하였다. 7종의 thyroid hormones의 HPLC 분리조건은 Hypersil ODS(octadecylsilica) 컬럼(4.6mm I.D., 100 mm length, particle size $5{\mu}m$)을 사용하고 ammonium formate buffer와 acetonitrile을 이동상으로 하여 기울기 용리한 결과 완전 분리가 가능하였으며, UV spectra 및 질량스펙트럼을 확인할 수 있었다. 고체상 추출법에 의한 전처리 최적 조건을 조사한 결과 시료를 pH 3으로 한 후 C18 고체상을 사용하여 4 mL의 methanol/ammonium hydroxide(9:1) 혼합용액으로 용리할 경우 회수율이 89.0-113.1%로 나타났다. HPLC/DAD를 이용하여 10-1000 ng/mL범위에서 검량선을 작성한 결과 $r^2$값은 0.992-0.998 으로 나타났으며 검출한계는 2-4 ng/mL(3.8-13.0 pmol/mL)로 계산되었다.

Simultaneous Determination of Phenobarbital, Pentobarbital, Amobarbital and Secobarbital in Raw Milk via Liquid Chromatography with Electron Spray Ionization Tandem Mass Spectrometry

  • Tian, Huaixiang;Zhou, Xingxin;Chen, Chen;He, Yabin;Yu, Haiyan;Zheng, Xiaoping
    • 한국축산식품학회지
    • /
    • 제37권6호
    • /
    • pp.847-854
    • /
    • 2017
  • A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of four barbiturates (phenobarbital, pentobarbital, amobarbital and secobarbital) in raw milk. The barbiturates were extracted using liquid-liquid extraction, ultrasonication and centrifugation, and purified on an SPE column. Analytes were separated by HPLC on a CSH C18 column eluted using an acetonitrile-water system with a linear gradient dilution programme, and detected by MS/MS. The recoveries of the barbiturates were 85.0-113.5%, and the intra- and inter-assay RSDs were less than 9.8% and 7.3%, respectively. The limit of detection was 5 ng/mL for all four of the barbiturates. The analytical method exhibited good linearity from 10 to 1000 ng/mL; the correlation coefficient ($r^2$) was greater than 0.9950 for each barbiturate. This method was also applied to the determination of barbiturates in real milk samples and was found to be suitable for the determination of veterinary drug residues in raw milk.

축하중을 받는 내화피복 CFT기둥의 온도분포 특성 (Characteristics of Temperature Distribution of Axially Loaded CFT Column with Fire Protection)

  • 김해수;윤성기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권4호
    • /
    • pp.78-85
    • /
    • 2010
  • 화재발생시 콘크리트충전 강관(CFT)기둥은 강재의 표면이 고열에 직접 노출되기 때문에 강관의 내화피복에 따라 내화성능에서 많은 차이가 예상된다. 본 연구에서는 내화피복 CFT기둥의 온도분포특성을 파악하기 위하여 내화피복의 종류와 두께 및 내화시간을 변수로 하여 실험을 실시하였다. 실험결과 가열온도를 기준으로 내화성능은 내화뿜칠, 내화페인트, 무내화의 순으로 나타났다. 가열시간-위치별 온도분포는 콘크리트부분은 완만한 증가를 보이고 있으나, 강관외부표면에 도달하면 급격한 온도의 증가를 보이는 것으로 나타났다.

수직 간섭된 램공기 대류에 의한 충돌 분무의 미립화 촉진에 관한 연구 (Spray characteristics of impinging sprays introduced into the strongly convective flow)

  • 이상승;윤웅섭
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.384-394
    • /
    • 2005
  • Important characteristics of impinging sprays intersected by a strongly convective gaseous cross flows were experimentally investigated. The breakup processes due to different Weber and Reynolds numbers of liquid and gas streams were visually examined with quantitative measurements of breakup lengths, penetration heights, and droplet sizes. Snapshot images and spay data evidenced that, at lower jet Reynolds number the breakup processes portrays the atomization profiles similar to typical column breakup of single orifice jet. At higher jet Reynolds numbers, disintegration of jet stream is significantly expedited by strong momentum transported from strongly convective gaseous stream. The breakup length and penetration height decreased as the convective flow increase. From the bottom the wall up, the SMD measured the centerline increase. The maximum SMD appeared the top of the SMD distribution

  • PDF

오리피스 형상에 따른 단공노즐 액체제트의 유동특성 (Effect of Orifice Geometry on Flow Characteristics of Liquid Jet from Single Hole Nozzle)

  • 송윤호;황동현;안규복
    • 한국추진공학회지
    • /
    • 제21권5호
    • /
    • pp.19-28
    • /
    • 2017
  • 본 연구에서는 원형 노즐과 타원형 노즐을 이용하여 공동현상과 수력튀김 현상이 유동특성에 어떠한 영향을 미치는지 파악하고자 하였다. 이를 위해 오리피스 길이 대 직경비(L/d)와 타원형 노즐의 종횡비(a/b)가 서로 다른 분사기들을 제작하여 분무실험을 수행하였다. 분사압력 증가에 따라 공동현상이 발생할 경우 유량계수가 서서히 감소하였으나 수력튀김 영역에서는 유량계수가 급격히 떨어진 후 일정한 값을 유지함을 확인하였다. 하지만 타원형 노즐에서 장축지름(a)과 단축지름(b) 대비 오리피스 길이의 비인 L/b가 8 이상, L/a가 8 이하인 경우, 유량계수 및 액체제트 형상은 기존의 원형 노즐과는 상당히 다른 결과를 나타내었다. 정상유동 상태인 경우 타원형 노즐에서 분사된 액주는 원형 노즐과는 달리 하류로 가면서 장축에서는 분무각이 감소하였으며 단축에서는 분무각이 커지는 모습을 보였다.