• Title/Summary/Keyword: Spot size

Search Result 547, Processing Time 0.032 seconds

Predictors of renal scars in infants with recurrent febrile urinary tract infection: a retrospective, single-center study

  • Han, Jae Ha;Rhie, Seonkyeong;Lee, Jun Ho
    • Childhood Kidney Diseases
    • /
    • v.26 no.1
    • /
    • pp.52-57
    • /
    • 2022
  • Purpose: To determine predictive factors for detecting renal parenchymal damages (RPDs) in infants with recurrent febrile urinary tract infection (fUTI). Methods: From January 2015 to December 2021, 102 infants with recurrent fUTI and who underwent 99mTc-dimercaptosuccinic acid (DMSA) renal scan in our hospital were included in this study. Controls included infants with normal DMSA results performed 3 months apart from the 2nd episode of fUTI. DMSA-positive group included infants with positive DMSA results performed 3 months apart from the 2nd episode of fUTI or at the 3rd episode of fUTI. The recurrence rate, causative bacteria, renal size discrepancy of both kidneys, and laboratory findings including C-reactive protein (CRP) and spot urine sodium-to-potassium ratio (uNa/K) were compared between both groups. Results: Only 3.8% of 79 infants with a 2nd episode of fUTI showed positive DMSA results. fUTI recurred more frequently within 12 months of follow-up in the DMSA-positive group than in the control group (69% vs. 13%, P<0.001). CRP values were significantly higher in the DMSA-positive group than in the control group (7.3 mg/dL vs. 3.7 mg/dL, P<0.001). Spot uNa/K were significantly lower in the DMSA-positive group than in the control group (0.6 vs. 1.1, P<0.001). Conclusions: Congenital renal scar and RPDs on the DMSA scan were more frequently found in infants with recurrent fUTI than those in the control group. High CRP values and low spot uNa/K in acute infections were helpful in predicting the presence of RPD in infants with recurrent fUTI.

Periodontal health status, oral microbiome, white-spot lesions and oral health related to quality of life-clear aligners versus fixed appliances: A systematic review, meta-analysis and meta-regression

  • Ana Sandra Llera-Romero;Milagros Adobes-Martin;Jose Enrique Iranzo-Cortes;Jose Maria Montiel-Company;Daniele Garcovich
    • The korean journal of orthodontics
    • /
    • v.53 no.6
    • /
    • pp.374-392
    • /
    • 2023
  • Objective: Assess and evaluate the different indicators of oral health-related quality of life (OHRQoL) among patients treated with clear aligners (CAs) versus those treated with conventional fixed orthodontics (FAs). Methods: An electronic search was performed on the database is Web of Science, Scopus, and Embase databases. Randomized and non-randomized control trials, cross-sectional, prospective cohort and retrospective trials were included. Quality was assessed with risk of bias tool and risk of bias in non-randomised studies. Meta-analyses were performed with random effects models, estimating the standardized and non-standardized mean differences, odds ratio and risk ratio as the measure of effect. The effect on time was determined using a meta-regression model. Results: Thirty one articles were included in the qualitative synthesis and 17 in the meta-analysis. CAs had a significantly lower negative impact on QoL, with an "important" effect size, while the influence of time was not significant. Periodontal indicators plaque index (PI), gingival index (GI), probing depth (PD), and bleeding on probing show significantly better values in patients treated with CAs, with moderate to large effect sizes. PI and GI have a significant tendency to improve over time. In microbiological indicators, CAs present a lower biofilm mass without differences in the percentage of patients with high counts of Streptococcus mutans and Lactobacilli bacteria. The risk of white spot lesion onset is ten times lower in carriers of CAs. Conclusions: Patients wearing CAs show better periodontal indicators, less risk of white spot development, less biofilm mass and a better QoL than patients with FAs.

A Study on the Optimization of IR Laser Flip-chip Bonding Process Using Taguchi Methods (다구찌법을 이용한 IR 레이저 Flip-chip 접합공정 최적화 연구)

  • Song, Chun-Sam;Ji, Hyun-Sik;Kim, Joo-Han;Kim, Jong-Hyeong;Ahn, Hyo-Sok
    • Journal of Welding and Joining
    • /
    • v.26 no.3
    • /
    • pp.30-36
    • /
    • 2008
  • A flip-chip bonding system using IR laser with a wavelength of 1064 nm was developed and associated process parameters were analyzed using Taguchi methods. An infrared laser beam is designed to transmit through a silicon chip and used for transferring laser energy directly to micro-bumps. This process has several advantages: minimized heat affect zone, fast bonding and good reliability in the microchip bonding interface. Approximately 50 % of the irradiated energy can be directly used for bonding the solder bumps with a few seconds of bonding time. A flip-chip with 120 solder bumps was used for this experiment and the composition of the solder bump was Sn3.0Ag0.5Cu. The main processing parameters for IR laser flip-chip bonding were laser power, scanning speed, a spot size and UBM thickness. Taguchi methods were applied for optimizing these four main processing parameters. The optimized bump shape and its shear force were modeled and the experimental results were compared with them. The analysis results indicate that the bump shape and its shear force are dominantly influenced by laser power and scanning speed over a laser spot size. In addition, various effects of processing parameters for IR laser flip-chip bonding are presented and discussed.

CNT-BASED FIELD EMISSION X-RAY SOURCE

  • Kim, Hyun Suk;Lee, Choong Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.433-433
    • /
    • 2016
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission. CNT yarns have demonstrated its potential as excellent field emitters. It was demonstrated that a small focal spot size was achieved by manipulating some electrical parameters, such as applied bias voltage at the mesh gate, and electrostatic focal lenses, geometrical parameters, such as axial distances of the anode, and the electrostatic focal lens from the cathode assembly, and the dimension of the opening of the electrostatic lens. Electrical-optics software was used to systematically investigate the behavior of the electron beam trajectory when the aforementioned variables were manipulated. The results of the experiment agree with the theoretical simulation results. Each variable has an individual effect on the electron beam focal spot size impinging on the target anode. An optimum condition of the parameters was obtained producing good quality of X-ray images. Also, MWCNT yarn was investigated for field emission characteristics and its contribution in the X-ray generation. The dry spinning method was used to fabricate MWCNT yarn from super MWCNTs, which was fabricated by MW-PECVD. The MWCNT yarn has a significant field emission capability in both diode and the triode X-ray generation structure compared to a MWCNT. The low-voltage-field emission of the MWCNT yarn can be attributed to the field enhancing effect of the yarn due to its shape and the contribution of the high-aspect-ratio nanotubes that protrude from the sides of the yarn. Observations of the use of filters on the development of X-ray images were also demonstrated. The amount of exposure time of the samples to the X-ray was also manipulated. The MWCNT yarn can be a good candidate for use in the low voltage field emission application of X-ray imaging.

  • PDF

Analysis of the Effects of Laser Shock Peening under Initial Tensile Residual Stress Using Numerical Analysis Method (수치해석기법을 이용한 초기 인장잔류응력에 대한 레이저 충격 피닝 효과 분석)

  • Kim, Juhee;Lee, Jongwoo;Yoo, Samhyeun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.608-619
    • /
    • 2017
  • In this paper, the effects of parameters related to the residual stress induced due to laser shock peening process to determine mitigation of the initial tensile residual stresses are discussed, such as the maximum pressure, pressure pulse duration, laser spot size and number of laser shots. In order to estimate the influence of the initial tensile residual stresses, which is generated by welding in 35CD4 50HRC steel alloy, the initial condition option was employed in the finite element code. It is found that $2{\times}HEL$ maximum pressure and a certain range of the pressure pulse duration time can produce maximum mitigation effects near the surface and depth, regardless of the magnitudes of tensile residual stess. But plastically affected depth increase with increasing maximum pressure and pressure pulse duration time. For the laser spot size, maximum compressive residual stresses have almost constant values. But LSP is more effective with increasing the magnitudes of tensile residual stress. For the multiple LSP, magnitudes of compressive residual stresses and plastically affected depths are found to increase with increasing number of laser shots, but the effect is less pronounced for more laser shots. And to conclude, even though the initial tensile residual stresses such as weld residual stress field are existed, LSP is enough to make the surface and depth reinforcement effects.

Resonant Transmission of a Rectangular Waveguide Probe with H-type Small Aperture (H-형태 소형 개구를 가진 직사각형 도파관 탐침의 공진 투과)

  • Ko, Ji-Hwan;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.12
    • /
    • pp.1198-1204
    • /
    • 2013
  • As a microwave near field probe for near field scanning optical microscope(NSOM) system, H-shaped(ridge type) small aperture is proposed and its performances from the viewpoints of the transmission efficiency(transmission cross section) and spatial confinement(beam spot size) are compared with those of the previous narrow rectangular aperture type. While the transmission efficiencies are comparable to each other for the two structures, the transmitted beam spot size for the proposed H-shaped aperture is much smaller than that for the previous rectangular aperture. This strong point of the H-shaped aperture is expected to significantly improve near-field optical applications such as optical data storage, nanolithography and nanomicroscopy. It is also observed that the transmission efficiency can be improved if the coupling aperture is implemented in the type of the transmission cavity.

A Development of Intelligent Decision System by Safely Distance of GAS Storage Tank (가스 저장탱크 안전거리의 지적 결정 시스템 개발)

  • Leem Sa-Hwan;Huh Yong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.721-726
    • /
    • 2006
  • This paper is on intelligent decision system by safety distance of gas storage tank(IDSG). The safety distance fixed up by law is used to prevent from the injury by explosion of storage tank on the spot. However, it is not easy for a layman to decide a proper safety distance considering the size, shape and place of the storage tank. Therefore, this thesis shows the user-friendly intelligent decision system which a layman can decide the Bas related law, the size, shape and place of the storage tank by the intelligent decision, and it is to make assurance doubly sure for safety supervision on the spot. Also, the paper can make the data for the damage influence distance of overpressure by the explosion of the storage tank calculated by the scaling law of Hopkinson with the fixed distance by law, and safety range can be grasped with the graphic which is printed by the PHAST(Process Hazard Analysis Software Tool) model using this data.

  • PDF

Photosensitive Materials for Bit-Type 3D Optical Memory (비트타입 3차원 광메모리용 저장매체 연구)

  • Lee, Myeong-Gyu;Kim, Eun-Gyeong;Im, Gi-Su
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.223-224
    • /
    • 2007
  • 광기록의 역사는 1980년대초 Sony와 Philips가 공동 개발한 CD (compact disc: 640MB)의 출현으로부터 시작하여 1996년의 DVD (digital versatile disc: 4.7GB)를 거쳐 최근의 BD (Blu-ray disc: >20GB)에까지 이르고 있다. Read-only memory, recordable, rewritable 등 다양한 저장 및 재생방식이 존재하는데, 이는 레이저 조사에 의한 기록매체의 특성변화의 가역성 (reversibility)에 의존하므로 저장 및 재생방식에 따라 저장매체 또한 다르게 된다. 기록용량의 증가는 레이저의 파장이 짧아지고 동시에 사용된 렌즈의 개구수 (NA: Numerical aperture)가 증가함에 따른 빔 spot size의 감소에 기인한다. 회절한계를 극복하여 빔의 spot size를 줄이고자 하는 연구는 현재도 전세계적으로 활발히 이루어지고 있고 이러한 노력의 일환으로 어느 정도의 추가적인 저장용량 증가는 가능할 수 있으나, 2차원 방식으로는 대용량 광정보기록 (수백 GB ${\sim}$ TB급)의 실현은 불가능하다는 것이 일반적인 예상이다. 한편 장기적으로 기존의 2차원 정보기록방식을 대체하고 저장용량을 획기적으로 증가시킬 수 있는 bit-type 3차원 광정보기록의 개념이 1990년을 전.후로 처음으로 제시되었다. 이는 2차원 bit 정보가 수십 내지 수백 개의 다층 (multi-layer) 형태로 기록되는 방식인데, 그동안 산업체의 관심이 상대적으로 높지 않았던 이유는 영화, 음악 등 엔터테인먼트 시장성 확대를 위해 Blu-ray disc나 HD-DVD에 대한 연구개발에 치중해왔기 때문이다. 하지만 최근 급변하는 정보시스템 서비스 환경 속에서 정보유통량이 기하급수적으로 증가하고 있고 개인이 취급하는 정보량도 2010년경에는 수백 GB 단위가 될 것으로 예상되고 있으며 디지털 방송, 네트워크를 기반으로 한 서비스 수요 뿐 만 아니라 전자도서관이나 VOD (Video on Demand) 서비스 사업에 필수적인 수 TB급의 대용량 저장장치에 대한 수요 또한 크게 증가할 것으로 전망된다. 이에 따라 점차 그 물리적 한계에 다다르고 있는 기존의2차원 정보저장방식을 대체하고 저장용량을 획기적으로 증가시킬 수 있는3차원 정보기록(> $10^{13}$ $bits/cm^3$)에 대한 필요성이 대두된다.

  • PDF

A X-ray Tube Using Field Emitter Made by Multi-walled Carbon Nanotube Yarns

  • Kim, Hyun-Suk;Castro, Edward Joseph D.;Kwak, Seung-Im;Ju, Jin-Young;Hwang, Yong-Gyoo;Lee, Choong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.392-392
    • /
    • 2011
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission.$^{1,2}$ CNT yarns have demonstrated its potential as excellent field emitters.$^3$ Extensive simulations were carried out in designing a CNT yarn-based cathode assembly. The focal spot size dependence on the anode surface of the geometric parameters such as axial distance of the electrostatic focus lens from the cathode and the applied bias voltages at the cathode, grid mesh and electrostatic focus lens were studied. The detailed computer simulations using Opera 3D electromagnetic software$^4$ had revealed that a remarkable size of focal spot under a focusing lens triode type set-up design was achieved. The result of this optimization simulation would then be applied for the construction of the CNT yarn based micro-focus x-ray tube with its field emission characteristics evaluated.

  • PDF

Anthracnose of Spiraea prunifolia Caused by Colletotrichum gloeosporioides in Korea (Colletotrichum gloeosporiodies에 의한 조팝나무 탄저병)

  • Kwon, Jin-Hyeuk;Lee, Chan-Jung;Park, Chang-Seuk
    • The Korean Journal of Mycology
    • /
    • v.33 no.1
    • /
    • pp.35-37
    • /
    • 2005
  • Anthracnose symptoms on Spiraea prunifolia were observed around the residential area of Dongbumyon, Geoje City, Gyeongnam Province, Korea in 2002 and 2003. Typical symptoms of the disease were dark red spot on the leaves and black spot on the stem. The pathogen formed gray to dark gray colony on potato dextrose agar. Conidia were single celled, color, ovoid or oblong in shape and $6{\sim}12\;{\times}\;3{\sim}5\;{\mu}m$ in size. Seta were dark brown in color, cone-shaped in shape and $23{\sim}42\;{\times}\;2{\sim}4\;{\mu}m$ in size. The optimum temperature for growth of the isolate was about $25{\sim}30^{\circ}C$. On the basis of mycological characteristics and pathogenicity test on host plants, the fungus was identified as Colletotrichum gloeosporioides. This is the first report on the anthracnose of S. prunifolia caused by C. gloeosporioides in Korea.