• 제목/요약/키워드: Split Point

검색결과 220건 처리시간 0.023초

HgGa2S4:Co2+ 단결정에서 Co2+ 이온에 의한 광흡수 특성에 관한 연구 (Impurity Optical Absorption of Co2+ Ion in HgGa2S4:Co2+ Single Crystals)

  • 이상열;강종욱
    • 한국전기전자재료학회논문지
    • /
    • 제16권7호
    • /
    • pp.579-583
    • /
    • 2003
  • HgGa$_2$S$_4$: Co$^{2+}$ single crystal were grown by the chemical transport reaction(CTR) method. In the optical absorption spectrum of the HgGa$_2$S$_4$: Co$^{2+}$ single crystal measured at 298K, three groups of impurity optical absorption peaks consisting of three peaks, respectively, were observed at 673nm, 734nm, and 760nm, 1621nm, 1654nm, and 1734nm, and 2544nm, 2650nm, and 2678nm. At 10K, the three peaks(673nm, 734nm, and 760nm) of the first group were split to be twelve peaks. These impurity optical absolution peaks are assigned to be due to the electronic transitions between the split energy levels of Co$^{2+}$ sited in the S$_4$ symmetry point.

LCL Filter Design Method for Grid-Connected PWM-VSC

  • Majic, Goran;Despalatovic, Marin;Terzic, Bozo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1945-1954
    • /
    • 2017
  • In recent years, several LCL filter design methods for different converter topologies have been published, many of which use analytical expressions to calculate the ideal converter AC voltage harmonic spectrum. This paper presents the LCL filter design methodology but the focus is on presentation and validation of the non-iterative filter design method for a grid-connected three-phase two-level PWM-VSC. The developed method can be adapted for different converter topologies and PWM algorithms. Furthermore, as a starting point for the design procedure, only the range of PWM carrier frequencies is required instead of an exact value. System nonlinearities, usually omitted from analysis have a significant influence on VSC AC voltage harmonic spectrum. In order to achieve better accuracy of the proposed procedure, the system nonlinear model is incorporated into the method. Optimal filter parameters are determined using the novel cost function based on higher frequency losses of the filter. An example of LCL filter design for a 40 kVA grid-connected PWM-VSC has been presented. Obtained results have been used to construct the corresponding laboratory setup and measurements have been performed to verify the proposed method.

전력계통의 사고전류 저감 설비별 특성 비교 (Comparison of Fault Current Limiting Characteristics According to Facility in Power System)

  • 박형민;최효상;조용선;임성훈;황종선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.127-129
    • /
    • 2005
  • We investigated the fault current limiting characteristics according to the various facilities in power system. Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such as short circuits are increasing higher, which causes the ratings of circuit breakers(CBs) to increase. Upgrading or replacement of CBs is not difficult from the technical and economical point of view. Bus split is being adopted into a part of 154 kV power systems, but it has adverse effects such as overload to neighboring power systems, increased voltage fluctuation, and decreased power system stability. For 345 kV power systems, the bus split measure is not feasible and dc reactors are being suggested. The superconducting fault current limiter is a protection gear of new concept that limits fault current automatically in a few milliseconds. It can also provide the effect of CB capacity increase, relaxation of power machine criteria, enhancement in power system reliability, and flexible power system operation.

  • PDF

단일 위치에서의 측정을 이용한 가속도 종파 분리 방법의 개발 (Development of longitudinal acceleration wave decomposition method with single point measurement)

  • 정병보;박영진;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.629-633
    • /
    • 2006
  • We investigated a new longitudinal acceleration wave decomposition method in time domain. The proposed method separates up- and down-stream waves with an axial strain and axial acceleration measured at a single point on the transmission path. The advantages such as low computation load and easy implementation would be possible by developing time domain under the following assumptions; low frequency range, uniform cross sectional area and elastic wave propagation. We confirmed the feasibility and performance of the method through experiment using Split Hopkinson Pressure Bar (SHPB). The method can be effective in several applications, including active vibration control with wave view point, where real time wave decomposition is necessary.

  • PDF

플라스틱 SHPB기법을 사용한 고무의 고변형률 하중 하에서의 동적변형 거동 (Dynamic Deformation Behavior of Rubber Under High Strain-Rate Compressive Loading by Using Plastic SHPB Technique)

  • 이억섭;김경준
    • 한국정밀공학회지
    • /
    • 제20권11호
    • /
    • pp.158-165
    • /
    • 2003
  • A specific experimental method, the Split Hopkinson pressure bar (SHPB) technique has been widely used to determine the dynamic material properties under the impact compressive loading conditions with strain rate of the order of 10$^3$/s∼l0$^4$/s. In this paper, dynamic deformation behaviors of rubber materials widely used for the isolation of vibration from structure under varying dynamic loading are determined by using plastic SHPB technique. A transition point to scope with the dynamic deformation behavior of rubber-like material is defined in this paper and used to characterize the specifics of the dynamic deformation of rubber materials.

Numerical analysis of Brazilian split test on concrete cylinder

  • Wosatko, Adam;Winnicki, Andrzej;Pamin, Jerzy
    • Computers and Concrete
    • /
    • 제8권3호
    • /
    • pp.243-278
    • /
    • 2011
  • The paper presents simulations of the Brazilian test using two numerical models. Both models are regularized in order to obtain results independent of discretization. The first one, called gradient damage, is refined by additional averaging equation which contains gradient terms and an internal length scale as localization limiter. In the second one, called viscoplastic consistency model, the yield function depends on the viscoplastic strain rate. In this model regularization properties are governed by the assumed strain rate. The two models are implemented in the FEAP finite element package and compared in this paper. Parameter studies of the split test are performed in order to point out the features of each model.

3차원 영상의 자동 소실점 검출을 위한 분할 영상 좌표계 (Split Image Coordinate for Automatic Vanishing Point Detection in 3D images)

  • 이정화;김종화;서경석;최흥문
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.1891-1894
    • /
    • 2003
  • 본 논문에서는 분할 영상 좌보계 (split image coordinate: SIC)를 제안하여 3차원 영상의 주요 특징 중의 하나인 유, 무한 소실점을 그 위치의 무한성이나 카메라의 보정과 관계없이 정확하게 자동 추출하였다. 제안한 방법에서는 가우시안 구 (Gaussian sphere) 기반의 기존 방법들과는 달리 영상 공간을 누적 공간으로 활용함으로써 카메라 보정이나 영상의 사전정보가 없어도 원 영상의 정보 손실 없이 소실점을 추출할 수 있고, 영상을 무한대까지 확장한 후 분할하여 재정의 함으로써 유, 무한 소실점을 모두 추출할 수 있도록 하였다. 정확한 소실점의 검출을 위하여 직선 검출 과정에서는 방향성 마스크 (mask)를 사용하였으며, 직선들의 군집화 (clustering) 과정에서는 기울기 히스토그램 방법과 수평/수직 군집화 방법을 적응적으로 적용하였다. 제안한 방법을 합성 영상 및 건축물 (man-made environment) 영상에 적용시켜 유, 무한 소실점들을 효과적이고 정확하게 찾을 수 있음을 확인하였다.

  • PDF

A Study on Split Variable Selection Using Transformation of Variables in Decision Trees

  • Chung, Sung-S.;Lee, Ki-H.;Lee, Seung-S.
    • Journal of the Korean Data and Information Science Society
    • /
    • 제16권2호
    • /
    • pp.195-205
    • /
    • 2005
  • In decision tree analysis, C4.5 and CART algorithm have some problems of computational complexity and bias on variable selection. But QUEST algorithm solves these problems by dividing the step of variable selection and split point selection. When input variables are continuous, QUEST algorithm uses ANOVA F-test under the assumption of normality and homogeneity of variances. In this paper, we investigate the influence of violation of normality assumption and effect of the transformation of variables in the QUEST algorithm. In the simulation study, we obtained the empirical powers of variable selection and the empirical bias of variable selection after transformation of variables having various type of underlying distributions.

  • PDF

듀얼 모드 하이브리드 동력전달계 (Dual-mode Hybrid Powertrain)

  • 양호림;김남욱;안국현;조성태;임원식;이장무
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.543-546
    • /
    • 2006
  • 최근 여러 연구에서 다양한 종류의 멀티 모드 하이브리드 동력 전달계가 제안되고 있다. 멀티모드 동력전달계는 두 개 이상의 다른 유성기어식 하이브리드 시스템으로 이루어져 있으며 클러치를 사용하여 각 상황에 유리한 유성기어 시스템을 사용하여 주행한다. 각 유성기어 시스템의 단점들을 보완할 수 있기 때문에 단일 모드를 사용하여 주행했을 때보다 여러 면에서 높은 성능을 보인다. 일반적으로 유성기어식 하이브리드 시스템은 크게 입력, 출력, 복합 분기식의 세 가지 종류로 나눌 수 있는데 이 논문에서는 입력 및 복합 분기식 구조의 특징을 분석해 보았다. 또한 시뮬레이션을 통해 입력, 복합 분기식 구조를 사용하여 듀얼 모드를 구성하였을 때 단일 모드와 비교하여 어느정도의 성능을 보이는지 알아보았다.

  • PDF

Bone and Soft Tissue Changes after Two-Jaw Surgery in Cleft Patients

  • Yun, Yung Sang;Uhm, Ki Il;Kim, Jee Nam;Shin, Dong Hyeok;Choi, Hyun Gon;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • Archives of Plastic Surgery
    • /
    • 제42권4호
    • /
    • pp.419-423
    • /
    • 2015
  • Background Orthognathic surgery is required in 25% to 35% of patients with a cleft lip and palate, for whom functional recovery and aesthetic improvement after surgery are important. The aim of this study was to examine maxillary and mandibular changes, along with concomitant soft tissue changes, in cleft patients who underwent LeFort I osteotomy and sagittal split ramus osteotomy (two-jaw surgery). Methods Twenty-eight cleft patients who underwent two-jaw surgery between August 2008 and November 2013 were included. Cephalometric analysis was conducted before and after surgery. Preoperative and postoperative measurements of the bone and soft tissue were compared. Results The mean horizontal advancement of the maxilla (point A) was 6.12 mm, while that of the mandible (point B) was -5.19 mm. The mean point A-nasion-point B angle was $-4.1^{\circ}$ before surgery, and increased to $2.5^{\circ}$ after surgery. The mean nasolabial angle was $72.7^{\circ}$ before surgery, and increased to $88.7^{\circ}$ after surgery. The mean minimal distance between Rickett's E-line and the upper lip was 6.52 mm before surgery and 1.81 mm after surgery. The ratio of soft tissue change to bone change was 0.55 between point A and point A' and 0.93 between point B and point B'. Conclusions Patients with cleft lip and palate who underwent two-jaw surgery showed optimal soft tissue changes. The position of the soft tissue (point A') was shifted by a distance equal to 55% of the change in the maxillary bone. Therefore, bone surgery without soft tissue correction can achieve good aesthetic results.