• Title/Summary/Keyword: Spot Intensity

Search Result 165, Processing Time 0.027 seconds

Estimation of Link-Based Traffic-Related Air Pollutant Emissions and the Exposure Intensity on Pedestrian Near Busy Streets (유동인구 밀집지역 인근의 도로구간별 배출량 산정 및 보행자 노출 강도 평가)

  • Lee, Sangeun;Shin, Myunghwan;Lee, Seokjoo;Hong, Dahee;Jang, Dongik;Keel, Jihoon;Jung, Taekho;Lee, Taewoo;Hong, Youdeog
    • Journal of ILASS-Korea
    • /
    • v.23 no.2
    • /
    • pp.81-89
    • /
    • 2018
  • The objective of this study is to estimate the level of exposure of traffic-related air pollutants (TRAPs) on the pedestrians in Seoul area. The road network's link-based pollutant emission was calculated by using a set of mobile source emission factor package and associated activity information. The population information, which is the number of pedestrian, was analyzed in conjunction with the link-based traffic emissions in order to quantify exposure level by selected 23 spots. We proposed the Exposure Intensity, which is defined by the amount of traffic emission and the population, to quantify the probability of exposure of pedestrian. Link-based traffic NOx and PM emissions vary by up to four times depending on the location of each spot. The Hot-spots is estimated to be around 1.8 times higher Exposure Intensity than the average of the 23 selected spots. The information of Exposure Intensity of each spot allows us to develop localized policies for air quality and health. Even in the same area, the Exposure Intensity over time also shows a large fluctuation, which gives suggestions for establishing site-specific counter-measures.

Magnetic resonance images of ameloblastoma

  • Kim Jae-Duk;Kim Jin-Soo
    • Imaging Science in Dentistry
    • /
    • v.35 no.4
    • /
    • pp.207-213
    • /
    • 2005
  • Purpose: To classify and describe the characteristic features of MRI of some ameloblastoma variants. Materials and Methods: The MR images, CT images, and panoramic radiographs in 5 cases were retrospectively examined as follows. First, the contents of ameloblastomas were devided into two portions of either solid or cystic components on the basis of MR signal intensities. The signal intensity within the solid or cystic portions was classified as homogeneous or heterogeneous. Next, the characteristic internal feature of the lesion on T1W1 or T2WI was described. The signal intensities were classified into low, intermediate, slightly high, high, and strong high signal intensity. Results: Unicystic lesion showed homogeneous high signal intensity (SI) on T2W2 and the rim enhancement of the surrounding area including the mural nodule and the thick wall except the central portion on Gd- T1W1. Solid type revealed heterogeneous and high SI area with strong high SI area on T2W2. On Gd- T1W1, the area corresponding to the low signal spot on T1W1 and the strong high signal spot on T2W1 showed low SI. Hybrid type showed slightly enhanced capsular structures and low SI for the round bony septa and the areas connecting the mixed and cystic lesions on T2Wl and Gd-T1W1. Conclusion: MRI could easily assess the relationship between the mixed and cystic findings in ameloblastoma.

  • PDF

An Improved Remote Sensing Image Fusion Algorithm Based on IHS Transformation

  • Deng, Chao;Wang, Zhi-heng;Li, Xing-wang;Li, Hui-na;Cavalcante, Charles Casimiro
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.3
    • /
    • pp.1633-1649
    • /
    • 2017
  • In remote sensing image processing, the traditional fusion algorithm is based on the Intensity-Hue-Saturation (IHS) transformation. This method does not take into account the texture or spectrum information, spatial resolution and statistical information of the photos adequately, which leads to spectrum distortion of the image. Although traditional solutions in such application combine manifold methods, the fusion procedure is rather complicated and not suitable for practical operation. In this paper, an improved IHS transformation fusion algorithm based on the local variance weighting scheme is proposed for remote sensing images. In our proposal, firstly, the local variance of the SPOT (which comes from French "Systeme Probatoire d'Observation dela Tarre" and means "earth observing system") image is calculated by using different sliding windows. The optimal window size is then selected with the images being normalized with the optimal window local variance. Secondly, the power exponent is chosen as the mapping function, and the local variance is used to obtain the weight of the I component and match SPOT images. Then we obtain the I' component with the weight, the I component and the matched SPOT images. Finally, the final fusion image is obtained by the inverse Intensity-Hue-Saturation transformation of the I', H and S components. The proposed algorithm has been tested and compared with some other image fusion methods well known in the literature. Simulation result indicates that the proposed algorithm could obtain a superior fused image based on quantitative fusion evaluation indices.

Effect of the Incident Optical Spot Size Upon the Quadrant Photodetector on the Optical Displacement Detection Sensitivity (4분할 광 검출기 상의 광점 크기가 변위 측정감도에 미치는 영향)

  • Lee, Eun-Joong;Lee, Jin-Woo;Kouh, Tae-Joon
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.2
    • /
    • pp.71-74
    • /
    • 2008
  • In this paper, we have measured the effect of the optical spot size, incident upon the quadrant photodetector, on the optical displacement sensitivity of the optical beam deflection technique. We have built an optical displacement detection system based on the optical beam deflection method using 3 mW He-Ne laser and measured the displacement sensitivity with changing the optical spot size on the quadrant photodetector. We have also calculated the changes in the optical displacement sensitivity as a function of the incident laser spot size by modeling a circular optical spot with constant laser intensity. Our experimental and theoretical studies show that the optical displacement sensitivity increases with the decrease in the optical spot size. This suggests that in the design of the optical motion detection systems with sub-nanometer sensitivity, the displacement sensitivity can be optimized by reducing the size of the incident optical spot on the detector.

A Study on the Application and Dispersion Characteristics Analysis of Surface SH-wave Mode (표면 SH파 모드의 분산특성 해석과 그 응용)

  • 이상용;박익근;윤종학;노승남;안형근
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.61-65
    • /
    • 2001
  • A new flaw detection technique using by SH angle beam method has been discussed. The SH-wave is horizontally polarized shear wave and the surface SH wave has a characteristic of traveling along near surface layer. The surface SH wave technique is valuable for the detection of fatigue cracks at fillet weld heels which cannot be detected by other ultrasonic technique such as angle beam technique and The dispersion curves of it has simple characterization. In this work, using these beneficial chraterization, quality evaluation of spot weld with ultrasonic sound intensity of SH-wave passing through nugget area of spot weld are verified experimentally.

  • PDF

Fatigue Crack Behavior of Triple Piece Spot by Crack Tip Opening Angle of Welded Specimen (3중 점용접재의 귤열단 열림각(CTOA)을 이용한 피로균열거동)

  • Song, Sam-Hong;Joo, Dong-Ho;Yang, Yun-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.74-83
    • /
    • 2001
  • In this study, internal fatigue crack initiation and propagation behavior were investigated by triple piece spot welded specimen. To estimate fatigue life of the specimen varied with shape and thickness, Crack tip opening angle(CTOA) correlated with stress intensity factor was used as the stiffness parameter. The relation between fatigue life and CTOA can be arranged by the quantitative equation for each specimen by experiment. In addition, the variation of stress distribution was solved and the effect on fatigue crack behavior was examined by finite element method(FEM).

  • PDF

Dynamic Fracture Behavior at the Spot Welding Plate (점용접된 판에서의 동적 파괴 거동)

  • Cho Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.314-318
    • /
    • 2006
  • This study is to analyze the intensity of welding part by simulating the dynamic procedure during the fracture of plates with spot welding. The upper and tower plates attached with spot welding can be seen to fall apart at the elapsed time of 0.64 ms after the upper plate is stretched from the lower plate. The maximum von Mises stress is shown at the welding part in the mid of upper and lower plates. The internal energy decreases largely and the kinetic energy increases suddenly near the elapsed time of 0.64 ms when welding part breaks down. The sliding energy decreases with step-by-step style as the time elapses. The value of this energy becomes 0 at the elapsed time of 0.2 ms and on the contrary, two plates stick each other as this value becomes a minus after this time.

  • PDF

Changes in the Polypeptide Patterns of Oat Root Tips Exposed to Alachlor (Alachlor에 의한 귀리 근단(根端) 분열조직(分裂組織)의 단백질(蛋白質) Pattern의 변이(變異))

  • Kwon, S.W.;Park, K.I.;Kim, J.C.
    • Korean Journal of Weed Science
    • /
    • v.12 no.4
    • /
    • pp.368-373
    • /
    • 1992
  • The effect of alachlor treatment on protein synthesis was studied. Protein synthesis was inhibited by $1{\times}10^{-4}$ M and $1{\times}10^{-3}$M of alachlor 5.8% and 86.5%, respectively, while did not occur blow $1{\times}10^{-5}$M alachlor. Soluble protein of alachlor treated oat root tips was examined by polyacrylamide gel electrophoresis. The proteins extracted from oat root tips showed that they were made up of subunits blow 100 kd polypeptides by SDS-PAGE. As compared to control, high molecular proteins(above 47 kd) were inhibited of oat root treated with alachlor, while low molecular proteins(below 23 kd) were increased. Two-D gels showed that alachlor caused decrease(1-6 spots) or increase(7-10 spots) in number of polypeptides on silver staining. The intensity of some polypeptides of soluble proteins (molecular mass of 83 kd : 1, 2 spots, 70 kd : 3, 4 spots, and 47.5 kd : 5, 6 spots) decreased in alachlor treatment, whereas the intensity of other peptide bands (20 kd : 7 spot and 16 kd : 8, 9, 10 spots) increased. Oat root tip proteins present in the neutral zone are masked by diffusing of major proteins, but proteins in acid zone are resolved minor proteins.

  • PDF

Estimation of Specular Light Power by Adjusting Incident Laser Power for Measuring Mirror-Like Surface Roughness (경면 거칠기 측정을 위해 레이저 입사 강도 조정에 의한 정반사 광량 추정 알고리즘 개발)

  • 서영호;김주년;안중환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.94-101
    • /
    • 2004
  • From the Beckmann's reflection model of wave incident, reflected light from a surface is known to have not only specular but also diffuse components. The specular component dominant a surface for a mirror-like surface is distributed on the almost the same area as the spot on the surface, but the diffuse component region dominant f3r a rough surface spreads scattered on the larger areas than the spot. Therefore, statistic parameters from the scattered light distribution are more meaningful in the diffuse region, while the magnitude of rather meaning in the specular region. In usual, there need two sensors to acquire two kinds of information: Photo-detector for light intensity magnitude and image sensor for light intensity distribution. But dual sensor scheme requires a beam splitter usually to feed light to each sensor, and moreover there is not a combination rule to relieve the different sensor characteristics. In this study a new method is proposed for acquisition of the dual information using only an image sensor. Specular region is established on an image area being distinguished from a diffuse component, and laser power is adjusted so that no pixel of the image sensor in the specular region is saturated. Simulation based on the light reflection theory and the experimental results are quite well matched, and thus the proposed method was proved to be very useful for mirror-like surface measurement.

Development of Low-Temperature Storage Method of Sweet Persimmons (단감의 저온저장방법(低溫貯藏方法) 개발(開發)에 관(關)한 연구(硏究))

  • Chung, J.H.;Suh, S.R.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.3
    • /
    • pp.232-246
    • /
    • 1994
  • This study was conducted to develop the long-tenn storage method to minimize the black spot occurred on the surface of persimmons stored in the films at low temperature. The storage experiments were done with different films and persimmon varieties at $0^{\circ}C$ storage condition for 5 months, and then the physical and chemical characteristics of persimmons were tested monthly. The results were as follows : 1. The film 160 made from zeolites showed highest performance in well storings sweet persimmons for 5 months, compared with other films by eyesight. The initial moisture condensation inside the films seemed to cause the black spots on persimmons, and the effect of the film holes was never significant to prevent the black spots. 2. The sugar content was ranged from $14^{\circ}Brix$ to $15^{\circ}Brix$ regardless of film types and persimmom varieties, and it changed little for storage of 5 months. 3. The decrease rate of persimmom weight in the film 160 and 180 was 0.3% for storage of 5 months, while those in other films reached to 2%. The decrease rate of persimmon weight was least in the film 160 and 180. 4. The hardness of Fuyu least decreased in the films 160 and 380. It was changed from 36 kg/cnf to 8-27 $kg/cm^2$, and that of Charyang was from 31 $kg/cm^2$ to 8-10 $kg/cm^2$ for storage of 5 months. The hardness of Charyang rapidly decreased as storage period increased. 5. The average rate of black spot(defect rate) of Fuyu measured by a computer image processing system was least in the film 160 by 0.5%, but those in other films was ranged from about 5% to 20% for storage of 5 months. The rate of black spot of Charyang was less than that of Fuyu among most of films. 6. The intensity, hue, and saturation in persimmon color changed according to storage period. Especially, the intensity of persimmon colors decreased as storage period increased, but it was least in the film 160. 7. An integrated long-term storage method of sweet persimmons was suggested in the basis of the experiments and literature reviews.

  • PDF