• Title/Summary/Keyword: Split-type

Search Result 398, Processing Time 0.024 seconds

Improvement of uniformity in chemical vapor deposition of silicon carbide using CFD (탄화규소 화학기상증착 공정에서 CFD를 이용한 균일도 향상 연구)

  • Seo, Jin-Won;Kim, Jun-Woo;Hahn, Yoon-Soo;Choi, Kyoon;Lee, Jong-Heun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.6
    • /
    • pp.242-245
    • /
    • 2014
  • In order to increase the thickness uniformity in chemical vapor depositon of silicon carbide, we have carried out CFD studies for a CVD apparatus having a horizontally-rotated 3-stage susceptor. We deposited silicon carbide films of 3C-SiC phase showing quite uniform thickness between stages but not uniform one in the stage. The cause of this nonuniformity is thought to be originated from the high rotational speed. And the uniformity between stages can be further increased with the $120^{\circ}$ split type nozzles from CFD results. Through the formation of silicon carbide film on graphite substrates we can make oxidation-resistant and dust-free graphite components with high hardness for the semiconductor applications.

A Survey of the Current Child Care Practices of Professional Working Mothers (전문직 취업모의 자녀관리 현황조사)

  • Lee, Young
    • Korean Journal of Child Studies
    • /
    • v.7 no.1
    • /
    • pp.1-23
    • /
    • 1986
  • The present study investigated the current child care practices of professional working mothers in Korea and their needs for substitute child care outside the home. Three hundred twenty-two professional working mothers who have children under 6 years of age in Seoul, Pusan, Taegu, and Taejon were surveyed with the use of a questionnaire. It was found that during their working hours, most of the professional working mothers put their children in the care of either the paternal or the maternal grandmothers. Others put the children in the care of a full-time housekeeper or a part-time housekeeper. While all the mothers had worked out a way to care for their children, almost all of them would use day care if facilities were available. Specifically, 42 per cent prefer child care at their work site, 21 per cent prefer family day care, and only 3 per cent indicated that they would not use any child care facilities. Most of the working mothers think that their employer should manage the day care program. Others prefer social agency or government management. Regarding costs, most prefer that costs should be split 50-50 between the employer and the family. In addition, professional working mothers wanted quality programs with educational components rather than mere custodial care. It was concluded that variety in types of quality child care programs should be available to provide working mothers the options of choosing what they want for their children. The main type of programs suggested by this study is work site based child care for children under 3 years of age. The existing law for the Saemaul Nursery School program should be implemented so as to include programs for children under 3.

  • PDF

Transmission Performance Evaluation of Hybrid Lines Composed of SMF and MMP for FTTx Systems (단일 모드 광섬유와 다중 모드 광섬유 혼합 라인으로 구성된 FTTx 시스템의 전송 성능 평가)

  • Park, Seung-Hyeon;Kim, Kyong-Hon;Lee, El-Hang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.7A
    • /
    • pp.535-541
    • /
    • 2005
  • This paper proposes a hybrid optical lines composed of single-mode fiber(SMF) and multi-mode fiber(MMF) for gigabit-capable Passive Optical Network(GPON) using a WDM method with a single light source per each channel, and reports the results of transmission performance the proposed lines. The transmission link uses a direct modulated DFB-LD for high speed downstreams at the optical line terminal(OLT) of central office(CO) and a low cost SFP type transceiver for low-speed upstream in optical network unit(ONU). To split or combine the transmission channels, wavelength MUX/DEMUX are used in the optical line section, and MMFs not longer than 1 km are attached to the SMF lines at the ONU side of the WDM-PON links. We have performed the transmission experiment on the downstream of 2.5 Gbit/s, and 1.25 Gbit/s, and the upstream of 1.25 Gbit/s, and 622 Mbit/s which are recommended by ITU-T G.984.2. The transmission margin and feasibility of the proposed links have been tested to be suitable up to 2.5 Gbit/s transmission.

Peroneal Flap: Clinical Application and Cadaveric Study

  • Ha, Yooseok;Yeo, Kwan Koo;Piao, Yibo;Oh, Sang-Ha
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.136-143
    • /
    • 2017
  • Background The goal of this study was to investigate the anatomy of the peroneal artery and its perforators, and to report the clinical results of reconstruction with peroneal artery perforator flaps. Methods The authors dissected 4 cadaver legs and investigated the distribution, course, origin, number, type, and length of the perforators. Peroneal artery perforator flap surgery was performed on 29 patients. Results We identified 19 perforators in 4 legs. The mean number of perforators was 4.8 per leg, and the mean length was 4.8 cm. Five perforators were found proximally, 9 medially, and 5 distally. We found 12 true septocutaneous perforators and 7 musculocutaneous perforators. Four emerged from the posterior tibia artery, and 15 were from the peroneal artery. The peroneal artery perforator flap was used in 29 patients. Retrograde island peroneal flaps were used in 8 cases, anterograde island peroneal flaps in 5 cases, and free peroneal flaps in 16 cases. The mean age was 59.9 years, and the defect size ranged from $2.0cm{\times}4.5cm$ to $8.0cm{\times}8.0cm$. All the flaps survived. Five flaps developed partial skin necrosis. In 2 cases, a split-thickness skin graft was performed, and the other 3 cases were treated without any additional procedures. Conclusions The peroneal artery perforator flap is a good alternative for the reconstruction of soft tissue defects, with a constant and reliable vascular pedicle, thin and pliable skin, and the possibility of creating a composite tissue flap.

Analysis of Spray Combustion for the Performance Prediction of Liquid Rocket Combustor (3차원 분무연소장 해석에 의한 액체추진기관 연소실 성능예측에 대한 연구)

  • 황용석;윤웅섭
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.3
    • /
    • pp.31-39
    • /
    • 1999
  • In this paper, numerical experiment is attempted to analyze and compare the combustion efficiency of the burning sprays due to OFO, FOF triplet / FOOF split doublet injectors. Preconditioned Wavier-Stokes equation system with low Reynolds number $\kappa$-$\varepsilon$ model for turbulence closure, is LU-SGS time-integrated. Spray processes are modeled by DSF analysis with experimentally determined injection characteristics. n-heptane/air global reaction model approximates the combustion for simplicity, and the influence of turbulence on the chemical reaction is included using eddy dissipation model. The results showed the FOF triplet injector of highest combustion efficiency, whereas the OFO type of poet performance. It was also observed that the droplet mean diameter and the average gas temperature due to the mixing efficiency, are the representative parameters for the performance design of combustion.

  • PDF

Fracture Toughness of Glass Fiber Reinforced Laminated Timbers (유리섬유 보강적층재의 파괴인성 특성)

  • Kim, Keon-ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.861-867
    • /
    • 2015
  • The Compact Tension (CT) type test was performed in order to evaluate the fracture toughness performance of glass fiber-reinforced laminated timber. Glass fiber textile and sheet Glass fiber reinforced plastic were used as reinforcement. The reinforced laminated timber was formed by inserting and laminating the reinforcement between laminated woods. Compact tension samples are produced under ASTM D5045. The sample length was determined by taking account of the end distance of 7D, and bolt holes (12 mm, 16 mm, 20 mm) had been made at the end of artificial notches in advance. The fracture toughness load of sheet fiberglass reinforced plastic reinforced laminated timber was increased 33 % in comparison to unreinforced laminated timber while the glass fiber textile reinforced laminated timber was increased 152 %. According to Double Cantilever Beam theory, the stress intensity factor was 1.08~1.38 for sheet glass fiber reinforced plastic reinforced laminated timber and 1.38~1.86 for glass fiber textile reinforced laminated timber, respectively. That was because, for the glass fiber textile reinforced laminated timber, the fiber array direction of glass fiber and laminated wood orthogonal to each other suppressed the split propagation in the wood.

Tensile Properties of Fiber Reinforced Concrete

  • Cho, Baik-Soon;Back, Sung-Yong;Park, Hyun-Jung
    • KCI Concrete Journal
    • /
    • v.12 no.2
    • /
    • pp.85-93
    • /
    • 2000
  • Potentially significant mechanical improvements in tension can be achieved by the incorporation of randomly distributed, short discrete fibers in concrete. The improvements due to the incorporation fibers significantly influence the composite stress - strain ($\sigma$-$\varepsilon$) characteristics. In general incorporating fibers in a plain concrete has relatively small effect on its precracking behavior. It, however, alters its post-cracking behavior quite significantly, resulting in greatly improved ductility, crack controls, and energy absorption capacity (or toughness). Therefore, a thorough understanding the complete tensile stress - strain ($\sigma$-$\varepsilon$) response of fiber reinforced concrete is necessary for proper analysis while using structural components made with fiber reinforced concrete. Direct tensile stress applied to a specimen is in principle the simplest configuration for determining the tensile response of concrete. However, problems associated with testing brittle materials in tension include (i) the problem related to gripping of the specimen and (ii) the problem of ensuring centric loading. Routinely, indirect tension tests for plain concrete, flexural and split-cylinder tests, have been used as simpler alternatives to direct uniaxial tension test. They are assumed to suitable for fiber reinforced concrete since typically such composites comprise 98% by volume of plain concrete. Clearly since the post-cracking characteristics are significantly influenced by the reinforcing parameters and interface characteristics, it would be fundamentally incorrect to use indirect tensile tests for determining the tensile properties of fiber reinforced concrete. The present investigation represents a systematic look at the failure and toughening mechanisms and macroscopic stress - strain ($\sigma$-$\varepsilon$) characteristics of fiber reinforced concrete in the uniaxial tension test. Results from an experimental parametric study involving used fiber quantity, type, and mechanical properties in the uniaxial tension test are presented and discussed.

  • PDF

Miniscrews versus surgical archwires for intermaxillary fixation in adults after orthognathic surgery

  • Son, Sieun;Kim, Seong Sik;Son, Woo-Sung;Kim, Yong-Il;Kim, Yong-Deok;Shin, Sang-Hun
    • The korean journal of orthodontics
    • /
    • v.45 no.1
    • /
    • pp.3-12
    • /
    • 2015
  • Objective: We compared the skeletal and dental changes that resulted from the use of two methods of intermaxillary fixation (IMF)-miniscrews and surgical archwire-in 74 adult patients who had Class III malocclusion and were treated with the same orthognathic surgical procedure at a hospital in Korea. Methods: All the patients underwent Le Fort I osteotomy and bilateral sagittal split ramus osteotomy with rigid fixation. They were divided into two groups according to the type of IMF used-group 1 underwent surgical archwire fixation and group 2 underwent orthodontic miniscrew fixation. In a series of cephalograms for each patient, we compared vertical and horizontal tooth-position measurements: (a) immediately after surgery ($T_0$), (b) 3 months after surgery ($T_1$), and (c) 6 months after surgery ($T_2$). Cephalometric changes within each group were examined using one-way analysis of variance (ANOVA) while the independent samples t -test procedure was used to compare the two groups. Results: After surgery, the maxillary incisors tended to be proclined in both groups although there were no significant differences. Incisor overbite increased significantly in both groups from $T_0$ to $T_1$, and the miniscrew group (group 2) showed slightly greater overbite than the archwire group (group 1). Conclusions: This study suggest that the use of orthodontic miniscrews and orthodontic surgical archwire for IMF in adult patients results in similar skeletal and dental changes.

A Method of Activity Recognition in Small-Scale Activity Classification Problems via Optimization of Deep Neural Networks (심층 신경망의 최적화를 통한 소규모 행동 분류 문제의 행동 인식 방법)

  • Kim, Seunghyun;Kim, Yeon-Ho;Kim, Do-Yeon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.3
    • /
    • pp.155-160
    • /
    • 2017
  • Recently, Deep learning has been used successfully to solve many recognition problems. It has many advantages over existing machine learning methods that extract feature points through hand-crafting. Deep neural networks for human activity recognition split video data into frame images, and then classify activities by analysing the connectivity of frame images according to the time. But it is difficult to apply to actual problems which has small-scale activity classes. Because this situations has a problem of overfitting and insufficient training data. In this paper, we defined 5 type of small-scale human activities, and classified them. We construct video database using 700 video clips, and obtained a classifying accuracy of 74.00%.

Analysis of Biocompatible TiO2 Oxide Multilayer by the XPS Depth Profiling

  • Jang, Jae-Myung;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.156-156
    • /
    • 2017
  • In this work, analysis of biocompatible TiO2 oxide multilayer by the XPS depth profiling was researched. the manufacture of the TiO2 barrier-type multilayer was accurately performed in a mixed electrolyte containing HAp, Pd, and Ag nanoparticles. The temperature of the solution was kept at approximatively $32^{\circ}C$ and was regularly rotated by a magnetic stirring rod in order to increase the ionic diffusion rate. The manufactured specimens were carefully analyzed by XPS depth profile to investigate the result of chemical bonding behaviors. From the analysis of chemical states of the TiO2 oxide multilayer using XPS, the peaks are showed with the typical signal of Ti oxide at 459.1 eV and 464.8 eV, due to Ti 2p(3/2) and Ti 2p(1/2), respectively. The Pd-3d peak was split into Pd-3d(5/2) and Pd-3d(3/2)peaks, and shows two bands at 334.7 and 339.9 eV for Pd-3d3 and Pd-3d5, respectively. Also, the peaks of Ag-3d have been investigated. The chemical states consisted of the O-1s, P-2p, and Ti-2p were identified in the forms of PO42- and PO43-. Based on the results of the chemical states, the chemical elements into the TiO2 oxide multilayer were also inferred to be penetrated from the electrolyte during anodic process.The structure characterization of the modified surface were performed by using FE-SEM, and from the result of biological evaluation in simulated body fluid(SBF), the biocompatibility of TiO2 oxide multilayer was effective for bioactive property.

  • PDF